• Title/Summary/Keyword: Measurement Error

Search Result 3,900, Processing Time 0.03 seconds

Studies on Development of Breeding Technique to Increase HanWoo(Bos taurus coreanae) : II. Early Pregnancy Diagnosis Incidence of Reproductive Disorders (한우의 신속한 증식을 위한 번식기술 개발에 관한 연구 II. 조기 임신 진단법 및 번식장애 분포에 관한 연구)

  • Jang, G.;Son, C. H.;Lee, E. S.;Ryu, I. S.;Lee, K. N.;Lee, D. W.;Oh, M. H.;Oh, S. J.;Jung, K. K.;Choi, S. Y.;Roh, K. J.;Kim, S. C.;Lee, B. C.;Hwang, W. S.
    • Journal of Embryo Transfer
    • /
    • v.16 no.1
    • /
    • pp.7-14
    • /
    • 2001
  • The aims of these study were to diagnose early pregnancy and reproductive disorders by using progesterone concentration and ultrasonography. The measurement of blood progesterone (P$_4$) concentration was conducted to diagnose pregnancy and to detect corpus luteum (CL) or evaluate disorder of CLs. As a result, the incidence rates of reproductive disorders were as follows : SH and EED (41.9%), inacitve ovaries (32.6%), follicullar cyst (9.3%), PCL (7.0%), endometritis (4.7%), pyometra (2.3%) and luteal cyst (2.3%). 61 Cows having P$_4$concentration 1.0 ng/ml(at the insemination) were increased to 1.0 ng/ml $\geq$ 6day after insemination. 50 cows among 61 cows were diagnosed pregnant. 8 cows among 13 HanWoos having P$_4$concentration 1.0 ng/ml at the insemination and 1.0 ng/mnl 6 day after insemination had non-ovulatory estrus and the others had P$_4$concentration 1.0 ng/ml at the insemination and 1.0 ng/ml $\geq$ 6 day after insemination, which was the error of estrus detection. All 13 cows were diagnosed non-pregnant. 47 cows diagnosed pregnant after insemination of P$_4$concentration 3.0 ng/ml were examined by ultrasonography at 30 day post-insemination. As a result, 41 cows were diagnosed pregnant (87.2%) but 14 cows having P$_4$concentration 3.0 ng/ml at 21 day after insemination was diagnosed to non-pregnancy. Calving intervals by surveying 100 cows were as follows 11~12 months (20%), 12~13 months (36%), 13~14 months (19%), 14 months $\geq$ (25%), respectively. In conclusion, hormone and ultrasonography help to detect reproductive disorders exactly and diagnose early pregnancy. This study suggest that diagnosis of early pregnancy and reproductive disorder by blood P$_4$concentration and ultrasonography improve reproduction management of HanWoo.

  • PDF

Quality Control on the BOD, COD, TN, TP of Water Quality Pollutant (수질오염물질 BOD, COD, TN, TP의 정도관리(I))

  • Park, Sun-Ku;Kim, Tae-Seung;Ryu, Jae-Kyun
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.312-317
    • /
    • 1999
  • Quality control was carried out the three analytes, BOD, COD, TN, TP of high and low concentration for thirteen laboratories. Evaluation values of Quality control was determined from average value which were made by six times test, repeatedly and periodically. This value had not only error ratio of within 5% from prepared sample value but also high precision of standard deviation, 0.44 (BOD, low concentration), 2.15 (BOD, high concentration), 0.12 (COD, low concentration), 1.63 (COD, high concentration), 0.35 (TN, low concentration), 1.99 (TN, high concentration), 0.05 (TP, low concentration), 0.14 (TP, high concentration). Upper (Lower) Warning Limit (ULWL) and Upper (Lower) Acceptance Limit (ULAL) values made from quality control chart. Three (5.30, 9.70, 5.30 mg/L) and five laboratories were over ULAL value in low and high BOD concentration, respectively. Two (41.00, 30.60 mg/L) and four laboratories were over ULAL value in low and high COD concentration, respectively. while, other eleven laboratories appeared reliable data. One laboratory (0.70 mg/L) was over ULAL at low TN concentration, while other eleven laboratories had reliable values. In case of high TN concentration, eleven laboratories were over ULAL value, it should be focuced for improvement of reliability about measurement and analysis of TN. Four (1.14, 0.45, 0.64, 1.49mg/L) and seven laboratories were over ULAL in low and high TP concentration, respectively.

