• Title/Summary/Keyword: Measurement of displacement

Search Result 1,215, Processing Time 0.034 seconds

The Development of Landslide Predictive System using Measurement Information based on u-IT (u-IT기반 계측정보를 이용한 급경사지붕괴 예측 시스템 개발)

  • Cheon, Dong-Jin;Park, Young-Jik;Lee, Seung-Ho;Kim, Jeong-Seop;Jung, Do-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.5115-5122
    • /
    • 2013
  • This paper has studied about the development and application of landslide collapse prediction real-time monitoring system based on USN to detect and measure the collapse of landslide. The rainfall measuring sensor, gap water pressure sensor, indicator displacement measuring sensor, index inclination sensor, water content sensor and image analysis sensor are selected and these are applied on the test bed. Each sensor's operation and performance for reliability verification is tested by the instrument which is installed in the field. As the result, u-IT based real-time landslide monitoring system which is developed by this research for landslide collapse detection could minimize life and property damages because it makes advance evacuation with collapse risk pre-estimate through real-time monitoring on roadside cut and bedrock slopes. This system is based on the results of this study demonstrate the effect escarpment plan are spread throughout.

A Study on the Correlation Improvement between FEA and Test for a Pedestrian Lower Legform Impact (보행자보호 Lower Legform 충격의 해석 대 시험 상관성 개선에 관한 연구)

  • Park, Dong-Kyou
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1515-1522
    • /
    • 2011
  • This paper proposed the finite element analysis technique for improving the correleration accuracy between FEA and test on a pedestrian lower legform impact. Europe has been evaluating the bumper pedestrian impact by Euro-NCAP, and it will also be applied in a domestic area by K-NCAP in 2013. By using the compression test result of bending resisting stiffener, a pedestrian bumper modeling guide was presented by analayzing the force-displacement curve of stiffener. And by using the sensor measurement results in car pedestrian test, pedestrian impact behavior was analyzed between test and finite element analysis result. Finally, the finite element analysis guide for a pedestrian bumper impact was presented to improve the correleration accuracy.

Technology of Non-destructive Stress Measurement in Spot Welded Joint using ESPI Method (ESPI법에 의한 스폿 용접부의 비파괴적 응력측정 기술)

  • 김덕중;국정한;오세용;김봉중;유원일;김영호
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.1
    • /
    • pp.23-26
    • /
    • 2000
  • In spot welded joint. Electronic Speckle Pattern Interferometry(ESPI) method using the Model 95 Ar laser a video system and an image processor was applied to measure the stress Unlike traditional strain gauges or Moire method, ESPI method has no special surface preparation or attachments and can be measured in-plane displacement with non-contact and real time. In this experiment, specimens are loaded in parallel with a load cell. The specimens are made of the cold rolled steel sheet with 1mm thickness, are attached strain. gauges. This study Provides an example of how ESPI has been used to measure stress and strain inspecimen. The results measured by ESPI are compared with the data which was measured by strain gauge method under tensile testing.

  • PDF

Analysis of Unrest Signs of Activity at the Baegdusan Volcano (백두산 화산의 전조활동 분석 연구)

  • Yun, Sung-Hyo;Lee, Jeong-Hyun
    • The Journal of the Petrological Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.1-12
    • /
    • 2012
  • The Baegdusan volcano is one of the most active volcanoes in northeastern Asia, and the 10th century eruption was the most voluminous eruption in the world in recent 2,000 years. During the period from 2002 to 2005, volcanic earthquakes and abnormal surface distortions by suspected subsurface magma intrusion beneath the volcano were observed in the Baegdusan area. Seismic activity has gradually increased with earthquake swarms during 2002-2003 and hundreds of seismic event in a day, especially annual peak of 2,100 in 2003. Then the number of seismic activity has declined since 2006 to the background level in 1999-2001. According to the typical frequency of volcanic earthquakes in the Baegdusan volcano, the frequency distribution of typical volcanic earthquakes between 2002 and 2005 indicates that all the main frequency of the earthquakes basically falls down less than 5 Hz and 5-10 Hz. These events are all the VT-B and LP events caused by the shallow localized fracture and intrusion of magma. The horizontal displacement measurement by GPS during the period from 2000 to 2007 of the Baegdusan stratovolcano area indicates that an inflated process has been centered at the summit caldera since 2002. The displacement between 2002 and 2003 reached at a maximum value of 4 cm. After 2003, the deformation rate of the volcano continued to decrease with unusual variation during the period from 2006 to 2007. After 2003 the vertical displacement uplift rate falls down gradually but still keeps in an uplift trend in northern slope. It is generally believed that when $^3He/^4He(R)$ in a gas sample from a hot spring exceeds $^3He/^4He(R)$ in the atmosphere, it can be concluded that mantle-source. And temperatures of hot springs are rising steadily to $83^{\circ}C$. It is unrest signals at the Baegdusan, which is potentially active. The Baegdusan volcano is now in unrest status, there is eruption threat in the near future. Intensified monitoring and emergency response plan for volcanic risk mitigation are urgent for the volcano.

