• 제목/요약/키워드: Measurement Uncertainty Analysis

검색결과 328건 처리시간 0.026초

선회유동 교란에 따른 벤투리 유량측정의 불확실성 해석 (Effect of Swirl Flow Disturbance on Uncertainty of Flow Rate Measurement by Venturi)

  • 이정호;윤석호;유청환;박상진;정장환
    • 한국유체기계학회 논문집
    • /
    • 제12권6호
    • /
    • pp.18-25
    • /
    • 2009
  • Venturi has long been an attractive method of measuring flow rate in a variety of engineering applications since pressure loss is relatively small compared with other measuring methods. The current study focuses on making detailed uncertainty estimations as the upstream flow disturbance affects uncertainty levels of the flow rate measurement. Upstream flow disturbance can be determined by 9 different swirl generators. Measurement uncertainty of flow rate has been estimated by a quantitative uncertainty analysis which is based on the ANSI/ASME PTC 19.1-2005 standard. The results of flow rate uncertainty analysis show that the case with systematic error has higher than that without systematic error. Especially the result with systematic error exhibits that the uncertainty of flow rate was gradually increased by swirl flow disturbance. The uncertainty of flow rate measurement can be mainly affected by differential pressure and discharge coefficient. Flow disturbance can be also reduced by increasing of the upstream straight length of Venturi.

GC/MS를 이용한 모발 중 메스암페타민 및 암페타민 분석의 측정불확도 평가 (Uncertainty Evaluation of the Analysis of Methamphetamine and Amphetamine in Human Hair by GC/MS)

  • 김진영;김종상;김민경;이재일;서용준;인문교
    • 약학회지
    • /
    • 제51권3호
    • /
    • pp.206-213
    • /
    • 2007
  • Recently estimating the uncertainty of an analytical result has become an essential part of quantitative analysis. This study describes the uncertainty of the measurement for the determination of methamphetamine and its major metabolite amphetamine in human hair, The method consists of washing, drying, weighing, incubation and extraction with methanolic HCI solution, clean-up, trifluoroacetyl derivatization, and qualification/quantification of residues by gas chromatography/mass spectrometry (GC/MS). Traceability of measurement was established through traceable standards and calibrated volumetric equipment and measuring instruments. Measurement uncertainty associated with each analyte in real samples was estimated using quality control (QC) data. The main source of combined standard uncertainty comprised two components, which are uncertainties associated with calibration linearity and variations in QC, while those associated with preparation of analytical standards and sample weighing were not so important considering the degree of contribution. Relative combined standard uncertainties associated with the described method ranged for individual analytes from 4.99 to5.03%.

간접 교정에 의한 다회선 초음파유량계 UR-1000 불확도 분석 (Uncertainty Analysis for the Multi-path Ultrasonic Flowmeter UR- 1000 with Dry Calibration)

  • 황상윤;박성하;박경암
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.378-386
    • /
    • 2002
  • Multi-path ultrasonic Sow measurement system uncertainty is determined by assigning an expected error of each component of flow measurement and then defining the total flow measurement uncertainty as square root of the sum of squared values of the individual error. Sources of uncertainty for flow measurement are geometry, transit time and velocity profile integration uncertainty. A theoretical uncertainty model for multi-path ultrasonic transit time flowmeter configured with parallel 5 chords, is derived from and calculated by dry calibration method.

  • PDF

둔감탄약 시험의 측정불확도 산출 방안 연구 (A Study on Measurement Uncertainty of Insensitive Munitions Tests)

  • 김민;김종명;양승호;선태부
    • 품질경영학회지
    • /
    • 제45권3호
    • /
    • pp.533-547
    • /
    • 2017
  • Purpose: This study proposes the main sources of uncertainty and uncertainty analysis of a measurement system of insensitive munitions tests. Methods: We established the mathematical model for calculating measurement uncertainty of insensitive munitions tests, conducted experiments for calculating uncertainties of dynamic sensitivity and overshoot value, and estimated the distributions of uncertainty factors. Results: The measurement uncertainty calculation methods are presented, which include experimental data processing methods for calculating uncertainties of dynamic sensitivity and overshoot value. Conclusion: The measurement of explosion pressure in insensitive munitions tests is an important issue to the reporting test results and classifying reaction types. The more efforts to ensure the reliability of the insensitive munitions tests results are required.

엔진 고공 시험에서 공기 유량 측정용 벤투리 파이프의 제작 및 측정 불확도 분석 (Manufacture and Measurement Uncertainty Analysis of a Venturi Pipe for Airflow Measurement in Altitude Engine Test)

  • 양인영;오중환
    • 한국유체기계학회 논문집
    • /
    • 제13권6호
    • /
    • pp.36-41
    • /
    • 2010
  • Design, manufacture and calibration procedures of a venturi pipe flowmeter for airflow measurement in altitude engine test were discussed. Altitude engine test using venturi pipe was given as an example. The venturi was designed per the ISO standard of ISO5167, and was intented to include the entire airflow range in the test envelope of the gas turbine engine. Measurement uncertainty analysis was performed in the design procedure to investigate the effect of venturi geometry and sensor specification upon the measurement uncertainty. Manufacturing process was designed to minimize the deviation from the geometry of design. Calibration was performed to get the relationship between the discharge coefficient and the pipe Reynolds number. Then the uncertainty was assessed again using real data acquired during engine test. Through these procedures, it was possible to maintain the uncertainty of airflow measurement under 1 % for most of the operating envelope of the gas turbine engine. The discharge coefficient of the venturi pipe showed agreement with the value suggested in the ISO standard ISO5167-4 within 0.6 %.

