• 제목/요약/키워드: Mechanical Circuit Breaker

검색결과 95건 처리시간 0.033초

단락시험에서 후비보호차단기와 투입스위치의 중요 역할 (The study of a primary role of Back up Breaker and Making Switch for Short Circuit Test)

  • 김선구;김선호;김원만;노창일;이동준;정흥수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.915-916
    • /
    • 2007
  • There are many equipments for the Short Circuit Test, for example Short Circuit Generator, Induction Motor, Sequence Timer, Exciter, CLR, Back Up Breaker, Making Switch and TRV etc. Especially Back up Breaker and Making Switch are very important equipments to test the short circuit test. A role of a Back up Breaker is to break high-voltage and high-current for short circuit test and a Making Switch should be operated always same speed/time and kept electrical-mechanical characteristics to make the voltage and current of short circuit test. This study introduces to the short circuit test also to kinds, principal movements and compare them of Back up Breaker and Making Switch.

  • PDF

Development of the Controlled Switching Device for a Cirrcuit Breaker

  • Kim, Ik-Mo;Kim, Myung-Chan;Choi, Young-Chan;Ryu, Sung-Sic;Kim, Dong-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.558-560
    • /
    • 2004
  • Studies on the controlled switching method have been done to prevent the power system surges which cause the insulation deterioration and electro magnetic compatibility (EMC) problems during closing and opening of a circuit breaker. The controlled switching method controls the closing and tripping time in coincidence with the voltage or current to suppress switching surge. It is used to switch condenser bank, no load transformer, and shunt reactor. In this study, basic concept of the controlled switching is introduced, and also the test is performed to find parameters of the controlled switching in a 24kV vacuum circuit. And then, the control device hardware using TMS320C31 DSP has been designed and manufactured. It has been found that the application of IT technology to a circuit breaker is very effective to depress the switching surge.

  • PDF

고전압 차단기용 솔레노이드 액추에이터의 거동 (Behavior of the Solenoid Actuator for High-Voltage Circuit Breaker)

  • 윤소남;함영복;안병규;김고도
    • 유공압시스템학회논문집
    • /
    • 제1권3호
    • /
    • pp.1-6
    • /
    • 2004
  • In the last few years, a considerable number of studies have been made on On-Off solenoid for fluid control. But, only few attempts have so far been made at solenoid actuator for high-voltage circuit breaker. In case of the high-pressure and high-flow system like high-voltage circuit breaker, a big size of On/Off solenoid is necessary which size is proportional to control pressure and flow rate. So, it is non-effective in the view point of system optimization. In this paper, On/Off solenoid actuator with the farce amplifier connected to the solenoid rod was proposed to get a high mechanical force and a fast response time. The magnetic force and the mechanical stress distributions were analysed using finite element analysis. The performances of suggested solenoid actuator were evaluated through the experimental results and compared with the analysis results.

  • PDF

충전 동작이 용이한 간단한 구조의 DC 반도체 차단기 (A Simple-Structured DC Solid-State Circuit Breaker with Easy Charging Capability)

  • 김진영;김인동
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1575-1583
    • /
    • 2017
  • With the development of DC distribution, DC circuit breaker is required to ensure the stability of the DC grid. Unlike a mechanical circuit breaker that blocks after several tens of milliseconds, a DC SSCB(Solid-State Circuit Breaker) can break the fault well within 1 [ms], so it can prevent the damage of accident. However, the previous DC SSCB requires a lot of switching elements for charging commutation capacitors, and the control is complicated. Therefore, this paper proposes a new DC SSCB suitable for DC grid. The proposed DC SSCB is simple to control for charging commutation capacitors, and it can perform the rapid breaking and operating duty of reclosing and rebreaking. The proposed DC SSCB was designed to 380 [V] and 5 [kW] class which is suitable for residential DC distribution, and the operating characteristics of the proposed DC SSCB were verified by simulations and experiments. It is anticipated that the proposed DC SSCB may be utilized to design and realize DC grid system.

Z-source 직류 차단기의 기계식 스위치 적용을 위한 최적화 설계 (Optimization Design for the Use of Mechanical Switch in Z-source DC Circuit Breaker)

  • 이현승;이건아
    • 한국안전학회지
    • /
    • 제37권1호
    • /
    • pp.12-19
    • /
    • 2022
  • Circuit breakers are a crucial factor in ensuring the safety of a Direct Current (DC) grid. One type of DC circuit breaker, the Z-source DC circuit breaker (ZCB), uses a thyristor, which is a type of semiconductor switch. In the event of a fault in the circuit, the ZCB isolates the fault by generating a zero crossing current in the thyristor. The thyristor quickly and actively isolates the fault while generating a zero crossing current, but thyristor switch cannot control turn-off and the allowable current is lower than the current of the mechanical switch. Therefore, it is best to use a mechanical switch with a high allowable current capacity that is capable of on/off control. Due to the slow reaction time of mechanical switches, they may not isolate the fault during the zero crossing current time interval created by the existing circuit. In this case, the zero crossing current time can be increased by using the property that hinders the rapid change in the current of the inductor. This paper will explore whether adding system inductance to increase the zero crossing current time interval is a solution to this problem. The simulation of changing inductor and capacitor (LC) of the circuit is repeated to find an optimal change in the zero crossing current time according to the LC change and provides an inductor and capacitor range optimized for a specific load. The inductor and capacitor range are expected to provide optimization information in the form LC values for future applications of ZCB's using a mechanical switch.