  • PDF

Reliability improvement of an ion-measuring system using FET sensor array (FET 센서 어레이를 이용한 이온 측정 시스템의 신뢰도 개선)

  • Choi, Jung-Tae;Lee, Seung-Hyup;Kim, Young-Jin;Lee, Young-Chul;Cho, Byung-Woog;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.341-346
    • /
    • 1999
  • In general cases, compared with glass electrode, FET type electrolyte sensors have many advantages. But the drift, memory effect and the poor reproducibility of the FET type electrolyte sensor cause the decrease of the reliability in the measurement system. To improve the reliability, an ion-measuring system using FET type electrolyte sensor array with 8 sensors has been developed. Developed system employed the electronic switchs to connect a signal detecting circuit with 8 sensor array and the system can measure ion concentration of 4 different type electrolyte($H^+$, $Na^+$, $K^+$, $Ca^{2+}$). The signal processing algorithm with insertion sorting method was adopted to enhance the reliability. We measured 3 different ion($H^+$, $Na^+$, $K^+$) to evaluate the performance of developed system. The results show that the designed signal processing algorithm can reduce the error range in comparison with a simple arithmetic mean and the developed system has a good reliability over the previous single channel sensor system.

  • PDF

An Analysis of Vertical Position Accuracy for the Three-Dimensional Spatial Data Object Utilizing the Public Information (공공데이터를 활용한 3차원 공간정보 객체의 수직위치 정확도 분석)

  • Kim, Jeong Taek;Yi, Su Hyun;Kim, Jong Il;Bae, Sang Won
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.3
    • /
    • pp.137-143
    • /
    • 2014
  • Recently, as new paradigm for government operation called government 3.0, government is actively operating policy opening and sharing public data. In addition, the Ministry of Land are operating an open platform integrated map service (the VWorld) which provides a variety of video contents such as the country's national spatial information, traffic information and three-dimensional building for the public. According to W3C Foundation's Open Data Status Report(2013), our country has the evaluated results that the part of the government's policy support and planning is good while the part of the data management is vulnerable. So our country needs the quality improvement for the data management. In addition, a digital aerial photograph image data is required to be up-to-date for the three-dimensional spatial object data. In this paper, we present the method for enhancement of the accuracy of vertical position and for maintainment of up-to-date vertical position. Our methods evaluate the data quality and analyze the cause of error of measurement utilizing the national standard quality assessment method. The result of research shows that the accuracy of vertical position is improved if the height of the building captain is adjusted by the quality assessment values and a three-dimensional model has up-to-date data if reconstruction and extension information of construction register is utilized.

Automation of Bio-Industrial Process Via Tele-Task Command(I) -identification and 3D coordinate extraction of object- (원격작업 지시를 이용한 생물산업공정의 생력화 (I) -대상체 인식 및 3차원 좌표 추출-)

  • Kim, S. C.;Choi, D. Y.;Hwang, H.
    • Journal of Biosystems Engineering
    • /
    • v.26 no.1
    • /
    • pp.21-28
    • /
    • 2001
  • Major deficiencies of current automation scheme including various robots for bioproduction include the lack of task adaptability and real time processing, low job performance for diverse tasks, and the lack of robustness of take results, high system cost, failure of the credit from the operator, and so on. This paper proposed a scheme that could solve the current limitation of task abilities of conventional computer controlled automatic system. The proposed scheme is the man-machine hybrid automation via tele-operation which can handle various bioproduction processes. And it was classified into two categories. One category was the efficient task sharing between operator and CCM(computer controlled machine). The other was the efficient interface between operator and CCM. To realize the proposed concept, task of the object identification and extraction of 3D coordinate of an object was selected. 3D coordinate information was obtained from camera calibration using camera as a measurement device. Two stereo images were obtained by moving a camera certain distance in horizontal direction normal to focal axis and by acquiring two images at different locations. Transformation matrix for camera calibration was obtained via least square error approach using specified 6 known pairs of data points in 2D image and 3D world space. 3D world coordinate was obtained from two sets of image pixel coordinates of both camera images with calibrated transformation matrix. As an interface system between operator and CCM, a touch pad screen mounted on the monitor and remotely captured imaging system were used. Object indication was done by the operator’s finger touch to the captured image using the touch pad screen. A certain size of local image processing area was specified after the touch was made. And image processing was performed with the specified local area to extract desired features of the object. An MS Windows based interface software was developed using Visual C++6.0. The software was developed with four modules such as remote image acquisiton module, task command module, local image processing module and 3D coordinate extraction module. Proposed scheme shoed the feasibility of real time processing, robust and precise object identification, and adaptability of various job and environments though selected sample tasks.

