• Title/Summary/Keyword: Measurement Instrument Validation

Search Result 40, Processing Time 0.022 seconds

Development of an Portable Urine Glucose Monitoring System (휴대용 뇨당 측정 시스템의 개발)

  • 박호동;이경중;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.397-403
    • /
    • 2002
  • Urine glucose monitoring system is a self-monitoring system that display the glucose level by non-invasive measurement method. In this paper, We developed a noninvasive urine glucose monitoring system that improved defects of urine glucose measurement with a colorimeter method and invasive blood glucose measurement method. This system consist of bio-chemical sensor for urine glucose measurements, signal detecting part, digital and signal analysis part, display part and power supplying part. The developed bio-chemical sensor for the measurement of urine glucose has good reproducibility, convenience of handing and can be mass-produced with cheap price. To evaluate the performance of the developed system, We performed the evaluation of confidence about the detection of glucose level by a comparison between a standard instrument in measuring glucose level and the developed system using standard glucose solutions mixed with urine. Standard error was 2.85282 from the evaluation of confidence based on regression analysis. Also, In analysis of S.D(standard deviation) and C.V(coefficient of validation) that are important parameters to evaluate system using bio-chemical sensor, S.D was 10% which falls under clinically valid value, 15%, and C.V was under 5%. Consequently from the above results, compared to blood glucose measurement, the system performance is satisfactory.

Conceptualizing 5G's of Green Marketing for Retail Consumers and Validating the Measurement Model Through a Pilot Study

  • ANSARI, Hafiz Waqas Ahmed;FAUZI, Waida Irani Mohd;SALIMON, Maruf Gbadebo
    • Journal of Distribution Science
    • /
    • v.20 no.4
    • /
    • pp.33-50
    • /
    • 2022
  • Purpose: This pilot study aims to conceptualize a new green marketing mix for retail consumers based on Stimulus-Organism-Response (SOR) model. Moreover, it also aims to conceptualize a testable research model of new green marketing mix with consumers' green purchasing behavior, and to validate the measurement model with traditional as well as modern suggested validating techniques. Research design, data and methodology: A pilot test data from 75 respondents of retail buyers of energy-efficient electric appliances in Pakistan were tested for the confirmatory factor analysis (CFA) by examining a measurement model of the construct through different validation techniques (like Composite Reliability, McDonald's Omega (ω), rho (ρA), HTMT, etc.) as heretofore these scales were not validated through these modern methods. Results: The results revealed that the instrument has a certain degree of reliability and validity through different validating techniques. All the measurement items reach the suggested threshold values. Conclusions: Therefore, this study conceptualized an integrated framework of all the three stakeholders of the environment (government, companies, and public or consumers) to achieve environmental sustainability. Hence, future studies can extend these findings and conduct a full-scale study to establish an empirical relationship between the 5G's of green marketing for retailing businesses and consumers' green purchase behavior.

An Empirical Study of the Clinically Reportable Range in Clinical Chemistry (임상보고 가능범위의 실증적 연구)

  • Chang, Sang-Wu;Lee, Sang-Gon;Choi, Ho-Seong;Song, Eun-Young;Park, Yong-Won;Lee, In-Ae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.1
    • /
    • pp.31-36
    • /
    • 2007
  • The purpose of the clinically reportable range (CRR) in clinical chemistry is to estimate linearity in working range. The reportable range includes all results that may be reliably reported, and embraces two types of ranges: the analytical measurement range (AMR) is the range of analyte values that a method can directly measure on the specimen without any dilution, concentration, or other pretreatment not part of the usual assay process. CAP and JCAHO require linearity on analyzers every six months. The clinically reportable range is the range of analyte values that a method can measure, allowing for specimen dilution, concentration, or other pretreatment used to extend the direct analytical measurement range. The AMR cannot exceed the manufacturer's limits. Establishing AMR is easily accomplished with Calibration Verification Assessment and experimental Linearity. For example: The manufacturer states that the limits of the AST on their instrument are 0-1100. The lowest level that could be verified is 2. The upper level is 1241. The verified AMR of the instrument is 2-1241. The lower limit of the range is 2, because that is the lowest level that could be verified by the laboratory. The laboratory could not use the manufacturer's lower limit of 2 because they have not proven that the instrument values below 2 are valid. The upper limit of the range is 1241, because although the lab has shown that the instrument is linear to 1241, the manufacturer does not make that claim. The laboratory needs to demonstrate the accuracy and precision of the analyzer, as well the validation of the patient AMR. Linearity requirements have been eliminated from the CLIA regulations and from the CAP inspection criteria, however, many inspectors continue to feel that linearity studies are a part of good lab practice and should be encouraged. If a lab chooses to continue linearity studies, these studies must fully comply with the calibration/calibration verification requirements of CLIA and/or CAP. The results of lower limit and upper limit of clinically reportable range were total protein (2.1 - 79.9), albumin (1.3 - 39), total bilirubin (0.2 - 106.2), alkaline phosphatase (13 - 6928.2), aspartate aminotransferase (24 - 7446), alanine aminotransferase (13 - 6724.2), gamma glutamyl transpeptidase (16.64 - 9904.2), creatine kinase (15.26 - 4723.8), lactate dehydrogenase (127.66 - 13231.8), creatinine (0.4 - 129.6), blood urea nitrogen (8.67 - 925.8), uric acid (1.6 - 151.2), total cholesterol (48.52 - 3162), triglycerides (36.91 - 3367.8), glucose (31 - 4218), amylase (21 - 6694.2), calcium (3.1 - 118.2), inorganic phosphorus (1.11 - 108), HDL (11.74 - 666), NA (58.3 - 1800), K (1.0 - 69.6), CL (38 - 1230).

