• Title/Summary/Keyword: Measurement Set

Search Result 1,845, Processing Time 0.027 seconds

An Electrical Conductivity Reconstruction for Evaluating Bone Mineral Density : Simulation (골 밀도 평가를 위한 뼈의 전기 전도도 재구성: 시뮬레이션)

  • 최민주;김민찬;강관석;최흥호
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.261-268
    • /
    • 2004
  • Osteoporosis is a clinical condition in which the amount of bone tissue is reduced and the likelihood of fracture is increased. It is known that the electrical property of the bone is related to its density, and, in particular, the electrical resistance of the bone decreases as the bone loss increases. This implies that the electrical property of bone may be an useful parameter to diagnose osteoporosis, provided that it can be readily measured. The study attempted to evaluate the electrical conductivity of bone using a technique of electrical impedance tomography (EIT). It nay not be easy in general to get an EIT for the bone due to the big difference (an order of 2) of electrical properties between the bone and the surrounding soft tissue. In the present study, we took an adaptive mesh regeneration technique originally developed for the detection of two phase boundaries and modified it to be able to reconstruct the electrical conductivity inside the boundary provided that the geometry of the boundary was given. Numerical simulation was carried out for a tibia phantom, circular cylindrical phantom (radius of 40 mm) inside of which there is an ellipsoidal homeogenous tibia bone (short and long radius are 17 mm and 15 mm, respectively) surrounded by the soft tissue. The bone was located in the 15 mm above from the center of the circular cross section of the phantom. The electrical conductivity of the soft tissue was set to be 4 mS/cm and varies from 0.01 to 1 ms/cm for the bone. The simulation considered measurement errors in order to look into its effects. The simulated results showed that, if the measurement error was maintained less than 5 %, the reconstructed electrical conductivity of the bone was within 10 % errors. The accuracy increased with the electrical conductivity of the bone, as expected. This indicates that the present technique provides more accurate information for osteoporotic bones. It should be noted that tile simulation is based on a simple two phase image for the bone and the surrounding soft tissue when its anatomical information is provided. Nevertheless, the study indicates the possibility that the EIT technique may be used as a new means to detect the bone loss leading to osteoporotic fractures.

Development of Smart Packaging for Cream Type Cosmetic (크림 제형 화장품용 스마트 패키징 기술 개발)

  • Jeon, Sooyeon;Moon, Byounggeoun;Oh, Jaeyoung;Kang, Hosang;Jang, Geun;Lee, Kisung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.25 no.3
    • /
    • pp.79-87
    • /
    • 2019
  • The degree of cosmetic's oxidation depends on the storage conditions and external conditions when using the product. The microbial contamination and oxygen exposure often results in the quality deterioration of cosmetics. In addition, the problem is that consumers often use cream-type cosmetics, which have short expiration period (6-12 months), even after the product is expired. When using the deteriorated cosmetics, it can be fatal to consumers' safety including some symptoms such as folliculitis, rashes, edema, and dermatitis. Therefore, it is necessary to develop sealed smart packaging for cosmetics to prevent the deterioration of cosmetics and improve consumer safety. In this study, we have developed smart packaging design for cosmetics that can measure the surrounding environment and expiration date for the cosmetics in the real time. In addition, the smart packaging includes sensor, which are linked to the mobile application. Users can find out the measurement results through the application. Also, the packaging design and functions were set up based on the survey results by the user and feasible model can be produced based on user choice. The measurement in the three environment has been done after manufactured the sensor, PCB, and mobile application. As a result, it works normally within a certain range under all three environmental conditions. It is believed that the information on expiration dates and storage environment can be efficiently delivered to the consumers through developed cosmetics smart packaging and applications. The development of UI/UX design for consumer is further studied. The UX/UI design of the application plays an essential role in achieving this goal through the commercialization the cosmetic products in the wide range.

