• 제목/요약/키워드: Measuring Length

검색결과 1,167건 처리시간 0.031초

철분 코아(core) 자동 선별기 (Automating the visual classification of metal cores)

  • 박인규;송경호;하태중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.302-307
    • /
    • 1990
  • An automatic visual classification system is introduced which provides for measuring the length and diameter of coilform cores and dividing them into 5 different classes in terms of how far their length be from the desired length. This task is fully automated by controlling two STEP motors and by using image processing techniques. The classification procedure is broken into three logical parts. Fist, cores in the form of randomly stacked bundle are lined up one by one so as to be well captured by a cameras. The second part involves capturing core image. Then, it enters the measuring process. Finally, this machine would retain all tire information relating to the length. According to the final result, cores are sent to the corresponding bin. This considerably simplifies the selecting task and facilitates a greatly improved reliability in precision. The average classifying capability about 2 pieces per second.

  • PDF

타이트 스커트 실루엣 및 길이에 따른 동작적합성과 트임길이에 관한 연구 (A Study on Moving Fitness and Slit Length in Relation to Length & Silhouette of Tight Skirt)

  • 김희영;최혜선
    • 한국의류학회지
    • /
    • 제17권4호
    • /
    • pp.539-549
    • /
    • 1993
  • The purpose of this study was to find out the moving fitness and slit length of tight skirt in relation to its length & silhouette. Five kinds of length, micro mini, mini, natural line, medi and maxi, and two kinds of siihuette, slim & straight-a total of ten tight skirts-were investigated. Ten college students were chosen for this experiment. The moving fitness was tested by measuring the step length, step width and step angle in the case of walking on the flat and going up the stairway & bus stair. The slit length was tested by measuring the back slit length needed in the case of going up stairway & bus stair. Data were analyzed with use of SAS pakage. The statistics were based on average, standard diviation, two-way ANOVA, Pearson's correlation and multiple regression analysis. The main results were as follows. 1. There was significant difference in the moving fitness according to length & silhouette of tight skirt. The moving fitness of slim type was lower than that of straight type and the longer the skirt length was, the lower the moving fitness was. The significance appeared particularly in the case of going up the bus stair. 2. There was significant difference in the skirt length obove slit accorting to length & silhouette of tight skirt. The skirt length obove slit of slim type was shorter than that of straight type. The longer skirt length was, the longer it was from micro mini to natural line, that of medi skirt was shorter or a little longer than that of natural line skirt and there was little change from medi skirt to maxi skirt.

  • PDF

게이지 블록 간섭계의 선진화 및 완전 자동화 (Advancing the Gauge Block Interferometer and Automating the Gauge Block Calibration)

  • 강주식;김재완;서호성;이원규;김종안
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.547-550
    • /
    • 2005
  • Gauge blocks are the most widely used material measure in length field in industry. The gauge block interferometer, which is the gauge block measuring system, comprises Twyman-Green type interferometer optics and light sources having precisely known wavelengths. This paper describes the work done for advancing the measurement system and automating the measurement process. The advancing of the system was done mainly by exchanging the spectral lamp with the frequency stabilized lasers, and the automation of measurement was achieved by modifying the hardware and developing the automatic measuring software. As the results of this work, the contrast of interferometric fringes of gauge blocks longer than 100 mm s enhanced about 20 times, and the measurement time has reduced down to 50% by automation.

  • PDF

레이저간섭계의 위치결정정밀도 측정오차 개선 (Improvement of the Laser Interferometer Error in the Positioning Accuracy Measurement)

  • 황주호;박천홍;이찬홍;김승우
    • 한국정밀공학회지
    • /
    • 제21권9호
    • /
    • pp.167-173
    • /
    • 2004
  • The heterodyne He-Ne laser interferometer is the most widely used sensing unit to measure the position error. It measures the positioning error from the displacement of a moving reflector in terms of the wave length. But, the wave length is affected by the variation of atmospheric temperature. Temperature variation of 1$^\circ C$ results in the measuring error of 1ppm. In this paper, for measuring more accurately the position error of the ultra precision stage, the refractive index compensation method is introduced. The wave length of the laser interferometer is compensated using the simultaneously measured room temperature variations in the method. In order to investigate the limit of compensation, the stationary test against two fixed reflectors mounted on the zerodur$\circledR$ plate is performed firstly. From the experiment, it is confirmed that the measuring error of the laser interferometer can be improved from 0.34${\mu}m$ to 0.11${\mu}m$ by the application of the method. Secondly, for the verification of the compensating effect, it is applied to estimate the positioning accuracy of an ultra precision aerostatic stage. Two times of the refractive index compensation are performed to acquire the positioning error of the stage from the initially measured data, that is, to the initially measured positioning error and to the measured positioning error profile after the NC compensation. Although the positioning error of an aerostatic stage cannot be clarified perfectly, it is known that by the compensation method, the measuring error by the laser interferometer can be improved to within 0.1${\mu}m$.

3 차원 좌표 측정기의 측정 성능에 대한 실험적 연구 (An Experimental Study on the Measurement Performance of Coordinate Measuring Machine)

  • 이승표;강형주;하성규
    • 한국정밀공학회지
    • /
    • 제26권3호
    • /
    • pp.47-54
    • /
    • 2009
  • In the manufacturing industry, there has been a significant increase in the use of coordinate measuring machines(CMM). In this paper, the sources of CMM measurement performance are discussed. The effects of workpiece position, length and orientation are analyzed by using the design of experiments. Both a fractional factorial design and a factorial design are employed to conduct the experimental study. The analysis of variance is performed to determine the significance of factors in the experiment and regression analysis is applied to make the measurement approximate model. The results show that position along the Z axis, length and orientation affect the CMM measurement performance.

