• 제목/요약/키워드: Measurement management

검색결과 3,947건 처리시간 0.032초

The effective quality assurance for image guided device using the AMC G-Box (AMC G-Box를 이용한 영상유도장치의 효율적인 정도관리)

  • Kim, Chong Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • 제26권2호
    • /
    • pp.199-206
    • /
    • 2014
  • Purpose : According to the rapid increase recently in image-guided radiation therapy, It is necessary to control of the image guidance system completely. In particular for the main subject to the accuracy of image guided radiation therapy device to be done essentially the quality assurance. We made efficient phantom in AMC for the management of the accurate and efficient. Materials and Methods : By setting up of five very important as a quality assurance inventory of the Image guidance system, we made (AMC G-Box) phantom for quality assurance efficient and accurate. Quality assurance list were the Iso-center align, the real measurement, the center align of four direction, the accuracy of table movement and the reproducibility of Hounsfield Unit. The rectangular phantom; acrylic with a thickness of 1 cm to $10cm{\time}10cm{\time}10cm$ was inserted the three materials with different densities respectively for measure the CBCT HU. The phantom was to perform a check of consistency centered by creating a marker that indicates the position of the center fixed. By performing the quality assurance using the phantom of existing, comparing the resulting value to the different resulting value using the AMC G-Box, experiment was analyzed time and problems. Therapy equipment was used Varian device. It was measured twice at 1-week intervals. Results : When implemented quality assurance of an image guidance system using AMC G-Box and a phantom existing has been completed, the quality assurance result is similar in $0.2mm{\pm}0.1$. In the case of the conventional method, it was 45 minutes at 30 minutes. When using AMC G-Box, it takes 20 minutes 15 minutes, and declined to 50% of the time. Conclusion : The consistency and accurate of image guidance system tend to decline using device. Therefore, We need to perform thoroughly on the quality assurance related. It needs to be checked daily to consistency check especially. When using the AMC G-Box, It is possible to enhance the accuracy of the patient care and equipment efficiently performing accurate quality assurance.

The Necessity and Requirement of Trial Lens Set Standardization (검안렌즈 표준화의 필요성과 규격에 관한 연구)

  • Park, Sang-Yeul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • 제11권3호
    • /
    • pp.217-223
    • /
    • 2006
  • The purpose of this study is to provide improvements and standards of trial lens, in a situation that there is a lack of standards of trial lens set that have been used for self-conscious refraction test after helm refraction test at about 5,000 opticians, ophthalmologic clinics and hospitals, and contact-lens shops, that there is a lot of discrepancies between refraction specified and the actual power, and that there is no regulation of optical tolerance error. For the study, opticians who have used Trial lens set were asked to participate in a questionnaire survey through continuing education, and divided into those who have used domestic lens and those who have used imported lens, 5 opticians each for less than 5 years, 5 to 10 years, more than 10 years. The measurement of both refraction specified and the actual diopter was compared to Japan Industrial Standards(JIS T4402). As a result of comparative analysis, more than 80% of respondents have had reliability on the refraction of trial lens they had used, indicating that they have never measured the refraction specified and the actual diopter after buying them. Besides, Korean Industrial Standards(KS P4402) has been imperfect in diopter range since it was legislated in 1979. More than 95% of respondents have been unsatisfied with optometry. Also, it has indicated that refraction error is more frequent in long-term-used trial lens. The conclusion is that it is necessary to standardize trial lens set and that it is required to add lens to lens set provided under KS P4402. Moreover, it is necessary to have supervisory agency for a standardization of trial lens. I hope that both domestic lens and imported lens, as in German and Japan, will be tested to find whether they meet optical tolerance error and standard trial lens will be distributed. Good optic inspection is required for the improvement and management of eye health and optical function, and the same standard trial lens set should be used. whoever is tested. Also, I hope that trial lens set will be specified within standards and tolerance error.

