• Title/Summary/Keyword: Measuring Space

Search Result 851, Processing Time 0.024 seconds

Cutting Force Measuring System Using the Load Cell for a Milling Process (로드셀을 이용한 밀링 가공시의 절삭력 측정시스템)

  • Kang, E. G.;Park, S. J.;Lee, S. J.;Kwon, H. D.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.6
    • /
    • pp.133-140
    • /
    • 2001
  • This paper suggests another system for a cutting force measuring tool in a milling process. Generally, tool dynamometer is taken into account for the most appropriate cutting force measuring tool in the analysis of cutting mechanism. However, high price and limited space make it difficult to be in-situ system for controllable milling process. Although an alternative method using AC current of servo-motor has been suggested, it is unsuitable for cutting force control because of small upper frequency limit and noise. The cutting force measuring system is composed of two load cells placed between the moving table bracket and the nut flange part of ballscrew. It has many advantages such as low cost and wide range measurement than tool dynamometer because of the built-in moving table and the low cost load cell. The static and dynamic model of the measuring system using imbeded load cell is introduced. Various Experiments are carried out to validate both models. By comparing the cutting forces from a series of end milling experiments on the tool dynamometer and the system developed in this paper, the accuracy of the cutting force measuring system is verified. Upper frequency limit is measured by the experiment of dynamic characteristics.

  • PDF

A Study on the Method of Measuring Accessibility to Urban Open Spaces (도시 오픈스페이스의 접근성 측정에 관한 연구)

  • 안동만;최형석;김인호;조형준
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.18 no.4
    • /
    • pp.17-28
    • /
    • 1991
  • The purpose of this study is to investigate and present a method for measuring public accessibility to urban open spaces. A basic assumption is that, for urban open space policies, accessibility is more important than per capita area. In this study, for the purpose of simplicity, a residential area is assumed to have access to open space if it is within a certain distance from an urban open space. Official city planning map is overlayed with a 200m grid and each cell of dwelling area is checked whether it is within a certain distance from a cell categorized as urban open space. A computer program for widely commercialized personal computer is developed for data processing so that local governments without access to more sophisticated systems can carry out similar studies for their own jurisdictions. Five cities, big, small, old and new, are selected to test the proposed method. Dwelling areas of Ansan new Town have highest accessibility to open spaces(93.4% of dwelling cells have open space cell within 500m). Seoul (91.2%), Suwon(78.2%), Pusan(73.8%), and Inchon(61.4%) have less accessibility. If we assume the Ansan City residents are evenly distributed over the dwelling area, 93.4% of the population has open spaces within walking distance of 500m. However, if we consider physical barriers such as arterial roads, railroads, and streams that reduce the accessibility, less than 93.4% of Ansan city residents enjoy good access to open spaces. Though a further detailed analysis is needed to picture the microscopic accessibility, this method can serve as a useful tool for urban open space policy and open space alternatives evaluations.

  • PDF

Method for Measuring Dielectric Constant of Planar Dielectric Substrate (판형 유전체의 유전율 측정 방법)

  • Lee, Chang-Hyun;Kwon, Taek-Sun;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.10
    • /
    • pp.799-804
    • /
    • 2018
  • In this paper, a method for measuring the dielectric constant of a planar dielectric substrate using the free space material constant measurement method in a general measurement environment is proposed. Two horn antennas and a network analyzer were used for S-parameter measurement and the transmission and reflection coefficients of a planar dielectric substrate were calculated from the measurement results. To obtain a reliable dielectric constant in a low-precision-measurement environment, only the magnitude of the transmission coefficient, which has a small error due to the measurement environment, is used for dielectric constant estimation. Finally, the dielectric constant is determined by comparing the measured results at different frequencies.

