• Title/Summary/Keyword: Measurement methods

Search Result 8,110, Processing Time 0.042 seconds

Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF

Four-year change and tracking of serum lipids in Korean adolescents (강화지역 청소년의 4년간 혈청 지질의 변화와 지속성)

  • Lee, Kang-Hee;Suh, Il;Jee, Sun-Ha;Nam, Chung-Mo;Kim, Sung-Soon;Shim, Won-Heum;Ha, Jong-Won;Kim, Suk-Il;Kang, Hyung-Gon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.1 s.56
    • /
    • pp.45-59
    • /
    • 1997
  • It has been known that there is a tracking phenomenon in the level of serum lipids. However, no study has been performed to examine the change and tracking of serum lipids in Korean adolescents. The purpose of this study is to examine the changes of serum lipids in Korean adolescents from 12 to 16 years of age, and to examine whether or not there is a tracking phenomenon in serum lipids level during the period. In 1992 serum lipids(total cholesterol(TC), triglyceride(TG), LDL cholesterol(LDL-C), HDL cholesterol(HDL-C)) were measured in 318 males, 365 females who were 12 years of age in Kangwha county, Korea. These participants have been followed up to 1996 and serum lipids level were examined in 1994 and 1996. Among the participants 162 males and 147 females completed all three examinations in fasting state. To examine the effect of eliminating adolescents with incomplete data, we compared serum lipids, blood pressure and anthropometric measures at baseline between adolescents with complete follow-up and adolescents who were withdrawn. To examine the change of serum lipids we compared mean values of serum lipids according to age in males and females. Repeated analysis of variance was used to test the change according to age. We used three methods to examine the existence of tracking. First, we analyzed the trends in serum lipids over 4-year period within quartile groups formed on the basis of the first-year serum lipids level to see whether or not the relative ranking of the mean serum lipids among the quartile groups remained in the same group for 4-year period. Second, we quantified the degree of tracking by calculating Spearman's rank correlation coefficient between every tests. Third, the persistence extreme quartile method was used. This method divides the population into quartile groups according to the initial level of blood lipids and then calculates the percent of the subjects who stayed in the same group at follow-up measurement. The decreases in levels were noted during 4 years for TC, LDL-C, primarily for boys. The level of HDL-C decreased between baseline and first follow-up for both sexes. Tracking, as measured by both correlation coefficients and persistence extreme quartiles, was evident for all of the lipids. The correlation coefficients of TC between baseline and 4 years later in boys and girls were 0.55 and 0.68, respectively. And the corresponding values for HDL-C were 0.58 and 0.69. More than 50% of adolescents who belonged to the highest quartile group in TC, HDL-C and LDL-C at the baseline were remained at the same group at the examination performed 2 years later for both sexes. The probabilities of remaining at the same group were more than 35% when examined 4 years later. The tracking phenomenon of TG was less evident compared with the other lipids. Percents of girls who stayed at the same group 2 years later and 4 years later were 42.9% and 25.7%, respectively. It was evident that serum lipid levels tracked in Korean adolescents. Researches with longer follow-up would be needed in the future to investigate the long-term change of lipids from adolescents to adults.

  • PDF

Effect of Service Convenience on the Relationship Performance in B2B Markets: Mediating Effect of Relationship Factors (B2B 시장에서의 서비스 편의성이 관계성과에 미치는 영향 : 관계적 요인의 매개효과 분석)