  • PDF

A Study on 3D Scan Technology for Find Archetype of Youngbeokji in Seongnagwon Garden (성락원 영벽지의 원형 파악을 위한 3D 스캔기술 연구)

  • Lee, Won-Ho;Kim, Dong-Hyun;Kim, Jae-Ung;Park, Dong-Jin
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • 제31권3호
    • /
    • pp.95-105
    • /
    • 2013
  • This study on circular identifying purposes was performed of Youngbeokji space located in Seongnagwon(Scenic Sites No.35). Through the data acquisition of 3D high precision, such as the surrounding terrain of the Youngbeokji. The results of this study is summarized like the following. First, the purpose of the stone structures and structure within the Youngbeokji search is an important clue to find that earlier era will be a prototype. 3D scan method of enforcement is searching the whole structure, including the surrounding terrain and having the easy way. Second, the measurement results are as follows. Department of bedrock surveyed from South to North was measured by 7,665mm. From East to West was measured at 7,326mm. The size of the stone structures, $1,665mm{\times}1,721mm$ in the form of a square. Its interior has a diameter of 1, 664mm of hemispherical form. In the lower portion of the rock masses in the South to the North, has fallen out of the $1,006mm{\times}328mm$ scale traces were discovered. Third, the Youngbeokji recorded in the internal terrain Multiresolution approach. After working with the scanner and scan using the scan data, broadband, to merge. Polygon Data conversion to process was conducted and mash as fine scan data are converted to process data. High resolution photos obtained through the creation of 3D terrain data overlap and the final result. Fourthly, as a result of this action, stone structure West of the waterway back outgoing times oil was confirmed. Bangjiwondo is estimated to be seokji of structure hydroponic facility confirmed will artificially carved in the bedrock. As a result of this and the previous situation of the 1960s could compare data was created. This study provides 3D precision ordnance through the acquisition of the data. Excavations at the circle was able to preserve in perpetuity as digital data. In the future, this data is welcome to take a wide variety of professionals. This is the purpose of this is to establish foundations and conservation management measures will be used. In addition, The new ease of how future research and 3D scan unveiled in the garden has been used in the study expect.

Comparison of Cognitive Loads between Koreans and Foreigners in the Reading Process

  • Im, Jung Nam;Min, Seung Nam;Cho, Sung Moon
    • Journal of the Ergonomics Society of Korea
    • /
    • 제35권4호
    • /
    • pp.293-305
    • /
    • 2016
  • Objective: This study aims to measure cognitive load levels by analyzing the EEG of Koreans and foreigners, when they read a Korean text with care selected by level from the grammar and vocabulary aspects, and compare the cognitive load levels through quantitative values. The study results can be utilized as basic data for more scientific approach, when Korean texts or books are developed, and an evaluation method is built, when the foreigners encounter them for learning or an assignment. Background: Based on 2014, the number of the foreign students studying in Korea was 84,801, and they increase annually. Most of them are from Asian region, and they come to Korea to enter a university or a graduate school in Korea. Because those foreign students aim to learn within Universities in Korea, they receive Korean education from their preparation for study in Korea. To enter a university in Korea, they must acquire grade 4 or higher level in the Test of Proficiency in Korean (TOPIK), or they need to complete a certain educational program at each university's affiliated language institution. In such a program, the learners of the Korean language receive Korean education based on texts, except speaking domain, and the comprehension of texts can determine their academic achievements in studying after they enter their desired schools (Jeon, 2004). However, many foreigners, who finish a language course for the short-term, and need to start university study, cannot properly catch up with university classes requiring expertise with the vocabulary and grammar levels learned during the language course. Therefore, reading education, centered on a strategy to understand university textbooks regarded as top level reading texts to the foreigners, is necessary (Kim and Shin, 2015). This study carried out an experiment from a perspective that quantitative data on the readers of the main player of reading education and teaching materials need to be secured to back up the need for reading education for university study learners, and scientifically approach educational design. Namely, this study grasped the difficulty level of reading through the measurement of cognitive loads indicated in the reading activity of each text by dividing the difficulty of a teaching material (book) into eight levels, and the main player of reading into Koreans and foreigners. Method: To identify cognitive loads indicated upon reading Korean texts with care by Koreans and foreigners, this study recruited 16 participants (eight Koreans and eight foreigners). The foreigners were limited to the language course students studying the intermediate level Korean course at university-affiliated language institutions within Seoul Metropolitan Area. To identify cognitive load, as they read a text by level selected from the Korean books (difficulty: eight levels) published by King Sejong Institute (Sejonghakdang.org), the EEG sensor was attached to the frontal love (Fz) and occipital lobe (Oz). After the experiment, this study carried out a questionnaire survey to measure subjective evaluation, and identified the comprehension and difficulty on grammar and words. To find out the effects on schema that may affect text comprehension, this study controlled the Korean texts, and measured EEG and subjective satisfaction. Results: To identify brain's cognitive load, beta band was extracted. As a result, interactions (Fz: p =0.48; Oz: p =0.00) were revealed according to Koreans and foreigners, and difficulty of the text. The cognitive loads of Koreans, the readers whose mother tongue is Korean, were lower in reading Korean texts than those of the foreigners, and the foreigners' cognitive loads became higher gradually according to the difficulty of the texts. From the text four, which is intermediate level in difficulty, remarkable differences started to appear in comparison of the Koreans and foreigners in the beginner's level text. In the subjective evaluation, interactions were revealed according to the Koreans and foreigners and text difficulty (p =0.00), and satisfaction was lower, as the difficulty of the text became higher. Conclusion: When there was background knowledge in reading, namely schema was formed, the comprehension and satisfaction of the texts were higher, although higher levels of vocabulary and grammar were included in the texts than those of the readers. In the case of a text in which the difficulty of grammar was felt high in the subjective evaluation, foreigners' cognitive loads were also high, which shows the result of the loads' going up higher in proportion to the increase of difficulty. This means that the grammar factor functions as a stress factor to the foreigners' reading comprehension. Application: This study quantitatively evaluated the cognitive loads of Koreans and foreigners through EEG, based on readers and the text difficulty, when they read Korean texts. The results of this study can be used for making Korean teaching materials or Korean education content and topic selection for foreigners. If research scope is expanded to reading process using an eye-tracker, the reading education program and evaluation method for foreigners can be developed on the basis of quantitative values.