Evaluation of Dose Reduction of Cardiac Exposure Using Deep-inspiration Breath Hold Technique in Left-sided Breast Radiotherapy (좌측 유방암 방사선 치료에서 깊은 들숨 호흡법을 이용한 심장 선량 감소 평가)

  • Jung, Joo-Young;Kim, Min-Joo;Jung, Jae-Hong;Lee, Seu-Ran;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.278-283
    • /
    • 2013
  • Breast cancer is the leading cause of cancer death in women worldwide and the number of women breast cancer patient was increased continuously. Most of breast cancer patient has suffered from unnecessary radiation exposure to heart, lung. Low radiation dose to the heart could lead to the worsening of preexisting cardiovascular lesions caused by radiation induced pneumonitis. Also, several statistical reports demonstrated that left-sided breast cancer patient showed higher mortality than right-sided breast cancer patient because of heart disease. In radiation therapy, Deep Inspiration Breath Hold (DIBH) technique which the patient takes a deep inspiration and holds during treatment and could move the heart away from the chest wall and lung, has showed to lead to reduction in cardiac volume and to minimize the unnecessary radiation exposure to heart during treatment. In this study, we investigated the displacement of heart using DIBH CT data compared to free-breathing (FB) CT data and radiation exposure to heart. Treatment planning was performed on the computed tomography (CT) datasets of 10 patients who had received lumpectomy treatments. Heart, lung and both breasts were outlined. The prescribed dose was 50 Gy divided into 28 fractions. The dose distributions in all the plans were required to fulfill the International Commission on Radiation Units and Measurement specifications that include 100% coverage of the CTV with ${\geq}95%$ of the prescribed dose and that the volume inside the CTV receiving >107% of the prescribed dose should be minimized. Scar boost irradiation was not performed in this study. Displacement of heart was measured by calculating the distance between center of heart and left breast. For the evaluation of radiation dose to heart, minimum, maximum and mean dose to heart were calculated. The present study demonstrates that cardiac dose during left-sided breast radiotherapy can be reduced by applying DIBH breathing control technique.

PREPARATION OF AMORPHOUS CARBON NITRIDE FILMS AND DLC FILMS BY SHIELDED ARC ION PLATING AND THEIR TRIBOLOGICAL PROPERTIES

