• Title/Summary/Keyword: Measurement Angle

Search Result 2,166, Processing Time 0.033 seconds

Gravity Survey on the Southwestern Area of Jechǒn in the Okchǒn Zone (제천(提川) 서남부(西南部) 옥천대(沃川帶) 지역(地域)에 대(對)한 중력탐사연구(重力探査硏究))

  • Min, Kyung Duck;Park, Hye Sim
    • Economic and Environmental Geology
    • /
    • v.22 no.2
    • /
    • pp.91-102
    • /
    • 1989
  • The gravity measurement has been conducted at 61 stations with an interval of about 500 to 1,000 m along two survey lines of about 47 Km between $Chungju-Jech{\check{o}}n$ and $Salmi-D{\check{o}}cksanmy{\check{o}}n$ in order to study on the subsurface geologic structure and structural relation between $Okch{\check{o}}n$ Group and Great Limestone Group of $Chos{\check{o}}n$ Supergroup. The Bouger gravity anomalies were obtained from the reduction of the field observations, and the distribution patterns of the basement and subsurface geologic structure were interpreted by means of the Fourier-Series and Talwani method for two-dimensional body. The depth of Conrad discontinuity varies from 12.7 Km to 15.7 Km, and vertical displacements along the Osanri and Bonghwajae faults are 1.0 Km and 1.5 Km, respectively between Chungju and $Jech{\check{o}}n$. The depth of Conrad discontinuity varies from 13.8 Km to 15.4 Km, and vertical displacement along the Bonghwajae fault is 0.5 Km between Salmi and $D{\check{o}}cksanmyon$. The basement is widely exposed at several places between Chungju and $Jech{\check{o}}n$. In the unexposed area between Osanri and $W{\check{o}}lgulri$, its depth is from 1.5 Km to 2.1 Km. It is displaced downward along the Osanri and Bonghwajae faults by 0.8 Km and 0.6 Km, respectively, and is displaced upward along the Dangdusan fault by 1.6 Km. On the other hand, the depth of the basement varies abruptly by the Sindangri, Jungwon, Kounri, and Bonghwajae faults between Salmi and $D{\check{o}}cksanmy{\check{o}}n$, and it is from 2.8 Km to 3.2 Km around $Salmimy{\check{o}}n$, from 1.6 Km to 2.5 Km between the Sindangri and Bonghwajae faults, 3.0 Km near Koburangjae, and 2.5 Km at $Doj{\check{o}}nri$. The high Bouguer gravity anomalies are due to the accumulation of $Okch{\check{o}}n$ Group and $Jangs{\check{o}}nri$ Metamorphic Complex whose density is higher than the basement exposed between Sondong and Osanri, and imply the existance of Bonghwajae Metabasite or hornblende gabbro of high density distributed along the Bonghwajae fault in the vicinity of Koburangjae. The low Bouguer gravity anomalies resulted form the fracture zone associated with fault or rock of low density imply the existance of the Osanri, Bonghwajae, Dangdusan faults and $Daed{\check{o}}cksan$ thrust between Chungju and $Jech{\check{o}}n$, the uplift of the basement by the Sindangri, Jungwon, Kounri, and Bonghwajae faults, and extensive distribution of Cretaceous biotite granites between Salmi and $Docksanmy{\check{o}}n$. The thickness of $Okch{\check{o}}n$ metasediments varies from 1.5 Km to 3.2 Km, and that of Great Limestone Group of $Chos{\check{o}}n$ Supergroup from 200 m to 700 m. It is interpreted that $Okch{\check{o}}n$ Group is in contact with Great Limestone Group of $Chos{\check{o}}n$ Supergroup by the fault zones of the Bonghwajae and $Daed{\check{o}}cksan$ faults, and the Bongwhajae fault is a thrust of high angle, by which the east of the basement is displaced downward 0.5 Km between Chungju and lechon, and 1.0 Km between Salmi and $D{\check{o}}cksanmy{\check{o}}n$.

