• Title/Summary/Keyword: Measurement Algorithm

Search Result 2,919, Processing Time 0.03 seconds

Numerical Analysis of Differential Absorption Lidar for Measuring Atmospheric Pollutants (대기오염 측정용 DIAL시스템의 오차해석)

  • 박진화;이용우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.428-433
    • /
    • 2003
  • In this study, we composed algorithm of DIAL(Differential Absorption Lidar). we investigated the absorption spectrum of $O_3$, S $O_2$ and N $O_2$ dependent on wavelengths using data base UV-Bank and determine the optimized wavelength model. Here, the selected optimal wavelengths are 292.00(λ$_{on}$ ), 295.20(λ$_{off}$) for $O_3$, 299.38(λ$_{on}$ ), 300.05(λ$_{off}$) for S $O_2$ and 448.00(λ$_{on}$ ), 449.85(λ$_{off}$) for N $O_2$. In particular, we established the supposed model of DIAL and simulated the error of measuring distance using the selected optimal wavelength. In the model-I with telescope of 300 mm diameter, laser energy of 3 mJ and transmission of 10000 shots, maximum distances are 4 km for $O_3$ measurement and 5 km for S $O_2$ and N $O_2$ measurements. Also, in the model-II with telescope of 600 mm diameter, laser energy of 30 mJ and transmission of 10000 shots, maximum distances are 13 km for S $O_2$ and N $O_2$ measurements.ments.

  • PDF

The Study of Optical Biopsy‘s Usefulness in Radiotherapy (방사선 치료에서 광학적 생검의 유용성에 관한 연구)

  • ;;Muller M.G.,;Feld M.S.
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.9-17
    • /
    • 2001
  • The prior purpose of this study is to introduce a optical biopsy and evaluate whether the optical biopsy, real-time, non-invasive technique, is a reliable tool to assess response to radiotherapy Four healthy volunteers, and four patients with inflammatory conditions of the oral cavity participated on the study. was obtained from each person enrolled in the study. Using FastEEM(Ercited Emission Matrix) as a optical biopsy tool, normal and tumor spectra are taken from the normal and the tumor regions. And then second optical biopsy are taken from the tumor regions in 4 patients with time delay at 7days.. Using a diagnostic algorithm, made by Gillenwater based on spectra excited at 337nm The Optical Biopsy turned out to be more suited for tumor diagnostic resulting in significant difference fluorescence spectra. The fluorescence intensity of cancerous tissue showed a higher position. The second fluorescence intensity of optical biopsy of cancerous oral tissue has more smaller than the first result. I conclude that optical biopsy, which technique don't need to remove tissue sample from body, and is a real time , and non-invasive measurement is a reliable tool to access to radiotherapy because FastEEM can do measure the variation of the tissue composition chemical, biological, and morphological after radiotherapy. Based on the fluorescence spectrum are taken from the optical biopsy in normal and tumor spectra as well as tumor spectra after 7days.

  • PDF

Development of Radar Polygon Method : Areal Rainfall Estimation Technique Based on the Probability of Similar Rainfall Occurrence (Radar Polygon 기법의 개발 : 유사강우발생 확률에 근거한 면적강우량 산정기법)

  • Cho, Woonki;Lee, Dongryul;Lee, Jaehyeon;Kim, Dongkyun
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.11
    • /
    • pp.937-944
    • /
    • 2015
  • This study proposed a novel technique, namely the Radar Polygon Method (RPM), for areal rainfall estimation based on radar precipitation data. The RPM algorithm has the following steps: 1. Determine a map of the similar rainfall occurrence of which each grid cell contains the binary information on whether the grid cell rainfall is similar to that of the observation gage; 2. Determine the similar rainfall probability map for each gage of which each grid cell contains the probability of having the rainfall similar to that of the observation gage; 3. Determine the governing territory of each gage by comparing the probability maps of the gages. RPM method was applied to the Anseong stream basin. Radar Polygons and Thiessen Polygons of the study area were similar to each other with the difference between the two being greater for the rain gage highly influenced by the orography. However, the weight factor between the two were similar with each other. The significance of this study is to pioneer a new application field of radar rainfall data that has been limited due to short observation period and low accuracy.

