• 제목/요약/키워드: Measurement Deviation

검색결과 960건 처리시간 0.027초

하트만 방법에 의한 광학면의 기상측정 (On-Machine Measurement of an Optical Surface by Hartmann Test)

  • 김용관;오창진;이응석;김옥현
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.474-480
    • /
    • 2002
  • Aspheric optical lenses and mirrors are widely used in recent. It is more difficult to manufacture and measure the aspherical optics compared to conventional spherical ones. The interferometric optical test is common for the measurement of spherical optical surface. But the application of the interferometry to the measurement of aspheric surface is difficult because it needs a precise null corrector and very careful environmental conditions such as keeping constant temperature, humidity, atmospheric pressure and vibrations. To enhance productivity of optics manufacturing on-machine measurement and correction has been developed in this study. For practical applications, robustness of the measurement method to environments is more important. For the purpose an optical OMM(On-Machine Measurement) system has been developed using Shack-Hartmann test which has robustness to the environment. The wavefront has been reconstructed from the measured data using the primary aberration polynomial function by least square fitting. The measured result of the developed only system gives the maximum deviation only in 200 nm from the result measured by a commercial Fizeau interferometer Wyko 6000.

  • PDF

유물실측을 통한 여자저고리의 치수연구 (A Study on stylistic measurement of Chogori with Museum specimens)

  • 유송옥
    • 복식
    • /
    • 제32권
    • /
    • pp.21-30
    • /
    • 1997
  • Chogori the basic upper garment of korea costume occupies an important role in tra-ditional dressing and continues to be in use to the present days. Of course there has been changes in the length and line of Chogori with the flow of time based on the Ancient Yoo. This is a study of the 14 parts of Chgori based on statistical analysis by computing the practical measuements. Here the statistical analysis is a objective and quantitative of the stylistic changes in Chogori with time. In this study from the data the Mean and Standard deviation has been evaluated and periodic change is shown by graph to test the periodic change T-test Regressional analysis Index analysis has been used. The results are as follows: 1. The length of clothing has changed with time except the sleeve length. Here the length of clothing means all the other measurements ex-cept the sleeve Thus while the measurements of sleeve length has been uniquely unchanged the other measurements have influenced each other. 2. Generally the form of Chogori had the tendency towards smallness in the 19th cen-tury. But it tended to get larger in the 20th century. 3. Compared to other periods the mode of 19th and 20th century Chogori was widely ac-cepted as the Standard deviation of that period was very narrow. 4. The results seen from the regressional analysis of the Cho-sun period woman's Chogori satisfy the t-value and R-squared and thus support the regression formula presump-tion. 5. From the index analysis it is revealed that with decrease in the armhole measurement sleeve measurement and neckband; relatively same decrease in the wrist measurement; and very marked decrease in the sideline measurement.

  • PDF

휴대용 뇨당 측정 시스템의 개발 (Development of an Portable Urine Glucose Monitoring System)

  • 박호동;이경중;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권5호
    • /
    • pp.397-403
    • /
    • 2002
  • 뇨당 측정 시스템은 소변 속의 글루코오스 농도를 측정함으로서 당뇨 수치를 모니터링하는 비침습적인 당뇨병 자가 진단 장치이다. 본 논문에서는 기존의 침습형 혈당측정방법의 불편성과 비색계를 이용한 뇨당 검사법의 단점을 보완한 뇨당 측정시스템을 설계하였다. 뇨당 측정시스템은 뇨당 측정용 화학센서, 신호검출부, 디지털 제어 및 신호분석부, 디스플레이부 및 전원부로 구성된다. 뇨당측정용 센서로는 재현성이 뛰어나고 다루기가 간편하며 저렴한 가격으로 대량 생산할 수, 있는 일회용 뇨당측정용 전류화학센서를 개발하였다. 설계한 뇨당 측정시스템의 성능을 평가하기 위하여 사람의 소변에 임의의 농도의 글루코오스 성분을 섞은 용액에 대하여 글루코오스 성분 분석시 사용되는 표준장비와의 비교분석을 통해서 글루코오스 농도 검출에 대한 신뢰성 평가를 수행하였다. 회귀분석에 기초한 신뢰성 평가를 수행한 결과 표준오차는 2.85282로 나타났다. 또한, 화학센서를 사용해서 측정하는 시스템을 평가 시 중요한 파라미터인 S.D(Standard Deviation)는 10%로서 임상적으로 유효한 15% 범주 내에 있음을 확인하였고, C.V(Coefficient of Validation)값은 ,5%이내이므로 혈당센서의 기준으로 평가해 볼때 만족하는 결과를 보였다.