  • Han, Sang-Lin;Lee, Seong-Ho
    • Journal of Distribution Research
    • /
    • v.16 no.4
    • /
    • pp.65-93
    • /
    • 2011
  • As relationship between buyer and seller has been brought closer and long-term relationship has been more important in B2B markets, the importance of service and service convenience increases as well as product. In homogeneous markets, where service offerings are similar and therefore not key competitive differentiator, providing greater convenience may enable a competitive advantage. Service convenience, as conceptualized by Berry et al. (2002), is defined as the consumers' time and effort perceptions related to buying or using a service. For this reason, B2B customers are interested in how fast the service is provided and how much save non-monetary cost like time or effort by the service convenience along with service quality. Therefore, this study attempts to investigate the impact of service convenience on relationship factors such as relationship satisfaction, relationship commitment, and relationship performance. The purpose of this study is to find out whether service convenience can be a new antecedent of relationship quality and relationship performance. In addition, this study tries to examine how five-dimensional service convenience constructs (decision convenience, access convenience, transaction convenience, benefit convenience, post-benefit convenience) affect customers' relationship satisfaction, relationship commitment, and relationship performance. The service convenience comprises five fundamental components - decision convenience (the perceived time and effort costs associated with service purchase or use decisions), access convenience(the perceived time and effort costs associated with initiating service delivery), transaction convenience(the perceived time and effort costs associated with finalizing the transaction), benefit convenience(the perceived time and effort costs associated with experiencing the core benefits of the offering) and post-benefit convenience (the perceived time and effort costs associated with reestablishing subsequent contact with the firm). Earlier studies of perceived service convenience in the industrial market are none. The conventional studies that have dealt with service convenience have usually been made in the consumer market, or they have dealt with convenience aspects in the service process. This service convenience measure for consumer market can be useful tool to estimate service quality in B2B market. The conceptualization developed by Berry et al. (2002) reflects a multistage, experiential consumption process in which evaluations of convenience vary at each stage. For this reason, the service convenience measure is good for B2B service environment which has complex processes and various types. Especially when categorizing B2B service as sequential stage of service delivery like Kumar and Kumar (2004), the Berry's service convenience measure which reflect sequential flow of service deliveries suitable to establish B2B service convenience. For this study, data were gathered from respondents who often buy business service and analyzed by structural equation modeling. The sample size in the present study is 119. Composite reliability values and average variance extracted values were examined for each variable to have reliability. We determine whether the measurement model supports the convergent validity by CFA, and discriminant validity was assessed by examining the correlation matrix of the constructs. For each pair of constructs, the square root of the average variance extracted exceeded their correlations, thus supporting the discriminant validity of the constructs. Hypotheses were tested using the Smart PLS 2.0 and we calculated the PLS path values and followed with a bootstrap re-sampling method to test the hypotheses. Among the five dimensional service convenience constructs, four constructs (decision convenience, transaction convenience, benefit convenience, post-benefit convenience) affected customers' positive relationship satisfaction, relationship commitment, and relationship performance. This result means that service convenience is important cue to improve relationship between buyer and seller. One of the five service convenience dimensions, access convenience, does not affect relationship quality and performance, which implies that the dimension of service convenience is not important factor of cumulative satisfaction. The Cumulative satisfaction can be distinguished from transaction-specific customer satisfaction, which is an immediate post-purchase evaluative judgment or an affective reaction to the most recent transactional experience with the firm. Because access convenience minimizes the physical effort associated with initiating an exchange, the effect on relationship satisfaction similar to cumulative satisfaction may be relatively low in terms of importance than transaction-specific customer satisfaction. Also, B2B firms focus on service quality, price, benefit, follow-up service and so on than convenience of time or place in service because it is relatively difficult to change existing transaction partners in B2B market compared to consumer market. In addition, this study using partial least squares methods reveals that customers' satisfaction and commitment toward relationship has mediating role between the service convenience and relationship performance. The result shows that management and investment to improve service convenience make customers' positive relationship satisfaction, and then the positive relationship satisfaction can enhance the relationship commitment and relationship performance. And to conclude, service convenience management is an important part of successful relationship performance management, and the service convenience is an important antecedent of relationship between buyer and seller such as the relationship commitment and relationship performance. Therefore, it has more important to improve relationship performance that service providers enhance service convenience although competitive service development or service quality improvement is important. Given the pressure to provide increased convenience, it is not surprising that organizations have made significant investments in enhancing the convenience aspect of their product and service offering.

  • PDF

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Implementation of integrated monitoring system for trace and path prediction of infectious disease (전염병의 경로 추적 및 예측을 위한 통합 정보 시스템 구현)

