• Title/Summary/Keyword: Measuring Interval

Search Result 317, Processing Time 0.028 seconds

A Quantitative Method of Measuring Color Expression Power in Eye shadow

  • Kim, Sangjune;Lee, Jaeuk;Kim, Hyungjin;Kim, Jinjun;Kang, Seh-hun
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.26 no.1
    • /
    • pp.233-238
    • /
    • 2000
  • We developed a quantitative method for evaluating CEP(color expression power) in eye shadow. This method enables the cosmetic industry to measure CEP on an interval scales, so it is more accurate and reproducible than previous panel tests. Oil, colorants, Pigments and pearls are major factors affecting CEP in eye shadow formulas. We studied the oil effect on CEP using our unique method so CEP could be improved. We believe this method can be applied to other color cosmetics as well. In conclusion, we expected this method to be useful to formulator who want to improve the color expression power in color cosmetics. Additionally, we hope it will contribute toward developing the experiential know-how about color to scientific knowledge.

  • PDF

Long-term measurement of physiological cardiovascular parameters using telemetry system in dosgs.

  • Kim, Eun-Joo;Seo, Joung-Wook;Choi, Gyu-Kap;Park, Eun-Kyung;Kim, Ki-Suk;Shin, Won-Ho;Han, Sang-Seop
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.87.1-87.1
    • /
    • 2003
  • With the issuance of the ICH “Guidance for industry S7A Safety Pharmacology Studies For Human Pharmaceuticals” in July 2001 came the preference for the use of unanesthetized animals when evaluation the safety profile of new pharmaceutical agents. Telemetry provides a means of obtaining measurements of physiological functions in conscious animals without the problems associated with classical cardiovascular measuring methods. The Korea Institute of Toxicology (KIT) established the telemetric measurement of cardiovascular parameters, such as Blood pressure, Heart rate, ECG (PR, RR, QRS, QT and QTcB interval) under GLP conditions. (omitted)

  • PDF

An Evaluation of Error Performance Estimation Schemes for DS1 Transmission Systems Carrying Live Traffic

  • Eu, J.H.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.14 no.1
    • /
    • pp.1-15
    • /
    • 1988
  • DS1 transmission systems use framing bit errors, bipolar violations and code-detected errors to estimate the bit error rate when determining errored and severely errored seconds. Using the coefficient of variation under the memoryless binary symmetric channel assumption, a basic framework to evaluate these estimation schemes is proposed to provide a practical guideline in determining errored and severely errored seconds which are fundamental in monitoring the real-ime error performance of DS1 transmission systems carrying live traffic. To evaluate the performance of the cyclic redundancy check code (CRC), a computer simulation model is used. Several drawbacks of the superframe format in association with real time error performance monitoring are discussed. A few recommendations are suggested in measuring errored and severely errored seconds, and determining service limit alarms through the use of the superframe format. Furthermore, we propose a new robust scheme for determining service limit alarms which take into consideration the limitations of some estimation schemes for the time interval of one second.

  • PDF

Development and Validation of a Multidimensional Measure of Positive Body Image

  • Lee, Minsun;Lee, Hyun-Hwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.4
    • /
    • pp.704-722
    • /
    • 2022
  • Current studies validate the Body Positive Scale (BP Scale) as a self-assessment instrument that captures four dimensions of the positive body image construct. We developed and evaluated a 17-item BP Scale using two focus group interviews and four independent samples (n = 1,379) of Korean women who completed online survey questionnaires. We generated an initial pool of items via literature review, content validation with experts, and focus group interviews, subsequently refining the items through exploratory analysis (Study 1). We confirmed the BP Scale's underlying dimensions with young Korean female samples (Study 2, Study 4) and with a community sample (Study 3). We also examined the construct validity, internal consistency, and test-retest reliability over a six-week interval. Overall, the results supported that the four-factor BP Scale demonstrates adequate validity and reliability in measuring positive body image among Korean women. The BP Scale provides a method for researchers and practitioners to understand and assess individuals' positive body image in a multifaceted manner.

Nondestructive Evaluation of Remanent Life of Turbine Rotor Steel by Measuring Reversible Magnetic Permeability (가역투자율 측정에 의한 터빈로터강의 비파괴적 잔여수명 평가)

  • Ryu, Kwon-Sang;Nahm, Seung-Hoon;Kim, Yong-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.315-321
    • /
    • 2003
  • The integrity of the turbine rotors can be assessed by measuring the material properties at service temperature. In order to evaluate the remanent life of turbine rotor steel nondestructively, a measurement system of reversible magnetic permeability using an alternating perturbing magnetic field was constructed. We present a new non-destructive method to evaluate the remanent life of 1Cr-1Mo-0.25V steel using the value of reversible magnetic permeability. This method is based on the existence of reversible magnetic permeability in the differential magnetization around the coercive field strength. We measured the first harmonics voltage induced in a coil using a lock-in amplifier tuned to an exciting frequency. The Results of reversible magnetic Permeability and Wickers hardness on the aged samples show that the peak interval of reversible magnetic permeability (PIRMP) and Vickers hardness decreases as aging time increases. A softening curve is obtained from the correlation between Vickers hardness and the PIRMP. This curve can be used as a non-destructive method to evaluate the remanent life of turbine rotor steel.

