• 제목/요약/키워드: Measuring control standard

검색결과 199건 처리시간 0.024초

피부탄성 측정 문제점 개선을 위한 6시그마 프로젝트 (A Case Study of Six Sigma Project for Improving Measurement Method of Skin Elasticity)

  • 이혜정;강남식;전영주;김근호;김홍기;김종열
    • 한국한의학연구원논문집
    • /
    • 제16권3호
    • /
    • pp.135-140
    • /
    • 2010
  • The usefulness of constitutional diagnoses based on skin measurements has been established in oriental medicine. According to Sasang constitutional medicine, humans can be distinguished based on properties of skin's friction, thickness and elasticity. To quantify and standardize skin diagnosis, the present study designed an equipment for measuring skin elasticity of hand. But there were some noises in measuring skin elasticity such as measurement method, environment, operator and conditions of patient. So we considered a six sigma project for reducing the measurement errors. The project was followed to discipline process of five macro phases: Define, Measure, Analyze, Improve and Control(DMAIC). So, we could find the major factors which should be controled for stabilizing measurement system and we revised the SOP(Standard Operating Procedure) of the skin elasticity measurement.

폐광지역 지반공사시 지반침하 관리를 위한 기준 (Standards for Ground Settlement Management when Reinforcing Ground in the Abandoned Mine)

  • 양인재;이승아;백동호
    • 터널과지하공간
    • /
    • 제27권5호
    • /
    • pp.295-302
    • /
    • 2017
  • 본 연구에서는 폐광지역 지반침하 관리시 토목분야(도로, 철도 등)의 계측관리기준을 그대로 준용하고 있는 현행 계측수행 상의 문제점을 개선하기 위해 광산분야에서 적용할 수 있는 새로운 정량적 계측관리기준을 제시하였다. 광해관리공단의 협조를 얻어 폐광지역에서 수행된 지반침하 관련 자료들을 수집하였고, 이 중 현장에서 실측된 수동계측자료들을 토대로 새로운 계측관리기준치 설정에 대한 여러 기법들에 대해 연구하였다. 그 결과, 계측치들의 평균값, 3사분위수, 95% 신뢰도, 최대값 등의 통계량을 통해 계측항목별 계측관리기준치를 설정, 제안하였다.

적혈구 용적률 간섭 보정을 위한 혈당 측정 기기의 설계 및 구현 (Design and Implementation of a Blood-Glucose Meter to Reduce Hematocrit Interference)

  • 조현태
    • 대한임베디드공학회논문지
    • /
    • 제15권4호
    • /
    • pp.167-175
    • /
    • 2020
  • A blood-glucose meter is one of the in vitro diagnostic devices to measure and control the glucose concentration of diabetics. In order to measure the glucose level in the blood, the common method is to measure the amount of electrons, that is, the output current generated by glucose oxidation after a blood sample is inserted into the test strip containing an enzyme. The hematocrit is an obstacle in measuring accurate blood glucose concentration. This paper deals with the design and implementation of a blood-glucose meter to correct the hematocrit interference. We propose a sequential method which measures impedance using the alternating current and then measures glucose in the blood using the direct current. In addition, this paper introduces how to use commercial glucose strips based on the proposed system. Finally, we conducted the performance evaluation of the proposed system by comparing the measured current and impedance with those of the references. As a result, the standard deviation of the current measurement is approximately 0.6nA and the impedance measurement error for measuring the hematocrit is approximately within 1%. The proposed system will improve the accuracy of the conventional blood-glucose meter by reducing the hematocrit interference.

흰쥐에서 족삼리 취혈 위치 표준화를 위한 연구 (The Study to standardize the ST36 Acupoint Location on Rats)

  • 김종엽;최일환;홍요한;임사비나
    • Korean Journal of Acupuncture
    • /
    • 제27권3호
    • /
    • pp.97-108
    • /
    • 2010
  • Background : The location of acupoints on rat, which may differ from that of human body due to anatomical structure, is defined variously among researchers, which may cause the problem of low repeatability and objectivity. Design : The measurement of hind limb consist of measuring the distance between knee joint and tibia tubercle in order to set the knee joint as common criteria. Based on it, the three mostly referred location of ST36 were represented with the knee joint as a datum point and compared. The electroacupuncture stimulation was administrated after the abdominal pain was induced by acetic acid. And the analgesic activity of each ST36 acupoint was evaluated by measuring the number of writhing reflex, in order to observe the differences of treatment effect in accordance with the location of ST36 acupoints. Results : The result of measurement confirmed the differences in the acupoint location of ST36 among researchers. The writhing reflex test using the acetic acid-induced abdominal pain stimulated with electroacupuncture of 100Hz showed that there were statistically significant differences in the analgesic effect between control group and three ST36 groups (P<0.05). However there were no differences observed among three mostly referred location of ST36 acupoints (P>0.05). Conclusions : We recommend "the point located 6.5 mm below the knee joint at the anterior tibial muscle" as a standard ST36 acupoint location qualified by the WHO Standard Acupuncture Point Locations in 2008.