  • Kim, Eungyeong;Lee, Seok;Byun, Young Tae;Lee, Hyuk-Jae;Lee, Taikjin
    • Journal of Internet Computing and Services
    • /
    • v.14 no.5
    • /
    • pp.69-76
    • /
    • 2013
  • The incidence of globally infectious and pathogenic diseases such as H1N1 (swine flu) and Avian Influenza (AI) has recently increased. An infectious disease is a pathogen-caused disease, which can be passed from the infected person to the susceptible host. Pathogens of infectious diseases, which are bacillus, spirochaeta, rickettsia, virus, fungus, and parasite, etc., cause various symptoms such as respiratory disease, gastrointestinal disease, liver disease, and acute febrile illness. They can be spread through various means such as food, water, insect, breathing and contact with other persons. Recently, most countries around the world use a mathematical model to predict and prepare for the spread of infectious diseases. In a modern society, however, infectious diseases are spread in a fast and complicated manner because of rapid development of transportation (both ground and underground). Therefore, we do not have enough time to predict the fast spreading and complicated infectious diseases. Therefore, new system, which can prevent the spread of infectious diseases by predicting its pathway, needs to be developed. In this study, to solve this kind of problem, an integrated monitoring system, which can track and predict the pathway of infectious diseases for its realtime monitoring and control, is developed. This system is implemented based on the conventional mathematical model called by 'Susceptible-Infectious-Recovered (SIR) Model.' The proposed model has characteristics that both inter- and intra-city modes of transportation to express interpersonal contact (i.e., migration flow) are considered. They include the means of transportation such as bus, train, car and airplane. Also, modified real data according to the geographical characteristics of Korea are employed to reflect realistic circumstances of possible disease spreading in Korea. We can predict where and when vaccination needs to be performed by parameters control in this model. The simulation includes several assumptions and scenarios. Using the data of Statistics Korea, five major cities, which are assumed to have the most population migration have been chosen; Seoul, Incheon (Incheon International Airport), Gangneung, Pyeongchang and Wonju. It was assumed that the cities were connected in one network, and infectious disease was spread through denoted transportation methods only. In terms of traffic volume, daily traffic volume was obtained from Korean Statistical Information Service (KOSIS). In addition, the population of each city was acquired from Statistics Korea. Moreover, data on H1N1 (swine flu) were provided by Korea Centers for Disease Control and Prevention, and air transport statistics were obtained from Aeronautical Information Portal System. As mentioned above, daily traffic volume, population statistics, H1N1 (swine flu) and air transport statistics data have been adjusted in consideration of the current conditions in Korea and several realistic assumptions and scenarios. Three scenarios (occurrence of H1N1 in Incheon International Airport, not-vaccinated in all cities and vaccinated in Seoul and Pyeongchang respectively) were simulated, and the number of days taken for the number of the infected to reach its peak and proportion of Infectious (I) were compared. According to the simulation, the number of days was the fastest in Seoul with 37 days and the slowest in Pyeongchang with 43 days when vaccination was not considered. In terms of the proportion of I, Seoul was the highest while Pyeongchang was the lowest. When they were vaccinated in Seoul, the number of days taken for the number of the infected to reach at its peak was the fastest in Seoul with 37 days and the slowest in Pyeongchang with 43 days. In terms of the proportion of I, Gangneung was the highest while Pyeongchang was the lowest. When they were vaccinated in Pyeongchang, the number of days was the fastest in Seoul with 37 days and the slowest in Pyeongchang with 43 days. In terms of the proportion of I, Gangneung was the highest while Pyeongchang was the lowest. Based on the results above, it has been confirmed that H1N1, upon the first occurrence, is proportionally spread by the traffic volume in each city. Because the infection pathway is different by the traffic volume in each city, therefore, it is possible to come up with a preventive measurement against infectious disease by tracking and predicting its pathway through the analysis of traffic volume.

Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea (우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량)

  • Lee, Kwang-Yong;Lee, Byung-Young;Lee, Jung-Eun;Lee, Hyun-Koo;Jung, Seung-Hwan;Kim, Byung-Woo;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.401-410
    • /
    • 2009
  • Purpose : Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. Methods : The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. Results : According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60~97 kVp, with the average use being 75 kVp, and the tube current ranged between 8~123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65~100 kVp (average use: 78 kVp) and 70~109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10~100 mAs(average use: 35 mAs) and between 8.9~300 mAs(average use: 64 mAs), respectively. The measurements of entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. Conclusions : The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  • PDF

A Study on The 'Kao Zheng Pai'(考證派) of The Traditional Medicine of Japan (일본 '고증파(考證派)' 의학에 관한 연구)