  • PDF

Numerical Simulation of Three Dimensional Fluid Flow Phenomena in Cylindrical Submerged Flat Membrane Bioreactor for Aeration Rate (원통 침지형 평막 생물반응기 내 산기량에 따른 3차원 유동현상에 관한 수치모사)

  • Kim, Dae Chun;Chung, Kun Yong
    • Applied Chemistry for Engineering
    • /
    • v.25 no.4
    • /
    • pp.401-408
    • /
    • 2014
  • In membrane bio-reactor (MBR), the aeration control is one of the important independent variables to decrease fouling and to save energy with shear stress change on the membrane surface. The paper was carried out for numerical simulation of 3-dimensional fluid flow phenomena of the cylindrical bioreactor with submerged flat membranes equipped in the center and supplied the air from the bottom by using the COMSOL program. The viscosity and temperature of solution were assumed to be constant, and the specific air demand based on permeate volume ($SAD_p$) defined as scouring air per permeate rates was used as a variable. The calculated CFD velocities were compared with those of the velocity meter measurement and video image analysis, respectively. The results were good agreement each other within 11% error. For fluid flow in the reactor the liquid velocity increased rapidly between the air diffuser and membrane module, but the velocity decreased during flowing of the membrane module. Also, the velocity increased as it was near from the reactor wall to the central axis. The calculated shear stress on the membrane surface showed the highest value at the center part of the module bottom side and increased as aeration rate increased. Especially, the wall shear stress increased dramatically as the aeration rate increased from 0.15 to 0.25 L/min.

Accuracy Analysis of 3D Position of Close-range Photogrammetry Using Direct Linear Transformation and Self-calibration Bundle Adjustment with Additional Parameters (DLT와 부가변수에 의한 광속조정법을 활용한 근접사진측량의 3차원 위치정확도 분석)

  • Kim, Hyuk Gil;Hwang, Jin Sang;Yun, Hong Sic
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.2
    • /
    • pp.27-38
    • /
    • 2015
  • In this study, the 3D position coordinates were calculated for the targets using DLT and self-calibration bundle adjustment with additional parameters in close-range photogrammetry. And then, the accuracy of the results were analysed. For this purpose, the results of camera calibration and orientation parameters were calculated for each images by performing reference surveying using total station though the composition of experimental conditions attached numerous targets. To analyze the accuracy, 3D position coordinates were calculated for targets that has been identically selected and compared with the reference coordinates obtained from a total station. For the image coordinate measurement of the stereo images, we performed the ellipse fitting procedure for measuring the center point of the circular target. And then, the results were utilized for the image coordinate for targets. As a results from experiments, position coordinates calculated by the stereo images-based photogrammetry have resulted out the deviation of less than an average 4mm within the maximum error range of less than about 1cm. From this result, it is expected that the stereo images-based photogrammetry would be used to field of various close-range photogrammetry required for precise accuracy.

Lateral Cephalometric Measurements of Class I Malocclusion Patients with Uncertainty (불확도를 고려한 Class I 부정교합 환자의 측방두부방사선영상 계측값)