A Study On Design of ZigBee Chip Communication Module for Remote Radiation Measurement (원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈 설계에 대한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.552-558
    • /
    • 2014
  • This paper suggests how to design a ZigBee-chip-based communication module to remotely measure radiation level. The suggested communication module consists of two control processors for the chip as generally required to configure a ZigBee system, and one chip module to configure a ZigBee RF device. The ZigBee-chip-based communication module for remote radiation measurement consists of a wireless communication controller; sensor and high-voltage generator; charger and power supply circuit; wired communication part; and RF circuit and antenna. The wireless communication controller is to control wireless communication for ZigBee and to measure radiation level remotely. The sensor and high-voltage generator generates 500 V in two consecutive series to amplify and filter pulses of radiation detected by G-M Tube. The charger and power supply circuit part is to charge lithium-ion battery and supply power to one-chip processors. The wired communication part serves as a RS-485/422 interface to enable USB interface and wired remote communication for interfacing with PC and debugging. RF circuit and antenna applies an RLC passive component for chip antenna to configure BALUN and antenna impedance matching circuit, allowing wireless communication. After configuring the ZigBee-chip-based communication module, tests were conducted to measure radiation level remotely: data were successfully transmitted in 10-meter and 100-meter distances, measuring radiation level in a remote condition. The communication module allows an environment where radiation level can be remotely measured in an economically beneficial way as it not only consumes less electricity but also costs less. By securing linearity of a radiation measuring device and by minimizing the device itself, it is possible to set up an environment where radiation can be measured in a reliable manner, and radiation level is monitored real-time.

Characteristic Evaluation of Optically Stimulated Luminescent Dosimeter (OSLD) for Dosimetry (광유도발광선량계(Optically Stimulated Luminescent Dosimeter)의 선량 특성에 관한 고찰)

  • Kim, Jeong-Mi;Jeon, Su-Dong;Back, Geum-Mun;Jo, Young-Pil;Yun, Hwa-Ryong;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.123-129
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate dosimetric characteristics of Optically stimulated luminescent dosimeters (OSLD) for dosimetry Materials and Methods: InLight/OSL $NanoDot^{TM}$ dosimeters was used including $Inlight^{TM}MicroStar$ Reader, Solid Water Phantom, and Linear accelerator ($TRYLOGY^{(R)}$) OSLDs were placed at a Dmax in a solid water phantom and were irradiated with 100 cGy of 6 MV X-rays. Most irradiations were carried out using an SSD set up 100 cm, $10{\times}10\;cm^2$ field and 300 MU/min. The time dependence were measured at 10 minute intervals. The dose dependence were measured from 50 cGy to 600 cGy. The energy dependence was measured for nominal photon beam energies of 6, 15 MV and electron beam energies of 4-20 MeV. The dose rate dependence were also measured for dose rates of 100-1,000 MU/min. Finally, the PDD was measured by OSLDs and Ion-chamber. Results: The reproducibility of OSLD according to the Time flow was evaluated within ${\pm}2.5%$. The result of Linearity of OSLD, the dose was increased linearly up to about the 300 cGy and increased supralinearly above the 300 cGy. Energy and dose rate dependence of the response of OSL detectors were evaluated within ${\pm}2%$ and ${\pm}3%$. $PDD_{10}$ and PDD20 which were measured by OSLD was 66.7%, 38.4% and $PDD_{10}$ and $PDD_{20}$ which were measured by Ion-chamber was 66.6%, 38.3% Conclusion: As a result of analyzing characteration of OSLD, OSLD was evaluated within ${\pm}3%$ according to the change of the time, enregy and dose rate. The $PDD_{10}$ and $PDD_{20}$ are measured by OSLD and ion-chamber were evaluated within 0.3%. The OSL response is linear with a dose in the range 50~300 cGy. It was possible to repeat measurement many times and progress of the measurement of reading is easy. So the stability of the system and linear dose response relationship make it a good for dosimetry.

