• 제목/요약/키워드: Measurement results

검색결과 19,448건 처리시간 0.04초

다양한 혈압상태에서 직접혈압을 기준으로 HP 자동혈압기와 국산자동혈압기의 정확도 비교 (Accuracy Comparison of Blood Pressure among the Direct Measurement Method and Two Automatic Indirect Measurement Methods in the Patients with Various Blood Pressure)

  • 송효숙;전태국;최은정;김미정
    • 기본간호학회지
    • /
    • 제8권3호
    • /
    • pp.366-378
    • /
    • 2001
  • Objective: The purpose of this study was to identify differences in measurement methods for blood pressure (Direct measurement, HP automatic indirect measurement, and SE 7000 Korean made indirect measurement), and to evaluate the clinical trial of the Korean made automatic indirect blood pressure measurement. Material & Methods: From June, 1999 to February, 2000, fifty five consecutive patients were randomized into hypertension group (n=20), normotension group (n=20), and hypotension group (n= 15). Measuring blood pressure by indirect methods (HP NIBP M 1008B and SE 7000 NIBP Korean made) was done simultaneously in the same arm with arterial line for direct blood pressure measurement (HP M1006A). The procedures were repeated ten times at intervals of 2 minutes. Statistical analysis was Performed using SPSS (version 8.0 for windows) software package. Values were expressed as means and standard deviation and means were compared using t-test. Statistical significance was considered present with a p value less than 0.05. Results: In the hypertension group and noromotension group, the disparity between HP direct measurement and indirect SE 7000 NIBP did not show any differences compared to the disparity between HP direct measurement and indirect HP NIBP. In the hypotension group, the disparity in the diastolic pressure between HP direct measurement and indirect SE 7000 NIBP was significantly different compared to the disparity between HP direct measurement and indirect HP NIBP (p<0.001), however, disparities in systolic pressure did not showed any differences. Conclusion: Direct blood pressure measurement (HP M1006A) can be replaced with indirect blood pressure measurements (HP NIBP M 1008B & SE 7000 NIBP) in normotension and hypertension patients. Korean made indirect measurement was found to be more accurate compared to HP indirect measurement in hypotension Patients, but more study is needed.

  • PDF

전류측정성분과 불량정보 검출을 고려한 전력계통에서의 상태추정에 관한 연구 (State Estimation Considering Current Measurement Component and Bad Data Detection)

  • 김준현;이종범
    • 대한전기학회논문지
    • /
    • 제35권7호
    • /
    • pp.261-271
    • /
    • 1986
  • This paper describes a method for the state estimation considering current measurement component and detection of the bad data. The state values are estimated by weighted least square method in which measurement vector included bus injection current and line current. The bad data are detected using standardized variable of normal distribution and identified using sensitivity coefficients. When the bad data were occured by the bad measurement values. The results of the application to the model power system reveal the effectiveness of the presented algorithms.

  • PDF

종합항법장치 및 GPS를 이용한 실선시운전 선박조종성능의 계측 (Measurement of ship's maneuverabilities using Integrated Navigation System and GPS)

  • 이덕수
    • 한국항해학회지
    • /
    • 제20권1호
    • /
    • pp.11-26
    • /
    • 1996
  • On this paper, the traditional methods for the measurement of ship's maneuverabilities during the sea-trial of newly built ship are summarized and new methods for the same measurement using Integrated Navigation System and GPS are introduced. After various sea-trials of training ship "HANNARA" which are equipped with modern INS and GPS system, the results are compared and analysed. The purpose of this paper is to present more accurate methods of measurement of ship's maneuverabilities during sea-trial using INS and GPS which are gradually becoming the basic navigational equipments on many newly constructed vessels.d vessels.

  • PDF

단위 동작 모형에 따른 로봇 작업시간 측정법의 개발 (Development of robot work measurement by the unit motion model)

  • 권규식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.367-370
    • /
    • 1996
  • This study deals with the motion modeling by the unit motion of robots and the work measurement through classification of robot motions and standardization. The proposed approach is to scrutinize the Predetermined Time Standards(PTS) methods for measurement of manual tasks performed by people and the basic motions for accomplishing that tasks. And then, it constructs the unit motion models as subsets composed with the basic motions. It apply together with movements distance as a time variable, too. These results are used for the work measurements of robots by the unit motion models.

  • PDF

원통 축 방향의 표면거칠기 측정을 위한 시료의 자세 보정 (Orientation Correction of a Cylinder for Surface-Profile Measurement)

  • 조남규
    • 한국생산제조학회지
    • /
    • 제5권4호
    • /
    • pp.108-120
    • /
    • 1996
  • A new technique and theory are proposed which correct orientation of a cylinder to perform a reliable measurement of the surface profile. We analyze characteristics of machined surfaces, e.g., ground, lapped and turned surfaces. Based upon the results. the optimum correction technique is derived by the statistical method. To verify the techinques, measurements are carried out by using the contact stylus profilometer on a controllable table. The measurement shows that surface information of cylinders can be acquired with high accuracy.

  • PDF

한국형 고속철도 차량의 운행조건에 따른 차내 소음 분석 (An interior noise analysis of KTX vehicles on various operating conditions)

  • 최성훈;김재철;이찬우;문경호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.138-142
    • /
    • 2003
  • The conditions for measurement of the interior noise should meet the international standards. However, due to the limitations in test conditions the possible errors in measurement equipment, reliability of the measurement results has been questioned. Hence, the test procedure for the interior noise measurement of KTX vehicles are reviewed and investigated with the reference of international standards. Furthermore, the acceptable tolerance is inspected through the analysis of the factors that influence the interior noise of the KTX vehicle.