  • PDF

Structural Characteristics and Physical Properties of Wild Silk Fibres; Antheraea pernyi and Antheraea yamamai (야잠사의 구조특성 및 물리적 성질)

  • 권해용;박영환
    • Journal of Sericultural and Entomological Science
    • /
    • v.36 no.2
    • /
    • pp.138-146
    • /
    • 1994
  • The structural characteristics of Antheraea yamamai and Antheraea pernyi silk were investigated by using x-ray diffraction method, IR spectroscopy and polarizing microscopy. The amino acid composition, fiber density, thermal decomposition temperature and glass transition temperature were also measured for relating these physical properties to the structure in comparison with those of Bombyx mori silk fiber. There was no significant structural difference between A. yamamai and A. pernyi silk fiber on an examination of x-ray diffraction curve and IR spectrum. Both of these wild silk fibers showed double diffraction peaks at the Bragg angle 2Θ16.7˚ and 20.5˚by x-ray diffraction analysis as well as IR absorption peaks for the bending vibration of specific groups related to ala-ala amino acid sequence. On the other hand, the x-ray diffraction curve and IR spectrum of Bombyx mori silk fiber are different from those of wild silk fibers, indicating different crystal structure as well as amino acid sequences. It showed under the polarizing microscope examination that the birefringence and optical orientation factor of wild silk fibers are much lower than those of B. mori silk. Also, the surface of degummed wild silk fibers was characterized by the longitudinal stripes of microfibrils in the direction of fiber axies. The amino acid composition, which is strongly related to the fine structure and properties, was not significantly different between these two wild silk fibers. However, the alanine content was somewhat less and polar amino acid content more for A. yamamai. As a result of fiber density measurement, the specific gravities of B. mori, A. pernyi and A. yamamai were 1.355~1.356, 1.308~1.311, 1.265~1.301g/㎤ in the order, respectively. The calculated crystallinity(%) was 64% for B. mori and 51~52% for wild silk fibers, which showed same trend by IR method in spite of somewhat higher value. The thermal decomposition behaviour was examined by DSC and TGA, showing that the degradation temperature was in the order of B mori, A. prernyi and A. yamamai at around 350$^{\circ}C$. It was also observed by TGA that the decomposition seems to proceed step by step according to their specific regions in the fiber structure, resulting the difference in their thermal stabilities. The glass transition temperature was turned out to be 220$^{\circ}C$ for B. mori, 240$^{\circ}C$ A. yamamai and 255$^{\circ}C$ A. pernyi by the dynamic mechanical analysis. It is expected that the chemical properties are affected by the dynamic mechanical behavior in accordance with their structural characters.

  • PDF

Monitoring soybean growth using L, C, and X-bands automatic radar scatterometer measurement system (L, C, X-밴드 레이더 산란계 자동측정시스템을 이용한 콩 생육 모니터링)

  • Kim, Yi-Hyun;Hong, Suk-Young;Lee, Hoon-Yol;Lee, Jae-Eun
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.2
    • /
    • pp.191-201
    • /
    • 2011
  • Soybean has widely grown for its edible bean which has numerous uses. Microwave remote sensing has a great potential over the conventional remote sensing with the visible and infrared spectra due to its all-weather day-and-night imaging capabilities. In this investigation, a ground-based polarimetric scatterometer operating at multiple frequencies was used to continuously monitor the crop conditions of a soybean field. Polarimetric backscatter data at L, C, and X-bands were acquired every 10 minutes on the microwave observations at various soybean stages. The polarimetric scatterometer consists of a vector network analyzer, a microwave switch, radio frequency cables, power unit and a personal computer. The polarimetric scatterometer components were installed inside an air-conditioned shelter to maintain constant temperature and humidity during the data acquisition period. The backscattering coefficients were calculated from the measured data at incidence angle $40^{\circ}$ and full polarization (HH, VV, HV, VH) by applying the radar equation. The soybean growth data such as leaf area index (LAI), plant height, fresh and dry weight, vegetation water content and pod weight were measured periodically throughout the growth season. We measured the temporal variations of backscattering coefficients of the soybean crop at L, C, and X-bands during a soybean growth period. In the three bands, VV-polarized backscattering coefficients were higher than HH-polarized backscattering coefficients until mid-June, and thereafter HH-polarized backscattering coefficients were higher than VV-, HV-polarized back scattering coefficients. However, the cross-over stage (HH > VV) was different for each frequency: DOY 200 for L-band and DOY 210 for both C and X-bands. The temporal trend of the backscattering coefficients for all bands agreed with the soybean growth data such as LAI, dry weight and plant height; i.e., increased until about DOY 271 and decreased afterward. We plotted the relationship between the backscattering coefficients with three bands and soybean growth parameters. The growth parameters were highly correlated with HH-polarization at L-band (over r=0.92).