An Experiment for Surface Reflectance Image Generation of KOMPSAT 3A Image Data by Open Source Implementation (오픈소스 기반 다목적실용위성 3A호 영상자료의 지표면 반사도 영상 제작 실험)

  • Lee, Kiwon;Kim, Kwangseob
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_4
    • /
    • pp.1327-1339
    • /
    • 2019
  • Surface reflectance obtained by absolute atmospheric correction from satellite images is useful for scientific land applications and analysis ready data (ARD). For Landsat and Sentinel-2 images, many types of radiometric processing methods have been developed, and these images are supported by most commercial and open-source software. However, in the case of KOMPSAT 3/3A images, there are currently no tools or open source resources for obtaining the reflectance at the top-of-atmosphere (TOA) and top-of-canopy (TOC). In this study, the atmospheric correction module of KOMPSAT 3/3A images is newly implemented to the optical calibration algorithm supported in the Orfeo ToolBox (OTB), a remote sensing open-source tool. This module contains the sensor model and spectral response data of KOMPSAT 3A. Aerosol measurement properties, such as AERONET data, can be used to generate TOC reflectance image. Using this module, an experiment was conducted, and the reflection products for TOA and TOC with and without AERONET data were obtained. This approach can be used for building the ARD database for surface reflection by absolute atmospheric correction derived from KOMPSAT 3/3A satellite images.

A Study on the Automatic Detection of Railroad Power Lines Using LiDAR Data and RANSAC Algorithm (LiDAR 데이터와 RANSAC 알고리즘을 이용한 철도 전력선 자동탐지에 관한 연구)

  • Jeon, Wang Gyu;Choi, Byoung Gil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.4
    • /
    • pp.331-339
    • /
    • 2013
  • LiDAR has been one of the widely used and important technologies for 3D modeling of ground surface and objects because of its ability to provide dense and accurate range measurement. The objective of this research is to develop a method for automatic detection and modeling of railroad power lines using high density LiDAR data and RANSAC algorithms. For detecting railroad power lines, multi-echoes properties of laser data and shape knowledge of railroad power lines were employed. Cuboid analysis for detecting seed line segments, tracking lines, connecting and labeling are the main processes. For modeling railroad power lines, iterative RANSAC and least square adjustment were carried out to estimate the lines parameters. The validation of the result is very challenging due to the difficulties in determining the actual references on the ground surface. Standard deviations of 8cm and 5cm for x-y and z coordinates, respectively are satisfactory outcomes. In case of completeness, the result of visual inspection shows that all the lines are detected and modeled well as compare with the original point clouds. The overall processes are fully automated and the methods manage any state of railroad wires efficiently.

Algorithms for Indexing and Integrating MPEG-7 Visual Descriptors (MPEG-7 시각 정보 기술자의 인덱싱 및 결합 알고리즘)

  • Song, Chi-Ill;Nang, Jong-Ho
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.1
    • /
    • pp.1-10
    • /
    • 2007
  • This paper proposes a new indexing mechanism for MPEG-7 visual descriptors, especially Dominant Color and Contour Shape descriptors, that guarantees an efficient similarity search for the multimedia database whose visual meta-data are represented with MPEG-7. Since the similarity metric used in the Dominant Color descriptor is based on Gaussian mixture model, the descriptor itself could be transform into a color histogram in which the distribution of the color values follows the Gauss distribution. Then, the transformed Dominant Color descriptor (i.e., the color histogram) is indexed in the proposed indexing mechanism. For the indexing of Contour Shape descriptor, we have used a two-pass algorithm. That is, in the first pass, since the similarity of two shapes could be roughly measured with the global parameters such as eccentricity and circularity used in Contour shape descriptor, the dissimilar image objects could be excluded with these global parameters first. Then, the similarities between the query and remaining image objects are measured with the peak parameters of Contour Shape descriptor. This two-pass approach helps to reduce the computational resources to measure the similarity of image objects using Contour Shape descriptor. This paper also proposes two integration schemes of visual descriptors for an efficient retrieval of multimedia database. The one is to use the weight of descriptor as a yardstick to determine the number of selected similar image objects with respect to that descriptor, and the other is to use the weight as the degree of importance of the descriptor in the global similarity measurement. Experimental results show that the proposed indexing and integration schemes produce a remarkable speed-up comparing to the exact similarity search, although there are some losses in the accuracy because of the approximated computation in indexing. The proposed schemes could be used to build a multimedia database represented in MPEG-7 that guarantees an efficient retrieval.

Design of Head Blood Pressure(HBP) Measurement System and Correlativity Extraction of Blood Pressure(BP) and HBP (두부혈압 측정 시스템의 설계 및 두부혈압과 상완혈압과의 상관성 추출)

  • 이용흠;정석준;장근중;정동영
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.381-389
    • /
    • 2003
  • Various adult diseases (cerebral apoplexy, athymiait, etc.) result from hypertension, blood circulation disturbance and increment of HBP. In early diagnosis of these diseases, MRI, X-ray and PET have been used rather aim for treatment than for a prevention of disease. Since. cerebral apoplexy and athymiait could appear to the regular/irregular persons, it is very important to measure HBP which has connection with cerebral blood flow state. HBP has more diagnosis elements than that of BP. So, we can diagnose accurate hypertension by measuring of HBP. But, existing sphygmomanometers and automatic BP monitors can not measure HBP, and can not execute complex function(measuring of BP/HBP, blood flow improvement). Purpose of this paper is to develop a system and algorithm which can measure BP/HBP for accurate diagnosis. Also, we extracted diagnosis factors by correlativity analysis of BP/HBP. Maximum pressure of HBP corresponds to 62% that of BP, Minimum pressure of HBP corresponds to 46% that of BP. Therefore, we developed the multi-function automatic blood pressure monitor which can measure BP/HBP and improve cerebral blood flow state.

