• Title/Summary/Keyword: Measurement criteria

Search Result 983, Processing Time 0.027 seconds

Development of an End-use Analysis Tool for Existing Buildings Based on Energy Billing Data (고지데이터 기반 기존 건축물의 용도별 에너지사용 현황분석 툴 개발)

  • Kong, Dong-Seok;Park, Jung-Min;Jang, Yong-Sung;Lee, Keon-Ho;Huh, Jung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.3
    • /
    • pp.128-136
    • /
    • 2015
  • Reducing the building energy consumption has become one of the most important issues. However, the current engineering and technological involvement in energy analysis has been relatively low in the existing buildings. In the existing buildings, end-use analysis must be accompanied to calculate the exact amount in energy savings and such analysis should be conducted based on the energy billing data or measurement data by calibration process. Mostly, detailed energy simulation programs have been proposed for the analysis but, it is difficult to utilize them due to realistic problems. In this paper, we developed an end-use analysis tool that have input function for energy audit data and two case studies were conducted in the real-life office buildings located in Seoul, Korea. Mean Bias Error (MBE) and Coefficient of Variation of Root-Mean- Squreaed-Error (CV(RMSE)) are used for the criteria of comparison. Each index was calculated by using monthly utility bills of electricity and gas consumption. Results showed that MBE and CV (RMSE) represented with acceptable values of -0.1% and 5.7% respectively.

Pharmacopuncture for Stroke: An Overview of Meta-Analyses (뇌졸중의 약침 치료에 대한 메타분석의 통합적 고찰)

  • Kim, Mikyung;Han, Chang-ho
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.6
    • /
    • pp.1081-1100
    • /
    • 2019
  • Objectives: This study is an overview of the meta-analysis and systematic review of randomized controlled trials investigating the clinical effectiveness and safety of pharmacopuncture for patients with stroke. Methods: Core electronic databases were searched from their inception to 21 May 2019. A measurement tool to assess systematic reviews (AMSTAR 2) was applied to screen high-quality studies. The results of these studies were summarized, and additional meta-analysis was conducted. The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) was used to evaluate the certainty of evidence. Results: Sixteen studies met eligibility criteria. Four were excluded owing to insufficiency of AMSTAR 2 or low data reliability. The finally selected 12 studies were about pharmacopuncture using either a single herb extract, such as Dengzhan xixin, Sanch, Ginkgo biloba, or Acanthopanax, or a mixture of herbs, such as Compound danshen, Shenxiong, Xingnaojing, or Mailuoning. Most of the patients were from China, with acute ischemic stroke. All the studies using a pharmacopuncture versus a non-pharmacopuncture design reported the significant superiority of pharmacopuncture on every outcome measure. On the other hand, in a few studies, pharmacopuncture was inferior to active control in improving neurological deficit. Few studies reported adverse events. Conclusions: It is difficult to apply the results of this study directly to Korea, because the level of evidence is generally low and the clinical settings and social acceptance of pharmacopuncture therapy differ in Korea and China. Further studies are warranted to confirm the domestic applicability of evidence generated in China and to create evidence that supports the domestic situation.

A Round Robin Study of Solid Content Test and Applicability Estimation of FT-IR Analysis for Chemical Admixtures (다자비교시험을 통한 화학혼화제 고형분량 시험법의 신뢰성 및 FT-IR 분석에 대한 효용성 평가)

  • Kim, Jin-Cheol;Yoo, Hyeok-Jin;Kim, Hong-Sam;Park, Ko-Eun
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.6
    • /
    • pp.695-703
    • /
    • 2015
  • Acceptance criteria for chemical admixtures of cement concrete were investigated in domestic and international specifications. The reliability was verified for solid content test method of chemical admixture examined statistical analysis by round robin test. The applicability of FT-IR spectroscopy for qualitative measurement of multi-compound chemical admixtures verified. From solid content experimental results, outlier analysed using Cochran, Grubbs and Dickson's Q test. Repeatability and reproducibility standard deviation for solid content results showed 0.25 and 0.098% respectively according to KS A ISO 5725-2 procedure, it can be confirmed reliability of test methods. FT-IR spectrum of liquefied or oven-dried chemical admixtures condition showed big differences. It is needed that the FT-IR analysis is performed on dry material. However there's no difference with the applicability of FT-IR spectroscopy for multi-compound chemical admixtures. So the utility of method analysis could not identify.