A Study on Automated Lineament Extraction with Respect to Spatial Resolution of Digital Elevation Model (수치표고모형 공간해상도에 따른 선구조 자동 추출 연구)

  • Park, Seo-Woo;Kim, Geon-Il;Shin, Jin-Ho;Hong, Sang-Hoon
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.439-450
    • /
    • 2018
  • The lineament is a linear or curved terrain element to discriminate adjacent geological structures in each other. It has been widely used for analysis of geology, mineral exploration, natural disasters, and earthquake, etc. In the past, the lineament has been extracted using cartographic map or field survey. However, it is possible to extract more efficiently the lineament for a very wide area thanks to development of remote sensing technique. Remotely sensed observation by aircraft, satellite, or digital elevation model (DEM) has been used for visual recognition for manual lineament extraction. Automatic approaches using computer science have been proposed to extract lineament more objectively. In this study, we evaluate the characteristics of lineament which is automatically extracted with respect to difference of spatial resolution of DEM. We utilized two types of DEM: one is Shuttle Radar Topography Mission (SRTM) with spatial resolution of about 90 m (3 arc sec), and the other is the latest world DEM of TerraSAR-X add-on for Global DEM with 12 m spatial resolution. In addition, a global DEM was resampled to produce a DEM with a spatial resolution of 30 m (1 arc sec). The shaded relief map was constructed considering various sun elevation and solar azimuth angle. In order to extract lineament automatically, we used the LINE module in PCI Geomatica software. We found that predominant direction of the extracted lineament is about $N15-25^{\circ}E$ (NNE), regardless of spatial resolution of DEM. However, more fine and detailed lineament were extracted using higher spatial resolution of DEM. The result shows that the lineament density is proportional to the spatial resolution of DEM. Thus, the DEM with appropriate spatial resolution should be selected according to the purpose of the study.

Skin Damage Sustained During Head-and-Neck and Shoulder Radiotherapy Due to the Curvature of Skin and the Use of Immobilization Mask (머리-목 그리고 어깨의 방사선 치료 시 피부곡면과 고정장치로 인한 피부손상연구)

  • Kim, Soo-Kil;Jeung, Tae-Sig;Lim, Sang-Wook;Park, Yeong-Mouk;Park, Dahl
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.86-92
    • /
    • 2010
  • The purpose of this study was to measure curvature contour skin dose using radiochromic film and TLD for a conventional open field. We also attempted to quantify the degradation of skin sparing associated with use of immobilization devices for high energy photon beams and to calculate the skin dose with a help of Monte Carlo (MC) simulation. To simulate head-and-neck and shoulder treatment, a cylindrical solid water phantom 11 cm in diameter was irradiated with 6 MV x-rays using $40{\times}40\;cm^2$ field at 100 cm source axis distance (SAD) to the center of the phantom. Aquaplastic mesh mask was placed on the surface of the cylindrical phantom that mimicked relevant clinical situations. The skin dose profile was obtained by taking measurements from $0^{\circ}$ to $360^{\circ}$ around the circumference of the cylindrical phantom. The skin doses obtained from radiochromic film were found to be 47% of the maximum dose of $D_{max}$ at the $0^{\circ}$ beam entry position and 61% at the $90^{\circ}$ oblique beam position without the mask. Using the mask (1.5 mm), the skin dose received was 59% at $0^{\circ}$ incidence and 78% at $80^{\circ}$ incidence. Skin dose results were also gathered using thin thermoluminescent dosimeters (TLD). With the mask, the skin dose was 66% at $0^{\circ}$ incidence and 80% at $80^{\circ}$ incidence. This method with the mask revealed the similar pattern as film measurement. For the treatments of the head-and-neck and shoulder regions in which immobilization mask was used, skin doses at around tangential angle were nearly the same as the prescription dose. When a sloping skin contour is encountered, skin doses may be abated using thinner and more perforated immoblization devices which should still maintain immoblization.

