• Title/Summary/Keyword: Measurement Window

Search Result 315, Processing Time 0.031 seconds

Breathing Measurement and Sleep Apnea Detection Experiment and Analysis using Piezoelectric Sensor

  • Cho, Seokhyang;Cho, Seung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.11
    • /
    • pp.17-23
    • /
    • 2017
  • In this paper, we implemented a respiration measurement system consisting of piezoelectric sensor, respiration signal processing device, and a viewer on a notebook. We tried an experiment for measuring respiration and detecting sleep apnea syndrome when a subject lay on a bed. We applied the respiration measurement algorithm to sensor data obtained from four subjects. In order to get a good graph shape, data manipulation methods such as moving averages and maximum values were applied. The window size for moving average was chosen as N=70, and the threshold value for each subject was customized. In this case, the proposed system showed 96.0% accuracy. When the maximum value among 90 data was applied instead of moving average, our system achieved 95.1% accuracy. In an experiment for detecting sleep apnea syndrome, the system showed that sleep apnea occurred correctly and calculated the average interval of sleep apnea. While infants or the elderly as well as patients with sleep apnea syndrome are lying down on a bed, our results are also expected to be able to cope with some accidental emergency situation by observing their respiration and detecting sleep apnea.

Measurement of Rn-222 Gas Concentration of Newly Constructed Apartment House in Gwangju Gwangsan-Gu (광주광역시 광산구 소재 신축 아파트 라돈가스 농도 계측)

  • Jang, Hee jun;Lee, Sang bock
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.257-261
    • /
    • 2015
  • Radon is produced after the Uranium-238 and thorium-232 undergone radioactive decay process is a colorless, odorless inert gas is stored in a basement or an enclosed space. Building materials are made by a rock or soil materials. Form of radon gas is introduced into the lungs through the respiratory tract and deposited in the lungs or bronchial Daughter nuclides radon causes lung cancer. In this study, To subject the Constructed Apartment in Gwangju Gwangsan-Gu, the position is closed window and opened window was measured using a measuring instrument for radon. The measured results indicate that the measurement was carried out in concentrations of radon gas measured at Newly Constructed Apartment is low than United states in the radon concentration in air public 4 pCi called radon gas baseline maximum allowable concentrations. The exposure caused by radon concentration of new construction apartment when on the measurement results is expected to be insignificant. However, when radon gas like this is that it accumulates in the body and lungs get damaged due to exposure, such as lung cancer often open the windows to reduce the radon concentration measurements, such as in radiation protection aspects to the ventilation to reduce exposure it is considered necessary.

Measurement of Tensile Properties of Copper Foil using Micro-ESPI Technique (마이크로 ESPI기법을 이용한 동 박막의 인장 특성 측정)

  • 김동일;허용학;기창두
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.8
    • /
    • pp.89-96
    • /
    • 2004
  • Micro-tensile testing system, consisting of a micro tensile loading system and micro-ESPI(Electronic Speckle Pattern Interferometry) system, has been developed for measurement of micro-tensile properties of thin micro-materials. Micro-tensile loading system had a load cell with the maximum capacity of 50N and micro actuator with resolution of 4.5nm in stroke. The system was used to apply a tensile load to the micro-sized specimen. During tensile loading, the micro-ESPI system acquired interferornetric speckle patterns in the deformed specimen and measured the in-plane tensile strain. The ESPI system consisted of a CCD-camera with a lens and the window-based program developed for this experiment. Using this system, stress-strain curves for 4 kinds of electrolytic copper foil 18$\square$m thick were obtained. From these curves, tensile properties, including the elastic modulus. yielding strength and tensile strength, were determined and also values of the plastic exponent and coefficient based on Ramberg-Osgood relationship were evaluated.

Speed measurement algorithm for low-resolution magnetic encoder of industrial electric vehicle (산업용 전기 차량의 저 분해능 마그네틱 엔코더를 사용한 속도 측정 방법)

  • Park, Gi-Hyoung;Jeong, Se-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.312-313
    • /
    • 2011
  • Recently, many industrial electric vehicles have been developed using various ac-motor drive technologies including field oriented vector control. Generally, a magnetic encoder is installed to have resistance to vibration and dust, and it is cost-effective. However, it is difficult to get an accurate rotor speed for high performance of vector control, because a resolution of the magnetic encoder is low and its phase accuracy is poor. In order to overcome this hardware problem, this study proposes a speed measurement algorithm using moving window for low-resolution magnetic encoder. This algorithm is experimentally tested and successfully applied to traction application of industrial electric vehicle.

