• Title/Summary/Keyword: Measurement of transverse profile

Search Result 10, Processing Time 0.022 seconds

Measurement System of the Transverse Temperature Profile of Hot Rolled Strip (열간압연공정에서의 스트립 폭방향온도 모니터링시스템 개발)

  • Lee, Sung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.197-201
    • /
    • 2001
  • Output and cost efficiency in the production of hot-rolled strip depend to a large content on the uniformity of geometric and mechanical properties over the length and width of the rolled end product. To ensure the homogeneous temperatures required for this during the rolling process a system to measure and evaluate the transverse temperature profile was developed and implemented in production. The systems used consist of temperature scanners and computers for measurement and data evaluation. The systems have been installed in Kwangyang hot strip mills, in the cases at the exit of the finishing train and at the entry of the coiler. They are used in production to determine the effect of the finishing train and the cooling zone on the technological properties of the hot rolled strip.

  • PDF

Transverse Profile Measurement of Proton Beam using the Beam Induced Fluorescence Monitor in KIRAMS-13 Cyclotron (Beam Induced Fluorescence 모니터를 이용한 KIRAMS-13 싸이클로트론의 양성자빔 횡단면 측정)

  • Nam, S.K.;Kim, K.B.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.6
    • /
    • pp.418-425
    • /
    • 2009
  • To get the stable and optimized proton beam in the KIRAMS-13 cyclotron which installed in the regional cyclotron center, it is necessary to measure the transverse profile of proton beam. Beam Induced Fluorescence monitor is one of the non-destructive methods to measure the beam profiles, and it has many advantages such as a simple structure, real-time measurement, and minimum energy loss. The objective of this research is the design and development of Beam Induced Fluorescence monitor to measure the proton beam profiles in the KIRAMS-13 cyclotron.

Measurement of POF Refractive Index Profile by using Phase-Shifting Moire Deflectometry (위상천이 모아레 간섭방법을 이용한 POF의 굴절률 분포 측정)

  • 우세윤;이현호;박승한
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.274-275
    • /
    • 2003
  • 광통신 분야의 연구 중 근거리 광통신 분야에 적용하기 위한 Plastic Optical Fiber(POF)에 관한 연구와 개발이 활발히 이루어지고 있다. POF의 광전송 특성을 결정짓는 요소 중 가장 중요한 특성이 바로 굴절률 분포이다. 이에 따라 그동안 다양한 형태의 POF 굴절률 측정 방법이 연구되어 왔다. 기존 Glass Optical Fiber의 굴절률 분포 측정 방법 중 가장 일반적이고 효과적인 방법 중 하나는 coherent 빛의 간섭을 이용한 transverse interferograms을 분석하는 방법으로 Fizeau 간섭계와 같은 간섭계를 이용하여 위상변화를 측정하고 측정한 위상을 tomography적인 해석방법을 통해 굴절률 분포를 계산하는 방법이다. (중략)

  • PDF

Development of an Automatic Transverse and Longitudinal Road Profile Measurement System (노면 종.횡단 요철 자동 측정 시스템 개발)

  • Eom, Jung-Hyun;Seo, Dong-Sun;Huh, Woong;Roo, Myong-Chan;Kim, Joon-Bum
    • Journal of IKEEE
    • /
    • v.5 no.1 s.8
    • /
    • pp.75-84
    • /
    • 2001
  • The reliable data relating to the condition of road surface is of increasing importance to deliver the road condition to driver and road management authority. This paper describes the development of a new high-speed. automatic, road data collection system, which collects the longitudinal road data with ${\sim}30cm$ interval covering full width of the road at 100km/h speed. The system calculates the international roughness index (IRI) from the collected data and displays the IRI and road profile data on the screen. To develope the system, we implement an optical range finder, advanced distance and motion detectors, and signal processing and display modules. The measurement accuracy of the system at 70km/h operation speed shows ${\pm}0.1m/km$ in the IRI for the standard road. To confirm the performance of the developed system, we also measure the IRI of a deployed highway road and compare the results with a conventional system and human eye measurement results.

  • PDF

Error Analysis for Electromagnetic Surface Velocity and Discharge Measurement in Rapid Mountain Stream Flow (산지하천의 전자파 표면유속 측정에 기반한 유량 및 유속 관측 오차 분석)

  • Kim, Dong-Su;Yang, Sung-Kee;Jung, Woo-Yul
    • Journal of Environmental Science International
    • /
    • v.23 no.4
    • /
    • pp.543-552
    • /
    • 2014
  • Fixed Electromagnetic Wave Surface Velocimetry (Fixed EWSV) has been started to be used to measure flood discharge in the mountain stream, since it has various advantages such that it works well to continuously measure stream discharge even in the night time as well as very strong weather. On the contrary, the Fixed EWSV only measures single point surface velocity, thus it does not consider varying feature of the transverse velocity profile in the given stream cross-section. In addition, a conventional value of 0.85 was generally used as the ratio for converting the measured surface velocity into the depth-averaged velocity. These aspects could bring in error for accurately measuring the stream discharge. The capacity of the EWSV for capturing rapid flow velocity was also not properly validated. This study aims at conducting error analysis of using the EWSV by: 1) measuring transverse velocity at multiple points along the cross-section to assess an error driven by the single point measurement; 2) figuring out ratio between surface velocity and the depth-averaged velocity based on the concurrent ADCP measurements; 3) validating the capacity of the EWSV for capturing rapid flow velocity. As results, the velocity measured near the center by the fixed EWSV overestimated about 15% of the cross-sectional mean velocity. The converting ratio from the surface velocity to the depth-averaged velocity was 0.8 rather than 0.85 of a conventional ratio. Finally, the EWSV revealed unstable velocity output when the flow velocity was higher than 2 m/s.