  • Takai, Osamu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.3-4
    • /
    • 2000
  • Many researchers are interested in the synthesis and characterization of carbon nitride and diamond-like carbon (DLq because they show excellent mechanical properties such as low friction and high wear resistance and excellent electrical properties such as controllable electical resistivity and good field electron emission. We have deposited amorphous carbon nitride (a-C:N) thin films and DLC thin films by shielded arc ion plating (SAIP) and evaluated the structural and tribological properties. The application of appropriate negative bias on substrates is effective to increase the film hardness and wear resistance. This paper reports on the deposition and tribological OLC films in relation to the substrate bias voltage (Vs). films are compared with those of the OLC films. A high purity sintered graphite target was mounted on a cathode as a carbon source. Nitrogen or argon was introduced into a deposition chamber through each mass flow controller. After the initiation of an arc plasma at 60 A and 1 Pa, the target surface was heated and evaporated by the plasma. Carbon atoms and clusters evaporated from the target were ionized partially and reacted with activated nitrogen species, and a carbon nitride film was deposited onto a Si (100) substrate when we used nitrogen as a reactant gas. The surface of the growing film also reacted with activated nitrogen species. Carbon macropartic1es (0.1 -100 maicro-m) evaporated from the target at the same time were not ionized and did not react fully with nitrogen species. These macroparticles interfered with the formation of the carbon nitride film. Therefore we set a shielding plate made of stainless steel between the target and the substrate to trap the macropartic1es. This shielding method is very effective to prepare smooth a-CN films. We, therefore, call this method "shielded arc ion plating (SAIP)". For the deposition of DLC films we used argon instead of nitrogen. Films of about 150 nm in thickness were deposited onto Si substrates. Their structures, chemical compositions and chemical bonding states were analyzed by using X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy and infrared spectroscopy. Hardness of the films was measured with a nanointender interfaced with an atomic force microscope (AFM). A Berkovich-type diamond tip whose radius was less than 100 nm was used for the measurement. A force-displacement curve of each film was measured at a peak load force of 250 maicro-N. Load, hold and unload times for each indentation were 2.5, 0 and 2.5 s, respectively. Hardness of each film was determined from five force-displacement curves. Wear resistance of the films was analyzed as follows. First, each film surface was scanned with the diamond tip at a constant load force of 20 maicro-N. The tip scanning was repeated 30 times in a 1 urn-square region with 512 lines at a scanning rate of 2 um/ s. After this tip-scanning, the film surface was observed in the AFM mode at a constant force of 5 maicro-N with the same Berkovich-type tip. The hardness of a-CN films was less dependent on Vs. The hardness of the film deposited at Vs=O V in a nitrogen plasma was about 10 GPa and almost similar to that of Si. It slightly increased to 12 - 15 GPa when a bias voltage of -100 - -500 V was applied to the substrate with showing its maximum at Vs=-300 V. The film deposited at Vs=O V was least wear resistant which was consistent with its lowest hardness. The biased films became more wear resistant. Particularly the film deposited at Vs=-300 V showed remarkable wear resistance. Its wear depth was too shallow to be measured with AFM. On the other hand, the DLC film, deposited at Vs=-l00 V in an argon plasma, whose hardness was 35 GPa was obviously worn under the same wear test conditions. The a-C:N films show higher wear resistance than DLC films and are useful for wear resistant coatings on various mechanical and electronic parts.nic parts.

  • PDF

Review of Remote Sensing Studies on Groundwater Resources (원격탐사의 지하수 수자원 적용 사례 고찰)

  • Lee, Jeongho
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_3
    • /
    • pp.855-866
    • /
    • 2017
  • Several research cases using remote sensing methods to analyze changes of storage and dynamics of groundwater aquifer were reviewed in this paper. The status of groundwater storage, in an area with regional scale, could be qualitatively inferred from geological feature, surface water altimetry and topography, distribution of vegetation, and difference between precipitation and evapotranspiration. These qualitative indicators could be measured by geological lineament analysis, airborne magnetic survey, DEM analysis, LAI and NDVI calculation, and surface energy balance modeling. It is certain that GRACE and InSAR have received remarkable attentions as direct utilization from satellite data for quantification of groundwater storage and dynamics. GRACE, composed of twin satellites having acceleration sensors, could detect global or regional microgravity changes and transform them into mass changes of water on surface and inside of the Earth. Numerous studies in terms of groundwater storage using GRACE sensor data were performed with several merits such that (1) there is no requirement of sensor data, (2) auxiliary data for quantification of groundwater can be entirely obtained from another satellite sensors, and (3) algorithms for processing measured data have continuously progressed from designated data management center. The limitations of GRACE for groundwater storage measurement could be defined as follows: (1) In an area with small scale, mass change quantification of groundwater might be inaccurate due to detection limit of the acceleration sensor, and (2) the results would be overestimated in case of combination between sensor and field survey data. InSAR can quantify the dynamic characteristics of aquifer by measuring vertical micro displacement, using linear proportional relation between groundwater head and vertical surface movement. However, InSAR data might now constrain their application to arid or semi-arid area whose land cover appear to be simple, and are hard to apply to the area with the anticipation of loss of coherence with surface. Development of GRACE and InSAR sensor data preprocessing algorithms optimized to topography, geology, and natural conditions of Korea should be prioritized to regionally quantify the mass change and dynamics of the groundwater resources of Korea.