  • Park, Hyun-Kuk;Kim, Ki-Wook
    • Journal of Korean Medical classics
    • /
    • v.20 no.4
    • /
    • pp.211-250
    • /
    • 2007
  • 1. The 'Kao Zheng Pai(考證派) comes from the 'Zhe Zhong Pai' and is a school that is influenced by the confucianism of the Qing dynasty. In Japan Inoue Kinga(井上金娥), Yoshida Koton(吉田篁墩) became central members, and the rise of the methodology of historical research(考證學) influenced the members of the 'Zhe Zhong Pai', and the trend of historical research changed from confucianism to medicine, making a school of medicine based on the study of texts and proving that the classics were right. 2. Based on the function of 'Nei Qu Li '(內驅力) the 'Kao Zheng Pai', in the spirit of 'use confucianism as the base', researched letters, meanings and historical origins. Because they were influenced by the methodology of historical research(考證學) of the Qing era, they valued the evidential research of classic texts, and there was even one branch that did only historical research, the 'Rue Xue Kao Zheng Pai'(儒學考證派). Also, the 'Yi Xue Kao Zheng Pai'(醫學考證派) appeared by the influence of Yoshida Kouton and Kariya Ekisai(狩谷掖齋). 3. In the 'Kao Zheng Pai(考證派)'s theories and views the 'Yi Xue Kao Zheng Pai' did not look at medical scriptures like the "Huang Di Nei Jing"("黃帝內經") and did not do research on 'medical' related areas like acupuncture, the meridian and medicinal herbs. Since they were doctors that used medicine, they naturally were based on 'formulas'(方劑) and since their thoughts were based on the historical ideologies, they valued the "Shang Han Ja Bing Lun" which was revered as the 'ancestor of all formulas'(衆方之祖). 4. The lives of the important doctors of the 'Kao Zheng Pai' Meguro Dotaku(目黑道琢) Yamada Seichin(山田正珍), Yamada Kyoko(山田業廣), Mori Ritsi(森立之) Kitamura Naohara(喜多村直寬) are as follows. 1) Meguro Dotaku(目黑道琢 1739${\sim}$1798) was born of lowly descent but, using his intelligence and knowledge, became a professor as a Shi Jing Yi(市井醫) and as a professor for 34 years at Ji Shou Guan mastered the "Huang Di Nei Jing" after giving over 300 lectures. Since his pupil, Isawara Ken taught the Lan Men Wu Zhe(蘭門五哲) and Shibue Chusai, Mori Ritsi(森立之), Okanishi Gentei(岡西玄亭), Kiyokawa Gendoh(淸川玄道) and Yamada Kyoko(山田業廣), Meguro Dotaku is considered the founder of the 'Yi Xue Kao Zheng Pai'. 2) The family of Yamada Seichin(山田正珍 1749${\sim}$1787) had been medical officials in the Makufu(幕府) and the many books that his ancestors had left were the base of his art. Seichin learned from Shan Ben Bei Shan(山本北山), a 'Zhe Zhong Pai' scholar, and put his efforts into learning, teaching and researching the "Shang Han Lun"("傷寒論"). Living in a time between 'Gu Fang Pai'(古方派) member Nakanishi Goretada(中西惟忠) and 'Kao Zheng Pai' member Taki Motohiro(多紀元簡), he wrote 11 books, 2 of which express his thoughts and research clearly, the "Shang Han Lun Ji Cheng"("傷寒論集成") and "Shang Han Kao"("傷寒考"). His comparison of the 'six meridians'(3 yin, 3 yang) between the "Shang Han Lun" and the "Su Wen Re Lun"("素問 熱論) and his acknowledgement of the need and rationality of the concept of Yin-Yang and Deficient-Replete distinguishes him from the other 'Gu Fang Pai'. Also, his dissertation of the need for the concept doesn't use the theories of latter schools but uses the theory of the "Shang Han Lun" itself. He even researched the historical parts, such as terms like 'Shen Nong Chang Bai Cao'(神農嘗百草) and 'Cheng Qi Tang'(承氣湯) 3) The ancestor of Yamada Kyoko(山田業廣) was a court physician, and learned confucianism from Kao Zheng Pai 's Ashikawa Genan(朝川善庵) and medicine from Isawa Ranken and Taki Motokata(多紀元堅), and the secret to smallpox from Ikeda Keisui(池田京水). He later became a lecturer at the Edo Yi Xue Guan(醫學館) and was invited as the director to the Ji Zhong(濟衆) hospital. He also became the first owner of the Wen Zhi She(溫知社), whose main purpose was the revival of kampo, and launched the monthly magazine Wen Zi Yi Tan(溫知醫談). He also diagnosed and prescribed for the prince Ming Gong(明宮). His works include the "Jing Fang Bian"("經方辨"), "Shang Han Lun Si Ci"("傷寒論釋司"), "Huang Zhao Zhu Jia Zhi Yan Ji Yao"("皇朝諸家治驗集要") and "Shang Han Ja Bing Lun Lei Juan"("傷寒雜病論類纂"). of these, the "Jing Fang Bian"("經方辨") states that the Shi Gao(石膏) used in the "Shang Han Lun" had three meanings-Fa Biao(發表), Qing Re(淸熱), Zi Yin(滋陰)-which were from 'symptoms', and first deducted the effects and then told of the reason. Another book, the "Jiu Zhe Tang Du Shu Ji"("九折堂讀書記") researched and translated the difficult parts of the "Shang Han Lun", "Jin Qui Yao Lue", "Qian Jin Fang"("千金方"), and "Wai Tai Mi Yao"("外臺秘要"). He usually analyzed the 'symptoms' of diseases but the composition, measurement, processing and application of medicine were all in the spectrum of 'analystic research' and 'researching analysis'. 