• 제목/요약/키워드: Measuring Interval

Search Result 317, Processing Time 0.025 seconds

Development of Density Measurement Technique Based on Two Point Detectors and Measurement Reliability According to Different Sensing Gaps (두 지점의 지점검지기를 이용한 밀도측정방안 개발 및 측정간격에 따른 신뢰성 분석)

  • Lee, Cheong-Won;Kim, Min-Seong;Park, Jae-Yeong;Lee, Eun-Gyu
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.3
    • /
    • pp.157-167
    • /
    • 2010
  • Density is the most important congestion indicator among the three fundamental flow variables, flow, speed and density. Measuring density in the field has two different ways, direct and indirect. Taking photos with wide views is one of direct ways, which is not widely used because of its cost and lacking of proper positions. Another direct density measuring method using two point detectors has been introduced with the concept of instantaneous density, average density and measurement interval. The relationship between accuracy and measurement interval has been investigated using the SIMULATION data produced by Paramics Application Programming Interface function. We analyze the affect of segment density accuracy by sensing gap each road condition such as sensing segment length, lane and LOS after gathering data by Paramics Application Programming Interface.

Comparison of Magnetocardiogram Parameters Between a Ischemic Heart Disease Group and Control Group (정상군 및 허혈성 심질환 환자군에서의 심자도 파라미터 비교)

  • Park, Jong-Duk;Huh, Young;Jin, Seung-oh;Jeon, Sung-chae
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.11
    • /
    • pp.680-688
    • /
    • 2005
  • The electrical current generated by heart creates not only electric potential but also a magnetic field. We have observed electrophysiological phenomena of the heart by measuring components of magnetocardiogram(MCG) using 61 channel superconducting quantum interference device(SQUD) system. We have analyzed the possibility and characteristics of MCG parameters for diagnosis of ischemic heart disease. A technique for automatic analysis of MCG signals in time domain was developed. The methods for detecting the position, the interval, the amplitude ratio, and the direction of single current dipole were examined in the MCG wave. The position and interval parameters were obtained by calculating the gradients of a envelope curve which could be formed by the difference between the maximum and minimum envelope of multi-channel MCG signals. We show some differences of the frequency contour map between the normal MCG and the abnormal (ischemic heart disease) MCG. The direction of single current dipole can be defined by rotating the magnetic field according to Biot-Savart's law at each point of MCG signals. In this study, we have examined the direction of single current dipole from searching for the centroids of positive and negative magnetic fields. The amplitude ratio parameters for measuring 57 deviation consisted of A$_{T}$/A$_{R}$ and other ratios. and We developed a new analysis method, which is based on the frequency contour map of electromagnetic field. Using theses parameters, we founded significant differences between normal subjects and ischemic patients in some parameters.

The effect of acupuncture at BL-23 and BL-28 on function of the urinary bladder in dogs (개에서 신수(BL-23) 및 방광수(BL-28)에 대한 침술이 방광기능에 미치는 영향)

  • Park, Hong-Sik;Yun, Young-Min;Lee, Kyoung-Kap
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.4
    • /
    • pp.469-473
    • /
    • 2007
  • This study was performed to investigate the effects of urinary acupoint (BL-23, BL-28) by acupuncture (AP) and electroacupuncture (EA) on urinary bladder in dogs. Four healthy male dogs aged within the range of 6~8 months were used in this experiment. For Electrodes implantation on the bladder, dogs were to undergo surgical operation. The purpose of investigating the effect on urinary bladder was to evaluate electromyogram (EMG) changes according to AP or EA at Shen Shu (BL-23), Pang Guang Shu (BL-28) and non-acupoint. AP and EA (2~4 V, 10 Hz) were applied for 20 min to each point. EMG was evaluated when acupuncture began stimulation and as soon as the stimulation by electroacupuncture was gone. By the experiment of investigating the effect of urinary time it was estimated to measure time up to urination from stimulation on effective acupoint, after saline was filled with 70% of whole volumes on urinary bladder. The wave of EMG on resting stage showed simple and regular, whereas that of EMG on urination showed irregularly strong peaks before urination. Acupuncture of BL-28 had an influence on changes of EMG which had irregular peaks on urination. But the changes of EMG after acupuncture of BL-28 and control were regular like resting stage. The changes of EMG after EA at BL-23 and BL-28 showed irregularly a variety of wave forms. The interval through urination from stimulation at BL-28 and control become short as measuring time by EA (p<0.01). According to the results, AP at BL-28 was effective to urinary bladder. EA at BL-23 and BL-28 was effective to urinary bladder. Especially, the interval on stimulating at BL-28 by EA was the shortest in measuring time to urination from stimulation.