선회로 인한 오리피스 유량계의 계량오차 예측을 위한 삼차원 유동해석 (Three-Dimensional Flow Analysis for Estimation of Measuring Error oi Orifice Flowmeter due to Swirling Flow)

  • 김홍민;김광용;허재영;하영철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.79-82
    • /
    • 2002
  • Three-dimensional pipe flows with elbows and tees for few different pipe fittings are calculated to estimate the effect of swirling flow on measuring accuracy of orifice flow meter. It is evaluated how the pressure difference across the orifice is dependent on the length of upstream straight pipe in a branch and how swirl intensity, swirl angel and axial velocity distribution affect the measuring error of orifice flowmeter. From the results, it is found that, regardless of flow rate specified in this calculation, the effect of the straight pipe length can be neglected for the lengths larger than thirty diameters although there still remain significant swirl at the orifice

  • PDF

이종 접합부재의 두께 변화에 따른 초음파 산란 보정에 의한 계면균열 길이의 측정 (Measurement of Interfacial Crack Length by Ultrasonic Scattering Compensation Depending on Thickness Variations of Bonded Dissimilar Components)

  • 정남용
    • 한국자동차공학회논문집
    • /
    • 제14권2호
    • /
    • pp.67-75
    • /
    • 2006
  • In this paper, the compensation of ultrasonic scattering on interface crack depending on thickness variations of A1/Epoxy bonded dissimilar components was applied to improve measuring accuracy by using ultrasonic attenuation coefficient. The optimum conditions of theoretical value and experimental measuring accuracy by the ultrasonic method in A1/Epoxy bonded dissimilar components have been investigated. From the experimental results, the measurement method of interfacial crack lengths by using ultrasonic attenuation coefficient was proposed and discussed. After the ultrasonic scattering compensation depending on thickness variations of bonded dissimilar components was carried out, the measuring accuracy of interfacial crack length was improved by 5%.

한국인 성인에 대한 기성 tray의 적합도에 관한 연구 (A STUDY ON THE FITNESS OF STOCK TRAY IN KOREAN ADULTS)

  • 송대성;진태호;동진근
    • 대한치과보철학회지
    • /
    • 제27권2호
    • /
    • pp.131-141
    • /
    • 1989
  • This study was designed to investigate the fitness of stock tray in Korean adults. 107 dental students (male: 87, female: 20) who have normal occlusion and symmetric facial fom were selected. The upper and lower stock tray (Osungtray, Osung Co., Korea) fit with dental arch were selected for taking irreversible hydrocolloid impression. The author measured the thickness of impression material about two items, that is, width and length on the flange of stock tray. Several measuring points on the dental arches and palatal area were checked with Goldman Fox prove (Hu-Friedy, U.S.A.). The obtained results were as follows: 1. The width of impression material on buccal flange of upper and lower trays were narrower than any other measuring point, but the thickness of impression material on the palatal area of upper stock tray was the widest of all measuring points. 2. The length on buccal flange of lower stock tray was shorter, but the length on tray flange of lower stock tray at lingual frenum area was longer. 3. On upper dental arch, the upper extra-large tray was used in 53% of subjects, but upper small tray was not used. 4. On lower dental arch, the large tray was used in 55% of subjects. 5. There was not adequate tray on upper dental arch in 4 subjects.

  • PDF

길이재기 단원의 여정: 수학 교과서 개발과정 (A Journey of the Measuring Length Unit: A Description of Mathematics Textbook Development)

  • 이경화;강완
    • 대한수학교육학회지:수학교육학연구
    • /
    • 제18권2호
    • /
    • pp.157-177
    • /
    • 2008
  • 이 연구는 2006년 수정 고시된 수학 교육과정에 따라 초등학교 수학 교과서를 개발하는 과정, 그 과정에서 제기된 주된 논점과 그 해결 과정을 2학년 길이재기 단원에 한하여 제시하는 것에 목표를 둔다. 수학 교과서를 개발하기 위해서는 달라진 교육과정을 반영하고, 관련 이론을 점검하여 연결하며, 교육 현장의 특수성을 반영하고, 학습자의 특성을 고려하는 등 매우 복잡한 과정을 겪어야 한다. 그러므로 어떤 단원, 어떤 과제 하나도 단번에 만들어지는 것이 아니라 길고 짧은 여정을 가진다고 할 수 있다. 교과서는 수업의 방향과 질을 결정하는 매우 중요한 요소인 만큼 개발 과정에서의 논의를 지속적으로 누적하고 개선점을 찾아가는 노력이 필요하다. 이 연구는 실험본을 개발하는 과정까지 다루고 있으며, 실험본의 적용 결과 분석과 개선은 후속 연구에서 시도할 예정이다.

  • PDF

접지시스템의 설계를 위한 대지저항률의 합리적인 측정방법 고찰 (Examinations on the Reasonable Measuring Methods of the Soil Resistivity for Design of Grounding System)

  • 이복희;김기복;이승훈;최종혁
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.35-41
    • /
    • 2011
  • In order to design effectively the grounding system, it is very important to determine the optimum soil resistivity at the desired location of the connection to earth. This paper deals with the reasonable methods of measuring the soil resistivity where grounding electrodes are buried. The soil resistivity at three test sites with different resistivity of soil were measured as functions of the spacing between the test probes in the Wenner's four-point method and the length of test ground rod in the three-point method. In the case of the three-point method, the length of test ground rod of 2-10[m] in length was appropriate in two-layered soil structure. In the length range of 2-10[m], the results measured by the three-point method using the test ground rod with the length corresponding to the spacing between the test probes of the Wenner's four-point method are in good agreement with the data obtained from the Wenner's four-point method.