4) The ancestors of Mori Rits(森立之 1807${\sim}$ 1885) were warriors but he became a doctor by the will of his mother, and he learned from Shibue Chosai(澁江抽齋) and Isawaran Ken and later became a pupil of Shou Gu Yi Zhai, a historical research scholar. He then became a lecturer of medical herbs at the Yi Xue Guan, and later participated in the proofreading of "Yi Xin Fang"("醫心方") and with Chosai compiled the "Jing Ji Fang Gu Zhi"("神農本草經"). He visited the Chinese scholar Yang Shou Jing(楊守敬) in 1881 and exchanged books and ideas. Of his works, there are the collections(輯複本) of "Shen Nong Ben Cao Jing"(神農本草經) and "You Xiang Yi Hwa"("遊相醫話") and the records, notes, poems, and diaries such as "Zhi Yuan Man Lu"("枳園漫錄") and "Zhi Yuan Sui Bi"("枳園隨筆") that were not published. His thoughts were that in restoring the "Shen Nong Ben Cao Jing", "the herb to the doctor is like the "Shuo Wen Jie Zi"("說文解字") to the scholar", and he tried to restore the ancient herbal text using knowledge of medicine and investigation(考據). Also with Chosai he compiled the "Jing Ji Fang Gu Zhi"("經籍訪古志") using knowledge of ancient text. Ritzi left works on pure investigation, paid much attention to social problems, and through 12 years of poverty treated all people and animals in all branches of medicine, so he is called a 'half confucianist half doctor'(半儒半醫). 5) Kitamurana Ohira(喜多村直寬 1804${\sim}$1876) learned scriptures and ancient texts from confucian scholar Asaka Gonsai, and learned medicine from his father Huai Yaun(槐園). He became a teacher in the Yi Xue Guan in his middle ages, and to repay his country, he printed 266 volumes of "Yi Fang Lei Ju("醫方類聚") and 1000 volumes of "Tai Ping Yu Lan"("太平禦覽") and devoted it to his country to be spread. His works are about 40 volumes including "Jin Qui Yao Lue Shu Yi" and "Lao Yi Zhi Yan" but most of them are researches on the "Shang Han Za Bing Lun". In his "Shang Han Lun Shu Yi"("傷寒論疏義") he shows the concept of the six meridians through the Yin-Yang, Superficial or internal, cold or hot, deficient or replete state of diseases, but did not match the names with the six meridians of the meridian theory, and this has something in common with the research based on the confucianism of Song(宋儒). In clinical treatment he was positive toward old and new methods and also the experience of civilians, but was negative toward western medicine. 6) The ancestor of the Taki family Tanbano Yasuyori(丹波康賴 912-955) became a Yi Bo Shi(醫博士) by his medical skills and compiled the "Yi Xin Fang"("醫心方"). His first son Tanbano Shigeaki(丹波重明) inherited the Shi Yao Yuan(施藥院) and the third son Tanbano Masatada(丹波雅忠) inherited the Dian You Tou(典藥頭). Masatada's descendents succeeded him for 25 generations until the family name was changed to Jin Bao(金保) and five generations later it was changed again to Duo Ji(多紀). The research scholar Taki Motohiro was in the third generation after the last name was changed to Taki, and his family kept an important part in the line of medical officers in Japan. Taki Motohiro(多紀元簡 1755-1810) was a teacher in the Yi Xue Guan where his father was residing, and became the physician for the general Jia Qi(家齊). He had a short temper and was not good at getting on in the world, and went against the will of the king and was banished from Ao Yi Shi(奧醫師). His most famous works, the "Shang Han Lun Ji Yi" and "Jin Qui Yao Lue Ji Yi" are the work of 20 years of collecting the theories of many schools and discussing, and is one of the most famous books on the "Shang Han Lun" in Japan. "Yi Sheng" is a collection of essays on research. Also there are the "Su Wen Shi"("素問識"), "Ling Shu Shi"("靈樞識"), and the "Guan lu Fang Yao Bu"("觀聚方要補"). Taki Motohiro(多紀元簡)'s position was succeeded by his third son Yuan Yin(元胤 1789-1827), and his works include works of research such as "Nan Jing Shu Jeng"("難經疏證"), "Ti Ya"("體雅"), "Yao Ya"("藥雅"), "Ji Ya"("疾雅"), "Ming Yi Gong An"("名醫公案"), and "Yi Ji Kao"("醫籍考"). The "Yi Ji Kao" is 80 volumes in length and lists about 3000 books on medicine in China before the Qing Dao Guang(道光), and under each title are the origin, number of volumes, state of existence, and, if possible, the preface, Ba Yu(跋語) and biography of the author. The younger sibling of Yuan Yin(元胤 1789-1827), Yuan Jian(元堅 1795-1857) expounded ancient writings at the Yi Xue Guan only after he reached middle age, was chosen for the Ao Yi Shi(奧醫師) and later became a Fa Yan(法眼), Fa Yin(法印) and Yu Chi(樂匙). He left about 15 texts, including "Su Wen Shao Shi"("素間紹識"), "Yi Xin Fang"("醫心方"), published in school, "Za Bing Guang Yao"("雜病廣要"), "Shang Han Guang Yao"(傷寒廣要), and "Zhen Fu Yao Jue"("該腹要訣"). On the Taki family's founding and working of the Yi Xue Guan Yasuka Doumei(失數道明) said they were "the people who took the initiative in Edo era kampo medicine" and evaluated their deeds in the fields of 'research of ancient text', 'the founding of Ji Shou Guan and medical education', 'publication business', 'writing of medical text'. 5. The doctors of the 'Kao Zheng Pai ' based their operations on the Edo Yi Xue Guan, and made groups with people with similar ideas to them, making a relationship 'net'. For example the three families of Duo Ji(多紀), Tang Chuan(湯川) and Xi Duo Cun(喜多村) married and adopted with and from each other and made prefaces and epitaphs for each other. Thus, the Taki family, the state science of the Makufu, the tendency of thinking, one's own interests and glory, one's own knowledge, the need of the society all played a role in the development of kampo medicine in the 18th and 19th century.

