Proceedings of the Korean Society of Machine Tool Engineers Conference (한국공작기계학회:학술대회논문집)
- 2001.10a
- /
- Pages.375-380
- /
- 2001
A Study on Improvement in a Method of Three Dimensional Configuration Scan Measurement
3차원 형상 스캔의 측정방법 개선에 관한 연구
Abstract
This study is on the precision of the optical scanner which is suitable for shape modeling and non-contact equipment, comparing with a razer scanner. The optical scanner not only has all merits that non-contact methods have but also improve a veil phenomenon which is a razer scanner's demerits. However, the optical scanner has not been used extensively because the measurements are not very precise and there are not the definite methods of measurement. Hence, this study is to find out how parameters such as camera's hight, angle, luminous intensity, distance to object, and so on have an influence on measuring using the optical scanner and to establish the methods of measuring precision.