The Principles and Practice of Induced Polarization Method (유도분극 탐사의 원리 및 활용)

  • Kim, Bitnarae;Nam, Myung Jin;Jang, Hannuree;Jang, Hangilro;Son, Jeong-Sul;Kim, Hee Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.20 no.2
    • /
    • pp.100-113
    • /
    • 2017
  • Induced polarization (IP) method is based on the measurement of a polarization effect known as overvoltage of the ground. IP techniques have been usually used to find mineral deposits, however, nowadays widely applied to hydrogeological investigations, surveys of groundwater pollution and foundation studies on construction sites. IP surveys can be classified by its source type, i.e., time-domain IP estimating chargeability, frequency-domain IP measuring frequency effect (FE), and complex resistivity (CR) and spectral IP (SIP) measuring complex resistivity. Recently, electromagnetic-based IP has been studied to avoid the requirement for spike electrodes to be placed in the ground. In order to understand IP methods in this study, we: 1) classify IP surveys by source type and measured data and illustrate their basic theories, 2) describe historical development of each IP forward modeling and inversion algorithm, and finally 3) introduce various case studies of IP measurements.

A Preliminary Development of Real-Time Hardware-in-the-Loop Simulation Testbed for the Satellite Formation Flying Navigation and Orbit Control (편대비행위성의 항법 및 궤도제어를 위한 실시간 Hardware-In-the-Loop 시뮬레이션 테스트베드 초기 설계)

  • Park, Jae-Ik;Park, Han-Earl;Shim, Sun-Hwa;Park, Sang-Young;Choi, Kyu-Hong
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.1
    • /
    • pp.99-110
    • /
    • 2009
  • The main purpose of the current research is to developments a real-time Hardware In-the-Loop (HIL) simulation testbed for the satellite formation flying navigation and orbit control. The HIL simulation testbed is integrated for demonstrations and evaluations of navigation and orbit control algorithms. The HIL simulation testbed is composed of Environment computer, GPS simulator, Flight computer and Visualization computer system. GPS measurements are generated by a SPIRENT GSS6560 multi-channel RF simulator to produce pseudorange, carrier phase measurements. The measurement date are transferred to Satrec Intiative space borne GPS receiver and exchanged by the flight computer system and subsequently processed in a navigation filter to generate relative or absolute state estimates. These results are fed into control algorithm to generate orbit controls required to maintain the formation. These maneuvers are informed to environment computer system to build a close simulation loop. In this paper, the overall design of the HIL simulation testbed for the satellite formation flying navigation and control is presented. Each component of the testbed is then described. Finally, a LEO formation navigation and control simulation is demonstrated by using virtual scenario.

Image Reconstruction Using Iterative Regularization Scheme Based on Residual Error in Electrical Impedance Tomography (전기 임피던스 단층촬영법에서 잔류오차 기반의 반복적 조정기법을 이용한 영상 복원)

  • Kang, Suk-In;Kim, Kyung-Youn
    • Journal of IKEEE
    • /
    • v.18 no.2
    • /
    • pp.272-281
    • /
    • 2014
  • In electrical impedance tomography (EIT), modified Newton Raphson (mNR) method is widely used inverse algorithm for static image reconstruction due to its convergence speed and estimation accuracy. The unknown conductivity distribution is estimated iteratively by minimizing a cost functional such that the residual error namely the difference in measured and calculated voltages is reduced. Although, mNR method has good estimation performance, EIT inverse problem still suffers from ill-conditioned and ill-posedness nature. To mitigate the ill-posedness, generally, regularization methods are adopted. The inverse solution is highly dependent on the choice of regularization parameter. In most cases, the regularization parameter has a constant value and is chosen based on experience or trail and error approach. In situations, when the internal distribution changes or with high measurement noise, the solution does not get converged with the use of constant regularization parameter. Therefore, in this paper, in order to improve the image reconstruction performance, we propose a new scheme to determine the regularization parameter. The regularization parameter is computed based on residual error and updated every iteration. The proposed scheme is tested with numerical simulations and laboratory phantom experiments. The results show an improved reconstruction performance when using the proposed regularization scheme as compared to constant regularization scheme.