고체재료의 유전율 측정용 Cell의 불확도 분석과 보상 (Uncertainty Analysis and Compensation of the Cell for Permittivity Measurement of Solid Materials)

  • 김한준;유광민;강전홍;한상옥
    • 한국전기전자재료학회논문지
    • /
    • 제21권1호
    • /
    • pp.53-56
    • /
    • 2008
  • The commercial parallel plate electrodes system with guard-ring electrode have been widely used for measurement of dielectric constants of solid materials. And the specification of the electrodes system is about 1 % of measurement uncertainty. This measurement uncertainty is only estimated the error come from mechanical measurements such as the area of the electrodes and the gap between the electrodes except the error come from the air gap between the electrodes and dielectric specimen. Because it is impossible to measure the air gap. This study analyze the total measurement uncertainties of the commercial dielectric constant test cell using 3 kinds of Standard Reference Materials. As a results, the total measurement uncertainty is much bigger than 1 % and the most of the uncertainty can be reduced by compensation of the error values evaluated in this study.

측정 프로세스의 변동 요인 조사 방법 개발 (Development of an Investigation Method for Variation Factors of Measurement Processes)

  • 최인수;강창욱
    • 산업경영시스템학회지
    • /
    • 제39권2호
    • /
    • pp.72-81
    • /
    • 2016
  • There can be included a variety of uncertainties in all measurement results whether we can perceive or not on the causes. These uncertainties may end up in lowering the reliability of measurement results and also deteriorate the level of quality. For the purpose, we tried to combine the strengths of measurement uncertainty and measurement system analysis together to present a practical flowchart so as to verify those potential variation factors in general measurement processes. As a case study, we did an experiment and gathered data on the length between two holes of an engine cylinder head which is a core part for vehicles with a coordinate measuring machine and estimated nine uncertainty factors of it. Consequently, it was identified that the four primary factors among the nine which were related to the measurement standard, random errors or spread of the repeat measurements, differences between the coefficients of thermal expansion and the environment especially had been the influence around the laboratory. Since it is impossible to analyze the equipment and appraisal variations respectively through the only measurement uncertainty, we have used the measurement system analysis following the flowchart. Showing the result of being just about 0.5% lower for the appraisal variation, and the equipment variation occupied about 7% for the total Gage R&R. Through this research, we have come to a conclusion that much more detail analysis on variation factors can be possible to be identified in measurement processes by using the developed flowchart which is composed of measurement uncertainty and measurement system analysis. Therefore, we expect engineers who are involved in quality and measurements to utilize this developed method.

열전압변환기를 이용한 고주파전압계의 교정과 측정불확도 (Uncertainty in the Course of Calibration of RF Multimeter using TVC)

  • 박정규;박석주;이환상;장경승;박명선
    • 한국전자파학회논문지
    • /
    • 제13권1호
    • /
    • pp.47-52
    • /
    • 2002
  • 1993년도 ISO에서 \"Guide to Expression of Uncertainty in Measurement\"를 발표함으로써 측정과학에 있어 측정결과의 오차분석 방법을 폐기하기로 사실상 선언하였다. 그리하여 측정의 소급성과 신뢰성을 확보한다는 전제 하에 오차의 개념을 버리고 측정시의 측정불확도를 분석하는 것이 측정과학에 있어서 세계적인 추세이다. 본 논문에서는 전달표준인 열 전압변환기를 사용하여 고주파전압계의 정밀 교정에서 불확도를 산출하기 위하여 수학적 모델을 설정하고 측정에 관계되는 모든 불확도 요인을 분석하였다. 케이블의 영향과 열전대감지기와 직류전압계의 상관관계, 직류소스, RF소스, 감쇠기, 반사계수와 DUT 등 측정에 있어서 관계되는 모든 불확도요인을 분석하여 확장불확도를 산출하였다.확도를 산출하였다.

부가저항 실험의 불확실성 연구 (Uncertainty Study of Added Resistance Experiment)

  • 박동민;이재훈;김용환
    • 대한조선학회논문집
    • /
    • 제51권5호
    • /
    • pp.396-408
    • /
    • 2014
  • In this study, uncertainty analysis based on ITTC(International Towing Tank Conference) Recommended Procedures is carried out in the towing-tank experiment for motion responses and added resistance. The experiment was conducted for KVLCC2 model in head sea condition. The heave, pitch and added resistance were measured in different wave conditions, and the measurement was repeated up to maximum 15 times in each wave condition in order to observe the uncertainty of measured data. The uncertainty analysis was carried out by adopting the ISO-GUM(International Organization for Standardization, Guide to the Expression of Uncertainty in Measurements) method recommended by ITTC. This paper describes the details about the analysis method, uncertainty and the measured uncertainty for each source. The uncertainty analysis results are summarized as a tabular form. To validate the accuracy of the present measurement, the experimental results are compared with the results of numerical computation and other experiment. From the present uncertainty analysis, the main sources of uncertainty are identified, which can be very useful to improve the accuracy for added resistance experiment.

고정밀 공작기계 이송장치의 정밀도 측정방법 및 불확도 요인에 관한 연구 (A Study on the Measurement Method and Uncertainty Factors for Precision Inspection to Feed Unit of High Precision Machine Tool)

  • 김상화;김병하;최우각
    • 한국기계가공학회지
    • /
    • 제11권4호
    • /
    • pp.55-61
    • /
    • 2012
  • Very important content in performance evaluation of machine tool is positioning accuracy and repeatability precision measurements of feed mechanism. A study analyses the measurement method and uncertainty factors by ISO-based test method. Reliable results can't be derived without the notion of measurement uncertainty. The reason is that the measured value includes a lot of uncertain factors. Finding the factor that affects the measurement of parameter is important for estimation of measurement precision. In this paper, the evaluation of uncertainty analysis about positioning accuracy and repeatability precision measurements of high precision feed mechanism is presented to evaluate the important factors of uncertainty.