• Title/Summary/Keyword: Measuring methods

Search Result 4,454, Processing Time 0.037 seconds

A Study on Improvement in a Method of Three Dimensional Configuration Scan Measurement (3차원 형상 스캔의 측정방법 개선에 관한 연구)

  • 김태호;김민주;이승수;박정보;전언찬
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.375-380
    • /
    • 2001
  • This study is on the precision of the optical scanner which is suitable for shape modeling and non-contact equipment, comparing with a razer scanner. The optical scanner not only has all merits that non-contact methods have but also improve a veil phenomenon which is a razer scanner's demerits. However, the optical scanner has not been used extensively because the measurements are not very precise and there are not the definite methods of measurement. Hence, this study is to find out how parameters such as camera's hight, angle, luminous intensity, distance to object, and so on have an influence on measuring using the optical scanner and to establish the methods of measuring precision.

  • PDF

Methods of Evaluating Efficacy of Hair Growth Following Treatment for Alopecia in Oriental Medicine (한의학적 탈모 치료효과의 객관적 평가 방법)

  • Moon Jung-Bae;Kim Young-Jin;Yi Tae-Hoo
    • The Journal of Korean Medicine
    • /
    • v.27 no.2 s.66
    • /
    • pp.57-69
    • /
    • 2006
  • For decades, scientists and clinicians have examined methods of measuring scalp hair growth. There has been a greater need for reliable, economical and minimally invasive means of measuring hair growth and, specifically, response to Oriental medicine therapy. We review the various methods of measurement described to date, their limitations and value to the clinician. In our opinion, the potential of computer-assisted technology in this field is yet to be maximized and the currently available tools are less than ideal. The most valuable means of measurement at the present time are global photography and phototrichogram-based techniques (with digital image analysis). Subjective scoring systems are also of value in the overall assessment of response to therapy and these are under-utilized and merit further refinement.

  • PDF

A Study on Three-dimensional Configuration Scan by Photographing Parameter (촬영 매개변수에 의한 3차원 형상스캔에 관한 연구)

  • 이승수;김세민;김민주;박정보;전언천
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.1013-1017
    • /
    • 1997
  • This study is on the precision of the optical scanner which is suitable for shape modeling and non-contact equipment, comparing with a razer scanner. The optical scanner not only has all merits that non-contact methods have but also improve a veil phenomenon which is a razer scanner's demerits. However, the optical scanner has not been used extensively because the measurements are not very precise and there are not the definite methods of measurements, Hence, this study is to find out how parameters such as camera's hight, angle, luminous intensity, distance to object, and so on have an influence on measuring using the optical scanner and to establish the methods of measuring precision.

  • PDF

A Study on Improvement of the Measurement Method for Optical Scanner (광학식 스케너의 측정방법 개선에 관한 연구)

  • Joo, M.S.;Kim, M.J.;Lee, S.S.;Kim, S.K.;Jeon, E.C.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.841-847
    • /
    • 2001
  • This study is on the precision of the optical scanner which is suitable for shape modeling and non-contact equipment, comparing with a razer scanner. The optical scanner not only has all merits that non-contact methods have but also improve a veil phenomenon which is a razer scanner's demerits. However, the optical scanner has not been used extensively because the measurements are not very precise and there are not the definite methods of measurement. Hence, this study is to find out how parameters such as camera's hight, angle, luminous intensity, distance to object, and so on have an influence on measuring using the optical scanner and to establish the methods of measuring precision.

  • PDF

A Study on the Computerization of Anthropomorphic Data (인체 형상 자료의 전산화에 관한 연구)

  • Lee, Geun-Bu
    • Journal of the Ergonomics Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.23-30
    • /
    • 1988
  • The methods suggested up to now for 3-dimensional anthroponetry require much efforts and costs in measuring and analysing. To solve these problems, we adopt the methods such as Moire Interferometry, Image processing and Computer Vision Technique which are efficient in processing anthropomorphic data. Moire contourgraph was constructed by using Ar-ion laser as a light source (2 Watt power and 5145 A wavelength) and laser beam expander(20X). Image data can be 3-dimensionally reconstructed as the surface patch and geographical relation between faces expressed by mash-point and edges as units. This research is focused on the followings; 1) Development of an economical and reliable measuring method. 2) Design of reproduction methods of 3-dimensional human body data. Therefore, our research makes it possible to study further advanced quantitative analysis of human body.

