• Title/Summary/Keyword: Measurement Window

Search Result 315, Processing Time 0.026 seconds

Evaluation on Noise Level of One-Room Type Multi-Family Housing Around Campus (대학주변 원룸형 다가구주택의 소음측정평가)

  • Choi, Yoon-Jung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.95-100
    • /
    • 2003
  • The purpose of this study is to evaluate the noise environment of one-room type multi-family housing around the campus. The field measurements on equivalent noise level of indoor and outdoor were carried out in 6 subject house units during the 26th${\sim}$28th of November 2002. The results are as follows. 1) Outdoor noise levels of 6 subject buildings were distributed 52.8${\sim}$65.3dB(A) and were inappropriate to the standard for environmental noise, 55dB(A). 2) Indoor noise level of 6 subject house units were measured 27.5${\sim}$63.5dB(A). These values were higher than the indoor noise standard (40dB(A)) except subject house D(average 37.6dB(A)). 3) It was found that the differences of indoor noise levels between subject house units were caused by resident's living factor, characteristics of window, and existence of balcony.

  • PDF

Two-Terminal Numerical Algorithm for Single-Phase Arcing Fault Detection and Fault Location Estimation Based on the Spectral Information

  • Kim, Hyun-Houng;Lee, Chan-Joo;Park, Jong-Bae;Shin, Joong-Rin;Jeong, Sang-Yun
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.460-467
    • /
    • 2008
  • This paper presents a new numerical algorithm for the fault location estimation and arcing fault detection when a single-phase arcing ground fault occurs on a transmission line. The proposed algorithm derived in the spectrum domain is based on the synchronized voltage and current samples measured from the PMUs(Phasor Measurement Units) installed at both ends of the transmission lines. In this paper, the algorithm uses DFT(Discrete Fourier Transform) for estimation. The algorithm uses a short data window for real-time transmission line protection. Also, from the calculated arc voltage amplitude, a decision can be made whether the fault is permanent or transient. The proposed algorithm is tested through computer simulation to show its effectiveness.

Development of Fish Farm Monitoring System Using Image Processing Technique -1. Motion Measurement for Moving Body in the Wave Tank- (화상처리 기법을 애용한 어장 조성효과의 모니터링 시스템 개발 -1. 실험수조에서의 이동물체에 대한 운동계측-)

  • JEE Myoung-Seok;KIM Seoung-Gun;JEONG Seok-Kwon;KIM Sang-Bong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.3
    • /
    • pp.309-315
    • /
    • 1995
  • This paper describes a monitoring system for fish farm formation effect based on personal computer by using an image processing technique. This method is based on image processing technique incorporating concept of window and threshold processing to track the target object and to distinguish it from background. The image processing program runs in the veal time so that all program modules are able to process multi-task. The effectiveness is evaluated through the comparative study on the motion of lantern net for the scallop culturing by wave action in an experimental wave tank.

  • PDF

박막형 전기변색 소자 특성 연구

  • Hwang, Do-Yeon;Park, Seong-Eun;Park, Jae-Seong;Kim, Sam-Su;Kim, Heon-Gon;No, Jae-Seung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.266.2-266.2
    • /
    • 2014
  • 박막형 전기변색 소자의 특성파악을 위하여, 투명전극층으로 ITO를 이용하였으며, 가장 우수한 전기변색 특성을 나타내는 것으로 알려져 있는 $WO_3$를 DC magnetron sputtering방식을 이용하여 증착하였으며, 무기전해질층은 E-beam evaporation 방식으로 증착하고, 이온저장층을 제외한 박막형 전기변색 소자 구조를 제작하여 전기변색층의 증착조건에 따른 전기변색 소자 특성 연구를 수행하였다. 증착온도와 혼합gas의 분합비 등의 조건의 변화를 통한 박막 특성을 확인하였으며, XRD, SEM, TEM, Transmission Measurement 등을 이용하여 박막 분석을 하였다. ITO층의 저항에 따른 변색효율을 확인하였으며, $WO_3$층의 산소분합비에 따른 투과율변화를 분석하였다. 이온저장층을 제거한 상태에서의 박막형 전기변색 소자의 투과율변화가 가시광선 영역에서 45%의 변색효과를 확인하였다.

  • PDF

Noise Reduction of a Small D/C Motor using 6 Sigma Process (6 시그마 프로세스를 이용한 소형 직류 모터의 소음 절감)

  • 차원준;최연선
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.509-514
    • /
    • 2002
  • This paper studies on the noise reduction for a small automobile DC Motor (a window motor) using the 6 sigma process. The application of 6 sigma process suggested reliable and valuable statistical data for the quality of the DC motor at the production line. In the measurement step in 6 sigma process, the FMEA(Failure Mode Effect Analysis) were used for the detection of noise sources. The application of 6 sigma process gave not only the improving method for the quality of the DC motor but also the confidence of improvement itself since it was done on the basis of the test results for a number of DC motors at the production line. Consequently the 6 sigma process was proved very effective for the noise reduction at the production line.