  • PDF

Development and Validation of an Instrument to Measure High School Students' Disaster Safety Awareness

  • Lee, Soon-Beom;Kong, Ha-Sung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.4
    • /
    • pp.154-168
    • /
    • 2021
  • The purpose of this study is to develop and validate the disaster safety awareness scale for high school students. For this purpose, the previously developed disaster safety awareness scale and related prior research was analyzed. Questionnaire data was collected from March 22 to May 25, 2021 from 1054 students (male: 569, female: 485) in the first, second, and third grades of 5 high schools in 3 cities. Through the process of revising, supplementing, and reviewing the items extracted through preliminary research and preliminary test together with experts and students, a final disaster safety awareness scale consisting of 24 items was developed. This scale consists of four sub-factors: 'disaster prevention', 'disaster response A', 'disaster response B', and 'disaster recovery'. Good reliability and validity were secured through exploratory and confirmatory analyses. The significance of this study is that it laid a basic and objective foundation for high school students' disaster safety awareness research by developing a validated scale in a situation where the development of disaster safety awareness scales for high school students was still insufficient. It can be used as useful data for fire safety education as well as a psychological measurement tool for fostering fire safety awareness.

Accuracy evaluation of microwave water surface current meter for measurement angles in middle flow condition (전자파표면유속계의 측정 각도에 따른 평수기 유속 측정 정확도 분석)

  • Son, Geunsoo;Kim, Dongsu;Kim, Kyungdong;Kim, Jongmin
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.1
    • /
    • pp.15-27
    • /
    • 2020
  • Streamflow discharge as a fundamental riverine quantity plays a crucial role in water resources management, thereby requiring accurate in-situ measurement. Recent advances in instrumentations for the streamflow discharge measurement has complemented or substituted classical devices and methods. Among various potential methods, surface current meter using microwave has increasingly begun to be applied not only for flood but also normal flow discharge measurement, remotely and safely enabling practitioners to measure flow velocity postulating indirect contact. With minimized field preparedness, this method facilitated and eased flood discharge measurement in the difficult in-situ conditions such as extreme flood in active ways emitting 24.125 GHz microwave without relying on natural lights. In South Korea, a rectangular shaped instrument named with Microwave Water Surface Current Meter (MWSCM) has been developed and commercially released around 2010, in which domestic agencies charging on streamflow observation shed lights on this approach regarding it as a potential substitute. Considering this brand-new device highlighted for efficient flow measurement, however, there has been few noticeable efforts in systematic and comprehensive evaluation of its performance in various measurement and riverine conditions that lead to lack in imminent and widely spreading usages in practices. This study attempted to evaluate the MWSCM in terms of instrumen's monitoring configuration particularly regarding tilt and yaw angle. In the middle of pointing the measurement spot in a given cross-section, the observation campaign inevitably poses accuracy issues related with different tilt and yaw angles of the instrument, which can be a conventionally major source of errors for this type of instrument. Focusing on the perspective of instrument configuration, the instrument was tested in a controlled outdoor river channel located in KICT River Experiment Center with a fixed flow condition of around 1 m/s flow speed with steady flow supply, 6 m of channel width, and less than 1 m of shallow flow depth, where the detailed velocity measurements with SonTek micro-ADV was used for validation. As results, less than 15 degree in tilting angle generated much higher deviation, and higher yawing angle proportionally increased coefficient of variance. Yaw angles affected accuracy in terms of measurement area.