Characteristics Regarding Ion Index by Geomorphic Structure -About Larix kaempferi of Wolaksan National Park (지형구조 차이에 따른 이온지수 특성 -월악산국립공원 일본잎갈나무림을 대상으로)

  • Kim, Jeong-Ho;Lee, Sang-Hoon;Kim, Won-Tae;Yoon, Yong-Han
    • Korean Journal of Environment and Ecology
    • /
    • 제32권5호
    • /
    • pp.486-496
    • /
    • 2018
  • In this study, we have selected Larix kaempferi as a study area in Woraksan National Park for understanding the ion index according to the difference of topography in national parks. We measured the weather and ion at two fixed points, ridge and valley, where the Larix kaempferi dominates in the same ecological structure in Woraksan National Park. The weather measurement results showed the average, maximum, and minimum temperatures of $28.22^{\circ}C$, $29.9^{\circ}C$, and $26.4^{\circ}C$, respectively at the ridge. The average, maximum, and minimum temperatures at the valley were $27.08^{\circ}C$, $27.8^{\circ}C$, and $25.5^{\circ}C$, respectively. The average, maximum, and minimum relatively humidities at the ridge were 67.02%, 75.25%, and 61.95%, respectively. he average, maximum, and minimum relatively humidities at the valley were 69.74%, 76.8%, and 63.75%, respectively. The average, maximum, and minimum amounts of positive ions generated in the ridge was $698.40{\pm}59.80ea/cm^3$, $885.88ea/cm^3$, and $597.88ea/cm^3$, respectively. The average, maximum, and minimum amounts of negative ions generated in the ridge were $736.07{\pm}83.89ea/cm^3$, $934.53ea/cm^3$, and $599.32ea/cm^3$, respectively. The ion index is calculated to be 1.06. The average, maximum, and minimum amounts of positive ions generated in the valley were $1,732.49{\pm}354.08ea/cm^3$, $2,652.10ea/cm^3$, and $1,110.92ea/cm^3$, respectively. The average, maximum, and minimum amounts of negative ions generated in the valley were $1,990.47{\pm}433.57ea/cm^3$, $3,126.75ea/cm^3$, and the minimum value was $1,352.17ea/cm^3$. The ion index is calculated to be 1.16. The difference in the amount of negative ions generated in ridge and valley was $1089.26ea/cm^3$, and the difference of the calculated ion index between the ridge portion and the valley portion was 0.10. The results of this study were provided as the reference weather data of national parks for health management.