  • PDF

What happens after IT adoption?: Role of habits, confirmation, and computer self-efficacy formed by the experiences of use (정보기술 수용 후 주관적 지각 형성: 사용 경험에서 형성된 습관, 기대일치, 자기효능감의 역할)

  • Kim, Yong-Young;Oh, Sang-Jo;Ahn, Joong-Ho;Jahng, Jung-Joo
    • Asia pacific journal of information systems
    • /
    • v.18 no.1
    • /
    • pp.25-51
    • /
    • 2008
  • Researchers have been continuously interested in the adoption of information technology (IT) since it is of great importance to the information systems success and it is also an important stage to the success. Adoption alone, however, does not ensure information systems success because it does not necessarily lead to achieving organizational or individual objectives. When an organization or an individual decide to adopt certain information technologies, they have objectives to accomplish by using those technologies. Adoption itself is not the ultimate goal. The period after adoption is when users continue to use IT and intended objectives can be accomplished. Therefore, continued IT use in the post-adoption period accounts more for the accomplishment of the objectives and thus information systems success. Previous studies also suggest that continued IT use in the post-adoption period is one of the important factors to improve long-term productivity. Despite the importance there are few empirical studies focusing on the user behavior of continued IT use in the post-adoption period. User behavior in the post-adoption period is different from that in the pre-adoption period. According to the technology acceptance model, which explains well about the IT adoption, users decide to adopt IT assessing the usefulness and the ease of use. After adoption, users are exposed to new experiences and they shape new beliefs different from the thoughts they had before. Users come to make decisions based on their experiences of IT use whether they will continue to use it or not. Most theories about the user behaviors in the pre-adoption period are limited in describing them after adoption since they do not consider user's experiences of using the adopted IT and the beliefs formed by those experiences. Therefore, in this study, we explore user's experiences and beliefs in the post-adoption period and examine how they affect user's intention to continue to use IT. Through deep literature reviews on the construction of subjective beliefs by experiences, we draw three meaningful constructs which theoretically have great impacts on the continued use of IT: perceived habit, confirmation, and computer self-efficacy. Then, we examine the role of the subjective beliefs on the cognitive/affective attitudes and intention to continue to use that IT. We set up a research model and conducted survey research. Since IT use implies interactions among a user, IT, and a task, we carefully selected the sample of users using same/similar IT to perform same/similar tasks, to exclude unwanted influences of other factors than subjective beliefs on the IT use. We also considered that the sample of users were able to make decisions to continue to use IT volitionally or at least quasi-volitionally. For each construct, we used measurement items recognized for reliability and widely used in the previous research. We slightly modified some items proper to the research context and a pilot test was carried out for forty users of a portal service in a university. We performed a full-scale survey after verifying the reliability of the measurement. The results show that the intention to continue to use IT is strongly influenced by cognitive/affective attitudes, perceived habits, and computer self-efficacy. Confirmation affects the intention to continue indirectly through cognitive/affective attitudes. All the constructs representing the subjective beliefs built by the experiences of IT use have direct and/or indirect impacts on the intention of users. The results also show that the attitudes in the post-adoption period are formed, at least partly, by the experiences of IT use and newly shaped beliefs after adoption. The findings suggest that subjective beliefs built by the experiences have deep impacts on the continued use. The results of the study signify that while experiencing IT in the post-adoption period users form new beliefs, attitudes, and intentions which may be different from those of the pre-adoption period. The results of this study partly demonstrate that the beliefs shaped by the behaviors, those are the experiences of IT use, influence users' attitudes and intention. The results also suggest that behaviors (experiences) also change attitudes while attitudes shape behaviors. If we combine the findings of this study with the results of the previous research on IT adoption, we can propose a cycle of IT adoption and use where behavior shapes attitude, the attitude forms new behavior, and that behavior shapes new attitude. Different from the previous research, the study focused on the user experience after IT adoption and empirically demonstrated the strong influence of the subjective beliefs formed in the post-adoption period on the continued use. This partly confirms the differences between attitudes in the pre-adoption and in the post-adoption period. Users continuously change their attitudes and intentions while experiencing (using) IT. Therefore, to make users adopt IT and to make them use IT after adoption is a different problem. To encourage users to use IT after adoption, experiential variables such as perceived habit, confirmation, and computer self-efficacy should be managed properly.