Parameters of the Magnetic Field Waveform Radiated from Cloud Lightning Discharges (운방전에 의해서 방사된 자장 파형의 파라미터)

  • 이복희;안창환;장석훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.6
    • /
    • pp.917-926
    • /
    • 1999
  • In this paper, the recording device for measuring the magnetic field waveforms associated with the cloud lightning discharges was made by the loop-type magnetic field sensor, and the measuring system of a distance between lightning stroke point and observatory site was proposed. The parameters including the time interval of superimposed pulses, zero-to-zero crossing time and the percentage depth of the dip for the positive and the negative magnetic field waveforms were statistically analyzed as a function of the distance between the lightning discharge point and the observatory site. The results could be summarized as follows; Several superimposed pulses were observed at the initial front part of the magnetic field waveform produced by cloud lightning discharges, and the mean time interval between superimposed pulses was about $4\mu\textrm{s}$. Also, the bipolar characteristic appeared significantly and the percentage depth of the dip was about 57~65%. It was known that the zero-to-zero crossing time of the electromagnetic fields is gradually decreased as a distance between lightning discharge point and observatory site is increased.

  • PDF

A Feasibility Study on Multiple DME Positioning Considering Time-Misaligned Range Measurements (시각 비동기 오차를 고려한 다중 DME 측위 적용 방안 연구)

  • Choi, Kwang-Ho;Lim, Joon-Hoo;Yoo, Won-Jae;So, Hyoungmin;Lee, Hyung-Keun
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.6
    • /
    • pp.534-543
    • /
    • 2015
  • This paper introduces the time-misalignment error between multiple range measurements acquired by an onboard distance measuring equipment (DME) interrogator and proposes an efficient position determination method that can mitigate the negative effects of the time-misalignment error. The introduced time-misalignment error does not occur in conventional utilization of DME combined with VHF omnidirectional range (VOR). The proposed position determination method projects all the DME range measurements acquired irregularly during an interval to the same time instance where the aircraft position is determined. By the simulation utilizing a representative aircraft trajectory, it is shown that it is possible to estimate the horizontal position accurately without any changes of ground DME facilities.

Water Saving Irrigation Manual of Red Pepper for the Southern Region of Korea (우리나라 남부권역 노지재배 고추의 물절약형 관개 기준 설정 연구)

  • Eom, Ki-Cheol;Yoo, Sung-Yung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.2
    • /
    • pp.306-311
    • /
    • 2012
  • Water management is the most important and difficult problems in red pepper cultivation.The water requirement of red pepper is different according to the area as well as climate condition, growth stage and soil texture. Also, the measurement of evapo-transpiration (PET) and crop coefficient (Kc) is very difficult especially in field cultivation. The average PET during 30 years of southern region of korea for the red pepper cultivation was a $2.75mm\;day^{-1}$. The water saving irrigation manual with irrigation interval and amount of irrigation according to growing season and soil texture, are developed based on the lysimeter experiments carried out by the RDA for 11 years about potential evapo-transpiration, crop coefficient for the 17 southern region of korea. The water saving irrigation manual can be used with easy to the farmer without soil sampling and any kinds of sensors measuring soil water status.

Proposed Assessment for Quality of Experience of Live IPTV in Home Environments

  • Jeong, Jongpil;Choi, Jae-Young
    • International journal of advanced smart convergence
    • /
    • v.4 no.1
    • /
    • pp.18-30
    • /
    • 2015
  • As the speed of networks that subscribers can use has greatly increased, demand for high-quality broadcast content, such as from Internet Protocol Television (IPTV) and Video on Demand (VoD), is likewise increasing. Therefore, while broadcasters are increasing content and channels, they are striving to improve consumer quality of experience (QoE) to differentiate themselves from competitors, including by producing higher physical-quality content. Recently, subjective measurement methods have been internationally standardized as the most reliable approach for measuring and evaluating IPTV QoE. However, a majority of these methods are performed in experimental environments and are based on the extremely brief viewing period of approximately ten seconds using original reference videos. It is actually difficult to apply standard evaluation methods based on a ten-second viewing interval to assess real broadcast watching of IPTV or other services that involve a longer time (i.e., more than thirty minutes). In this paper, we therefore propose a method that accommodates actual viewing environments. Using the mean opinion score, we experimentally analyze the effects of evaluation interval changes under actual conditions in which IPTV service is provided. In addition, we propose improvements by applying the results into actual live broadcast IPTV service and by analyzing consumer service QoE.