  • PDF

Methods of measuring presynaptic function with fluorescence probes

  • Yeseul Jang;Sung Rae Kim;Sung Hoon Lee
    • Applied Microscopy
    • /
    • v.51
    • /
    • pp.2.1-2.7
    • /
    • 2021
  • Synaptic vesicles, which are endogenous to neurotransmitters, are involved in exocytosis by active potentials and release neurotransmitters. Synaptic vesicles used in neurotransmitter release are reused via endocytosis to maintain a pool of synaptic vesicles. Synaptic vesicles show different types of exo- and endocytosis depending on animal species, type of nerve cell, and electrical activity. To accurately understand the dynamics of synaptic vesicles, direct observation of synaptic vesicles is required; however, it was difficult to observe synaptic vesicles of size 40-50 nm in living neurons. The exo-and endocytosis of synaptic vesicles was confirmed by labeling the vesicles with a fluorescent agent and measuring the changes in fluorescence intensity. To date, various methods of labeling synaptic vesicles have been proposed, and each method has its own characteristics, strength, and drawbacks. In this study, we introduce methods that can measure presynaptic activity and describe the characteristics of each technique.

Measurement of deuterium concentration in heavy water utilizing prompt gamma neutron activation analysis (PGNAA) in comparison with MCNPX simulation results

  • Saeed Salahi;Mahdieh Mokhtari Dorostkar ;Akbar Abdi Saray
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4231-4235
    • /
    • 2022
  • Considering the importance of deuterium in nuclear science including medical and industrial researches such as (BNCT) and nuclear reactors respectively, it is important to study various possible ways in addition to common methods for measuring its concentration. This study is an effort to measure deuterium concentration using PGNAA. The main idea is to calculate the area under 2.23 MeV gamma-rays photo peak resulting from neutron collision with Hydrogen atoms which are in mix with deuterium in samples. The study carried out by both simulation and experiment. Monte Carlo MCNPX2.6 code has been used for simulation and based on its acceptable results an experimental setup has been arranged. The coordination of results was in the range of R = 0.99 and R = 0.98 in simulation and experiment respectively. The accuracy of the study has been investigated by measuring the concentration of an unknown sample by both PGNAA and Fourier transform infrared spectroscopy (FT-IR) methods in which there were acceptable correlation between these two methods.

Study on methodology for the assessment of internal and marginal adaptation on fixed dental prosthesis (고정성 보철물의 내면 및 변연적합도를 평가하는 방법에 대한 고찰)

  • Pyo, Se-Wook;Lee, Jun-Jae;Han, Jung-Suk;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.158-168
    • /
    • 2016
  • This article is to review various methods used to investigate internal and marginal adaptation of fixed dental prostheses, and to summarize a merit, worth, and limitation of each method, using some results of previous studies. The methods of measuring internal and marginal gap are divided into two categories in this study; in vivo and in vitro. In vivo methods are clinical evaluations, including exploration, radiography, and impression technique. In vitro methods are laboratory evaluations such as direct view, cross-sectioning, and silicone replica technique using microscope. Measuring by micro computed tomography (CT) or profilometer is also in vitro methods. In recent years, the development of scanning systems is able to analyze 3-dimensional internal and marginal space in detail. As measuring and analyzing technology become more advanced, the ability to thoroughly examine crown adaptation is becoming both simpler and more efficient.

Development of Two-Finger Force Measuring System to Measure Two-Finger Gripping Force and Its Characteristic Evaluation (단축 힘센서를 이용한 두 손가락 잡기 힘측정장치 개발 및 특성평가)

  • Kim, Hyeon-Min;Shin, Hi-Suk;Yoon, Joung-Won;Kim, Gab-Soon
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.172-177
    • /
    • 2011
  • Finger patients can't use their hands because of the paralysis their fingers. Their fingers are recovered by rehabilitating training, and the rehabilitating extent can be judged by measuring the pressing force to be contacted with two fingers(thumb and first finger, thumb and middle finger, thumb and ring finger, thumb and little finger). At present, most hospitals have used a thin plastic-plate for measuring the two-finger grasping force, and we can only judge that they can grasp the plate with their two-finger through it, because the plate can't measure the two-finger grasping force. But, recently, the force measuring system for measuring two-finger grasping force was developed using three-axis force sensor, but it is very expensive, because it has a three-axis force sensor. In this paper, two-finger force measuring system with a one-axis force sensor which can measure two-finger grasping force was developed. The one-axis force sensor was designed and fabricated, and the force measuring device was designed and manufactured using DSP(Digital Signal Processing). Also, the grasping force test of men was performed using the developed two-finger force measuring system, it was confirmed that the grasping forces of men were different according to grasping methods, and the system can be used for measuring two-finger grasping force.