MEASUREMENT OF PULPAL BLOOD FLOW USING A LASER DOPPLER FLOWMETER (Laser Doppler flowmeter를 이용한 치수혈류 측정)

  • Ban, Tae-Whan;Lee, Jae-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.560-569
    • /
    • 1999
  • Blood supply rather than nerve supply implies pulp vitality. To evaluate pulp vitality clinically, electric pulp test and thermal test which are based on sensory nerve response have been used in addition to many auxiliary data such as past dental history, visual inspection, radiographic examination, percussion, palpation and transillumination test. However, reactivity of the nerves to the stimulation is not synonymous with normalcy. Therefore measurement of pulpal blood flow using a laser Doppler flowmeter became a new trial to test the pulp vitality. The purpose of the present study was to evaluate normal pulpal blood flow level of maxillary teeth in adult to provide a guideline in determining the vitality of dental pulp. Pulpal blood flow was measured in maxillary central and lateral incisors, canines, first and second premolars and first molars of seventy nine adults of 22 - 30 years old using a laser Doppler flowmeter (PeriFlux 4001, Perimed Co., Stockholm, Sweden, 780 nm infrared laser, 1mW). For directly-made splints, silicone rubber impressions were taken directly from the mouth. For indirectly-made splints, alginate impressions were taken from the mouth and stone cast were made. After making depressions on the buccal surfaces of the cast teeth to indicate the hole positions, second impressions with vinyl polysyloxane putty were taken from the cast. Holes for the laser probes were made at the putty impressions 4mm above the gingival level. Laser probe (PF416 dental probe, 1.5mm) was inserted in the prepared hole and the splint was set in the mouth. After 10 minutes of patient relaxing, pulpal blood flow was recorded for 5 minutes on each tooth. The recorded flow was saved in the computer and calculated with a software 'Perisoft' version 5.1. Pulpal blood flow was also recorded in six teeth of five individuals with no response to electric pulp test and cold test, with periapical radiolucency, or with history of root canal treatment to compare with nonvital teeth. The difference between the mean flow values of each group of teeth were analyzed using one-way ANOVA and Duncan's Multiple Range test. The results were as follows: 1. The average pulpal blood flow values of all the tested teeth of each location were between 9 - 16 Perfusion Unit. Pulpal blood flow value was highest in maxillary lateral incisors, followed by first premolars, second premolars, canines, central incisors, and then first molars (p<0.01). 2. In six anterior teeth, indirectly-made splint group showed higher pulpal blood flow values than directly-made splint group (p<0.01). In posterior teeth, however, there was no significant flow value difference between directly-made splint group and indirectly-made splint one (p>0.05). 3. Teeth with vital pulps showed higher signal values than teeth with nonvital pulps (p<0.01), and the flow photographs showed heartbeat-synchronous fluctuations and vasomotions, while those were absent in non vital tooth.

  • PDF

The Research to Correct Overestimation in TOF-MRA for Severity of Cerebrovascular Stenosis (3D-SPACE T2 기법에 의한 TOF-MRA검사 시 발생하는 혈관 내 협착 정도의 측정 오류 개선에 관한 연구)

  • Han, Yong Su;Kim, Ho Chul;Lee, Dong Young;Lee, Su Cheol;Ha, Seung Han;Kim, Min Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.180-188
    • /
    • 2014
  • It is very important accurate diagnosis and quick treatment in cerebrovascular disease, i.e. stenosis or occlusion that could be caused by risk factors such as poor dietary habits, insufficient exercise, and obesity. Time-of-flight magnetic resonance angiography (TOF-MRA), it is well known as diagnostic method without using contrast agent for cerebrovascular disease, is the most representative and reliable technique. Nevertheless, it still has measurement errors (also known as overestimation) for length of stenosis and area of occlusion in celebral infarction that is built by accumulation and rupture of plaques generated by hemodynamic turbulence. The purpose of this study is to show clinical trial feasibility for 3D-SPACE T2, which is improved by using signal attenuation effects of fluid velocity, in diagnosis of cerebrovascular disease. To model angiostenosis, strictures of different proportions (40%, 50%, 60%, and 70%) and virtual blood stream (normal saline) of different velocities (0.19 ml/sec, 1.5 ml/sec, 2.1 ml/sec, and 2.6 ml/sec) by using dialysis were made. Cross-examinations were performed for 3D-SPACE T2 and TOF-MRA (16 times each). The accuracy of measurement for length of stenosis was compared in all experimental conditions. 3D-SPACE 2T has superiority in terms of accuracy for measurements of the length of stenosis, compared with TOF-MRA. Also, it is robust in fast blood stream and large stenosis than TOF-MRA. 3D-SPACE 2T will be promising technique to increase diagnosis accuracy in narrow complex lesions as like two cerebral small vessels with stenosis, created by hemodynamic turbulence.