Effect of Short Term Treatment with Different Dosage of Inhaled Flucatisone Propionate on Basal Cortisol Concentration (단기간 Fluticasone Propionate 투여 용량에 따른 가저 코르티솔 농도의 변화)

  • Kim, Hyun-Jung;Kim, Hyoung-Sik;Lee, Hong;Moon, Sung-Gi;Lim, Seok-Tae;Park, Ji-Hyun;Lee, Heung-Bum;Lee, Yong-Chul;Rhee, Yang-Keun
    • Tuberculosis and Respiratory Diseases
    • /
    • 제44권5호
    • /
    • pp.1063-1071
    • /
    • 1997
  • Backgroung : The efficacy of oral corticosteroids in the treatment of chronic asthma is undisputed, but their long-term use is associated with adverse side-effects, including supression of the hypothalamic-pituitary adrenal axis function, osteoporosis, weight gain, hypertension and impaired glucose tolerance. The introduction of inhaled corticosteroids in the early 1970's represented a significant therapeutic advance in the management of asthma, since these compounds combined high topical potency with low systemic activity. Fluticasone propionate is a new topically active synthetic glucocorticosteroid that combinds a high degree of efficacy with negligible systemic bioavailability. This study was perfomed to determine the effect of inhaled fluticasone propionate on the adreocortical supression in patients with bronchial asthma or chronic obstructive pulmonary disease. Method : The adrenocortical function was assessed by measurement of plasma cortisol concentration at 8 o'clock in morning and free cortisol in 24 hour urine collection at interval. Absolutely, no steroid was taken during pretreatment period of 10days. There after each subject inhaled fluticasone aerosol, in daily doses of 500 or 1000micrograms for 12days. The dose was delivered by metered dose inhaler(MDI). Results : The serum cortisol and 24hour urinary free cortisol were not decreased during the treatment period in patients with inhaled fluticasone propionate in daily doses of 500 micrograms. In contrast, serum cortisol was significantly decreased on 9th and 12th day(p less than 0.05). And, 24hour urinary free cortisol was also significantly decreased on 3rd and 12th day of treatement period(p less than 0.05) in patients with inhaled fluticasone in daily doses of 1000 micrograms. Conclusion : These results suggested that endogenous cortisol secretion was not supressed after short-term inhalation of fluticasone in daily dose of 500 micrograms, but in daily dose of 1000 micrograms, the endogenous cortisol secretion was supressed.

  • PDF

Establishment of Biotin Analysis by LC-MS/MS Method in Infant Milk Formulas (LC-MS/MS를 이용한 조제유류 중 비오틴 함량 분석법 연구)

  • Shin, Yong Woon;Lee, Hwa Jung;Ham, Hyeon Suk;Shin, Sung Cheol;Kang, Yoon Jung;Hwang, Kyung Mi;Kwon, Yong Kwan;Seo, Il Won;Oh, Jae Myoung;Koo, Yong Eui
    • Journal of Food Hygiene and Safety
    • /
    • 제31권5호
    • /
    • pp.327-334
    • /
    • 2016
  • This study was conducted to establish the standard method for the contents of biotin in milk formulas. To optimize the method, we compared several conditions for liquid extraction, purification and instrumental measurement using spiked samples and certified reference material (NIST SRM 1849a) as test materials. LC-MS/MS method for biotin was established using $C_{18}$ column and binary gradient 0.1% formic acid/acetonitrile, 0.1% formic acid/water mobile phase is applied for biotin. Product-ion traces at m/z 245.1 ${\rightarrow}$ 227.1, 166.1 are used for quantitative analysis of biotin. The linearity was over $R^2=0.999$ in range of $5{\sim}60{\mu}g/L$. For purification, chloroform was used as a solvent for eliminating lipids in milk formula. The linearity was over 0.999 in range of 5~60 ng/mL. The detection limit and quantification limit were 0.10, 0.31 ng/mL. The accuracy and precision of LC-MS/MS method using CRM were 103%, 2.5% respectively. Optimized methods were applied in sample analysis to verify the reliability. All the tested milk formulas were acceptable contents of biotin compared with component specification and standards for nutrition labeling. The standard operating procedures were prepared for biotin to provide experimental information and to strengthen the management of nutrient in milk formula.