Water Saving Irrigation Manual of House Red Pepper for the Northern Region of Korea (우리나라 북부권역 시설재배 고추의 물절약형 관개 기준 설정 연구)

  • Eom, Ki-Cheol;Park, So-Hyun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.2
    • /
    • pp.312-316
    • /
    • 2012
  • Very important factor for crop cultivation are water, nutrient and temperature. However, the essential factor for crop cultivation is water management. Water management is the most important and difficult problems in crop cultivation. The water saving irrigation manual can be used with easy to the farmer and who want automatic irrigation without soil sampling and any kinds of sensors measuring soil water status. The water requirement of red pepper cultivated in plastic film house is different according to soil texture, area as well as climate condition and growth stage. And, the measurement of potential evapo-transpiration (PET) and crop coefficient (Kc) to decide optimum irrigation schedule is very difficult. Results : The average PET during 30 years of northern region of korea for the red pepper cultivation was a $2.31mm\;day^{-1}$. The water saving irrigation manual as water saving is possible, those irrigation interval and amount of irrigation according to growing season and soil texture, are developed using the lysimeter experiments carried out by the RDA for 11 years about potential evapo-transpiration, Kc for the northern region of korea.

The Effect of Base Projecting Walls on the Bearing Capacity and Settlement of Shallow Foundations on Soft Ground (저면돌출벽을 이용한 연약지반상 얕은기초의 지내력 증대 효과)

  • Lim, Jongseok;Park, Seunghoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1523-1528
    • /
    • 2013
  • It is necessary to develop the simple and efficient technique that ease entry of man and equipment and take the role of foundations of temporary or small structures on the soft ground. This study intends to verify the effects on the increase of bearing capacity of base projecting walls under shallow foundations and to investigate the variance of the bearing capacity of the foundations according to the interval and length of the walls. For this, model soft ground in the chamber equipped with loading apparatus is made and the loading tests on the model foundations with base projecting walls of various intervals and lengths using the apparatus are performed with measuring the loads and settlements. The results show that the base projecting walls under shallow foundations on soft ground are effective on the increase of bearing capacity and the more the number and length of the walls the larger the effects. And, when the ratio of interval to length of the walls is 1, i.e. the shape forming the base of the foundation and the walls is square, the bearing capacity is increased by 25% and the effect is optimum.

Measurement of Critical Heat Flux Using the Transient Inverse Heat Conduction Method in Spray cooling (비정상 열전도 역산법에 의한 분무냉각 임계열유속(CHF)의 측정에 관한 연구)

  • Kim, Yeung Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.10
    • /
    • pp.653-658
    • /
    • 2016
  • A study on the measurement of critical heat flux using the transient inverse heat conduction method in spray cooling was performed. The inverse heat conduction method estimates the surface heat flux or temperature using a measured interior temperature history. The effects of the measuring time interval and location of temperature measurement on the measurement of critical heat flux were primarily investigated. The following results were obtained. The estimated critical heat flux decreased as the time interval of temperature measurement increased. Meanwhile, the effect of measurement location on critical heat flux was not significant. It was also found, from the experimental results, that the critical superheat increased as the measurement location of thermocouple neared the heat transfer surface.

Basic Study Measuring Cow Body Parameters and Adjusting Her Postures for an Robotic Milking System (로봇 착유기를 위한 젖소 체위측정 및 자세조정의 기초 연구)

  • Kwon, D.J.;Kim, W.;Lee, D.W.
    • Journal of Animal Environmental Science
    • /
    • v.8 no.3
    • /
    • pp.171-176
    • /
    • 2002
  • Physical parameters of milk cow were measured to design and build RMS(Robotic Milking System) with a tape-measurer and body parameter measurer. The parameters are very important variables to design an RMS. For the working zone space of an RMS manipulator and the movement blunting of milk cow, an interval frame was installed on the stall bottom, and then cow's behavioral reactions were tested. The results from this study is summarized as follow. 1. On the general physical condition measurement, the maximum, minimum and average body length of cow which is related to the space that the manipulator could work into the RMS were 175cm, 144cm, and 163cm respectively. It appeared that the average distance between bottom and chest was 60cm. 2. The average length between fore teats, fore and hind teats and hind teats were 178mm, 150mm and 95mm respectively. It appeared that the average length between bottom and teat attachments was 544mm, and the average length between fore teats and tail-end was 331mm. 3. Although a cow kept a some extent length between hind legs for milking, it looked a stable pose. However, the cow kept a some extent distance between front legs for milking, it looked a unstable pose. Based on results of this test, an interval frame of stall bottom should be installed around the position which was located at its hind legs.

  • PDF

Validation of Non-invasive Method for Electrocardiogram Recording in Mouse using Lead II

  • Kim, Myung Jun;Lim, Ji Eun;Oh, Bermseok
    • Biomedical Science Letters
    • /
    • v.21 no.3
    • /
    • pp.135-143
    • /
    • 2015
  • Electrocardiogram measures the electric impulses generated by the heart during its cycle. Recently genome-wide association studies on electrocardiogram traits revealed many relevant genetic loci. Therefore, these findings need to be validated and investigated to determine the underlying mechanisms using mouse models. Invasive radiotelemetry has been widely used to record the electrocardiogram in mice because it has several advantages over non-invasive measurements. However, radiotelemetry is expensive and requires complicated surgery. On the other hand, a non-invasive method using 3 electrodes (one for earth) for lead II is easy to establish and allows for rapid measurement. In this study, eleven mice were measured with this non-invasive method and no statistical difference among them was found in any ECG measurements. In addition, repeat measurement in the same mouse was performed in 9 sets of experiment and the results indicated that non-invasive method was reliable for reproducibility. Further it was shown that measurements for 1, 5, 10, and 15 minutes were not different so that a short recording such as 5 minutes was enough to estimate the ECG values including heart rate. Further this method was validated by measuring the ECG of Balb/c and FVB that were previously shown to differ in ECG values by radiotelemetry. Significant differences were found in heart rate, PR interval and corrected QT interval between these mouse strains. This study partially proved that non-invasive method also could provide the accuracy and reproducibility. Based on these results, the non-invasive ECG recordings of lead II is recommended as a useful method for quick test in mouse model.