An Analytical Study of the Relationship between Climacteric Symptoms and the Stress of Life Events (갱년기 증상과 생활스트레스의 관계에 관한 연구)

  • Im Eun-Ok
    • Journal of Korean Public Health Nursing
    • /
    • v.8 no.2
    • /
    • pp.1-34
    • /
    • 1994
  • This study has been done in order to analyze the relationship between climacteric symptoms and the stress of life events. For the purpose of this study. objectives set up were as followings. : 1. Climacteric symptoms complained by middle aged women are studied. 2. The stress of life events experienced by middle aged women is studied. 3. The relationship between climacteric symptoms and the stress of life events is studied. 4. The relationship between climacteric symptoms and general characteristics is studied. and the relationship between the stress of life events and general characteristics is also studied. The sample size of this study was 462 cases. The subjects were middle-aged women. who were from 40 to 60 years old and resided in Seoul. Data were collected by using questionnaires which consisted of 122 questions from Jan. 1 to Feb. 7 in 1992. The questionnaires include questions about general characteristics. climacteric symptoms and life events. The measurement scales for this study were adopted from the climacteric symptoms scale developed by Chi. Sung-Ai and the measurement scale of stress related to life events devised by Lee. Pyoung Sook. The analysis of data collected was done by using SPSS-pc package. Firstly. general characteristics were analyzed by using descriptive statistical methods. Secondly. climacteric symptoms were analyzed by using descriptive statistical methods. the analysis of variance and correlation analysis. Thirdly. the stress of life events was studied by using descriptive statistical methods. the analysis of variance. and tests of independence. The results of this study are as followings. 1. General characteristics of the respondents are as followings: The average age is 49. 13. and the age group from 46 to 50 has $30.5\%$ in the respondents. Christianity is the major religion $(42.6\%)$. and the respondents with a high school diploma are $(43.1\%)$ of the respondents. $60\%$ of all respondents are housewives. and $90.5\%$ are married. The average number of children is 2.71. and the average number of family is 4.24 Monthly income of $39.1\%$ of the respondents is from l,010,000 Won to 2,000,000 Won. The premenopausal group is $4.9\%$. and $45.5\%$ of all respondents are satisfied with marrital life. $43.3\%$ of all feel happy. and $13.9\%$ feel economic frustration. $27.9\%$ of respondents are satisfied with sexual life. and $45\%$ of all report that the amount of recreational activities are more needed. 2. The average score of climacteric symptoms is 1. 8461 (The maximum score is 5.0). The symptoms complained frequently are nervousness. muscle-ache. fatigue. headache and knee-ache. Climacteric symptoms are significantly different in menopausal states. age groups. the number of children, marrital satisfaction. the feeling of life. self-reported health states and sexual satisfaction. 3. The life events occurred frequently were 'discord with husband', 'children's important exams', 'separation from husband related to works' and 'vacation'. When life events are analyzed by factors. the most frequently mentioned factor is 'marrital life'. The stress of life events is significantly different in a few general characteristics (age. the number of children, the number of family, monthly income, menopausal status, the feeling of life. self-reported health states, economic satisfaction). 4. The score of climacteric symptoms complained is significantly different according to the stress of life events (p<0.051, Especially, the difference is the widest in psychological symptoms according to the factor of 'couple. marrital life' among stressful life events. In Summary, climacteric symptoms complained by middle-aged women are related to the amount of the stress of life events. Whether life events are positive of negative is not important. Yet. climacteric symptoms and stressful life events are deeply related to general characteristics. so we can not insist strongly that one be directly related to the other.