유탕면류의 유탕공정 중 중요관리점(CCP)을 위한 미생물학적, 화학적 위해요소분석 (Biological and Chemical Hazards Factor Analysis for CCP(Critical Control Point) in Fried Process of Fried Noodles)

  • 권상철
    • 한국산학기술학회논문지
    • /
    • 제13권8호
    • /
    • pp.3578-3585
    • /
    • 2012
  • 유탕면류의 HACCP(Hazard Analysis Critical Control Point) 시스템 구축을 위하여 유탕 공정-CCP(Critical Control Point)에 대한 미생물학적(Biological hazards)과 화학적(Chemical hazards) 한계 기준 설정을 위한 목적으로 수행하였으며, 경기도 이천 소재의 P사에서 실행하였다. 유탕공정은 각각의 시간과 온도 측정에 따라 미생물학적, 화학적 위해요소를 제거하거나 감소에 대해 실험하였다. 실험결과 Standard plate count와 식중독균은 유탕공정(Temperature : $145{\pm}10^{\circ}C$, Time : $75{\pm}30$ sec)에 의해 검출되지 않았다. 유탕공정에 의해 생성되는 화학적 위해 기준의 산가는 법적 기준치인 0.6보다 낮은 0.2 이하였다. 증숙실과 유탕실의 공중낙하균을 측정한 결과 3 CFU/mL, 3 CFU/mL 검출되었다. 따라서 유탕공정의 CCP-BC는 일반세균과 식중독균, 산화생성물 생성을 예방, 제거하는데 좋은 대안책이 될 것이다. 결론적으로 HACCP을 위해 유탕공정에 대한 한계기준설정, 모니터링방법, 개선조치, 검증방법, 교육, 기록관리가 필요하다고 생각된다.

소규모 이더넷 스위치에서 개선된 적응적 전력 제어 메커니즘 (An Enhanced Adaptive Power Control Mechanism for Small Ethernet Switch)

  • 김영현;이성근;고진광
    • 한국전자통신학회논문지
    • /
    • 제8권3호
    • /
    • pp.389-395
    • /
    • 2013
  • 이더넷은 전 세계적으로 가장 널리 배치되어 사용되는 가입자망 네트워킹 기술이다. 이더넷의 에너지 효율성을 향상시키기 위해 IEEE 802.3az WG에서 LPI 기반의 EEE 규격을 확정하였다. 본 논문은 소규모 이더넷 스위치에서 EEE 를 기반으로 에너지 효율을 향상시킬 수 있는 개선된 적응적 전력 제어 메커니즘을 제안한다. 본 메커니즘의 특징은 일정기간 유입되는 트래픽 양을 측정하여 다음 주기의 트래픽 특성을 예측하고, 해당 트래픽 부하에 최적의 threshold 값을 조정한다. 성능분석 결과는 본 논문에서 제안한 메커니즘이 기존 방법에 비해서 평균 패킷 지연은 약간 증가시키지만 에너지 소비율을 상당히 감소시키므로 전반적으로 성능을 향상시키는 것으로 나타났다.

단락시간비를 이용한 GMAW의 비드 높이 제어에 관한 연구 (A Study on Bead Height Control of GMAW by Short Circuit Time Ratio)

  • 감병오;조상명;김상봉
    • 한국해양공학회지
    • /
    • 제16권2호
    • /
    • pp.53-59
    • /
    • 2002
  • This paper shows the experimental results controlling the height of surface and back bead in GMAW by analyzing the unexpected gaps between base metals produced in welding and by controlling welding velocity due to the variation of the gap between base metals in thin-plate welding. The back bead behavior and burn-through in I-type butt joint $CO_2$ welding of thin mild steel are analyzed in the views of short circuit time ratio and short circuit frequency. It is shown through experimental consideration that the short circuit time ratio method is more reasonable than the short circuit frequency method in analyzing the formulation of back bead under changing the gap between base metals. Based on the these results, welding manipulator is designed so as to satisfy the bead height control in real time by measuring the short circuit time ratio. To show the effectiveness of the developed bead formulation control system, the experiment is implemented under two welding conditions such as increasing gap from 0mm to 0.8mm and gradually increasing gap from 0mm to 1.2mm. The experimental results show that the bead formulation can be controlled uniformly in spite of the variation of the gap between base metals.