A Study of Diffraction Effect on LCOS Microdisplay

  • Liu, Weimin;Liu, Joe;Liu, Vincent;Chiang, Wei Chen;Cheng, Hui Lun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.373-376
    • /
    • 2004
  • The measurement of diffraction of LCOS microdisplay with various pixel size, interpixel gap, pixel height and coatings demonstrates that pixel size is the leading factor for diffraction loss, while the role of varying pixel gap is less significant comparatively. One-dimensional diffraction simulation is found to be in good agreement with the measurement. Noticeable deviation occurs when pixel size is as small as 8um.

  • PDF

단일 톤 신호의 페이저 측정기법 및 FPGA구현 (An FPGA implementation of phasor measurement algorithm for single-tone signal)

  • 안병선;김종윤;장태규
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(4)
    • /
    • pp.171-174
    • /
    • 2002
  • This paper presents an implementation method of phasor measurement device, which is based on the FPGA implementation of the sliding-DFT The design is verified by the timing simulation of its operation. The error effect of coefficient approximation and frequency deviation in the recursive implementation of the sliding-DFT is analytically derived and verified with the computer simulations.

  • PDF

수신신호세기의 편차 보정법을 이용한 무선센서노드 간의 거리 추정 (Ranging the Distance Between Wireless Sensor Nodes Using the Deviation Correction Method of Received Signal Strength)

  • 이진영;김중규
    • 대한임베디드공학회논문지
    • /
    • 제7권2호
    • /
    • pp.71-78
    • /
    • 2012
  • Based on the Zigbee-based wireless sensor network, I suggest the way to reduce errors between the short distance, improving the accuracy of the presumed distance by revising the deviation of RSSI(Received Signal Strength Indication) values is to estimate the distance using only the RF signal power without the additional hardware. In general, the graph measured by RSSI values shows the proximity values which are ideally reduced in proportion to the distance under the free outdoor space in which LOS(Line-Of-Sight) is guaranteed. However, if the result of the received RSSI values are each substituted to the formula, it can produce a larger margin of error and less accurate measurement since it is based upon the premise that this free space is not affected by reflected waves or obstacles caused by the ground and electronic jamming engendered by the environment. Therefore, the purpose of this study is to reduce the margin of errors between the distances and to measure the proximity values with the ideal type of graph by suggesting the way to revise the received RSSI values in the light of these reflected waves or obstacles and the electronic jamming. In conclusion, this study proves that errors are reduced by comparing the proposed deviation correction method to the revised RSSI value.

PCB에 장착된 SMD 의 부분영상을 이용한 리드의 최대 벗어난 양의 측정 (Measurement of maximum deviation of leads using partial image of SMD mounted on PCB)

  • 신동원;유준호
    • 제어로봇시스템학회논문지
    • /
    • 제5권6호
    • /
    • pp.698-704
    • /
    • 1999
  • There are several types of defects of SMDs mounted on PCB, that is, missing components, misalignment, wrong parts and poor solder joints. This research study mainly focuses on measuring of deviation of SMD leads using the partial image of component, not using the full image. This processing based on the partial image has the advantage of the reduction in calculation time compared to the full image. Since position of lead is calculated with respect of the reduction in calculation time compared to the full image. Since position of lead is calculated with respect to pad, the accuracy of the system is not dependent on percise positioning stage. The grabbed image of gray scale is converted into binary format using a cutomatic threshold. After small fragments in the image is removed by a series of morphology operations such as opening and closing, the centroids of PCB pads and SMD leads is obtained together with labeling of blobs. Translational shift and rotationial angle of SMD are succedingly estimated using above information and chip data. The expression that can calculate the maximum deviation of leads with respect to PCB pads has been derived, and inferior mounting of SMD is judged by a given criterion. Some experiments have been executed to verify this measuring scheme.