Feasibility of MatriXX for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료의 품질관리를 위한 이온전리함 매트릭스의 유용성 고찰)

  • Kang, Min-Young;Kim, Yoen-Lae;Park, Byung-Moon;Bae, Yong-Ki;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.91-97
    • /
    • 2007
  • Purpose: To evaluate the feasibility of a commercial ion chamber array for intensity modulated radiation therapy (IMRT) quality assurance (QA) was performed IMRT patient-specific QA Materials and Methods: A use of IMRT patient-specific QA was examined for nasopharyngeal patient by using 6MV photon beams. The MatriXX (Wellhofer Dosimetrie, Germany) was used for IMRT QA. The case of nasopharyngeal cancer was performed inverse treatment planning. A hybrid dose distribution made on the CT data of MatriXX and solid phantom all of the same gantry angle (0$^\circ$). The measurement was acquired with geometrical condition that equal to hybrid treatment planning. The $\gamma$-index (dose difference 3%, DTA 3 mm) histogram was used for quantitative analysis of dose discrepancies. An absolute dose was compared at the high dose low gradient region. Results: The dose distribution was shown a good agreement by gamma evaluation. A proportion of acceptance criteria was 95.8%, 97.52%, 96.28%, 98.20%, 97.78%, 96.64% and 92.70% for gantry angles were 0$^\circ$, 55$^\circ$, 110$^\circ$, 140$^\circ$, 220$^\circ$, 250$^\circ$ and 305$^\circ$, respectively. The absolute dose in high dose low gradient region was shown reasonable agreement with the RTP calculation within $\pm$3%. Conclusion: The MatriXX offers the dosimetric characteristics required for performing both relative and absolute measurements. If MatriXX use in the clinic, it could be simplified and reduced the IMRT patient-specific QA workload. Therefore, the MatriXX is evaluated as a reliable and convenient dosimeter for IMRT patient-specific QA.

  • PDF

A comparison between the modified Brostrom procedure using single and double suture anchor for chronic lateral ankle instability (발목관절 외측 불안정성에서 단일 봉합나사와 이중 봉합나사를 이용한 변형 Brostrom 술식간의 임상결과 비교)

  • Shon, Hyun-Chul;Cho, Byung-Ki;Kim, Yong-Min;Kim, Dong-Soo;Choi, Eui-Sung;Park, Kyoung-Jin;Park, Ji-Kang
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.2
    • /
    • pp.69-77
    • /
    • 2011
  • Purpose: This study was retrospectively performed to compare the clinical outcomes of modified Brostrom procedures using the single suture anchor and the double suture anchor for chronic lateral ankle instability. Materials and Methods: Thirty-seven patients were followed up for more than 1 year after the modified Brostrom procedures using suture anchor. Single surgeon treated seventeen cases with single suture anchor and 20 cases with double suture anchor. The clinical evaluation was performed according to the Karlsson scale and Sefton grading system. Radiologic measurement of the talar tilt and anterior talar translation was performed through anterior and varus stress radiographs using Telos device. Results: The Karlsson scale had improved significantly from preoperative average of 45.2 points to 89.4 points in single suture anchor group, and from 46.4 points to 90.5 points in double suture anchor group. According to the Sefton grading system, 15 cases (88.2%) in single suture anchor group and 18 cases (90%) in double suture anchor group achieved satisfactory results. The talar tilt angle and anterior talar translation had improved significantly from preoperative average of $13.6^{\circ}$ and 8.6 mm to $5.4^{\circ}$ and 4.1 mm in single suture anchor group, from $14.1^{\circ}$ and 8.4mm to $3.9^{\circ}$ and 4 mm in double suture anchor group. Double suture anchor technique was significantly superior in postoperative talar tilt. Conclusion: Single and double suture anchor techniques produced similar clinical and functional outcomes except for talar tilt, which was significantly superior in double suture anchor group. Both modified Brostrom procedures using the single and double suture anchor appear to be effective treatment methods for chronic lateral ankle instability. Further evaluation of clinical outcomes and biomechanical studies in athletes are needed.