  • PDF

A Study on The 'Kao Zheng Pai'(考證派) of The Traditional Medicine of Japan (일본 '고증파(考證派)' 의학에 관한 연구)

  • Park, Hyun-Kuk;Kim, Ki-Wook
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.10
    • /
    • pp.1-40
    • /
    • 2008
  • 1.The 'Kao Zheng Pai'(考證派) comes from the 'Zhe Zhong Pai(折衷派)' and is a school that is influenced by the confucianism of the Qing dynasty. In Japan Inoue Kinga(井上金峨), Yoshida Koton(古田篁墩 $1745{\sim}1798$) became central members, and the rise of the methodology of historical research(考證學) influenced the members of the 'Zhe Zhong Pai', and the trend of historical research changed from confucianism to medicine, making a school of medicine based on the study of texts and proving that the classics were right. 2. Based on the function of 'Nei Qu Li'(內驅力) the 'Kao Zheng Pai', in the spirit of 'use confucianism as the base', researched letters, meanings and historical origins. Because they were influenced by the methodology of historical research(考證學) of the Qing era, they valued the evidential research of classic texts, and there was even one branch that did only historical research, the 'Rue Xue Kao Zheng Pai'(儒學考證派). Also, the 'Yi Xue Kao Zheng Pai'(醫學考證派) appeared by the influence of Yoshida Kouton and Kariya Ekisai(狩谷掖齋). 3. In the 'Kao Zheng Pai(考證派)'s theories and views the 'Yi Xue Kao Zheng Pai' did not look at medical scriptures like the "Huang Di Nei Jing"("黃帝內經") and did not do research on 'medical' related areas like acupuncture, the meridian and medicinal herbs. Since they were doctors that used medicine, they naturally were based on 'formulas'(方劑) and since their thoughts were based on the historical ideologies, they valued the "Shang Han Ja Bing Lun" which was revered as the 'ancestor of all formulas'(衆方之祖). 4. The lives of the important doctors of the 'Kao Zheng Pai' Meguro Dotaku(目黑道琢) Yamada Seichin(山田正珍), Yamada Kyoko(山田業廣), Mori Ritsi(森立之) Kitamura Naohara(喜多村直寬) are as follows. 1) Meguro Dotaku(目黑道琢 $1739{\sim}1798$) was born of lowly descent but, using his intelligence and knowledge, became a professor as a Shi Jing Yi(市井醫) and as a professor for 34 years at Ji Shou Guan(躋壽館) mastered the "Huang Di Nei Jing" after giving over 300 lectures. Since his pupil, Isawara Ken(伊澤蘭軒) taught the Lan Men Wu Zhe(蘭門五哲) and Shibue Chusai(澀江抽齋), Mori Ritsi(森立之), Okanishi Gentei(岡西玄亭), Kiyokawa Gendoh(淸川玄道) and Yamada Kyoko(山田業廣), Meguro Dotaku is considered the founder of the 'Yi Xue Kao Zheng Pai'. 2) The family of Yamada Seichin(山田正珍 $1749{\sim}1787$) had been medical officials in the Makufu(幕府) and the many books that his ancestors had left were the base of his art. Seichin learned from Shan Ben Bei Shan(山本北山), a 'Zhe Zhong Pai' scholar, and put his efforts into learning, teaching and researching the "Shang Han Lun"("傷寒論"). Living in a time between 'Gu Fang Pai'(古方派) member Nakanishi Goretada(中西惟忠) and 'Kao Zheng Pai' member Taki Motohiro(多紀元簡), he wrote 11 books, 2 of which express his thoughts and research clearly, the "Shang Han Lun Ji Cheng"("傷寒論集成") and "Shang Han Kao"("傷寒考"). His comparison of the 'six meridians'(3 yin, 3 yang) between the "Shang Han Lun" and the "Su Wen Re Lun"("素問 熱論") and his acknowledgement of the need and rationality of the concept of Yin-Yang and Deficient-Replete distinguishes him from the other 'Gu Fang Pai'. Also, his dissertation of the need for the concept doesn't use the theories of latter schools but uses the theory of the "Shang Han Lun" itself. He even researched the historical parts, such as terms like 'Shen Nong Chang Bai Cao'(神農嘗百草) and 'Cheng Qi Tang'(承氣湯). 