• Title/Summary/Keyword: Measuring methods

Search Result 4,498, Processing Time 0.031 seconds

Feasibility study of the usefulness of SRS thermoplastic mask for head & neck cancer in tomotherapy (두경부 종양의 토모치료 시 정위적방사선수술 마스크의 유용성 평가에 대한 연구)

  • Jeon, Seong Jin;Kim, Chul Jong;Kwon, Dong Yeol;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.355-362
    • /
    • 2014
  • Purpose : When head&neck cancer radiation therapy, thermoplastic mask is applied for patients with fixed. The purpose of this study is to evaluate usefulness of thermoplastic mask for SRS in tomotherapy by conparison with the conventional mask. Materials and Methods : Typical mask(conventional mask, C-mask) and mask for SRS are used to fix body phantom(rando phantom) on the same iso centerline, then simulation is performed. Tomotherapy plan for orbit and salivary glands is made by treatment planning system(TPS). A thick portion and a thin portion located near the treatment target relative to the mask S-mask are defined as region of interest for surface dose dosimetry. Surface dose variation depending on the type of mask was analyzed by measuring the TPS and EBT film. Results : Surface dose variation due to the type of mask from the TPS is showed in orbit and salivary glands 0.65~2.53 Gy, 0.85~1.84 Gy, respectively. In case of EBT film, -0.2~3.46 Gy, 1.04~3.02 Gy. When applied to the S-mask, in TPS and Gafchromic EBT3 film, substrantially 4.26%, 5.82% showed maximum changing trend, respectively. Conclusion : To apply S-mask for tomotherapy, surface dose is changed, but the amount is insignificant and be useful when treatment target is close critical organs because decrease inter and intra fractional variation.

The Study of Distance and Near AC/A Ratio by Stimulus (조절자극 방식에 따른 원거리와 근거리 AC/A비에 관한 연구)

  • Jo, Tae-Sik;Kim, In-Suk;Jang, Jung-Un
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.417-423
    • /
    • 2011
  • Purpose: This study was to investigate that near gradient AC/A ratio could be used to prescribe a patient with distance exophoria, we compared the difference between distance gradient AC/A ratio and near gradient AC/A ratio. Also, this thesis was to understand the relationship between calculated AC/A ratio and gradient AC/A ratio. Methods: Objective and subjective refractive error were corrected and we used Howell (3 m) chart for distance phoria tests and Howell-Kim (40 cm) chart for near phoria tests. The near gradient AC/A ratio and calculated AC/A ratio were used by Howell-Kim (40 cm) combined with +1.00 D, -1.00 D, +2.00 D and -2.00 D. Results: The average value of distance exophoria was 1.17${\pm}$1.17 $\Delta$, and the average value of near exophoria was 3.71${\pm}$2.80 $\Delta$ (t-test. p<0.001). The correlation of distance phoria with near phoria was little higher (r = 0.59, p < 0.001). Gradient AC/A ratios depending on measuring distance and stimulus were higher (r = 0.11~0.53. P < 0.001), when distance was shorter and stimulus to accommodation was more. Also, stimulus to accommodation by plus lens was higher than stimulus to accommodation by minus lens (paired t-test. p < 0.001). There was negative correlation between calculated AC/A ratio and gradient AC/A ratio. As the calculated AC/A ratio was higher, gradient AC/A ratio was lesser. Near gradient AC/A ratio was slightly higher than distance gradient AC/A ratio. Distance and near gradient AC/A ratio taken through the subjective -1.00 D were 1.30 $\Delta$/D and 1.68 $\Delta$/D(t-test. t=1.67, p < 0.001). Conclusions: There is negative correlation between calculated AC/A ratio and gradient AC/A ratio. Also, there is subtle difference between near gradient AC/A ratio and distance gradient AC/A ratio. Therefore, we need to measure distance gradient AC/A ratio when a practitioner prescribe glasses for a patient with distance exophoria.