  • Lee, Ji Min;Song, Ji-Soo;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Hojae;Cho, Hyo-Min;Shin, Teo Jeon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.1
    • /
    • pp.65-74
    • /
    • 2018
  • The aim of this study was to obtain the traceability of the software used to analyze lateral cephalometry and to calculate the uncertainty of the measurements. Furthermore, this study aimed to provide a basis for obtaining standard references for measurement values for orthodontic treatment in children. Cephalometric data were collected from 100 children diagnosed with class I malocclusion between the ages 6 to 13 years who visited the pediatric dentist at Seoul National University Dental Hospital. To ensure traceability, a phantom device was created. Correction values were calculated by measuring the length and angle of the phantom device using the software. Type A uncertainty was calculated by obtaining the standard deviation of cephalometric measurements of 100 persons and the standard error of repeated measurements. Determination of the type B uncertainty was induced by minimum resolution and the position of the head. Using these, the combined standard uncertainty was obtained and the expanded uncertainty was calculated. The results of this study confirm that the currently used software has high accuracy and reliability. Furthermore, the uncertainty of orthodontic measurements in Korean children aged 6 to 13 years was calculated, and distribution range for class I malocclusion with 95% confidence interval was suggested.

The Correlations among the Categorized Quality Cost Factors on SMEs (Small & Medium-sized Enterprises) (중소 제조기업의 품질비용 행태에 관한 실증 연구)

  • Lee, Sang-Choon;Koo, Il-Seob
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.04a
    • /
    • pp.731-746
    • /
    • 2011
  • The successful and sustainable growth of SMEs depends on their ability of strengthen their competitiveness in quality and cost and service more than anything else as a fundamental of operation. Among these key competitive factors of SMEs, quality is the most critical factor in manufacturing business fields. Because quality strongly influence cost and service performance on this manufacturing business field. There are many different ways to improve the quality performance but it needs proper management decision to choose the best way what can maximize outputs with minimum inputs. And it needs effective measurement methods and some indicators to analysis the quality performance properly. The quality cost is one of the simplest key indicators to measure the quality performance and the effectiveness of quality related management decisions. The major purpose of this study is to diagnose the categorized current level of actual quality cost of local SMEs to maximize their quality management effectiveness through comparing their level with others what's expressed in early studies. In this study, through survey on local SMEs, we found that their average annual quality cost ratio versus turnover - Total amount of annual quality cost divided by annual turnover - is around 3.69% excluded some SME's performances what have different quality control measures with others. And we found some results what corresponded with the early studies on the correlations between those categorized quality costs factors and some discrepancies between some of the literature model and the early case study results as follows. There were negative correlations between the Prevention costs and the External failure costs, and the Appraisal costs and the External failure costs, and there was positive correlation between the Appraisal costs and Internal failure costs same as early studies. But, we couldn't found any strong negative correlations between the Cost of control - Preventive costs & Appraisal costs - and the Cost of Failure of control - Internal & External failure costs -. It reveals not only the lack of effectiveness on their preventive or appraisal activities but also it can reveal there were so many effective ways to prevent the failure costs properly such as some innovative investment on Factory automation includes Error Proofing and more preventive actions to improve the effectiveness of the typical management methods likes CE (Concurrent Engineering), APQP (Advanced Product Quality Planning), FMEA (Failure Mode & Effect Analysis) etc.

  • PDF

Improvement of Nottingham Grading System for Facial Asymmetry Evaluation (안면비대칭 평가를 위한 Nottingham Grading System의 문제점 개선)

  • Lee, Min-Woo;Jang, Min;Kim, Jina;Shin, Sang-Hoon
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.2
    • /
    • pp.179-186
    • /
    • 2017
  • Because facial asymmetry is caused by various causes, the cause analysis is important and quantitative index is needed to the evaluation. In this study, we applied the Nottingham Grading System that was used as a quantitative index to evaluate the facial paralysis by tracking the markers through the image processing and calculating the distance between the markers with images obtained by using the webcam, to evaluate facial asymmetry. The existing Nottingham Grading System has a problem of causing a measurement error in the specific case because the left and right are compared by summing the distance change between the feature points of the face part according to the change of the facial expression. We compared the case of the facial asymmetry and case of normal subject by using the existing Nottingham Grading System and the improved Nottingham grading system. In the existing Nottingham Grading System, case of facial asymmetry and case of facial symmetry were 99.0% and 95.0% respectively in the normal range, but the improved Nottingham Grading System showed facial asymmetry case was 74.0% and facial symmetrical case was 93.2%. The results of experiment show that the improved Nottingham Grading System allows detailed evaluation of each site and improved the problem of the Nottingham Grading System for specific cases.