  • PDF

Geological Structures of the Taebaek-Hajang Area, Samcheog Coalfield, Korea (삼척탄전(三陟炭田) 태백(太白)-하장지역(下長地域)의 지질구조(地質構造))

  • Kim, Jeong Hwan;Kim, Young Seok
    • Economic and Environmental Geology
    • /
    • v.24 no.1
    • /
    • pp.27-41
    • /
    • 1991
  • Taebaeg-Hajang area, in the northern part of Taebaeg city, comprises of Paleozoic sedimentary sequences and Cretaceous intrusive and volcanoclastic rocks. The rocks in the area are affected by folding and thrusting during the Bulgugsa Orogeny. In Taebaeg area, geologic structures related with thrust movement are dominant. These structures are small scale of klippe and window, back thrust, and asymmetric folds related with blind thrust. Tear fault or compartment fault due to differential movement of thrust sheets have "en echelon" arrays. Small scale transpression effects occurred along these faults and produced the flower structure. According to strain measurement using by ooids from limestone and quartz grains from quartzite, strain ratios are very low and strain ellipsoids are apparent oblate type.

  • PDF

Pixel-based disparity estimation for Intermediate View Reconstruction of Multi-view images (다시점 동영상의 중간시점영상 생성을 위한 화소 기반의 변이 예측 기법)

  • Choi, Mi-Nam;Baek, Yun-Ki;Kim, Dong-Wook;Yoo, Ji-Sang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.49-52
    • /
    • 2006
  • 본 논문은 다시점 카메라로부터 획득된 다시점 영상을 이용하여, 영상내의 모든 화소에 대한 정확한 변이 정보를 획득하는 알고리듬을 제안한다. 제안한 방법은 정합창(measurement window)을 사용하는 화소기반 정합방법을 통해 정확한 변이 추정과 비용 함수 계산시 반복적인 계산을 줄임으로써 전체적인 수행 속도를 향상시킬 수 있다. 정확한 변이 정보를 획득하는데 있어서 가려진 영역이 많은 영향을 미친다. 또한 가려진 영역의 판단 및 처리는 2대의 카메라로는 한계가 있다. 따라서 본 논문에서는 평행식으로 구성된 5대 이상의 다시점 카메라로부터 획득된 다시점 영상을 사용함으로써 변이 정보의 신뢰도를 높이고, 가려진 영역을 처리할 수 있다. 또한 비용 함수 계산의 반복성을 이용하여 계산량을 줄임으로써 전체적인 수행시간을 줄인다. 이렇게 획득된 변이 정보는 다시점 영상의 중간시점영상 생성을 위해 사용된다.

  • PDF

A Fast Hierarchical Motion Vector Estimation Using Mean Pyramids (평균 피라미드를 이용한 계층적 고속 이동벡터 추정)

  • 남권문;김준식;박래홍;심영석
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.6
    • /
    • pp.35-48
    • /
    • 1993
  • In this paper, a hierarchical motion vector estimation algorithm using pyramidal structure is proposed. Using a smaller measurement window at each level of a pyramid than that of the conventional scheme, the proposed algorithm, based on the TSS(three step search), reduces the computational complexity greatly with its performance comparable to that of the TSS. By increasing the number of cnadidate motion vectors which are to be used as the initial search points for motion vector estimation at the next level, the performance improves further. Then the computational complexity of the proposed hierarchical algorithm depends on the number of candidate motion vectors, with its PSNR (peak signal to noise ratio) ranging between those of the TSS and the full search method. The simulation results with two different block sizes and various test sequences are given and its hardware implementation is also sketched.

  • PDF

Development of a Ubiquitous Sensor for Monitoring Insulators and Arresters (애자/피뢰기 모니터링을 위한 유비쿼터스 센서 개발)

  • Kil, G.S.;Shin, G.C.;Park, J.K.;Sim, J.W.;Song, J.Y.
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.736-741
    • /
    • 2006
  • In this study, a ubiquitous sensor for condition monitoring of insulators and lightning arresters installed in power distribution lines and electric traction vehicles is presented. The sensor consists of two parts; a leakage current measurement and a lightning surge detection. Measured data are transmitted to a supervisory computer through ZigBee protocol based on IEEE 802.15.4. To detect leakage current, a window type Mn-ZCT is used and a low-noise amplifier with a gain of 60dB is designed, and this can measure leakage current in ranges of $100{\mu}A{\sim}5mA$. A sample-hold(S/H) and a Rogowski coil are injected to analyze the magnitude of surge current in ranges from 500A to 10kA with $8/20{\mu}s$-waveform.

  • PDF

Field Measurement of Infiltration in New Apartments using De-pressurization Method (신축 공동주택에서 감압법을 이용한 기밀성능 실측 연구)

  • Yoon, Jae Ock
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.27-32
    • /
    • 2013
  • Infiltration is air flow that occurs through cracks in buildings. According to level and kind of infiltration, the cooling load and heating load in buildings may increase. In this study I conducted field measurements to evaluate air tightness in 27 new apartment units. Field measurements for new apartments was the focus. For the de-pressurization method, the equipment utilized to gauge airtightness included KNS-5000C and KNS-4000 which were installed on the window in order to measure indoor air leakage. The results are summarized as follows. The average ACH50 of a $59m^2$ APT was 3.98, 3.82 for a $84m^2$ APT, and 2.73 for a $114m^2$ APT. The total average ACH50 of 27units was 3.51.