Significance of Vascular Endothelial Growth Factor in Pleural Effusion (흉막수에서 Vascular Endothelial Growth Factor의 진단적 의의)

  • 김현구;조원민;류세민;조양현;심재훈;손영상;김학제;최영호
    • Journal of Chest Surgery
    • /
    • 제37권9호
    • /
    • pp.781-786
    • /
    • 2004
  • None of the currently available strategies for diagnosis and management of the pleural effusion are ideal. We tried to evaluate the validity of VEGF in differential diagnosis of the pleural effusion and find out if VEGF were correlated with the established markers. Material and Method: 35 patients with pleural effusion were divided into malignant effusion (n=10), benign effusion (n=5), infectious effusion (n=10), and pneumothorax (n=10), respectively. The pleural fluids from each group were examined for differential cell count, chemistry (glucose, protein, LDH, and ADA), and VEGF. Result: Glucose level was lower in infectious effusion compared with benign effusion (60.5$\pm$36.09 mg/dL vs. 162.0$\pm$19.80 mg/dL, p=0.011). ADA level in infectious effusion was higher compared with malignant effusion (87.9$\pm$42.62 IU/L vs. 27.7$\pm$31.04 IU/L, p=0.024). Malignant effusion (p=0.026) and infectious effusion (p=0.048) showed significantly higher level of VEGF than that of pneumothorax. VEGF level was substantially higher in malignant effusion compared with benign effusion (364.38$\pm$433.83 pg/dL vs. 53.3$\pm$22.20 pg/dL, p=NS). The pleural VEGF level did not correlate with the other markers. Conclusion: The measuring pleural VEGF may be helpful in diagnosing malignant and infectious pleural effusion that increase angiogenesis and vascular permeability, but it can not discriminate between the two. The pleural VEGF may not be correlated with the established markers. The measurement of pleural VEGF might discriminate between malignant and benign effusion.

A Study of Home Care Needs of Patients at Discharge and Effects of Home Care -Centered on Patients Discharged from a Rural General Hospilal- (퇴원환자의 가정간호요구와 가정간호사업의 효과 분석 - 일 종합병원을 중심으로)

  • Choi, Yun Soon;Kim, Dai Hyun;Storey, Margaret;Kim, Cho Ja;Kang, Kyu Sook
    • The Korean Nurse
    • /
    • 제31권4호
    • /
    • pp.77-99
    • /
    • 1992
  • The study was carried out at W. hospital, an affiliated hospital of Y university, involved a total of 163 patients who were discharged from the hospital between May 1990 und March 199J. Data collection was twice, just prior to discharge and a minimum of three months post discharge. Thirty patients who lived within a hour travel time of the hospital received home care during the three months post discharge. Nursing diagnoses and nursing interventions For these patients were analyzed in this study. The results of the study are summarized as follows : 1. Discharge needs for the subjects of the study were analyzed using Gordon's eleven Functional categories and it was found that 48.3% of the total sample had identified nursing needs. Of these, the needs most frequently identified were in the categories of sexuality, 79.3 %, health perception, 68.2 % self concept, 62.5 %, and sleep and rest 62.5 %. Looking ut j he nursing diagnosis that were made for the 30 patients receiving home care, the following diagnoses were the most frequently given; alteration in sexual pattern 79.3%, alterations in health maintenance, 72.6%, alteration in comfort, 68.0%, depression, 64.0%, noncompliance with diet therapy, 6.3.7%, alteration in self concept, 55.6%, and alteration in sleep pattern, 53%. 2. In looking at the effects of home nursing care as demonstrated by changes in the functional categories over the three month period, it was Found that of the 11 functional categories, the need level for health perception, nutrition, activity and self concept decreased slightly over the three month period. On the average sleep patterns improved, but restfulness was slightly less and bowel elimination patterns improved but satisfaction with urinary elimination was slightly less. On the other hand, role enactment, sexuality, stress management and spirituality decreased slightly. The only results that were statistically significant at the 0.05 level were improvement. in digestion and decrease in pain. No statistically significant changes were found in ability related to ADL, the total ADL Score at discharge was $19.78{\pm}8.234, and after 3 months $19.01{\pm}8.12$. Considering that a majority of the patients were over 60 years of age and that many had brain or spinal cord injuries, the fact that their ADL ability did nor deteriorate after discharge can be interpreted as related to a positive impact by the home health care nurses. Similarly there was a slight be not statistically significant decrease in the quality of life scores between the two lest times(l47.83 at discharge and 113.02 at the three month period). Again, when the chronic nature of thee problems facing these patients is considered this maintenance of quality of life can be interpreted as a positive impact by the home health care nurses. 3. One of the home care nursing activities was diagnosis. For this activity it was found that for nine functional health categories(sexuality and spirituality excepted) there were 20 nursing diagnoses. The most frequent were noncompliance, alteration in skin integrity both actual and potential, and impaired physical mobility in that order. 4. Delivery of home health care by the home health nurses included the following nursing activities; assessment, patient education, demonstration of care activities, counselling, direct care to the patient and referrals. Direct care included changing dressings, bladder irrigations, changing Foley catheters, measurement of residual urine, perineal care, position change, back care, oral hygiene, exercise and massage of motion exercises, cleansing enemas, tracheostomy suctioning and tracheostomy care, care of dentures, applications of heat and other similar nursing activities. In conclusion almost 50% of (he sample indicated a need for continued nursing care at the time of discharge and for the patients in the sample who received home care there was a slight decrease in nursing needs but while the patients had chronic and debilitation problems there was ill decrease in ADL abilities or in quality of life. Further study needs Lo be done La increase the reliability and validity of the tool that was used to measure home health care needs. It is also recommended that study by done using a randomized sampling with a control group to compare patients who receive home care with those who do not.

