• Title/Summary/Keyword: Measured discharge

Search Result 1,597, Processing Time 0.039 seconds

Empirical recommendation for planning the observation density of water level in a reservoir (Case study on Hwacheon Dam in Korea) (저수지 수위 관측밀도 제안: 화천댐 중심으로)

  • Hwang-Bo, Jong Gu;Hong, Jun Hyuk
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.10
    • /
    • pp.835-841
    • /
    • 2022
  • The water level of the dam reservoir is an important data in the operation of the dam. reservoir storage can be calculated by using water levels or prepared for disasters such as drought and floods. However, the water level is measured near the dam, making it difficult to represent a reservoir with a large area, and there is a high possibility that the water surface will be distorted due to discharge. Furthermore, the results of the survey showed that the water level of the reservoir is irregular rather than constant, and the water level of the reservoir is repeatedly falling and rising by section. In order to calculate such a complex and irregular representative water level, the water level observation density of the reservoir must be increased. In this study, we tried to derive the optimum water level observation density for Hwacheon Dam. A reasonable water level measurement density was derived by investigating the water level elevation of the reservoir and statistically analyzing it. The observation density may vary depending on the size of the reservoir, so the same analysis was conducted on the Goesan Dam and Boseonggang Dam. According to the results, four Hwacheon dams, three Goesan dams, and seven Boseong River dams are needed for observation density.

Profile and Outcome of Management of Brain Tumours in Kaduna Northwestern Nigeria

  • Danjuma, Sale;Dauda, Happy Amos;Kene, Aghadi Ifeanyi;Akau, Kache Stephen;Jinjiri, Ismail Nasiru
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.5
    • /
    • pp.751-757
    • /
    • 2022
  • Objective : Tumours of the brain are a rare occurrence accounting for approximately 2% of all neoplasms in adults. Few studies have been done in Nigeria on the profile of brain tumours. The aim of this study is to determine the profile of brain tumours in general and determine the change in Kanofsky Performance Score (KPS) after treatment. Methods : This is a prospective hospital-based study in Kaduna. All consecutive patients over 18 years of age with diagnosis of brain tumours from January 2016 to December 2019 were included in the study. Demographic and clinical data was collected using a proforma during the study. Patients who received treatment were followed up for 12 months. The primary outcome data was the difference in the quality of life as measured by KPS at the point of first contact and at 1-month after treatment and at 12-month follow up. Data obtained was analysed with SPSS version 25.0 for Windows. Descriptive statistics was done to determine the profile. Paired t-test at 95% confidence interval was done to check for significant correlation between the mean KPS. Results : A total of 39 consecutive patients were included in the study. There was a slight male preponderance with a M : F of 1.17 : 1. Meningioma and metastasis were more common in females while gliomas and pituitary tumours were more common in males. The mean age of patients was 49.8 years and standard deviation of 11.8 years. Pituitary tumours were the most common tumours. The most common location of the tumour was frontal lobe followed by the pituitary gland. The mean duration of symptoms before neurosurgical consultation was 38 weeks. The most common presenting symptoms of patient with brain tumour was headache. The quality of life improve compare to the baseline in 81% of patient at discharge and at 1 year follow up. The overall mortality rate was 25.6%. Conclusion : The most common brain tumour in our study is pituitary tumour. Most patients present late. The most common presenting symptoms is headache. There is significant improvement in the KPS of patients following treatment. The overall mortality rate at 1-year post treatment is 25.6%.

Improvement of lower hybrid current drive systems for high-power and long-pulse operation on EAST

  • M. Wang;L. Liu;L.M. Zhao;M.H. Li ;W.D. Ma;H.C. Hu ;Z.G. Wu;J.Q. Feng ;Y. Yang ;L. Zhu ;M. Chen ;T.A. Zhou;H. Jia;J. Zhang ;L. Cao ;L. Zhang ;R.R. Liang;B.J. Ding ;X.J. Zhang ;J.F. Shan;F.K. Liu ;A. Ekedahl ;M. Goniche ;J. Hillairet;L. Delpech
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4102-4110
    • /
    • 2022
  • Aiming at high-power and long-pulse operation up to 1000 s, some improvements have been made for both 2.45 GHz and 4.6 GHz lower hybrid (LH) systems during the recent 5 years. At first, the guard limiters of the LH antennas with graphite tiles were upgraded to tungsten, the most promising material for plasma facing components in nuclear fusion devices. These new guard limiters can operate at a peak power density of 12.9 MW/m2. Strong hot spots were usually observed on the old graphite limiters when 4.6 GHz system operated with power >2.0 MW [B. N. Wan et al., Nucl. Fusion 57 (2017) 102019], leading to a reduction of the maximum power capability. With the new limiters, 4.6 GHz LH system, the main current drive (CD) and electron heating tool for EAST, can be operated with power >2.5 MW routinely. Long-pulse operation up to 100 s with 4.6 GHz LH power of 2.4 MW was achieved in 2021 and the maximal temperature on the guard limiters measured by an infrared (IR) camera was about 540 ℃, much below the permissible value of tungsten material (~1200 ℃). A discharge with a duration of 1056 s was achieved and the 4.6 GHz LH energy injected into the plasma was up to 1.05 GJ. Secondly, the fully-active-multijunction (FAM) launcher of 2.45 GHz system was upgraded to a passive-active-multijunction (PAM), for which the density of optimum coupling was relatively low (below the cut-off value). Good coupling with reflection coefficient ~3% has been achieved with plasma-antenna distance up to 11 cm for the new PAM. Finally, in order to eliminate the effect of ion cyclotron range of frequencies (ICRF) wave on 4.6 GHz LH wave coupling, the location of the ICRF launcher was changed to a port that is located 157.5° toroidally from the 4.6 GHz LH system and is not magnetically connected.