A Fundamental Study on Vibration Characteristics of Container Car for Sensitive Cargo Transportation according to ASTM D-4169 (ASTM 규격에 따른 민감화물 수송용 컨테이너 화차의 진동 특성에 관한 기초 연구)

  • Ki, Ho-Cheol;Lee, Seung-Yil;Kim, Chul-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.53-59
    • /
    • 2019
  • To reduce the vibrations and shocks during the cargo transportation of high value-added goods, the vibration history was measured on the truck transportation section (Asan-Uiwang) and the freight train transportation section (Uiwang-Pusan). The internal vibrations of the container were obtained by attaching acceleration sensors in three axis directions (longitudinal, lateral. and vertical directions) on the front and rear bogies. The rail vibration profile (0.29Grms) proposed in ASTM D-4169 was approximately 50% higher than the truck vibration profile (0.54Grms). The overall vibration was 16% and 33 % lower in the longitudinal and transverse directions, respectively, compared to the ASTM truck transport vibration profile. On the other hand, the vertical vibration measurement history partially exceeded the ASTM truck transport vibration profile over the range, 4 - 15Hz, and over 60Hz. The vibration measurement history of the cargo train was similar to that of the road. The longitudinal and lateral vibration history was lower than the ASTM D-4169 rail vibration profile, while the vertical history was over 30Hz.

Implementation of 3D Road Surface Monitoring System for Vehicle based on Line Laser (선레이저 기반 이동체용 3차원 노면 모니터링 시스템 구현)

  • Choi, Seungho;Kim, Seoyeon;Kim, Taesik;Min, Hong;Jung, Young-Hoon;Jung, Jinman
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.6
    • /
    • pp.101-107
    • /
    • 2020
  • Road surface measurement is an essential process for quantifying the degree and displacement of roughness in road surface management. For safer road surface management and quick maintenance, it is important to accurately measure the road surface while mounted on a vehicle. In this paper, we propose a sophisticated road surface measurement system that can be measured on a moving vehicle. The proposed road surface measurement system supports more accurate measurement of the road surface by using a high-performance line laser sensor. It is also possible to measure the transverse and longitudinal profile by matching the position information acquired from the RTK, and the velocity adaptive update algorithm allows a manager to monitor in a real-time manner. In order to evaluate the proposed system, the Gocator laser sensor, MRP module, and NVIDIA Xavier processor were mounted on a test mobile and tested on the road surface. Our evaluation results demonstrate that our system measures accurate profile base on the MSE. Our proposed system can be used not only for evaluating the condition of roads but also for evaluating the impact of adjacent excavation.

Numerical Analysis for Conductance Probes, for the Measurement of Liquid Film Thickness in Two-Phase Flow

  • No, Hee-Cheon;F. Mayinger
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.450-455
    • /
    • 1995
  • A three-dimensional numerical tool is developed to calculate the potential distribution, electric field, and conductance for any types of conductance probes immersed in the wavy liquid film with various shapes of its free surface. The tool is validated against various analytical solutions. It is applied to find out the characteristics of the wire-wire probe, the flush-wire probe and the flush-flush probe in terms of resolution, linearity, and sensitivity. The wire-wire probe shows high resolution and excellent linearity for various film thickness, but comparably low sensitivity for low film thickness fixed. The flush-wire probe shows good linearity and high sensitivity for varying film thickness, but resolution degrading with an increase in film thickness. In order to check the applicability of the three types of probes in the real situation, the Korteweg-de Vries(KdV) two-dimensional solitary wave is simulated. The wire-wire probe is strongly affected by the installation direction of the two wires; when the wires are installed perpendicularly to the flow direction, the wire-wire probe shows large distortion of the solitary wave. In order to measure the transverse profile of waves, the wire-wire probes and the flush-wire probes are required to be separately installed 2mm and 2mm, respectively.

  • PDF

A study on the Vibration Reduction of the Commercial High-speed Train (운영 중인 고속열차의 진동저감에 관한 연구)

  • Jeon, Chang-Sung;Choi, Sunghoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.697-704
    • /
    • 2017
  • This study was carried out to investigate and alleviate the vibration problem of commercial high-speed trains. First, the measurement of the carbody vibration was performed, in order to determine the vibration level of the high-speed train. The measurement result showed that the vibration level of the driver cab was higher than that of the passenger car and that the vibration became bigger toward the trailing end of the train. The vertical vibration of the driver cab and passenger car was larger than the transverse vibration, and the maximum value of the vibration in the ballast section was larger than that in the concrete section. A dynamic analysis was carried out to improve the vibration of the KTX-Sancheon train. The results of the analysis showed that it is necessary to reduce the vibration of the driver cab and both ends of the passenger cars. To reduce the vibration of the driver cab, it was recommended that the stiffness of the secondary coil spring be reduced and the damping coefficient of the secondary vertical damper be increased. It was found that the failure of the suspension system could be the origin of the vibration problem of the high-speed train. The proper management of wheel wear plays an important role in the improvement of the operation efficiency and reduction of the carbody vibration of high-speed trains, and research is underway to change the present wheel profile to increase the mileage between wheel turning.

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF