• Title/Summary/Keyword: Measurement Window

Search Result 316, Processing Time 0.033 seconds

Full-scale Mock-up Measurement of a Double Glazed Window System Equipped with Sunlight Controls (광기능성 창호시스템의 동절기 채광특성에 관한 목업연구)

  • Kim, Gon
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.4
    • /
    • pp.35-42
    • /
    • 2008
  • Besides genuine skin and clothes, it is called that building is third skin for us. That means the skin of buildings is the most important factor for our man-made environment. The issues in designing the building envelope include the insulation, infiltration, ventilation and bridging in windows. Getting light into the space safely and providing views to outdoor, additionally, are key things with the building envelope design. A deep-rooted preference for full view is still alive with large area of glass. Balcony expansion is legalized in apartment houses, which causes lots of environmental problems. Without balcony space, the adjacent space to unshaded window is exposed to the direct sun. A window can have many layers and the inner space can be utilized with an automatic blind system. Recently, the refurbished version of a double-glazed window system has been developed for the purpose of minimizing energy loss occurred around windows. For the better daylight control with equipped blind system, a set of adjustment technique of blind slats was tested in a mock-up building and recommended the detail operation. Not surprisingly, the optimized blind system can be oriented to enhance the uniformity in light distribution and direct glare from the sky as well..

A Study on Optimization of the Overall Measurement System for HEMU-400X (차세대고속열차 종합계측시스템 최적화 방안 연구)

  • Lee, Young-Yeob;Ryu, Sang-Hyun;Lee, Jin-Jong;Kim, Kyung-Taek
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1-6
    • /
    • 2011
  • In Korea, high-speed train(HEMU-400X) system with distributed power is being developed, and the highest test speed of this train is 400km/h. This developed the first high-speed train as a distributed power train in Korea, as well as for the development of train system and evaluation system included evaluation technology is needed. Accordingly, a comprehensive and efficient OMS(Overall Measurement System) was build up for verifying the performance of HEMU-400X. By the case study of the G7 and TTX, OMS of HEMU-400X was improved the test performance and maintainability. In particular, the existing Window-based systems has a limit to the control, due to this reason OMS applying enhanced RT(Real-time) system. In this study, compare the advantages and disadvantages of RT systems with Window-based systems, as well as the configuration of the RT systems.

  • PDF

Local stereo matching using combined matching cost and adaptive cost aggregation

  • Zhu, Shiping;Li, Zheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.1
    • /
    • pp.224-241
    • /
    • 2015
  • Multiview plus depth (MVD) videos are widely used in free-viewpoint TV systems. The best-known technique to determine depth information is based on stereo vision. In this paper, we propose a novel local stereo matching algorithm which is radiometric invariant. The key idea is to use a combined matching cost of intensity and gradient based similarity measure. In addition, we realize an adaptive cost aggregation scheme by constructing an adaptive support window for each pixel, which can solve the boundary and low texture problems. In the disparity refinement process, we propose a four-step post-processing technique to handle outliers and occlusions. Moreover, we conduct stereo reconstruction tests to verify the performance of the algorithm more intuitively. Experimental results show that the proposed method is effective and robust against local radiometric distortion. It has an average error of 5.93% on the Middlebury benchmark and is compatible to the state-of-art local methods.

A Design of Real Time Measurement System for EMG Silent Period Under Window Base (윈도우 환경하에서 근전도의 실시간 Silent Period 측정 시스템 설계)

  • 강병길;김태훈;이영석;김덕영;김세동;김성환
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.10
    • /
    • pp.611-617
    • /
    • 2003
  • A mechanical or electrical stimulation to the mandibular symphysis during a maximal voluntary clenching of the teeth always produces a jaw jerk followed by a silent period (transient stops) in the masseteric EMG (electromyogram). Generally, a mechanical stimulation is followed by a single silent period, and an electrical stimulation is followed by multiple silent periods. In this paper, we propose a new algorithm for determining the duration of the masseter silent period. The decision approach in essentially based upon a segmentation algorithm consisted of variance filter, median filter and gaussian filter. The new adaptive digital notch filter using R-CLMS(reverse constrained least mean-squared) algorithm is proposed for the elimination of powerline(60Hz) noise. At the same time, we design a real time measurement system for the EMG silent period under Window base.

A Study on Respiration Measurement Using a Smartphone (스마트폰을 이용한 호흡 측정에 관한 연구)

  • Kang, Sung Jin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.3
    • /
    • pp.108-112
    • /
    • 2018
  • In this paper, a respiration measurement method using FMCW signal for off-the-shelf smartphone is presented and investigated. The proposed algorithm transmits FMCW signal periodically instead of transmitting continuously so that one can reduce the power consumption from speaker in smartphone and the algorithm complexity. In order to eliminate the clicking noise generated when transmitting FMCW signal, Tukey window with ${\alpha}=0.01$ is applied to prevent the noise from being heard. An application program for Android OS which can transmit FMCW signal through speaker and record the reflected signals through MIC has been developed. Since the total duration of the signal transmission is set to 20msec per 1 second for the experiments, the power consumption can be decreased by 80% compared to the continuous transmission. It was confirmed that the clicking noise is inaudible as long as a smartphone is located at more than 10cm from ears. In the experiments on a sleeping child, the breathing signal of about 0.27Hz was measured.

Windowed Quaternion Estimator For Gyroless Spacecraft Attitude Determination

  • Kim, Injung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.167.5-167
    • /
    • 2001
  • Single point attitude determination method provides an optimal attitude minimizing the Wahba loss function. However, for the insufficient number of measurement vectors, the conventional single point methods has no unique solution. Thus, we introduce the sequential method to and an optimal attitude minimizing the windowed loss function. In this paper, this function is de ned as the sum of square errors for all measurement vectors within the axed sliding window. For simple implementation, the proposed algorithm is rewritten as a recursive form. Moreover, the covariance matrix is derived and expressed as a recursive form. Finally, we apply this algorithm to the attitude determination system with three LOS measurement sensors.

  • PDF

Memory Characteristics of Al2O3/La2O3/SiO2 Multi-Layer Structures for Charge Trap Flash Devices (전하 포획 플래시 소자를 위한 Al2O3/La2O3/SiO2 다층 박막 구조의 메모리 특성)

  • Cha, Seung-Yong;Kim, Hyo-June;Choi, Doo-Jin
    • Korean Journal of Materials Research
    • /
    • v.19 no.9
    • /
    • pp.462-467
    • /
    • 2009
  • The Charge Trap Flash (CTF) memory device is a replacement candidate for the NAND Flash device. In this study, Pt/$Al_2O_3/La_2O_3/SiO_2$/Si multilayer structures with lanthanum oxide charge trap layers were fabricated for nonvolatile memory device applications. Aluminum oxide films were used as blocking oxides for low power consumption in program/erase operations and reduced charge transports through blocking oxide layers. The thicknesses of $SiO_2$ were from 30 $\AA$ to 50 $\AA$. From the C-V measurement, the largest memory window of 1.3V was obtained in the 40 $\AA$ tunnel oxide specimen, and the 50 $\AA$ tunnel oxide specimen showed the smallest memory window. In the cycling test for reliability, the 30 $\AA$ tunnel oxide sample showed an abrupt memory window reduction due to a high electric field of 9$\sim$10MV/cm through the tunnel oxide while the other samples showed less than a 10% loss of memory window for $10^4$ cycles of program/erase operation. The I-V measurement data of the capacitor structures indicated leakage current values in the order of $10^{-4}A/cm^2$ at 1V. These values are small enough to be used in nonvolatile memory devices, and the sample with tunnel oxide formed at $850^{\circ}C$ showed superior memory characteristics compared to the sample with $750^{\circ}C$ tunnel oxide due to higher concentration of trap sites at the interface region originating from the rough interface.

Development of Dual-Window Phantom for Output Measurement of Medical Linacs (의료용 선형가속기 출력측정용 듀얼윈도우 팬텀 개발)

  • Jeong, Dong Hyeok;Kwak, Dong Won;Moon, Young Min;Kang, Yeong-Rok;Kim, Jeung Kee;Lee, Man Woo
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.229-233
    • /
    • 2012
  • A small water phantom (dual-window phantom) was developed to improve the output measurement efficiency of medical linacs. This phantom is suitable for determining the quality index and output dose for high-energy photon beams. The phantom has two opposite windows and two independently rotating axes. The two axes measure the tissue phantom ratio (TPR) and the percentage depth dose (PDD) simply without requiring chamber movement by rotating the phantom around its axis. High-energy photon beams from a Co-60 irradiator and a medical linac were used to evaluate the phantom. The measured quality index is in good agreement with the reference values; the measured and reference values are within 0.2% of each other for the Co-60 gamma rays and within 1.4% for 6 and 10 MV X-rays. This phantom is more practical for routine output measurements, resulting in the prevention of potential human errors.

Radon Concentration at N-Kindergarten in G-City (G광역시 N유치원의 라돈 농도)

  • Park, Yun;Kim, Wonjun
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.421-424
    • /
    • 2015
  • In this study, To subject the constructed at N-kindergarten in G-city, the position is closed window and opened window was measured using a measuring instrument for radon. The measured results indicate that the measurement was carried out in concentrations of radon gas measured at N-kindergarten is low than United States in the radon concentration in air public 4pCi called radon gas baseline maximum allowable concentrations. As a result, radon exposure is not a problem, but when the accumulation radon gas in the lungs, get damaged same lung cancer. Be defensive of kindergarten windows open for ventilation and dust removal be possible to reduce the exposure.

Constructed Sound Field of an Induction Motor Using Cylindrical Acoustic Holography (원통형 음향 홀로그래피를 이용하여 구성한 유도전동기의 방사 음장)

  • 김시문;김양한
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.919-929
    • /
    • 1997
  • Induction motors are used in many areas to transform electrical energy to mechanical energy. In the design of an induction motor, not only energy efficiency but also noise becomes an important factor. To effectively address the noise problem, it will be convenient if one can see where and how noise is generated and propagated. In this study sound radiation by an induction motor is visualized using cylindrical acoustic holography. To minimize the bias error by window effect Minimum Error Window(MEW) is used. Its performance is verified by numerical simulations. Based on these theoretical understanding, sound pressure measurement with an induction motor are performed. Not only sound radiation are visualized but sound pressure level and sound power level are also estimated. Results show that the main source is located at nearly bottom part of the motor and the total sound pressure level is 49dB, which satisfies the guideline value suggested by the KS C 4202.

  • PDF