Optimum Design of Soil Nailing Excavation Wall System Using Genetic Algorithm and Neural Network Theory (유전자 알고리즘 및 인공신경망 이론을 이용한 쏘일네일링 굴착벽체 시스템의 최적설계)

  • 김홍택;황정순;박성원;유한규
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.4
    • /
    • pp.113-132
    • /
    • 1999
  • Recently in Korea, application of the soil nailing is gradually extended to the sites of excavations and slopes having various ground conditions and field characteristics. Design of the soil nailing is generally carried out in two steps, The First step is to examine the minimum safety factor against a sliding of the reinforced nailed-soil mass based on the limit equilibrium approach, and the second step is to check the maximum displacement expected to occur at facing using the numerical analysis technique. However, design parameters related to the soil nailing system are so various that a reliable design method considering interrelationships between these design parameters is continuously necessary. Additionally, taking into account the anisotropic characteristics of in-situ grounds, disturbances in collecting the soil samples and errors in measurements, a systematic analysis of the field measurement data as well as a rational technique of the optimum design is required to improve with respect to economical efficiency. As a part of these purposes, in the present study, a procedure for the optimum design of a soil nailing excavation wall system is proposed. Focusing on a minimization of the expenses in construction, the optimum design procedure is formulated based on the genetic algorithm. Neural network theory is further adopted in predicting the maximum horizontal displacement at a shotcrete facing. Using the proposed procedure, various effects of relevant design parameters are also analyzed. Finally, an optimized design section is compared with the existing design section at the excavation site being constructed, in order to verify a validity of the proposed procedure.

  • PDF

Quantitative analysis of the TMJ movement with a new mandibular movement tracking and simulation system

  • Kim, Dae-Seung;Hwang, Soon-Jung;Choi, Soon-Chul;Lee, Sam-Sun;Heo, Min-Suk;Heo, Kyung-Hoe;Yi, Won-Jin
    • Imaging Science in Dentistry
    • /
    • v.38 no.4
    • /
    • pp.203-208
    • /
    • 2008
  • Purpose : The purpose of this study was to develop a system for the measurement and simulation of the TMJ movement and to analyze the mandibular movement quantitatively. Materials and Methods : We devised patient-specific splints and a registration body for the TMJ movement tracking. The mandibular movements of the 12 subjects with facial deformity and 3 controls were obtained by using an optical tracking system and the patient-specific splints. The mandibular part was manually segmented from the CT volume data of a patient. Three-dimensional surface models of the maxilla and the mandible were constructed using the segmented data. The continuous movement of the mandible with respect to the maxilla could be simulated by applying the recorded positions sequentially. Trajectories of the selected reference points were calculated during simulation and analyzed. Results : The selected points were the most superior point of bilateral condyle, lower incisor point, and pogonion. There were significant differences (P<0.05) between control group and pre-surgical group in the maximum displacement of left superior condyle, lower incisor, and pogonion in vertical direction. Differences in the maximum lengths of the right and the left condyle were 0.59${\pm}$0.30 mm in pre-surgical group and 2.69${\pm}$2.63 mm in control group, which showed a significant difference (P<0.005). The maximum of differences between lengths of the right and the left calculated during one cycle also showed a significant difference between two groups (P<0.05). Conclusion : Significant differences in mandibular movements between the groups implies that facial deformity have an effect on the movement asymmetry of the mandible. (Korean J Oral Maxillofac Radiol 2008; 38 : 203-8)

  • PDF

The Crystallographic and Magnetic Properties of $Fe_{1-x}Co_x$System ($Fe_{1-x}Co_x$계의 결정구조와 자기적인 성질)

  • 김정기;한경훈;서정철
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.4
    • /
    • pp.190-195
    • /
    • 1999
  • The crystallographic and magnetic properties of the system of $Fe_{1-x}Co_x$(x=0.2 and 0.4) prepared by microwave arc-melting with the maximum power of 3.5 kW and a iron-foil with thickness of 25 ${\mu}{\textrm}{m}$ have been studied by the methods of X-ray diffraction and the measurement of the magnetic hysteresis using the vibrating sample magnetometer at room temperature. The samples were prepared in three different ways: First, pellet form pressed under the pressure of 9,000 N/$\textrm{cm}^2$. Second, the sheet cold rolled. Third, thin sheet treated with the temperature of 90$0^{\circ}C$. The X-ray diffraction pattern of the sample prepared by the first method shows that the crystal structure of the sample is bcc as same as that of Fe with a good uniformity. The iron-foil has the coercivity of 43 Oe and the initial slope of magnetization of 0.328 emu/gOe. The coervicity and magnetization of the sample prepared by the second method increased as the Co content increased. But the initial slop of the magnetization decreased as the Co content increased. This means that the displacement of domain wall is suppressed by the increases of coercivity as the Co content increased. The saturation magnetization of the samples made by the third method increased. On the other hand, the coercivity of these samples decreased. The increase of saturation magnetization of the samples seems to be related to the changes in X-ray intensity after heat treatment. Also some magnetic parameters of the samples were calculated by using a simple model and compared with other values.

  • PDF