  • PDF

Speed measurement algorithm for low-resolution magnetic encoder of industrial electric vehicle (산업용 전기 차량의 저 분해능 마그네틱 엔코더를 사용한 속도 측정 방법)

  • Park, Gi-Hyoung;Jeong, Se-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.316-317
    • /
    • 2011
  • Recently, many industrial electric vehicles have been developed using various ac-motor drive technologies including field oriented vector control. Generally, a magnetic encoder is installed to have resistance to vibration and dust, and it is cost-effective. However, it is difficult to get an accurate rotor speed for high performance of vector control, because a resolution of the magnetic encoder is low and its phase accuracy is poor. In order to overcome this hardware problem, this study proposes a speed measurement algorithm using moving window for low-resolution magnetic encoder. This algorithm is experimentally tested and successfully applied to traction application of industrial electric vehicle.

  • PDF

Simultaneous measurement of the parallelism and the relative surface figure of a nontransparent plate using visible light (가시광선을 이용한 불투과 평면창의 평행도 및 상대적 표면형상 동시측정)

  • 김연수;김현숙
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.2
    • /
    • pp.89-91
    • /
    • 2002
  • A test method that can measure the parallelism and the surface figure of an nontransparent plate using visible light is proposed. The testing system consists of a Twyman-Green interferometer. In addition, test results for the IR filter of IR MTF measuring system are described.

PIV Measurement on Airflows in the Abnormal Nasal Cavity with the Adenoid Vegetation (아데노이드 비대증에 의한 비정상 비강 내 유동의 PIV해석)

  • Kim, Sung-Kyun;Son, Young-Rak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.4
    • /
    • pp.518-523
    • /
    • 2003
  • Airflow in the nasal cavity of Korean adults is investigated experimentally by PIV measurement. Quantitative data for normal and abnormal nasal cavities with adenoid vegetation are obtained. The CBC PIV algorithm with window offset is used for PIV flow analysis. Average and RMS distributions are obtained for inspirational and expirational nasal airflows. Comparisons between western and Korean nasal airflows are appreciated. Due to the difference in geometry of the frontal part of nasal cavity, the flow near nares shows the difference. For the joint research on nasal deceases, PIV measurements of nasal airflow for nasal cavities with 50% and 70% adenoid vegetation are conducted for the first time. Comparisons in nasal airflows for both normal and abnormal cases are also appreciated.

Development of Echo PIV Using Ultrasound Contrast Agent (초음파 조영제를 애용한 Echo PIV 기법의 개발)

  • Kim, Hyoung-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1528-1534
    • /
    • 2004
  • The combination of ultrasound echo images with digital particle image velocimetry (DPIV) methods has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window offsetting were used to increase spatial resolution. The optimum concentration of the ultrasound contrast agent used for seeding was explored. Velocity validation tests in fully developed laminar pipe flow result of echo PIV showed good agreement with both optical PIV measurements and the known analytic solution based on a volume flow measurement.

Measurement and Correction of PCB Alignment Error Using Two Cameras (2대의 카메라를 이용한 PCB의 위치 오차 측정 및 보정)

  • 김천환;신동원
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.302-302
    • /
    • 2000
  • This paper presents the measurement and correction of PCB alignment errors for PCB-manufacturing machines. The conventional PCB-manufacturing machine doesn't have enough accuracy to accommodate the demand for high-resolution circuit pattern and high-density mounting capacity of electronic chips. It is because of alignment errors of PCB loaded to the PCB-manufacturing machine. Therefore, this study focuses on the development of the system which is able to measure and correct alignment errors whit high-accuracy. An automatic optical inspection part measures the PCB alignment error using two cameras, and the high-accuracy 3-axis stage makes correct of these error. The operating system is run in the environment of Window 98 (or NT). Finally we implemented this system to PCB screen printer and PCB exposure system.

  • PDF

A study on the pulse measurement system and algorithm using by PIN type devices (PIN type 소자를 이용한 맥박 측정 장치 및 알고리즘에 관한 연구)

  • Kim, Sheen-Ja;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.455-457
    • /
    • 2011
  • PIN type의 LED(${\lambda}=630nm$)와 photo TR을 이용하여 PPG 센서를 제작하였다. 이 때, LED의 광출력은 window 통과 후, 약 $240{\mu}W$이다. 그리고 인체에서 흡수 및 반사가 이루어진 후의 광파워는 더욱 작기 때문에 이를 보완하기 위해 photo TR을 LED 양측으로 배치하여 주변으로 반사하는 광을 측정하였다. 측정 된 신호는 filter와 OP amp.를 이용하여 1차 처리과정을 거치고, 알고리즘을 이용하여 2차 처리 하였다. 또한 알고리즘은 평상시를 포함하여 운동시에도 측정이 가능하도록 설계하였다.

  • PDF