• 제목/요약/키워드: Measuring Tip

검색결과 212건 처리시간 0.024초

축류팬 익단누설와류의 비정상 특성 (Unsteady Nature of a Tip Leakage Vortex in an Axial Flow Fan)

  • 장춘만;김광용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.845-850
    • /
    • 2003
  • Unsteady nature of a tip leakage vortex in an axial flow fan operating at a design and off-design operating conditions has been investigated by measuring the velocity fluctuation in a blade passage with a rotating hotwire probe sensor. Two hot-wire probe sensors rotating with the fan rotor were also introduced to obtain the cross-correlation coefficient between the two sensors located in the vortical flow as well as the fluctuating velocity. The results show that the vortical flow structure near the rotor tip can be clearly observed at the quasi-orthogonal planes to a tip leakage vortex. The leakage vortex is enlarged as the flow rate is decreased, thus resulting in the high blockage to main flow. The spectral peaks due to the fluctuating velocity near the rotor tip are mainly observed in the reverse flow region at higher flow rates than the peak pressure operating condition. However, no peak frequency presents near the rotor tip for near stall condition.

  • PDF

표면거칠기 측정용 다이아몬드 촉침의 마모에 관한 연구 (A Study on the Wear of Diamond Stylus for Surface Roughness Measurement)

  • 한응교;노병옥;박두원;김종억
    • 한국정밀공학회지
    • /
    • 제8권3호
    • /
    • pp.105-113
    • /
    • 1991
  • The practicability of Ion-Sputter machining renders it possible to make diamond stylus for surface roughness measurement with micro stylus tip radius less than 2${\mu}mR$, and to measure surface roughness of fine-machined surface. In this study, we researched the wear or Ion-Sputtered stylus with 0.1${\mu}mR$ and 0.5${\mu}mR$ for micro-figure measurement and polished stylus with 0.5${\mu}mR$ according to measurement distance. As a result, we know that the case of Ion-Sputtered stylus is worn down easilier the case of polished stylus. And we know that in the evaluation of stylus wear, it is more useful method that examine the wear by measuring the variation of stylus tip radius than by evaluating the variation of Ra values.

  • PDF

공기조화기용 스크롤 압축기의 플랭크 및 팁실 누설특성 (Characteristics of Flank and Tip Seal Leakage in a Scroll Compressor for Air-Conditioners)

  • 윤영;김용찬;민만기
    • 설비공학논문집
    • /
    • 제13권2호
    • /
    • pp.134-143
    • /
    • 2001
  • This paper presents the characteristics of flank and tip seal leakage in a scroll compressor for air-conditioners with R-22 under actual operating conditions. It is well known that the leakage has significant effect on the performance of the scroll compressor. Experiments were performed by using indirect method for measuring mass flow rate passing through flank and tip seal under actual operating conditions, In addition, an analytical model for tip seal leakage was developed to investigate tangential and radial leakage observed at grooves and contact points of tip seals. For low oil concentration, theoretical results were compared with experimental data to verify the analytical model. As a result, leakages through flank and tip seal parts were evaluated as afunction of pressure ratio, orbiting angle, discharge pressure, tip clearance, and leakage point. It was also found that the tip seal leakage was considerable even though the tip seal provided adequate sealing effect.

  • PDF

복강경 수술용 로봇 인스트루먼트의 간접적 작동력 측정법에 관한 연구 (Study for the Indirect Measuring Method of Operational Force in Surgical Robot Instrument)

  • 김지언;이민철;이태경;최승욱;박민규
    • 제어로봇시스템학회논문지
    • /
    • 제16권9호
    • /
    • pp.840-845
    • /
    • 2010
  • This paper proposes the method indirectly measuring the operating force of the end-effect tip of surgical robot instrument which conducts the surgical operation in the body on behalf of the surgeon's hand. Due to the size and safety obligation to the surgical robot instrument, it is difficult to measure the operation force of its tip like grasping force. However the instrument is driven by cable-pulley torque transmission mechanism and when some force is occurred at the tip, then the reaction force appears on the cable as additional tension. Based on this phenomenon, this paper proposes a method to estimate the operating force from measuring reaction force against the driving motor by using a loadcell. And it induces mathematical equation to calculate the force from loadcell by approaching the modulus of elasticity to high order polynomial. And this paper proves the validity of proposed mechanism by experimental test.