  • PDF

Assessment of the Breast-Firmming Effects of a Cosmetic Preparation with Moir$\acute{e}$ Tophography in Combination with 2D and 3D Digital Image Analyses (2D 및 3D 디지털 이미지 분석과 함께 Moir$\acute{e}$ Tophography 분석을 이용한 화장품의 가슴 탄력개선 효과 평가)

  • Seo, Young Kyoung;Yoo, Mi Ae;Ryu, Ja Hyun;Kim, So Jeong;Cho, Seong A;Nam, Gae Won;Cho, Jun-Cheol;Boo, Yong Chool;Koh, Jae-Sook
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.38 no.4
    • /
    • pp.289-296
    • /
    • 2012
  • Cosmetic products which might augment the breast have attracted an attention and objective methods for the evaluation of such products are in high demand. This study was conducted to establish a method for assessing the breast-firmming effects of cosmetics. This study included a total of 30 healthy Korean females aged 20-50 years. A cosmetic product was applied by massaging it onto the breast twice a day for 8 weeks. Measurement of breast girth with a tape ruler, 2D and 3D digital image analyses, and Moir$\acute{e}$ topographic analysis were performed before and following the treatment. The application of a cosmetic onto the breast significantly increased breast girth at 2, 4 and 8 weeks without a significant change in underbreast girth, implicating the breast might be augmented. The 2D image analysis indicated that the arc length of the breast which represents the surface distance from the nipple to the periphery of the under-breast was significantly increased at 2, 4 and 8 weeks. The height of the breast which represents the perpendicular distance from the nipple to the periphery of the under-breast was also increased significantly at 4 and 8 weeks. The 3D image analysis of body surface also demonstrated a significant increase of breast volume at 2, 4 and 8 weeks. Moir$\acute{e}$ topographic analysis indicated that breast sagging was significantly reduced at 2, 4 and 8 weeks. The results of this study suggest that Moir$\acute{e}$ topography in combination with 2D and 3D digital image analyses may be useful for evaluating the breast-augmenting effects of cosmetics.

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

A Study on the Variation of Transmission Factors, Output Factors and Percent Depth Doses by Wedge Filters for 4~10 MV X-Ray Beams (4~10 MV X-선의 쐐기 (wedge) 필터의 투과율과 출력계수, 선축상 선량분포의 변화에 관한 연구)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.3-17
    • /
    • 1997
  • Because a wedged beam consists of attenuated primary photons and scattered radiations from wedge, the spectrum of the wedged beam does not coincide with that of an open beam with same geometry. The aims of current report are to get exact information about whether effects of 15-60$^{\circ}$ wedge for 4 -10 MV photon beams should be considered for dose calculation or not, and to suggest a reference condition for measurement of wedge transmission factor. Percent depth dose of both open and wedged fields with angles of 15, 30, 45, 60$^{\circ}$ for beams of 4 MV(Clinac 4/100, Varian), two 6 MV(Clinac 6/100 and Clinac 2100C, Varian), 10 MV(Clinac 2100C, Varian) X-rays were measured to 30cm deep in water using ionization chambers. Hardening factors of photon beams were calculated with measured PDDs. Both field size factors and transmission factors of wedge filters were measured at d$_{max}$ in water. Beam hardening factors of wedged fields of 4 and 6 MV X-ray were larger than 1 for all wedge angles, field sizes and depths deeper than d$_{max}$ Beam hardening factors for wedge angles 15, 30, 45, 60$^{\circ}$ for 10$\times$10cm were respectively 1.010, 1.014, 1.023 and 1.034 for 4MV X-ray, 1.005, 1.008, 1.019, and 1.024 for 6MV X-ray of Clinac 6/100, 1.011, 1.021, 1.032, 1.036 for 6MV X-ray of Clinac 2100C, and 1.008, 1.012, 1.012 and 1.012 for 10MV X-ray. Beam hardening factors of 10MV X-ray were 1 within 1.2% difference for all wedge angles, depths and field sizes. It was made clear that for 6MV X-rays, the beam hardening factor depends on treatment machine. The relationship of the factor and depth was linear. Field size factor at d$_{max}$ was independent of wedge angle except for the field of 15$\times$15cm. and maximum difference of the field size factors for the field size was 1.4% for 4MV X-ray. When the wedge factor is determined, dependence of the factor on field size is negligible at d$_{max}$ but should be considered at deeper depth. Calculating dose distribution or MU, the beam hardening factor should be applied for 4~6MV X-ray beams, but might not be considered for 10MV beam. When wedge transmission factor was determined at d$_{max}$ or in air, field size factors for open field are also applicable to wedged fields, but otherwise, field size factor for each wedge or wedge factor depending on field size should be applied.

  • PDF