Object Position Measuring System using Trilateration Method based on Illuminance of LED (LED의 조도를 기반으로 삼각측량법을 사용한 물체 위치 계측 시스템)

  • Sagong, Byung-Il;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.3
    • /
    • pp.449-455
    • /
    • 2022
  • In this paper, we propose a position measuring system using trilateration based on the illuminance of a light-emitting diode (LED). Three LEDs are located on the ceiling of the virtual space, and each fixed coordinate is inputted to the monitoring program, and Length to the illuminance sensor is drawn through the relational expression of the length and illuminance value from the respective LED. Based on the derived length, the trilateration method is used to find object location information in virtual space. By using the least square equation to minimize the error of the length drawn to trilateration, the error is reduced to the utmost. Unlike the existing indoor positioning system using visible light communication (VLC), the proposed system does not require synchronization between the transmitter and the receiver, so the system can be configured simply.

Calibration and INvestigation into Measurement Performance of a Visual Sensing System (시각측정시스템의 캘리브레이션 및 측정성능 검토)

  • Kim, Jin-Young;Cho, Hyung-Suck
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.8
    • /
    • pp.113-121
    • /
    • 1999
  • It is necessary to calibrate measurement systems to enhance its measurement accuracy. The visual sensing system that is presented in our previous work has to be calibrated, too. It is a multiple mirror system for three-dimensional measurement, which is composed of a camera and a series of mirrors. It is important to calibrate the positions and orientations of the mirrors relative to the camera because they have direct influence on the relationship between the image plane and the task space. This paper presents the calibration method for the visual sensing system. To confirm the measurement performance of the implemented system. its measurement accuracy in measuring the locations in three-dimensional space is investigated. A series of experiments for measuring the locations of the circle-shaped marks are performed. Experimental results show that the sensing system can be effectively used for three-dimensional measurement.

  • PDF

Improved spectral line measurements of the SDSS galaxy spectra

  • Oh, Kyu-Seok;Sarzi, Marc;Yi, Suk-Young
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.35.1-35.1
    • /
    • 2009
  • We have established a database of galaxy spectral line strengths for the SDSS database using an improved line measuring method. Our work includes the entire SDSS DR7 galaxies within redshift of 0.2. The absorption line strengths measured by the SDSS pipeline are seriously contaminated by emission filling. Our code, GANDALF (gas and absorption line fitting code) performs more accurate measurements by effectively separating emission lines from absorption lines. A significant improvement has also been made on the velocity dispersion measurement, more notably in late-type galaxies. We have also identified a number of broad line region galaxies which were misclassified as normal galaxies by the SDSS pipeline. We developed an effective method measuring their line strengths. The database will be provided with new parameters that are indicative of the line strength measurement quality. In addition, we made galaxy templates for the Hubble sequence. The database will be useful for many fields of galaxy studies including star formation and AGN activities.

  • PDF

Position of the Fist Cervical Vertebra in Relation to Cervical Curvature (제 1경추골의 위치와 경추만곡도 간의 관계)

  • Moon-Il Her;Kyung-soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.1
    • /
    • pp.197-206
    • /
    • 1996
  • This study ws performed to investigate the relationship between cervical curvature and the spatial position of the posterior part of the atlas imaged in the lateral cephalograph. Sixty six patients with temporomandibular disorders(TMD) and twenty dental students were selected for patients group and control group, respectively. The average age of patients group was 26.3 years, and 24.9 years in control group. Measured variables were cervical depth, upper space between the atlas and the base of the occiput, lower space between the atlas and the spinous process of the axis, rea of the posterior part of the atlas imaged in the lateral cephalograph, and the cervical curvature passing through the uppermost point in dorsal side of Dens of the Axis to the lowermost and rearmost point of the 5th cervical vertebra. The reliability of the method used for measuring cervical curvature with curved ruler was also tested. The results obtained were as follows : 1. Cervical depth of patients group was 122.9mm and significantly shorter than that of control group, in which cervical depth was 131.9mm, and cervical depth was significantly correlated with other variables in all subjects. 2. Upper space was greater in patients group, but total space including upper and lower space showed no difference between the two groups. The average value of total space was 26.5mm. 3. Area of the posterior part of the atlas was 168.2$\textrm{mm}^2$ in patients group, and 186.5$\textrm{mm}^2$ in control group with significant difference between the two groups. 4. Average range of radius of cervical curvature were 33-40cm and there was no difference between the two groups. 5. There was no significant correlation between the cervical curvature and the area of the posterior arch of the atlas. 6. The method using curved ruler for measuring cervical curvature could be accepted as a reliable method.