Quality Verification for Respiratory Gated Proton Therapy (호흡동조 양성자치료의 Quality Verification)

  • Kim, Eun Sook;Jang, Yo Jong;Park, Ji Yeon;Kang, Dong Yun;Yeom, Doo Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.107-113
    • /
    • 2013
  • Purpose: To verify accuracy of respiratory gated proton therapy by measuring and analyzing proton beam delivered when respiratory gated proton therapy is being performed in our institute. Materials and Methods: The plan data of 3 patients who took respiratory gated proton therapy were used to deliver proton beam from proton therapy system. The manufactured moving phantom was used to apply respiratory gating system to reproduce proton beam which was partially irradiated. The key characteristics of proton beam, range, spreat-out Bragg peak (SOBP) and output factor were measured 5 times and the same categories were measured in the continuous proton beam which was not performed with respiratory gating system. Multi-layer ionization chamber was used to measure range and SOBP, and Scanditronix Wellhofer and farmer chamber was used to measure output factor. Results: The average ranges of 3 patients (A, B, C), who had taken respiratory gated proton therapy or not, were (A) 7.226, 7.230, (B) 12.216, 12.220 and (C) 19.918, 19.920 $g/cm^2$ and average SOBP were (A) 4.950, 4.940, (B) 6.496, 6.512 and (C) 8.486, 8.490 $g/cm^2$. And average output factor were (A) 0.985, 0.984 (B) 1.026, 1.027 and (C) 1.138, 1.136 cGy/MU. The differences of average range were -0.004, -0.004, -0.002 $g/cm^2$, that of SOBP were 0.010, -0.016, -0.004 $g/cm^2$ and that of output factor were 0.001, -0.001, 0.002 cGy/MU. Conclusion: It is observed that the range, SOBP and output factor of proton beam delivered when respiratory gated proton therapy is being performed have the same beam quality with no significant difference compared to the proton beam which was continuously irradiated. Therefore, this study verified the quality of proton beam delivered when respiratory gated proton therapy and confirmed the accuracy of proton therapy using this.

  • PDF

Effect of immobilization of the recombinant human bone morphogenetic protein 2 (rhBMP-2) on anodized implants coated with heparin for improving alveolar ridge augmentation in beagle dogs: Radiographic observations (양극산화 임플란트 표면에 적용된 헤파린과 골형성단백질(rhBMP-2)이 치조골 증대에 미치는 효과: 방사선학적 평가)

  • Lee, So-Hyoun;Jo, Jae-Young;Yun, Mi-Jung;Jeon, Young-Chan;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.307-314
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate the effect of immobilization of the recombinant human bone morphogenetic protein 2 (rhBMP-2) on anodized titaum implants coated with heparin to enhance the vertical alveolar ridge augmentation in the supraalveolar peri-implant defect region. Materials and methods: 18 pure titanium implants (7.0 mm in length, 3.5 mm in diameter) were manufactured for this study. All implants were anodized and designed insertion reference line marked with laser at the apical 2.5 mm from the fixture platform. Implantation of 6 noncoated anodized implants (Control group), 6 anodized implants physically adsorbed with rhBMP-2 by dip and dry method (BMP group) and 6 anodized implants chemically immobilized 3,4-dihydroxyphenylalanine (DOPA)-heparin/ rhBMP-2 (Hep-BMP group) was performed in the both mandibular of three male adult beagle dogs using split-mouth design. Radiologic examinations were performed immediately after implant placement and 4 and 8 weeks after implant placement. The amount of mesio-distal bone augmentation was evaluated by measuring the vertical distance from the platform to the marginal bone. Statistical analysis was performed using one-way analysis of variance (SPSS version 18.0) and multiple comparison analysis of The Kruskal-Wallis test and the Mann-Whitney U test. Statistical significance was established at the 5% significant level. Results: At the 4 weeks vertical alveolar ridge augmentation of Control group, BMP group and Hep-BMP group is $0.09{\pm}0.22mm$, $1.02{\pm}0.72mm$, and $1.29{\pm}0.51mm$, At the 8 weeks $0.11{\pm}1.26mm$, $1.11{\pm}0.58mm$, $1.59{\pm}0.79mm$ according to radiographic observations. The two experimental groups showed a significantly increasing in vertical bone height compared with the control group (P<.05). However, there is no significant difference between the BMP group and Hep-BMP group (P>.05). Conclusion: The rhBMP-2 coated implants were enhanced the vertical bone growth in the supraalveolar peri-implant defect area. However, there is no significant difference between chemically and physically coating method.