An Item Characteristic Analysis of Competency Inventory for Designer via Generalized Partial Credit Mode (일반화부분점수 모형에 의한 디자인역량 검사 특성 분석)

  • LEE, Dae-Yong
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.6
    • /
    • pp.1546-1555
    • /
    • 2015
  • This study was performed to analyze the item characteristics of competency inventory for designer (CID), which Gil (2011) developed for measurement of design competency. To accomplish the purpose of this study, general partial credit (GPC) model based on polytomous item response theory was applied. The findings were as follows: First, CID is a reliable instrument for measuring design competency. Second, most items of CID have low item discrimination and average item difficulty according to the GPC model. Especially, there are some problems to have low item discrimination in view of validation. To improve the goodness of CID, we will need to examine why CID has low item discrimination.

Development and Validation of a Scale for the Measurement of Early Childhood Teacher's Competence in Unification Education (유아교사의 통일교육역량에 대한 평가척도 개발 및 타당화 연구)

  • Jung, Dae Hyun;Kwak, Youn Mi
    • Korean Journal of Human Ecology
    • /
    • v.21 no.5
    • /
    • pp.819-835
    • /
    • 2012
  • The purpose of this study was to develop and test the validity of an assessment scale for determining the competency of early childhood teachers practicing unification education. For this purpose, an evaluation scale was constructed and then tested for reliability and validity. Participants for this study included 266 early childhood teachers in the unification education field. In order to the measure reliability and validity of this scale, Exploratory Factor Analysis and Confirmatory Factor Analysis were conducted with SPSS 18.0 and AMOS. The result of this study identified four principal factors: 1) Instruction skills, 2) Evaluation, 3) Attitude, and 4) Knowledge. The results of this study supported the scale's reliability and legitimacy as a valid instrument for the evaluation of early childhood teacher's competence in unification education.

A Study on the Calibration Techniques for Thermopile Pyranometer (일사계 교정기법에 관한 연구)

  • Jo, Dok-Ki;Kang, Yong-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.161-166
    • /
    • 2008
  • The major purpose of this paper is to develop an uncertainty estimate for the calibration of thermopile instruments used to measure solar radiation parameters. We briefly describe the solar radiation parameters most often measured, instrumentation, reference standards, and calibration techniques. The bulk of the paper describes elemental sources of error and their magnitude. We then apply a standard error analysis methodology to combine these elemental error estimates into a statement of total uncertainty for the instrument calibration factor. Our results allow one to evaluate the accuracy of a radiometric measurement using thermopile instrumentation in the light of the application, such as engineering test evaluation or for validation of theoretical models.

  • PDF

A Study on the Uncertainty Analysis for Thermopile Pyranometer Calibrations (일사계 교정을 위한 불확실성 분석에 관한 연구)

  • Jo, D.K.;Chun, I.S.;Jeon, M.S.;Kang, Y.H.;Auh, C.M.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.3
    • /
    • pp.25-32
    • /
    • 2001
  • The major purpose of this paper is to develop an uncertainty estimate for the calibration of thermopile instruments used to measure solar radiation parameters. We briefly describe the solar radiation parameters most often measured, instrumentation, reference standards, and calibration techniques. The bulk of the paper describes elemental sources of error and their magnitude. We then apply a standard error analysis methodology to combine these elemental error estimates into a statement of total uncertainty for the instrument calibration factor. Our results allow one to evaluate the accuracy of a radiometric measurement using thermopile instrumentation in the light of the application, such as engineering test evaluation or for validation of theoretical models.

  • PDF

Assessing Content Validity of Environmental Performance Indicators for Construction Sites (시공단계 환경성능평가를 위한 평가항목의 내용타당성 검토)

  • Kang, Goune;Lee, Sanggyu;Lee, Myungdo;Cho, Hunhee;Kang, Kyung-in
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.7-9
    • /
    • 2013
  • An assessment tool's validity is crucial because its scores are used as basis of decision making. This study assessed the content validity of the indicators for environmental assessment of construction activities. Pool of candidate indicators were constituted from the literature review, and CVR(Content Validity Rate) approach was adopted to investigate the content validity. As a result, 14 indicators are effective and five of them are content valid and retained from the pool.

  • PDF