Numerical Hydrodynamic Modeling Incorporating the Flow through Permeable Sea-Wall (투수성 호안의 해수유통을 고려한 유동 수치모델링)

  • Bang, Ki-Young;Park, Sung Jin;Kim, Sun Ou;Cho, Chang Woo;Kim, Tae In;Song, Yong Sik;Woo, Seung-Buhm
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.2
    • /
    • pp.63-75
    • /
    • 2013
  • The Inner Port Phase 2 area of the Pyeongtaek-Dangjin Port is enclosed by a total of three permeable sea-walls, and the disposal site to the east of the Inner Port Phase 2 is also enclosed by two permeable sea-walls. The maximum tidal range measured in the Inner Port Phase 2 and in the disposal site in May 2010 is 4.70 and 2.32 m, respectively. It reaches up to 54 and 27%, respectively of 8.74 m measured simultaneously in the exterior. Regression formulas between the difference of hydraulic head and the rate of interior water volume change, are induced. A three-dimensional numerical hydrodynamic model for the Asan Bay is constructed incorporating a module to compute water discharge through the permeable sea-walls at each computation time step by employing the formulas. Hydrodynamics for the period from 13th to 27th May, 2010 is simulated by driving forces of real-time reconstructed tide with major five constituents($M_2$, $S_2$, $K_1$, $O_1$ and $N_2$) and freshwater discharges from Asan, Sapkyo, Namyang and Seokmoon Sea dikes. The skill scores of modeled mean high waters, mean sea levels and mean low waters are excellent to be 96 to 100% in the interior of permeable sea-walls. Compared with the results of simulation to obstruct the flow through the permeable sea-walls, the maximum current speed increases by 0.05 to 0.10 m/s along the main channel and by 0.1 to 0.2 m/s locally in the exterior of the Outer Sea-wall of Inner Port. The maximum bottom shear stress is also intensified by 0.1 to 0.4 $N/m^2$ in the main channel and by more than 0.4 $N/m^2$ locally around the arched Outer Sea-wall. The module developed to compute the flow through impermeable seawalls can be practically applied to simulate and predict the advection and dispersion of materials, the erosion or deposion of sediments, and the local scouring around coastal structures where large-scale permeable sea-walls are maintained.

Off-Pump Total Arterial Revascularization Using the Skeletonized Right Gastroepiploic Artery as a Third Arterial Conduit; Early and Midterm Results (제3동맥 도관으로서의 골격화된 우위대망동맥을 사용하여 시행한 심폐바이패스를 사용하지 않는 관상동맥 우회술;초기 및 중기 결과)