  • PDF

The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area (영상의학과 이동검사 영역의 공간선량 분포에 대한 측정 및 분석)

  • Kim, Sung-Kyu;Son, Sang-Hyuk
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.5-13
    • /
    • 2009
  • There are several reasons to take X-ray in case of inpatients. Some of them who cannot ambulate or have any risk if move are taken portable X-ray at their wards. Usually, in this case, many other people-patients unneeded X-ray test, family, hospital workers etc-are indirectly exposed to X-ray by scatter ray. For that reason I try to be aware of free space scatter dose accurately and make the point at issue of portable X-ray better in this study. kVp dose meter is used for efficiency management of portable X-ray equipment. Mobile X-ray equipment, ionization chamber, electrometer, solid water phantom are used for measuring of free space scatter dose. First of all the same surroundings condition is made as taken real portable X-ray, inquired amount of X-ray both chest AP and abdomen AP most frequently examined and measured scatter ray distribution of two tests individually changing distance. In the result of measuring horizontal distribution with condition of chest AP it is found that the mAs is decreased as law of distance reverse square but no showed mAs change according to direction. Vertical distribution showed the mAs slightly higher than horizontal distribution but it isnt found out statistical characteristic. In abdomen AP, compare with chest AP, free space scatter dose is as higher as five-hundred times and horizontal, vertical distribution are quite similar to chest AP in result. In portable X-ray test, in order to reduce the secondary exposure by free space scatter dose first, cut down unnecessary portable order the second, set up the specific area at individual ward for the test the third, when moving to a ward for the X-ray test prepare a portable shielding screen. The last, expose about 2m apart from patients if unable to do above three ways.

  • PDF

Design of High-precision CTE measurement System for the Structural Materials in Space Applications (우주용 구조 재료의 초정밀 열팽창계수 측정시스템 설계)

  • Kim, Hong-Il;Han, Jae-Hung;Yang, Ho-Soon;Cho, Chang-Rae;Cho, Hyok-Jin;Kim, Hong-Bae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.9
    • /
    • pp.916-922
    • /
    • 2008
  • Structures being used in space environment, should be designed to have minimum CTE(coefficient of thermal expansion) for the dimensional stability. Accurate CTE data of the materials are required to design the space structures consisting of various materials. There are uncertainties in the characteristics of materials even though the same manufacturing processes are applied. Therefore, it is needed to measure the thermal deformation of not only the material specimen but also substructures in simulated space environment, such as high vacuum condition. In this research, therefore, precise CTE measurement system using displacement measuring interferometer and vacuum chamber has been designed with uncertainty analysis of the measurements. This system can be used to measure the CTE of the specimen or thermal expansion of the substructure with varying size up to 50cm in length. To measure the low CTE material, overall uncertainty of this system is expected under 0.01ppm/K.

A Study on the Space Composition of Dong-gok Jaesa (동곡재사(東谷齋舍)의 공간구성에 관한 연구(硏究))

  • Yoo, In-Ho;Ha, Heon-Jeong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.12 no.3
    • /
    • pp.121-128
    • /
    • 2009
  • This study is for getting sacrificial service, discussing process of sacrificial rituals and understanding the composition of space in Dong-gok Jaesa. For these things, we're arranged for exact blueprint through actual survey and analyzed the architectural features. Dong-gok Jaesa has features which show centripetal space organization with strong closing sparsely. This is intended for sincerity during ritual which is processed without obstruction. This is a mixed form which is unified both straight dwelling and Jung Dang Hyeop Sil type. And this is for all functions which is necessary for Jaesa architecture in only one building. And this is used with organizing technique for space utility with connection of compartments and various enlargement and partition. Through these things, even though it is not a big Jaesa, it shows that this is Korea traditional composition of space technique according to several purposes.

  • PDF