Clinical Experience with 3.0 T MR for Cardiac Imaging in Patients: Comparison to 1.5 T using Individually Optimized Imaging Protocols (장비 별 최적화된 영상 프로토콜을 이용한 환자에서의 3.0T 심장 자기공명영상의 임상경험: 1.5 T 자기공명영상과의 비교)

  • Ko, Jeong Min;Jung, Jung Im;Lee, Bae Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.83-90
    • /
    • 2013
  • Purpose : To report our clinical experience with cardiac 3.0 T MRI in patients compared with 1.5 T using individually optimized imaging protocols. Materials and Methods: We retrospectively reviewed 30 consecutive patients and 20 consecutive patients who underwent 1.5 T and 3 T cardiac MRI within 10 months. A comparison study was performed by measuring the signal-to-noise ratio (SNR), the contrast-to-noise ratio (CNR) and the image quality (by grading each sequence on a 5-point scale, regarding the presence of artifacts). Results: In morphologic and viability studies, the use of 3.0 T provided increase of the baseline SNRs and CNRs, respectively (T1: SNR 29%, p < 0.001, CNR 37%, p < 0.001; T2-SPAIR: SNR 13%, p = 0.068, CNR 18%, p = 0.059; viability imaging: SNR 45%, p = 0.017, CNR 37%, p = 0.135) without significant impairment of the image quality (T1: $3.8{\pm}0.9$ vs. $3.9{\pm}0.7$, p = 0.438; T2-SPAIR: $3.8{\pm}0.9$ vs. $3.9{\pm}0.5$, p = 0.744; viability imaging: $4.5{\pm}0.8$ vs. $4.7{\pm}0.6$, p = 0.254). Although the image qualities of 3.0 T functional cine images were slightly lower than those of 1.5 T images ($3.6{\pm}0.7$ vs. $4.2{\pm}0.6$, p < 0.001), the mean SNR and CNR at 3.0 T were significantly improved (SNR 143% increase, CNR 108% increase, p < 0.001). With our imaging protocol for 3.0 T perfusion imaging, there was an insignificant decrease in the SNR (11% decrease, p = 0.172) and CNR (7% decrease, p = 0.638). However, the overall image quality was significantly improved ($4.6{\pm}0.5$ vs. $4.0{\pm}0.8$, p = 0.006). Conclusion: With our experience, 3.0 T MRI was shown to be feasible for the routine assessment of cardiac imaging.

Nutritional Risk, Perceived Health Status, and Depression of the Young-Old and the Old-Old in Low-Income Elderly Women (저소득층 전기여성노인과 후기여성노인의 영양위험, 지각된 건강상태와 우울)

  • Lee, Myung-Suk
    • Journal of agricultural medicine and community health
    • /
    • v.37 no.1
    • /
    • pp.12-22
    • /
    • 2012
  • Objectives: This study aimed to compare the nutritional risk, health status and depression levels of young-old (65-74 years) and old-old (75-84 years) women on low-income. Methods: A total of 624 elderly women, each over 65 years of age, participated in this study under the auspices of a community social center. Data were collected from June to August 2011 by means of personal interviews which employed questionnaires. The research tools used in this study were the nutritional risk measuring Mini Nutritional Assesment (MNA) by Kim (2000), perceived health status developed by Lawton et al. (1982), Elderly Depression Criterion developed by Sheikh & Yesavage (1985). The collected data were analyzed using the SPSS WIN 12.0 Program. Results: Nutritional risk, perceived health status and depression levels showed a significant difference between young-old and old-old. There was a positive correlation between nutritional risk and depression and a negative correlation between nutritional risk and perceived health status. A 38.2% variance in depression levels of young-old and a 29.7% variance in depression levels of old-old were explained by perceived health status, nutritional risk and the number of people living together. Conclusion: The findings demonstrate variances in depression levels among low - income women differing in age. As a result, the outcomes of this study ought to be employed in the development of future programs aimed at promoting the health of elderly women.