  • 이현주;최재성;김기봉
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.659-665
    • /
    • 2003
  • The aim of this study was to evaluate the early and midterm results of off-pump total arterial revascularization using the skeletonized right gastroepiploic artery (RGEA) as a third arterial conduit. Material and Method: We prospectively analyzed 103 patients who underwent off-pump total arterial revascularization using bilateral internal thoracic arteries (ITAS) and RGEA. The RGEA was used as in situ graft in 88 patients, composite graft in 10 patients, and free graft in 5 patients. Postoperative coronary angiographies were performed before discharge in 100 patients, and at postoperative one year in 88 patients. Result: The RGEA showed a significantly higher free flow (130$\pm$95 ml/min) than that of right ITA(113$\pm$57 ml/min) or left ITA (107$\pm$55 ml/min), which was measured before anastomosis (p < 0.05). The total number of distal anastomoses was 3.8$\pm$0.7. The number of distal anastomoses per bilateral ITAs was 2.8$\pm$0.7 and the number of distal anastomosis per RGEA was 1.0. There were two morialities including one operative mortality. The late mortality was not related to cardiac events. Early postoperative morbidities were atrial fibrillation in 15 patients, bleeding reoperation in 4 patients, mediastinitis in 1 patients, perioperative myocardial infarction in 2 patient, and transient ARF in 3 patients. Postoperative coronary angiographies showed the early patency rate of 98.6% (272/276) for ITAs and 97.0% (97/100) for RGEA, respectively (p=ns), and the one-year patency rate of 95.9% (234/244) for ITAs and 88.6% (78/88) for RGEA, respectively (p=0.07). Flow competition between the RGEA and NCA (native coronary artery) was seen in 5 of the 100 patients (5.0%) immediate postoperatively and 7 of the 88 patients (8.0%) 1 year after surgery. Since July, 2000, we measured transit time flow intraoperatively and could reduce flow competition significantly Conclusion: The skeletonized RGEA demonstrated excellent early and midterm patency rates and could be used as a third arterial graft following the bilateral ITAs.

Sleep Quality and Sleep Patterns of Patients Treated by the Hemopoietic Stem Cell Transplantation (조혈모세포 이식환자의 입원 후 수면의 질과 수면양상의 변화)

  • Choi, So-Eun;Park, Hae-Ryung;Park, Ho-Ran
    • Journal of Hospice and Palliative Care
    • /
    • v.8 no.1
    • /
    • pp.37-44
    • /
    • 2005
  • Purpose: To provide the basic data in developing the nursing intervention for patients who have symptoms of insomnia after undergoing hemopoietic stem cell transplantation (HSCT). This was achieved through investigating sleep quality and sleep patterns according to admission time, and discharge time. Methods: Data was put together by studying 52 HSCT patients who have been admitted to the department of HSCT from August 2002 to August 2003, in a university hospital. Research instruments used were, PSQI for sleep quality and a specified questionnaire for sleep patterns. Results: The PSQI regarding the past mono which was measured at the last day of hospitalization, was 11.8. This was significantly higher than 5.3, which was a measurement for the past month before the hospitalization (t=11.41, P=0.000). Looking at it with 7 categories-quality of sleep, consistency of sleep, sleep period, effectiveness of sleep, sleeping disorder, usage of sleeping pills, impediment of daily life- the PSQI for a month after admission increased significantly compared to the rate measured for a month before admission. Comparing the subjects sleep pattern before and after admission, it showed a significant difference regarding time attending sleep, time it takes to sleep, wake-up time, total time of sleep, day time sleep, number of times waking up during sleep, number of usage of sleeping pills, actions that are taken during sleep disorder, reasons for insomnia. Conclusion: The PSQI score of patients who undergo hemopoietic stem cell transplantation have increased significantly after hospitalization. Compared to the change of sleep patterns when hospitalized, significant changes were observed. Therefore nursing interventions addressing sleep are needed.

  • PDF

Application of Geophysical Methods to Detection of a Preferred Groundwater Flow Channel at a Pyrite Tailings Dam (황철석 광산 광미댐에서의 지하수흐름 경로탐지를 위한 물리탐사 적용)

  • Hwang, Hak Soo
    • Economic and Environmental Geology
    • /
    • v.30 no.2
    • /
    • pp.137-142
    • /
    • 1997
  • At the tailings dam of the disused Brukunga pyrite mine in South Australia, reaction of groundwater with the tailings causes the formation and discharge of sulphuric acid. There is a need to improve remediation efforts by decreasing groundwater flow through the tailings dam. Geophysical methods have been investigated to determine whether they can be used to characterise variations in depth to watertable and map preferred groundwater flow paths. Three methods were used: transient electromagnetic (TEM) soundings, direct current (DC) soundings and profiling, and self potential (SP) profiling. The profiling methods were used to map the areal extent of a given response, while soundings was used to determine the variation in response with depth. The results of the geophysical surveys show that the voltages measured with SP profiling are small and it is hard to determine any preferred channels of groundwater flow from SP data alone. Results obtained from TEM and DC soundings, show that the DC method is useful for determining layer boundaries at shallow depths (less than about 10 m), while the TEM method can resolve deeper structures. Joint use of TEM and DC data gives a more complete and accurate geoelectric section. The TEM and DC measurements have enabled accurate determination of depth to groundwater. For soundings centred at piezometers, this depth is consistent with the measured watertable level in the corresponding piezometer. A map of the watertable level produced from all the TEM and DC soundings at the site shows that the shallowest level is at a depth of about 1 m, and occurs at the southeast of the site, while the deepest watertable level (about 17 m) occurs at the northwest part of the site. The results indicate that a possible source of groundwater occurs at the southeast area of the dam, and the aquifer thickness varies between 6 and 13 m. A map of the variation of resistivity of the aquifer has also been produced from the TEM and DC data. This map shows that the least resistive (i.e., most conductive) section of the aquifer occurs in the northeast of the site, while the most resistive part of the aquifer occurs in the southeast. These results are interpreted to indicate a source of fresh (resistive) groundwater in the southeast of the site, with a possible further source of conductive groundwater in the northeast.

