Browse > Article
http://dx.doi.org/10.15683/kosdi.2020.3.31.010

A Study on the Improvement Plans of Maintenance Monitoring in Tunnel Structure  

Woo, Jong-Tae (Department of Construction and Environmental System, Kyungbok University)
Publication Information
Journal of the Society of Disaster Information / v.16, no.1, 2020 , pp. 10-20 More about this Journal
Abstract
Purpose: Analyze the results of on-site inspection of the tunnel structure maintenance management monitoring and suggest improvement plans. Method: We investigate and analyze the problems of various items on maintenance monitoring of tunnel structure of 14 subway lines of Seoul subway in downtown area. Result: The maintenance monitoring items, measurement quantity and installation location are classified into open tunnel and excavation tunnel and improvement plans are suggested respectively. Various durability criteria of the measuring instruments were examined, and durability confirmation method suggested improvement measures such as approval, inspection, inspection and testing, calibration of monitoring sensors. Conclusion: Applying the improvement measures of the tunnel structure maintenance monitoring to the construction site will increase the efficiency of the maintenance monitoring and contribute to the development of construction monitoring technology.
Keywords
Tunnel Structure; Maintenance Monitoring; Period of Durability; How to Check Durability;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 Woo, J.T. (2019). "A Study on the Cause and Improvement Plans of Construction Monitoring Sensors Decline in Durability." Journal of Korea Society of Disaster Information, Vol. 15, No. 1, pp. 28-38.   DOI
2 Back, K.H., Oh, Y.S., Kim, Y.J., Kim, Y.G. (2002). "A study on the efficient plan of maintenance monitoring for tunnel." Journal of Korean Tunnelling and Underground Space Association, Vol. 4, No. 4, pp. 355-369.
3 Woo, J.T., Lee, R.C. (2017). Theory and practice of construction monitoring-underground construction facilities, CIR Publishing Co., pp. 92-94.
4 Woo, J.T., Yhim, S.S. (2000). "Improvement of tunnel maintenance monitoring." Proceedings of the Korean Society of Civil Engineers Conference, pp. 33-36.
5 Woo, J.T., Yoo, C.S. (2000). Seoul Metropolitan Rapid Transit Corporation, Details manual of subway maintenance monitoring, pp. 50-60.
6 Woo, J.T. (2017a). "A study on behavior of the earth retaining structure by field measurement and numerical analysis." Journal of Korea Society of Disaster Information, Vol. 13, No. 3, pp. 286-295.   DOI
7 Seoul Metropolitan Rapid Transit Corporation (2002). Seoul subway maintenance monitoring, pp. 234-236.
8 Seoul Metropolitan Infrastructure Headquarters (2015). Improvement plan of Seoul subway monitoring management, pp. 70-90.
9 Woo, J.T. (2010). "A study of the present state analysis and development plans about construction monitoring and monitoring industry." Journal of Korean Society of Civil Engineers, Vol. 30, No. 2D, pp. 163-169.
10 Woo, J.T. (2017b). "Theoretical study on the durability standard of construction monitoring sensors." Proceedings of the Korean Geotechnical Society Fall Conference, Vol. 2, No. 1, pp. 168-169.
11 Woo, J.T. (2018). "A study on the loss and damage ratio of railroad tunnel maintenance monitoring sensor." Journal of Korea Society of Disaster Information, Vol. 14, No. 3, pp. 262-270.   DOI