Development of the Korean Version of the Brief Measure of Worry Severity(BMWS) (한국어판 간이걱정척도의 개발)

  • Lim, Jae-Hyoung;Joe, Sook-Haeng;Han, Chang-Su;Kim, Seung-Hyun;Yang, Jae-Won;Lee, Moon-Soo;Jeong, Hyun-Ghang;Ko, Young-Hoon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.19 no.2
    • /
    • pp.92-100
    • /
    • 2011
  • Objectives:We developed a Korean version of the Brief Measure of Worry Severity(BMWS), and examined its reliability, validity, and factor structures. We also explored the associations of pathological worry with depression and anxiety. Methods:Three hundreds fifty-two subjects including community population and college students completed the BMWS, and 27 subjects repeated the scale three weeks later. Reliability was assessed by Cronbach's coefficient ${\alpha}$ and test-retest correlation. The external validity was examined by the correlation of the BMWS score with the scores of Beck Depression Inventory(BDI), Patient Health questionnaire-2(PHQ-2), State Anxiety Inven-tory(SAI), and Trait Anxiety Inventory(TAI). And principal component analysis was performed to evaluate the construct validity. The associations of pathological worry with depression and anxiety were explored using partial correlation analysis. Results:Cronbach's coefficient ${\alpha}$ for the BMWS was 0.904 and test-retest correlation was 0.56(P<0.01). The Spearman correlation coefficients of the BMWS score with the scores of BDI, PHQ-2, SAI, and TAI were 0.60(P<0.01), 0.42(P<0.01), 0.36(P<0.01), and 0.59(P<0.01), respectively. The BMWS showed unifactorial construct. When controlling for TAI score, the correlation coefficient between the BMWS score and the BDI score was 0.357(P<0.01), and when controlling for BDI score the correlation coefficient between the BMWS score and the TAI score was 0.446(P<0.01). Conclusion:The Korean version of the BMWS was found to be a reliable and valid questionnaire for measuring pathological worry. And we could identify the associations of the pathological worry with depression as well as anxiety.

  • PDF

SEMI-LONGITUDINAL STUDY ON GROWTH AND DEVELOPMENT OF CHILDREN AGED 6 TO 17 Part II : GROWTH CHANGE OF CRANIOFACIAL SOFT TISSUE (한국인 6-17세 아동의 성장과 발육에 관한 준종단적 연구 제 2 세부과제 : 두개 및 안면 연조직의 성장변화)

  • Park, Young-Chel;Lee, Kee-Joon;Han, Hee-Kyoung;Lee, Jang-Yeol
    • The korean journal of orthodontics
    • /
    • v.26 no.4
    • /
    • pp.325-340
    • /
    • 1996
  • Along with traditional goal of 'straightening teeth', today's orthodontics put more and more emphasis on facial esthetics. Naturally, the importance of soft tissue, which dictates one's facial form, is noticed. There have been many cephalometric studies on growth of hard tissue ; however, only a few on that of soft tissue. In Korea, various methods of sampling, measuring and analysing were used to study soft tissue changes, and yet, soft tissue changes along with process of normal growth have not been studied. The author carried out this study as a part of semi-longitudinal study on craniofacial growth and development of Korean children from ages of six to seventeen. 409 boys and 436 girls who'd had no systemic disease for the last three years and shown normal developmental and occlusal status were chosen as subjects. Cephalometric X-rays were taken of each subject, and facial form, lip position & form, nose form, and lip thickness were measured. Mean values and standard deviations were calculated according to age and gender, and figures and tables were drawn accordingly. The following results were obtained: 1. In respect to facial form, boys showed growth for longer period compared to girls. Also, lower face showed higher growth rate than upper face. 2. There was not much change in thickness of upper and lower lips with age; however, they appeared more prominent compared to caucasian children. 3. Nose grew horizontally with age. 4. Horizontal thickness of lower face increased with age, and upper lip thickness at nose base[A-Sn(FH)] showed more growth than anywhere else.

  • PDF

A study anxiety of mothers who have hospitalized ill children Focusing on the comparison of korean mothers with multicultural family mothers (입원 환아 어머니의 불안에 관한 연구: 한국인 어머니와 다문화가정 어머니 비교를 중심으로)