직접측정법을 이용한 혼합모드 하중 하에서 피로균열의 닫힘과 전파거동 (Fatigue Crack Closure and Propagation Behavior Under Mixed-Mode Loading Observed by the Direct Measuring Method)

  • 송삼홍;서기정;이정무
    • 한국정밀공학회지
    • /
    • 제22권6호
    • /
    • pp.152-158
    • /
    • 2005
  • The stress conditions acting on the practical structure are complex, and thus most cracks existing in the practical structures are under mixed-mode loading conditions. The effect of shear load component of mixed-mode loading acts more greatly in the stage of crack initiation and initial propagation than crack propagation stage. Hence, research on the behavior in the stage of crack initiation and initial propagation need to be examined in order to evaluate behavior of mixed-mode fatigue cracks. In this study, the crack tip displacement(CTD) was measured by using the direct measuring method(DMM). We examined the behavior at crack tip by determining crack opening load$(P_{op})$. From the test results, the propagation behavior of mixed-mode fatigue cracks was evaluated by considering mixed-mode crack closure. Also, we examined the characteristic of crack propagation under mixed-mode loading with crack propagation direction.

유량에 따른 축류홴의 익단누설와류 특성 (Flow Characteristics of a Tip Leakage Vortex at Different Flow Rates in an Axial Flow Fan)

  • 장춘만;김광용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1383-1388
    • /
    • 2004
  • The flow characteristics in the blade passage of a low speed axial flow fan have been investigated by experimental analysis using a rotating hot-wire sensor for design and off-design operating conditions. The results show that the tip leakage vortex is moved upstream when flow rate is decreased, thus disturbing the formation of wake flow near the rotor tip. The tip leakage vortex interfaces with blade pressure surface, and results in high velocity fluctuation near the pressure surface. From the relative velocity distributions near the rotor tip, large axial velocity decay is observed at near stall condition, which results in large blockage compared to that at the design condition. Througout the flow measurements using a quasi-orthogonal measuring points to the tip leakage vortex, it is noted that the radial position of the tip leakage vortex is distributed between 94 and 96 percent span for all flow conditions. High spectrum density due to the large fluctuation of the tip leakage vortex is observed near the blade suction surface below the frequency of 1000 Hz at near stall condition.

  • PDF

혼합모드 하중 하에서의 균열성장 중 피로파단면 마찰과 균열닫힘효과의 상호관계 (The Correlation between Fatigue Fracture Crack Surface Friction and Crack Closure Effect in Crack Growth under Mixed-mode loading)

  • 서기정;송삼홍;이정무
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.214-219
    • /
    • 2004
  • Crack tip behavior of single mode loading condition(mode I)depend on tensile loading component but one of mixed mode loading condition(mode I+II) have influenced on shear loading component like the practical structure. Because crack closure is caused by shear loading component under mixed-mode loading a research on the behavior in the stage of crack initiation and propagation require to be evaluate about crack closure effect by fatigue crack surface friction. For that reasion we examined the behavior at the crack tip by direct measuring method. Measured behavior at the crack tip was analyzed through vector crack tip displacement. As a result, crack propafation equation was corrected by considering with crack closure effect. In addition we compared fatigue fracture crack surface and crack closure level.

  • PDF

촉침에 의한 표면 거칠기 측정 오차 해석 (Analysis of Measuring Error of Surface Roughness by Contact Stylus Profilometer)

  • 조남규;권기환
    • 한국정밀공학회지
    • /
    • 제16권12호
    • /
    • pp.174-181
    • /
    • 1999
  • This paper describes the effect of the stylus tip size on the shape error in surface topography measurement. To analyze the distortional effect of an actual surface geometry origination from the finite stylus size, the surface is modeled as a sinusoid and the stylus tip as a circle. The magnitude of this distortion is defined as the ration of standard deviation, and this is expressed as an analytic function of the stylus tip radius and the geometrical parameter of a sinusoid. In this paper, the spectrum analysis of the profile is applied to investigate the distortional effect due to the mechanical filtering of the stylus in the frequency domain. and, the cumulative power spectrum is proposed to assess the shape error of measured data according to the various stylus tip sizes. From these results, a new method to select proper stylus tip radius is proposed.

  • PDF