Electromagnetic Actuator with Novel Electric Brake for Circuit Breaker

  • Bae, Byungjun;Kim, Minjae
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.340-347
    • /
    • 2016
  • At the stroke end of an electromagnetic circuit breaker, the high speed of the mover makes a huge impact at the contact point, which induces the rebound problem of the mover that causes a breaker failure. Thus, a speed reduction equipment is required to address such problems. This study suggests to use an electric brake reduces the speed at the end of the stroke. The proposed circuit breaker which adopts the electric brake has a variable speed reduction function such that the continued rebound phenomenon ceases to occur. The electric brake is designed by the Finite Element Method (FEM) and the circuit and motion equations are solved using Time Difference Method (TDM). The comparisons between the simulation and experiments demonstrated the usefulness and validity of this study.

전류 차단기 메커니즘에서 에너지방법을 이용한 차단 속도에 따른 스프링 모델링 (Opening Spring Modeling of Current Circuit Breaker Mechanism with respect to Opening Speed using Energy Method)

  • 권병희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.688-692
    • /
    • 2000
  • This study proposed design parameters of opening spring of circuit breaker that cut off the over-current in order to protect the electric device about opening speed using the energy method. We simulated the opening kinetic energy, the potential energy of opening spring and the design parameters of opening spring with respect to opening speed of VCB (Vacuum Circuit Breaker)'s moving contactor which has 24kV 25kA break capacity. From the result of simulation the initial tensional force and the final tensional force of the opening spring chose 107kgf and 282kgf respectively. Through the dynamic analysis using ADAMS, We verified that the opening speed of moving contactor satisfied break capacity of VCB and analyzed opening dynamic characteristics of VCB such as the opening displacement, the opening velocity and the opening acceleration of moving contactor in time domain.

  • PDF

회로차단기용 스프링조작기의 기구동역학 해석을 위한 스프링모델링 기법 연구 (Study of Spring Modeling Techniques for Kinematic and Dynamic Analysis of a Spring Operating Mechanism for the Circuit Breaker)

  • 손정현;이승규;김승오;유완석
    • 대한기계학회논문집A
    • /
    • 제31권7호
    • /
    • pp.777-783
    • /
    • 2007
  • Since the performance of the circuit breaker mainly depends on the spring operating mechanism, the analysis of the spring operating mechanism is required. The spring, especially closing spring, stores the deformation energy due to the compression and then accelerates the big loads rapidly in the circuit breaker. To accurately carry out the kinematic and dynamic analysis of the circuit breaker, the precise modeling of the spring behavior is necessary. In this paper, the static stiffness of the spring is captured by using the tester. A simple mechanism similar to the spring operating mechanism was designed to generate the release motion of the spring. A high speed camera was used to capture the behavior of the spring. Three types of spring models such as a linear spring model, modal spring model, and nodal spring model are suggested and compared with the experimental results.

A Novel AC Solid-State Circuit Breaker with Reclosing and Rebreaking Capability

  • Kim, Jin-Young;Choi, Seung-Soo;Kim, In-Dong
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.1074-1084
    • /
    • 2015
  • These days, the widespread use of sensitive loads and distributed generators makes the solid-state circuit breaker (SSCB) an essential component in power circuits to achieve a high power quality for AC Grids. In traditional AC SSCB using SCRs, some auxiliary mechanical devices are required to make the reclosing operation possible before fault recovery. However, the proposed AC SSCB can break quickly and then be reclosed without auxiliary mechanical devices even during the short-circuit fault. Moreover, its fault current breaking time is short and its SSCB reclosing operation is fast. This results in a reduction of the economic losses due to fault currents and power outages. Through simulations and experiments on short-circuit faults, the performance characteristics of the proposed AC SSCB are verified. A design guideline is also suggested to apply the proposed AC SSCB to various AC grids.

가스차단기의 소호노즐 내부에서 발생하는 압축성 유동에 관한 연구 (Study of the Compressible Nozzle Flow in a Gas Circuit Breaker)

  • 정성재;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.123-126
    • /
    • 2002
  • Very frequently the compressible flow in an extinction nozzle of gas circuit breaker is simulated under no arc assumption, which can be reasonable for both high and low current breakings. In the present study, computations are performed to investigate the major features of the compressible flows inside the arc extinction nozzle of gas circuit breaker. A fully implicit finite volume scheme is applied to solve the two-dimensional, steady, compressible, Wavier-Stokes equations. The computed results are validated with the previous experimental data available. Several types of turbulence models are explored to reasonably predict the complicated flows inside the arc extinction nozzle. The obtained results show that the shock wave boundary layer interaction inside the nozzle significantly influences the whole performance of the gas breaker.

  • PDF