  • Oh, Jae-Woo;Moon, Young-Sook
    • Journal of Digital Convergence
    • /
    • v.10 no.6
    • /
    • pp.311-319
    • /
    • 2012
  • This study, by grasping the degree of anxiety of Korean mothers and multicultural family mothers because of their hospitalized children, was aimed to arrange the basic data for developing the program to help the mothers of Korea and multicultural family reduce the anxiety happening due to the hospitalization of their children and adapt to their environment. Methods: The subjects of the study were a total of 200 people composed of 100 multicultural family mothers, and 100 Korean mothers respectively whose children were hospitalized in the pediatric department of K university hospital located in Daejeon City. And the period of data collection was from Aug 1, 2010 to Aug 31, 2010.As a study tool, the measuring tool of Kim Jeong Taek(1978), which STAI of Sielberger(1972) was adapted to Koreans, was used.The collected data was analyzed using SPSS WIN 12.0. Results. A result of the state anxiety of the Korean mothers with that of the multicultural family mothers of the inpatient children, Korean mothers 2.11, multicultural family mothers 2.17, result of temperament anxiety showed Korean mothers 2.09, multicultural family mothers 1.94. As a result of comparing the anxiety of the Korean mothers with that of the multicultural family mothers of the inpatient children, there was no difference between groups in both temperament anxiety and state anxiety. In a situation of anxiety, when there was no explanation of the treatment or therapy, both Korean mothers and multicultural family mothers showed the severe anxiety. In the degree of anxiety according to the general characteristics of the mothers of the inpatient children, there was not a statistically significant result in anxiety according to general characteristics of the inpatient children of korean family mothers, there was a significant difference in state anxiety according to the state of average monthly income in Korean mothers(P<.05), however, there was a significant one in temperament anxiety in the course of perceiving a test method in multicultural family mothers(P<.05). In the degree of anxiety according to the general characteristics of the mothers of the inpatient children, there was a significant difference in state anxiety according to the state of average monthly income in Korean mothers(P<.05), however, there was a significant one in temperament anxiety in the course of perceiving a test method in multicultural family mothers(P<.05). Conclusion: Through the results of the study above, no matter what socio-demographic characteristics of the mothers of the inpatient children are, regardless of the general characteristics of the inpatient children, it was found out that most of mothers felt anxiety.

Assessment of the usefulness of the Machine Performance Check system that is an evaluation tools for the determination of daily beam output (일간 빔 출력 확인을 위한 평가도구인 Machine Performance Check의 유용성 평가)

  • Lee, Sang Hyeon;Ahn, Woo Sang;Lee, Woo Seok;Choi, Jin Hyeok;Kim, Seon Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.65-73
    • /
    • 2017
  • Purpose: Machine Performance Check (MPC) is a self-checking software based on the Electronic Portal Imaging Device (EPID) to measure daily beam outputs without external installation. The purpose of this study is to verify the usefulness of MPC by comparing and correlating daily beam output of QA Beamchecker PLUS. Materials and Methods: Linear accelerator (Truebeam 2.5) was used to measure 10 energies which are composed of photon beams(6, 10, 15 MV and 6, 10 MV-FFF) and electron beams(6, 9, 12, 16 and 20 MeV). A total of 80 cycles of data was obtained by measuring beam output measurement before treatment over five months period. The Pearson correlation coefficient was used to evaluate the consistency of the beam output between the MPC and the QA Beamchecker PLUS. In this study, if the Pearson correlation coefficient is; (1) 0.8 or higher, the correlation is very strong (2) between 0.6 and 0.79, the correlation is strong (3) between 0.4 and 0.59, the correlation is moderate (4) between 0.2 and 0.39, the correlation is weak (5) lower than 0.2, the correlation is very weak. Results: Output variations observed between MPC and QA Beamchecker PLUS were within 2 % for photons and electrons. The beam outputs variations of MPC were $0.29{\pm}0.26%$ and $0.30{\pm}0.26%$ for photon and electron beams, respectively. QA Beamchecker PLUS beam outputs were $0.31{\pm}0.24%$ and $0.33{\pm}0.24%$ for photon and electron beams, respectively. The Pearson correlation coefficient between MPC and QA Beamchecker PLUS indicated that photon beams were very strong at 15 MV, and strong at 6 MV, 10 MV, 6 MV-FFF and 10 MV-FFF. For electron beams, the Pearson correlation coefficient were strong at 16 MeV and 20 MeV, moderate at 9 MeV and 12 MeV, and very weak at 6 MeV. Conclusion: MPC showed significantly strong correlation with QA Beamchecker PLUS when testing with photon beams and high-energy electron beams in the evaluation of daily beam output, but the correlation when testing with low-energy electron beams (6 MeV) appeared to be low. However, MPC and QA Beamchecker PLUS are considered to be suitable for checking daily beam output, as they performed within 2 % of beam output consistency during the observation. MPC which can perform faster than the conventional daily beam output measurement tool, is considered to be an effective method for users.

  • PDF