Distribution Characteristics between Line and Line for Indoor Air Pollutant Factors at Subway Stations in Seoul Area (서울지역 지하철역의 공기 중 오염인자의 노선별 분포 특성)

  • 김민영;라승훈;신도철;한규문;최금숙;정일현
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.2
    • /
    • pp.134-144
    • /
    • 1998
  • A comprehensive air quality monitoring was carried out to investigate the criteria concentration of air pollutant in indoor of subway stations of Seoul City. The samples were collected twice per year (the first and the second half of the year) at each sampling point from February to September in 1997. Sampling point of subway stations was ticket office and platform. The measurement of indoor air pollutants such as sulfur dioxide(SO$_2$), nitrogen dioxide(NO$_2$), carbon monoxide(CO), carbon dioxide(CO$_2$), total suspended particulate(TSP) was performed to determine the indoor air quality. Heavy metals(Pb, Cd, Cu, Cr, As, Hg) were also measured together with those air pollutants. The annual average concentration of CO$_2$ and TSP in subway stations were relatively high while those of heavy metals were within 10% of environmental recommended standard concentration in all stations. As results of regression analysis between line and line of air factors, the concentrations of CO, CO$_2$, TSP, Pb, Cd, Cr and Cu were highly correlated, but those of $SO_2, NO_2$ and Hg were not correlated. As results of regression analysis between ticket office and platform, the concentrations of heavy metals such as Cr and Cu were highly correlated. Results of oneway analysis of variance between the first and the second half of the year air factors also indicated that CO, CO$_2$, Cd, Cu, Hg were significant($\alpha$=0.01), respectively. The average contration of total suspended particulate(TSP) in subway line No. 1 was shown high concentration(200 $\mu g/m^3\cdot$ day) level.

  • PDF

Daoyin Exercise Therapy for Stroke : A Systematic Review (뇌졸중에 대한 도인 운동요법의 효과: 체계적 문헌 고찰)

  • Lee, Sang-Hyun;Shin, Byung-Cheul;Hwang, Eui-Hyoung;Heo, In;Park, Sun-Young;Hwang, Man-Suk
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.14 no.2
    • /
    • pp.29-42
    • /
    • 2019
  • Objectives : This study aimed to review the effects of Daoyin exercise on stroke patients in clinical studies. Methods : In this study, we reviewed 11 electronic databases (CAJ, EMBASE, Cochrane Library, Web of Science, Pubmed, RISS, Dbpia, NDSL, KISTI, KISS, KMBASE) on October 27, 2019. We included only randomized controlled trials (RCTs) which evaluated the effect of Daoyin exercise on stroke patients. The methodological quality of the included studies was checked using the Cochrane risk of bias tool. Results : After screening the papers, eleven RCTs fulfilled the inclusion criteria. The results of the meta-analysis showed that Daoyin exercise improves the measurement value on the Fugl-Meyer Assessment, Modified Barthel Index and National Institutes of Health Stroke Scale in stroke patients. Conclusions : We concluded that Daoyin exercise has therapeutic effects in functional recovery and in enhancing the independence of daily living activities for stroke patients. However, the quality of the original articles was low and the number of papers included were few. Thus, to confirm these results, further well-designed RCTs should be conducted.

Practical Implementation of Patient-Specific Quality Assurance for Small and Multiple Brain Tumors in CyberKnife with Fixed Collimators

  • Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.53-58
    • /
    • 2018
  • This paper evaluates patient-specific quality assurance (PSQA) in the treatment of small and multiple tumors by the CyberKnife system with fixed collimators, using an ion chamber and EBT3 films. We selected 49 patients with single or multiple brain tumors, and the treatment plans include one to four targets with total volumes ranging from 0.12 cc to 3.74 cc. All PSQA deliveries were performed with a stereotactic dose verification phantom. The A16 microchamber (Standard Imaging, WI, USA) and Gafchromic EBT3 film (Ashland ISP Advanced Materials, NJ, USA) were inserted into the phantom to measure the point dose of the target and the dose distribution, respectively. The film was scanned 1 hr after irradiation by a film digitizer scanner and analyzed using RIT software (Radiological Imaging Technology, CO, USA). The acceptance criteria was <5% for the point dose measurement and >90% gamma passing rate using 3%/3 mm and relative dose difference, respectively. The point dose errors between the calculated and measured dose by the ion chamber were in the range of -17.5% to 8.03%. The mean point dose differences for 5 mm, 7.5 mm, and 10 mm fixed cone size was -11.1%, -4.1%, and -1.5%, respectively. The mean gamma passing rates for all cases was 96.1%. Although the maximum dose distribution of multiple targets was not shown in the film, gamma distribution showed that dose verification for multiple tumors can be performed. The use of the microchamber and EBT3 film made it possible to verify the dosimetric and mechanical accuracy of small and multiple targets. In particular, the correction factors should be applied to small fixed collimators less than 10 mm.