  • PDF

공정능력지수에 대한 비교와 적용 (Comparison and Application of Process Capability indices)

  • 정영배;김연수
    • 산업경영시스템학회지
    • /
    • 제30권4호
    • /
    • pp.182-189
    • /
    • 2007
  • Process Capability indices(PCIs) have been widely used in manufacturing industries to provide a quantitative measure of process performance. PCIs have been developed to represent process capability more exactly. The traditional process capability indices Cp, Cpk, Cpm, $Cpm^+$ have been used to characterize process performance on the basis of univariate quality characteristics. Cp, Cpk consider the process variation, Cpm considers both the process variation and the process deviation from target and $Cpm^+$ considers economic loss for the process deviation from target In the previous studies, only one designated location on each part is measured. System process capability index even though in single process, multiple measurement locations on each part are required to calculate the reliable process capability. In manufacturing industry, there is growing interest in quantitative measures of process variation under multivariate quality characteristics. The multivariate process capability index incorporates both the process variation and the process deviation from target or considers expected loss caused by the process deviation from target. In this paper, we compare various process capability indices and propose the application method of PCIs.

Comparison between Isokinetic Peak Torque and Isotonic 1RM on the Knee Joint

  • Jaehyun Yoo
    • Physical Therapy Rehabilitation Science
    • /
    • 제12권2호
    • /
    • pp.201-205
    • /
    • 2023
  • Objective: Resistance exercise is a necessary element to improve quality of life, and measurement and evaluation of muscle strength provide important information for prescription and management of rehabilitation and exercise programs. This study analyzed the correlation between direct and indirect 1RM for isokinetic maximum torque of the knee joint in order to provide useful information in the field of exercise programs. In addition, the flexion-extension ratio and the difference in left-right deviation were verified. Design: A cross-sectional study Methods: The subjects of this study were 33 healthy adult men and women without medical problems who participated in the health exercise class program at S University in Seoul. The correlation between isokinetic maximum torque and direct and indirect 1RM was analyzed, and a dependent t-test was performed to analyze the flexion-extension ratio and left-right deviation. Results: There was a high correlation between the isokinetic maximum torque and direct and indirect 1RM, and no statistically significant difference was shown between the test methods in the analysis of the flexion-extension ratio and left-right deviation. Conclusions: Isokinetic muscle function measuring equipment is expensive, so it is difficult to use it in local exercise rehabilitation and training sites. Through this study, it was found that direct and indirect 1RM isokinetic maximum torque showed a high correlation, and there was no difference in evaluating muscle function such as flexion-extension ratio and left-right deviation. Therefore, it is considered that the muscle function evaluation using 1RM in general field can be usefully utilized.

국가교정검사기관의 전자파전력 측정정확도의 분석 및 평가 (Analysis and Evaluation of the Accuracy of Electromagnetic Power Measurement at National Calibration and Test Organizations)

  • 강태원;강웅택;박병권
    • 전자공학회논문지A
    • /
    • 제32A권1호
    • /
    • pp.53-60
    • /
    • 1995
  • The aims of this study are to evaluate the measurement capability of the electromagnetic power and to understand the current state of standard maintanance of the eight participants among the thirteen national calibration and test organizations. The calibration factors were measured at six test frequencies, 50, 100, 500, 1000, 5000, 10000 MHz by organizations and KRISS on the basis of round robin test. The results were analyzed by calculating the standard deviation of the measured values from the standard values. The analysis shows good agreement within 1.0% for all participants at the measurement frequencies. Therefore, the measurement capability of all participants is good in the frequency range of 50 MHz to 10 GHz. For the four participants which specified standard deviations of repeated measurements in their reporst, the total uncertainties is less than 1.9% at the measurement frequencies.

  • PDF