A Study of the Characteristics Times of Polymer Solutions Using the PIV System (PIV 시스템을 이용한 폴리머 용액의 특성시간에 관한 실험적 연구)

  • Lee, Jae-Su;Jeon, Chan-Yeal;Park, Jong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1552-1557
    • /
    • 2004
  • Characteristics diffusion time of viscoelastic fluids are determined experimental results of terminal velocity by using the falling ball viscometer. The characteristics diffusion time of viscoelastic fluids are determined with help of the sphere device which is installed to return the dropped sphere from the bottom of the test cylinder without disturbing the working fluids. Terminal velocity of th sphere the reason why experimental of characteristics diffusion time that it is have an effect on the time interval of the measuring. Viscous of the fluid the temperature changed in order to have an effect on temperature and terminal velocity of the ball it becomes larger the possibility of knowing. A result of visualization for flow phenomena of around the sphere uses the PIV and the density of the polymer solution which it appears 2000wppm is to a case which is the right and left becomes symmetry to be it will be able to confirm and according to the time interval, to observed velocity vector of same at first drop the sphere.

  • PDF

Estimation of baroreflex sensitivity using pulse arrival time rather than systolic blood pressure measurement

  • Lee, Jong-Shill;Chee, Young-Joon
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.1
    • /
    • pp.14-19
    • /
    • 2010
  • Baroreflex sensitivity (BRS) is a parameter of the cardiovascular system that is reflected in changes in pulse interval (PD and systolic blood pressure (SBP). BRS contains information about how the autonomic nervous system regulates hemodynamic homeostasis. Normally the beat-to-beat SBP measurement and the pulse interval measured from the electrocardiogram (ECG) are required to estimate the BRS. We investigated the possibility of measuring BRS in the absence of a beat-to-beat SBP measurement device. Pulse arrival time (PAT), defined as the time between the R-peak of the ECG and a single characteristic point on the pulse wave recorded from any arterial location was measured by photoplethysmography. By comparing the BRS obtained from conventional measurements with our method during controlled breathing, we confirmed again that PAT and SBP are closely correlated, with a correlation coefficient of -0.82 to -0.95. The coherence between SBP and PI at a respiration frequency of 0.07-0.12 Hz was similar to the coherence between PAT and PI. Although the ranges and units of measurement are different (ms/mmHg vs. ms/ms) for BRS measured conventionally and by our method, the correlation is very strong. Following further investigation under various conditions, BRS can be reliably estimated without the inconvenient and expensive beat-to-beat SBP measurement.

An Ultrasonic Application with High Frequency for the Efficiency Elevation of the Hydrogen Fuel Production (On the Pole Interval and the Temperature) (수소연료 생산의 효율향상을 위한 고주파수 초음파 응용 (극간격과 온도 중심으로))

  • Song, Min-Geun;Son, Seung-Woo;Ju, Eun-Sun
    • Journal of Hydrogen and New Energy
    • /
    • v.13 no.2
    • /
    • pp.127-134
    • /
    • 2002
  • A Study on the application of ultrasonic with high frequency is carried out as a plan to rise the efficiency of the hydrogen fuel production in an electrolysis of water. KOH is selected as an electrolyte and concentrations are 0 %, 10 %, 20 %, and 30%. The solvent is city water. A measurable device of buoyancy by an electronic balance and a measurable device of voltage with a sensor of pressure are planned newly as a measuring device to measure the quantity of hydrogen production. An ultrasonic transducer with high frequency of 2 MHz is selected to give them the ultrasonic forcing. In results, it is clarified that ultrasonic influences the decrease of overpotential in the electrolytic solution. And basic data according to the pole interval and the temperature are obtained.