  • PDF

STUDY ON THE GROWTH OF THE MANDIBLE USING WIDE OPEN LATERAL CEPHALOGRAM (Wide open lateral cephalogram을 이용한 하악골 성장에 관한 연구)

  • Moon, Sung-Uk;Park, Young-Guk;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.39-50
    • /
    • 2001
  • In proceeding with orthodontic treatment, the prediction for the shape, growth rate and growth direction of mandible plays a major role to set up the treatment plan and determine its period and prognosis. Various approaches being made so far have shown that the linear and angular measurement using lateral cephalograms are relatively accurate to estimate them. This study was purposed to find the shape of mandible more clearly by preventing the overlap of the Condyle head area which appears in lateral cephalogram, and to estimate its growth rate by comparing the growth quantity and ratio via lateral area measurement. This experimental was performed against 40 patients total, of which Class I of 14, Class II of 9 and Class III of 17 consist. Wide open lateral cephalograms of 40 patients were taken over average period of 4 Year 3 Months, then the linear and angular measurements were carried out with 11 itemized lists. Autocad Rl4 application program was utilized to draw their appearance, measure and compare their lateral area. As a result of study, conclusions were made as follows; 1. Mandibular body length (gonion-menton) tended to increase in order of CIII, CI and CII, and Mandibular body length of CIII group had a tendency to grow twice faster than that of CII group. 2. In lateral items such as Go-Me, A-Cd, B-Cp, E-F and G-H, CIII showed a significant increase on the year-average quantity and rate of the growth, and especially apparent difference was observed in CIII group rather than CII group. 3. For the 4 Year 3 Months period, the year-average growth quantity of lateral area of the mandible was $1.0cm^2$ for Class I, $0.8cm^2$ for Class II and $1.4cm^2$ for Class III, which corresponds to $11.9\%,\;11.8\%\;and\;20.3\%$ of growth ratio respectively. Thus, growth ratio almost 2 times more than other groups was observed in group CIII while growth ratio between group CI and CII has little difference. 4. Considering the results as above, it can be proposed that the difference in size of the mandible between groups is caused by the difference in the growth rate and growth quantity of the mandible, which generated in the middle of growth, rather than the difference in size of congenital Jaw-bone.

  • PDF

Transmission Dose Estimation Algorithm for in vivo Dosimertry (투과선량을 이용한 생체내 (in vivo) 선량측정을 위한 알고리즘)

  • Yun, Hyong-Geun;Chie, Eui-Kyu;Huh, Soon-Nyung;Lee, Hyoung-Koo;Woo, Hong-Gyun;Shin, Kyo-Chul;Kim, Si-Yong;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.147-154
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry of QA purpose. The objective of this study is to develope an algorithm for estimation of tumor dose using measured transmission dose for open radiation field. Materials and Methods : Transmission dose was measured with various field size (FS), phantom thickness (Tp), and phantom chamber distance (PCD) with a acrylic phantom for 6 MV and 10 MV X-ray. Source to chamber distance (SCD) was set to 150 cm. Measurement was conducted with a 0.6 co Farmer type ion chamber. Using measured data and regression analysis, an algorithm was developed lot estimation of expected reading of transmission dose. Accuracy of the algorithm was tested with flat solid phantom with various settings. Results : The algorithm consisted of quadratic function of log(A/P) (where A/P is area-perimeter ratio) and tertiary function of PCD. The algorithm could estimate dose with very high accuracy for open square field, with errors within ${\pm}0.5%$. For elongated radiation field, the errors were limited to ${\pm}1.0%$. Conclusion : The developed algorithm can accurately estimate the transmission dose in open radiation fields with various treatment settings.