피부 치료 시스템이 성인 아토피 피부염에 미치는 영향에 대한 조사 연구 (A Study of the Effects of Systemic Skin Care as a Adjunct Treatment for Adult Atopic Dermatitis)

  • 송다해
    • 한국패션뷰티학회지
    • /
    • 제3권3호
    • /
    • pp.41-47
    • /
    • 2005
  • This study was conducted with 60 adult males who visited the Atomi Cooperative Clinic(Atomi Dermatology/Pediatrics/Oriental Clinic) in Seoul between May 2003 and December 2004; they were divided into three groups, each of which consisted of 20 persons, according to the level of erythma and then each group was subdivided to consist of ten according to whether they received skin treatment and care. The standard care provided to two groups involved topical steroids and oriental medicines prescribed by a dermatologist and a oriental doctor, respectively. 5th-grade topical steroid ointment was applied to the face and 3rd-grade to the limbs; a oriental medicine was administered in a lukewarm state half an hour after meals three times a day. To determine how special and systematic skin treatment and care was helpful in treating atopy, a skin treatment system was applied to the experimental group while the control group was provided with standard care alone. By using Mexameter(MX18) manufactured by ck-mpa as a measuring tool, the inflammation level was observed at the right antecubital space during each visit to the clinic. In view of the re suits, introduction of the systemic skin care for A. D to legitimate treatment provided by a medical institution is expected to be an appropriate supplementary treatment for adult patients who suffer from frequent recurrence of atopic dermatitis.

  • PDF

지구단위계획(地區單位計劃)에서 건축(建築) 규모설정(規模設定)에 관한 연구(硏究) (A study on the suitable of building size in district units plan)

  • 이원근;이재국;도규환
    • 한국디지털건축인테리어학회논문집
    • /
    • 제3권1호
    • /
    • pp.39-49
    • /
    • 2003
  • The height provisions, by the urban planning, describe the hightest height per width division, also define oblique line limitation by road without mentioning the highest per width division. Therefore this study will be a basic model for the standard of measuring the highest height per width division analysizing the propriety of current standard of oblique limitation. This technique is prepared to prevent the confusion and to complements the existing planning method. Therefore, it takes more time to establish this new method and to apply it to the existing condition. This study reviewed density control in District Units Plan, based on the guidelines of density, which included height, ratio of total floor to ground area, and land distribution. This study aims to provide efficient analysis by using current oblique limitation provisions Thus, proving the area rations of general residential areas are decreasing. Since the purpose of the District Units Plan is to avoid confusion and help ease the existing problematic conditions which have risen from the two above-mentioned conventional systems, further observation and research on these areas are necessary.

  • PDF

Chlorella의 생리적, 생화학적 제활성에 미치는${\gamma}$-선의 영향

  • 이영록
    • Journal of Plant Biology
    • /
    • 제7권3호
    • /
    • pp.9-14
    • /
    • 1964
  • The sensitivities of Chlorella ellipsoidea to ${\gamma}$-ray from Cobalt-60 were determined by measuring the photosynthetic and respiratory activities and the changes in phosphate contents in various fractions of the irradited cells, which were further grown in a standard medium after irradiation, were compared to those of non-irradiated normal cells. The photosynthetic and repiratory activities of the cells were almost inversely proportional to the dose of ${\gamma}$-ray irradiated and the photosynthetic activity was more sensitive than the respiratory activity of the cells. The most sensitive to ${\gamma}$-ray was growth activity, followed by photosynthesis, exogenous and endogenous respirations of the cells in decreasing order. Chlorella cells were so resistant to ${\gamma}$-ray comapred with other organisms that about 280,000 r dose of ${\gamma}$-ray irradiaton was necessary to reduce as much as half the subsequent photosynthetic activity. When the irradiated algae were further cultured in a standard medium, the phosphate contents in the fraction of DNA, RNA and phosphoprotein decreased considerably compared with those of non-irradiated normal cells, while the phosphate contents in the fraction of polyphosphates increased than those of control. Therefore, it was deduced that ${\gamma}$-ray inhibited the synthesis of DNA from polyphosphates, that the growth of Chlorella cells were consequently retarded.

  • PDF