Estimation of Genetic Improvement Based on the Breeding Values of Growth Traits of the Abalone Haliotis discus hannai (육종가 기반 북방전복(Haliotis discus hannai) 성장형질의 유전적 개량량 추정)

  • Park, Jong-Won;Park, Choul-Ji;Lee, Dain;Jung, Hyo Sun;Kim, Hyejin;Kim, Julan;Kim, Woo-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.4
    • /
    • pp.544-550
    • /
    • 2020
  • This study was conducted to estimate the genetic improvements by selection criteria using the genetic parameters and breeding values for population of abalone Haliotis discus hannai. Genetic parameters and breeding values were estimated using all measurement data of growth traits (shell length, shell width and total weight) at 18 and 30 months old after artificial fertilization for 3,029 individuals produced in April 2014. Growth traits all exhibited moderate heritability (0.253-0.354). So it is considered that family selection will be more advantageous than individual selection. It was found that a higher genetic improvement could be expected when selecting the top 10% based on the breeding values of total weight rather than other traits. In particular, a higher genetic improvement could be expected when selecting the top 10% at 30 months old than 18 months old after artificial fertilization. This seems to be because the selection differential and heritability were higher at the 30 months old. Therefore, by estimating genetic parameters and breeding values of a population for production of the next generations by stage of growth, if they are used properly in selection and mating according to the improvement direction, it is considered that more breeding effects can be expected.

Effect of Under and Over Refractive Correction on Visual Acuity Performance using Two Different Charts

  • Chen, Ai-Hong;Shah, Siti Salwa Mohamad;Rosli, Saiful Azlan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.291-295
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the effect of under and over refractive correction on visual acuity performance and the variation of the visual performance measurement using two different visual acuity charts. Methods: Ten young adults, aged between 19 and 25 years old, were recruited. Inclusion criteria: no history of ocular injury or pathology with a best-corrected visual acuity of 6/6 on dominant eye. The over and under refractive corrections were induced using minus and plus spherical ophthalmic lenses in 0.50 D steps up to 3.00 D; as well as using three axis orientations of cylindrical ophthalmic lenses ($45^{\circ}$, $90^{\circ}$ and $180^{\circ}$) in 0.50 D steps. The variation of visual acuity performance measurements was investigated using Bailey-Lovie LogMAR chart and Landolt C chart. Results: The visual acuity changes with lenses were significantly different between two charts [F = 49.15, p < 0.05 with plus spherical ophthalmic lenses and F = 174.38, p < 0.05 with minus spherical ophthalmic lenses]. The visual acuity changes with three different cylindrical axis showed no significant difference between Bailey-Lovie LogMAR chart [F = 2.35, p > 0.05] and Landolt C chart [F = 3.12, p = 0.05]. Conclusions: The over and under refractive correction affected the visual acuity performance differently. The Landolt C chart and Bailey-Lovie LogMAR chart demonstrated variation in measurements.

A Study on Durability Variation of Concrete due to Water Content Changes (콘크리트 내 수량증감에 의한 내구 품질 변동에 관한 연구)

  • Woo, Young-Je;Ryu, Hwa-Sung;Jung, Sang-Hwa;Kwon, Ki-Jun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.2 s.25
    • /
    • pp.1-6
    • /
    • 2007
  • When the water content within concrete swells, diverse problems occur such as drop in durability. Due to this reason, a change is being managed in the unit water contents by using electric capacity measurements, high frequency heating methods, and unit-volume mass measurements, which are methods of measuring the unit water contents. Particularly, Japan is prescribing the guideline of management on a change in unit water content unit quantity $({\pm}10,\;15,\;20kg//m^3,\;etc.)$. However, the guideline of Japan dose not consider a fall in durability, and is decided on the value of pass-fail criteria by random fabrication errors and measurement errors. Consequently, this study was aimed to investigate the influence of a change In water content within concrete due to an addend caused by management error and to an artificial addend, upon drop in durability.

A Study on the Improvement Plans of Maintenance Monitoring in Tunnel Structure (터널구조물 유지관리계측의 개선방안 연구)

  • Woo, Jong-Tae
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.10-20
    • /
    • 2020
  • Purpose: Analyze the results of on-site inspection of the tunnel structure maintenance management monitoring and suggest improvement plans. Method: We investigate and analyze the problems of various items on maintenance monitoring of tunnel structure of 14 subway lines of Seoul subway in downtown area. Result: The maintenance monitoring items, measurement quantity and installation location are classified into open tunnel and excavation tunnel and improvement plans are suggested respectively. Various durability criteria of the measuring instruments were examined, and durability confirmation method suggested improvement measures such as approval, inspection, inspection and testing, calibration of monitoring sensors. Conclusion: Applying the improvement measures of the tunnel structure maintenance monitoring to the construction site will increase the efficiency of the maintenance monitoring and contribute to the development of construction monitoring technology.