  • PDF

다회선 초음파 유량계를 이용한 거래용 오일유량 측정 (Custody Transfer Hydrocarbon Flow Measurement with Multi-path Ultrasonic Flow Measurement)

  • 황상윤;이호준;박기환
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.149-153
    • /
    • 2003
  • As the fastest growing flowmeter technology, multi-path ultrasonic flow-meters are gaining wider range in petroleum industry for liquid hydrocarbon custody transfer measurement. This paper describes the mult-path ultrasonic flowmeter, URO-Ex1000 the requirements necessary to prove and test in Korea & China. URO-Ex1000 haver a good results with accuracy range, but a little exceed with repeatability.

  • PDF

공공기준점을 이용한 GNSS 높이측량 정밀도 분석 연구 (A Study on the Accuracy of GNSS Height Measurement Using Public Control Points)

  • 원두견;최윤수;윤하수;이원종
    • 한국지리정보학회지
    • /
    • 제24권2호
    • /
    • pp.78-90
    • /
    • 2021
  • 정밀지오이드를 구축하기 위하여 육상, 해상, 항공, 위성 중력측정 방법으로 다양화되고 측정 기술이 발전되어 고해상도 고정밀도의 중력자료 확보가 가능해졌다. 정밀지오이드의 구축은 별도의 수준측량 없이 GNSS 측량을 통해 표고를 빠르고 편리하게 결정할 수 있으며 우리나라는 2014년부터 국토지리정보원에서 GNSS를 기반으로 한 높이측량 정확도를 향상시키기 위해 합성지오이드 모델을 개발하고 있다. 본 연구에서는 공공측량의 GNSS높이측량을 검증하기 위하여 기존의 고시된 공공기준점을 선점하여 GNSS높이측량 결과와 비교 분석하였다. 실험은 연구보고서 등에서 정밀도가 낮은 지역으로 제시되거나 정밀도가 낮을 것으로 예상되는 연안, 접경, 산악지형의 공공기준점에 대하여 GNSS높이측량을 수행하고 정밀도를 분석하였다. GNSS높이측량 검증을 위해 공공기준점 GNSS높이측량 기지점으로 사용될 주변 통합기준점의 GNSS 타원체고를 점검하였다. 점검된 통합기준점을 기준으로 공공기준점의 GNSS 타원체고를 산출하고 KNGeoid18 모델을 이용하여 표고를 계산하여 직접수준측량 표고결과와 비교하였다. 분석 결과 연안, 접경, 산악 지역 공공기준점의 GNSS 높이측량 결과가 3·4급 공공수준측량 정확도에 만족하는 것으로 나타났다. 이를 통하여 사용자가 요구하는 높이 정확도에 따라 기존의 직접수준측량보다 GNSS 높이측량이 효율적으로 이용될 수 있으며, KNGeoid18도 자율주행자동차, 무인항공기 등 다양한 분야에서 활용될 수 있을 것으로 판단된다.

한의학 임상연구에서의 심박변이도 검사 활용현황과 측정조건에 대한 고찰 (Review on Current Status of Use and Measurement Condition of Heart Rate Variability in Clinical Study of Korean Medicine)

  • 김상호
    • Journal of Acupuncture Research
    • /
    • 제29권5호
    • /
    • pp.127-137
    • /
    • 2012
  • Objectives : The purpose of this study is to review on current status of use and measurement condition of heart rate variability(HRV) by reviewing clinical studies published in journal of Korean medicine registered Korea citraion index(KCI). Methods : One hundred twenty articles were found by searching the representative Korean databases. At first analysis was performed by current status of use(journal, academic field of corresponing author, purpose of study, disease of subject, HRV measurement devices, intervention methods and tests compared to HRV). At second analysis was performed by measurement condition(uncontrolled study, relaxation before measurement, measurement position, measurement place, measurement time period and restriction of smoking, alcohol, caffeine, meal). Results : The analysis showed that department of acupuncture & moxibustion, department of oriental neuropsychiatry are major part in journal & academic field. The purpose of study were classified under studies to verify therapeutic effect on normal subject(39%), to verify therapeutic effect on the patients(8%), to investigate characteristics of the patients(34%) and to be compared with other test(19%). Disease of subject & measurement devices in article were so various. Major intervention methods were acupuncture(61.4%), mind-body intervention(19.2%). Studies that measurement condition were not controlled were relax time(24%), measurement position(19%), measurement place(26%), measurement time period(91%) and restriction of smoking, alcohol, caffeine, meal(49%). Conclusions : This study showed that current status of use of HRV is widespread in Korean medicine but more controlled measurement conditon are needed to get more reliable result from clinical studies and to improve diagnosis and treatment of Korean medicine.

Effect of measurement method and cracking on chloride transport in concrete

  • Zhang, Shiping;Dong, Xiang;Jiang, Jinyang
    • Computers and Concrete
    • /
    • 제11권4호
    • /
    • pp.305-316
    • /
    • 2013
  • This paper aims to study the effect of measurement methods and cracking on chloride transport of concrete materials. Three kinds of measurement methods were carried out, including immersion test, rapid migration test and steady-state migration test. All of these measurements of chloride transport show that chloride ion diffusion coefficient decreased with the reduction of water to cement ratio. Results of the immersion test were less than that of rapid migration test and steady-state migration test. For the specimen of lower water to cement ratio, the external electrical field has little effect on chloride binding relatively. Compared with the results obtained by these different measurement methods, the lower water to cement ratio may cause smaller differences among these different methods. The external voltage can reduce chloride binding of concrete, and the higher electrical field made a strong impact on the chloride binding. Considering the effect of high voltage on the specimen, results indicate that results based on the steady-state migration test should be more reasonable. For cracked concrete, cracking can accelerate the chloride ion diffusion.