3) The ancestor of Yamada Kyoko(山田業廣) was a court physician, and learned confucianism from Kao Zheng Pai's Ashikawa Genan(朝川善庵) and medicine from Isawa Ranken(伊澤蘭軒) and Taki Motokata(多紀元堅), and the secret to smallpox from Ikeda Keisui(池田京水). He later became a lecturer at the Edo Yi Xue Guan(醫學館) and was invited as the director to the Ji Zhong(濟衆) hospital. He also became the first owner of the Wen Zhi She(溫知社), whose main purpose was the revival of kampo, and launched the monthly magazine Wen Zi Yi Tan(溫知醫談). He also diagnosed and prescribed for the prince Ming Gong(明宮). His works include the "Jing Fang Bian"("經方辨"), "Shang Han Lun Si Ci"("傷寒論釋詞"), "Huang Zhao Zhu Jia Zhi Yan Ji Yao"("皇朝諸家治驗集要") and "Shang Han Ja Bing Lun Lei Juan"("傷寒雜病論類纂"). of these, the "Jing Fang Bian"("經方辨") states that the Shi Gao(石膏) used in the "Shang Han Lun" had three meanings-Fa Biao(發表), Qing Re(淸熱), Zi Yin(滋陰)-which were from 'symptoms', and first deducted the effects and then told of the reason. Another book, the "Jiu Zhe Tang Du Shu Ji"("九折堂讀書記") researched and translated the difficult parts of the "Shang Han Lun", "Jin Qui Yao Lue"("金匱要略"), "Qian Jin Fang"("千金方"), and "Wai Tai Mi Yao"("外臺秘要"). He usually analyzed the 'symptoms' of diseases but the composition, measurement, processing and application of medicine were all in the spectrum of 'analystic research' and 'researching analysis'. 4) The ancestors of Mori Ritsi(森立之 $1807{\sim}1885$) were warriors but he became a doctor by the will of his mother, and he learned from Shibue Chosai(澁江抽齋) and Isawaran Ken(伊澤蘭軒) and later became a pupil of Shou Gu Yi Zhai(狩谷掖齋), a historical research scholar. He then became a lecturer of medical herbs at the Yi Xue Guan, and later participated in the proofreading of "Yi Xin Fang"("醫心方") and with Chosai compiled the "Jing Ji Fang Gu Zhi"("經籍訪古志"). He visited the Chinese scholar Yang Shou Jing(楊守敬) in 1881 and exchanged books and ideas. Of his works, there are the collections(輯複本) of "Shen Nong Ben Cao Jing"("神農本草經") and "You Xiang Yi Hwa"("遊相醫話") and the records, notes, poems, and diaries such as "Zhi Yuan Man Lu"("枳園漫錄") and "Zhi Yuan Sui Bi"(枳園隨筆) that were not published. His thoughts were that in restoring the "Shen Nong Ben Cao Jing", "the herb to the doctor is like the "Shuo Wen Jie Zi"(說文解字) to the scholar", and he tried to restore the ancient herbal text using knowledge of medicine and investigation(考據), Also with Chosai he compiled the "Jing Ji Fang Gu Zhi"("經籍訪古志") using knowledge of ancient text. Ritzi left works on pure investigation, paid much attention to social problems, and through 12 years of poverty treated all people and animals in all branches of medicine, so he is called a 'half confucianist half doctor'(半儒半醫). 5) Kitamurana Ohira(喜多村直寬, $1804{\sim}1876$) learned scriptures and ancient texts from confucian scholar Asaka Gonsai(安積艮齋), and learned medicine from his father Huai Yaun(槐園), He became a teacher in the Yi Xue Guan in his middle ages, and to repay his country, he printed 266 volumes of "Yi Fang Lei Ju"("醫方類聚") and 1000 volumes of "Tai Ping Yu Lan"("太平禦覽") and devoted it to his country to be spread. His works are about 40 volumes including "Jin Qui Yao Lue Shu Yi"("金匱要略疏義") and "Lao Yi Zhi Yan"(老醫巵言) but most of them are researches on the "Shang Han Za Bing Lun". In his "Shang Han Lun Shu Yi"("傷寒論疏義") he shows the concept of the six meridians through the Yin-Yang, Superficial or internal, cold or hot, deficient or replete state of diseases, but did not match the names with the six meridians of the meridian theory, and this has something in common with the research based on the confucianism of Song(宋儒). In clinical treatment he was positive toward old and new methods and also the experience of civilians, but was negative toward western medicine. 