  • PDF

The Study of Error for Analysis in Dynamic Image from the Error of Count Rates in NaI (Tl) Scintillation Camera (NaI (Tl) 신틸레이션 카메라에서 계수율 오차에 따른 동적 영상 분석치 산출 오류에 관한 연구)

  • Oh, Joo-Young;Kang, Chun-Goo;Kim, Jung-Yul;Park, Hoon-Hee;Oh, Ki-Baek;Kim, Jae-Sam
    • Journal of radiological science and technology
    • /
    • 제36권4호
    • /
    • pp.291-297
    • /
    • 2013
  • This study is aimed to evaluate the effect of $T_{1/2}$ upon count rates in the analysis of dynamic scan using NaI (Tl) scintillation camera, and suggest a new quality control method with this effects. We producted a point source with $^{99m}TcO_4^-$ of 18.5 to 185 MBq in the 2 mL syringes, and acquired 30 frames of dynamic images with 10 to 60 seconds each using Infinia gamma camera (GE, USA). In the second experiment, 90 frames of dynamic images were acquired from 74 MBq point source by 5 gamma cameras (Infinia 2, Forte 2, Argus 1). There were not significant differences in average count rates of the sources with 18.5 to 92.5 MBq in the analysis of 10 to 60 seconds/frame with 10 seconds interval in the first experiment (p>0.05). But there were significantly low average count rates with the sources over 111 MBq activity at 60 seconds/frame (p<0.01). According to the second analysis results of linear regression by count rates of 5 gamma cameras those were acquired during 90 minutes, counting efficiency of fourth gamma camera was most low as 0.0064%, and gradient and coefficient of variation was high as 0.0042 and 0.229 each. We could not find abnormal fluctuation in $x^2$ test with count rates (p>0.02), and we could find the homogeneity of variance in Levene's F-test among the gamma cameras (p>0.05). At the correlation analysis, there was only correlation between counting efficiency and gradient as significant negative correlation (r=-0.90, p<0.05). Lastly, according to the results of calculation of $T_{1/2}$ error from change of gradient with -0.25% to +0.25%, if $T_{1/2}$ is relatively long, or gradient is high, the error increase relationally. When estimate the value of 4th camera which has highest gradient from the above mentioned result, we could not see $T_{1/2}$ error within 60 minutes at that value. In conclusion, it is necessary for the scintillation gamma camera in medical field to manage hard for the quality of radiation measurement. Especially, we found a tendency that count rate changes over time at this study, and we proved that it can effect $T_{1/2}$. And also, there is need of appropriate phantoms and the method of quality management like this study, because there are not any advice or limitation degrees for domestic medical purpose scintillation camera.