  • PDF

Survey of Current Status of the Patients with Home Ventilator in Seoul and Kyunggi Province (가정용 인공호흡기를 사용하는 서울 및 경기 지역 환자의 실태)

  • Ahn, Jong-Joon;Lee, Ki-Man;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.5
    • /
    • pp.624-632
    • /
    • 2000
  • Background : Home ventilation can decrease hospital-acquired infection, increase physical activity, improve nutritional status, enhance quality of life, and reduce medical costs. The number of patient using home ventilators has been increasing, particularly in Europe and United States. Although the number of patients with home ventilation has been increasing in Korea, the current status of these patients is not well known. This study was undertaken to obtain basic information upon these patients in addition to evaluating any problems related to patients' home care in our country. Methods : A register of 92 patients with home ventilators in Seoul and Kyunggi Province were obtained from commercial ventilator supply companies. The patients were contacted by phone and 29 of them accepted our visit. Information concerning education about home care before discharge, equipment cost, and problems related to home care were documented. The mode and preset variables of the home ventilator were checked; tidal volume (TV), peak airway pressure, and oxygen saturation were measured. Results : There were 26 males (90%) and their mean age was 48.0 (${\pm}20.1$) years. The underlying diseases were : 21 neuromuscular disorders, 2 spinal cord injuries, 6 chronic lung diseases. Among the caregivers, spouses (n=14) predominated. Education for home care before discharge was performed primarily by intensive care unit nurses and the education for ventilator management by commercial companies. Twenty-five of the 29 patients had tracheostomies. Volume targeted type (VTT ; n=20, 69%) was more frequently used than the pressure targeted type (PTT). Twenty-three of the 29 patients purchased a ventilator privately, which cost 7,450,000 (${\pm}$3,290,000) won for a PTT, and 14,280.000 (${\pm}$3,130,000) won for a VTT. Total cost for the equipment was 11,430,000 (${\pm}$634,000) won. The average cost required for home care per month was 1,120,000 (${\pm}$1,360, 000) won. Conclusion : The commonest underlying disease of the patients was neuromuscular disease. The VTT ventilator was primarily used with tracheostomy. Patients and their families considered the financial difficulties associated with purchasing and maintaining equipment for home care an urgent problem. Some patients were aided by a visiting nurse, however most patients were neglected and left without professional medical supervision.

  • PDF

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Long-term Variation and Flux of Organic Carbon in the Human-disturbed Yeongsan River, Korea (영산강의 유기물 플럭스와 장기변동에 대한 연구)

  • CHO, HYEONG-CHAN;CHO, YEONG-GIL
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.22 no.4
    • /
    • pp.187-198
    • /
    • 2017
  • Dissolved and particulate organic carbon concentrations and fluxes were measured and estimated for the Yeongsan River during 2006~2015. The dissolved organic carbon (DOC) concentrations ranged from 2.49 to $4.39mg{\cdot}C/L$ with a variance of 30.1% (${\sigma}_x/\bar{x}$), and showed a simple correlation to algal bloom and precipitation. The particulate organic carbon (POC) concentrations had gradually decreased from 6.68 to $0.19mg{\cdot}C/L$ for 10 years, and changed definitely with weir construction in 2011. Based on the relationships between POC and suspended particulate matters and between POC and chlorophyll-a, we found out that the distinct variation of the origin and composition of POC was caused by stagnation and screening effect of the dammed river. The total organic carbon (TOC) concentrations dropped to 52.3% (from 8.26 to $3.94mg{\cdot}C/L$) as the POC concentrations diminished to more than 94.8% after weir construction, in which the DOC forms up to 90.9%. The fluxes of TOC, based on the relationship between the annual TOC concentration and the discharge of Yeongsan dike sluice, were $2.56{\sim}19.41{\times}10^9g{\cdot}C/yr$, and showed a great deal of variability in 2011. Since then the TOC flux dropped to $5.40{\times}10^9$ (2011~2015) from $14.54{\times}10^9g{\cdot}C/yr$ (2006~2010). These results suggest that the weirs trapped annually $1.83{\times}10^9g{\cdot}C$ on a river bed, but released in great levels of dissolved organic form at their exits.