6) The ancestor of the Taki family Tanbano Yasuyori(丹波康賴 $912{\sim}955$) became a Yi Bo Shi(醫博士) by his medical skills and compiled the "Yi Xin Fang"("醫心方"). His first son Tanbano Shigeaki(丹波重明) inherited the Shi Yao Yuan(施藥院) and the third son Tanbano Masatada(丹波雅忠) inherited the Dian You Tou(典藥頭). Masatada's descendents succeeded him for 25 generations until the family name was changed to Jin Bao(金保) and five generations later it was changed again to Duo Ji(多紀). The research scholar Taki Motohiro was in the third generation after the last name was changed to Taki, and his family kept an important part in the line of medical officers in Japan. Taki Motohiro(多紀元簡 $1755{\sim}1810$) was a teacher in the Yi Xue Guan where his father was residing, and became the physician for the general Jia Qi(家齊). He had a short temper and was not good at getting on in the world, and went against the will of the king and was banished from Ao Yi Shi(奧醫師). His most famous works, the "Shang Han Lun Ji Yi"("傷寒論輯義") and "Jin Qui Yao Lue Ji Yi"("金匱要略輯義") are the work of 20 years of collecting the theories of many schools and discussing, and is one of the most famous books on the "Shang Han Lun" in Japan. "Yi Sheng"("醫勝") is a collection of essays on research. Also there are the "Su Wen Shi"(素問識), "Ling Shu Shi"("靈樞識"), and the "Guan Ju Fang Yao Bu"("觀聚方要補"). Taki Motohiro(多紀元簡)'s position was succeeded by his third son Yuan Yin(元胤 $1789{\sim}1827$), and his works include works of research such as "Nan Jing Shu Jeng"(難經疏證), "Ti Ya"("體雅"), "Yao Ya"("藥雅"), "Ji Ya"(疾雅), "Ming Yi Gong An"(名醫公案), and "Yi Ji Kao"(醫籍考). The "Yi Ji Kao" is 80 volumes in length and lists about 3000 books on medicine in China before the Qing Dao Guang(道光), and under each title are the origin, number of volumes, state of existence, and, if possible, the preface, Ba Yu(跋語) and biography of the author. The younger sibling of Yuan Yin(元胤 $1789{\sim}1827$), Yuan Jian(元堅 $1795{\sim}1857$) expounded ancient writings at the Yi Xue Guan only after he reached middle age, was chosen for the Ao Yi Shi(奧醫師) and later became a Fa Yan(法眼), Fa Yin(法印) and Yu Chi(禦匙). He left about 15 texts, including "Su Wen Shao Shi"("素問紹識"), "Yi Xin Fang"("醫心方"), published in school, "Za Bing Guang Yao"("雜病廣要"), "Shang Han Guang Yao"("傷寒廣要"), and "Zhen Fu Yao Jue"("診腹要訣"). On the Taki family's founding and working of the Yi Xue Guan Yasuka Doumei(矢數道明) said they were "the people who took the initiative in Edo era kampo medicine" and evaluated their deeds in the fields of 'research of ancient text', the founding of Ji Shou Guan(躋壽館) and medical education', 'publication business', 'writing of medical text'. 5. The doctors of the 'Kao Zheng Pai' based their operations on the Edo Yi Xue Guan, and made groups with people with similar ideas to them, making a relationship 'net'. For example the three families of Duo Ji(多紀), Tang Chuan(湯川) and Xi Duo Cun(喜多村) married and adopted with and from each other and made prefaces and epitaphs for each other. Thus, the Taki family, the state science of the Makufu, the tendency of thinking, one's own interests and glory, one's own knowledge, the need of the society all played a role in the development of kampo medicine in the 18th and 19th century.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF