• 제목/요약/키워드: Measured Frequency

검색결과 7,633건 처리시간 0.041초

자동기록식 수중청음기를 이용한 저주파 해양잡음의 측정 (Measurement of Low-Frequency Ocean Noise by a Self-Recording Hydrophone)

  • 김봉채;김병남;조홍상
    • Ocean and Polar Research
    • /
    • 제29권4호
    • /
    • pp.311-316
    • /
    • 2007
  • Ocean noise may be used for monitoring wind speed and rainfall rate on the sea surface, as well as for tracking whales' migration routes. In particular, low-frequency ocean noise has recently been of concern with relation to the behavior of marine mammals. Low-frequency ocean noise has been increasing over the past few decades due to increase of ship traffic and offshore oil industry activities. Mechanical noise such as flow noise and cable strumming noise may be induced if low-frequency ocean noise is measured by cabled traditional hydrophone in high current areas. To successfully measure low-frequency ocean noise in a shallow water environment with strong current, we developed a self-recording hydrophone. This paper describes the main configurations of the self-recording hydrophone and presents some results on measured data.

음향주파수 분석에 의한 엔드밀의 마모상태 추정에 관한 연구 (A study on the Wear Estimation of End Mill Using Sound Frequency Analysis)

  • 조택동;이창희;손장영
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2002년도 하계학술발표대회 논문집 제21권 1호
    • /
    • pp.209-212
    • /
    • 2002
  • The wear process of end mill is a so complicated process that a more reliable technique is required for the monitoring and controling the tool life and its performance. This research presents a new tool wear monitoring method based on the sound signal generated on the machining. The experiment carried out continuous-side-milling for 4 cases using the high-speed steel slot drill under wet condition. The sound pressure was measured at 0.5m from the cutting zone by a dynamic microphone, and was analyzed at frequency domain. The tooth passing frequency appears as a harmonics form, and end mill wear is related with the first harmonic. It can be concluded from the result that the tool wear is correlate with the intensity of the measured sound at tooth passing frequency estimation of end mill wear using sound is possible through frequency analysis at tooth passing frequency under the given circumstances.

  • PDF

헤어핀 초전도체 필터와 구리 필터의 주파수 응답비교 (Comparison frequency responses of hairpin type superconducting and copper bandpass filters)

  • 박정호;송석천;이상렬
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.798-801
    • /
    • 2000
  • For the performance enhancement of communication system, high quality filters are required. Also a minimization of size of filter is required for the interation of devices in the limited area. Conventional metal filters made of copper can be substituted by high quality high temperature superconducting(HTS) films for better performance. Hairpin type filters have been designed with the center frequency 14 GHz for the size reduction. 3-pole and 4-pole filters centered at 14 GHz with the bandwidth of about 300 MHz were designed and fabricated. With the simulation results, the frequency responses showed low insertion loss and sharp skirts characteristics. The frequency response of HTS 14 GHz fi1ter was measured at 77 K and compared with the simulation results. We have compared YBCO filters and copper filters which were made with the same design rules. Simulated and measured frequency responses reveal that HTS YBCO hairpin type bandpass filters show better performance than copper filters.

  • PDF

Frequency-dependent grounding impedance of the counterpoise based on the dispersed currents

  • Choi, Jong-Hyuk;Lee, Bok-Hee;Paek, Seung-Kwon
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권4호
    • /
    • pp.589-595
    • /
    • 2012
  • When surges and electromagnetic pulses from lightning or power conversion devices are considered, it is desirable to evaluate grounding system performance as grounding impedance. In the case of large-sized grounding electrodes or long counterpoises, the grounding impedance is increased with increasing the frequency of injected current. The grounding impedance is increased by the inductance of grounding electrodes. This paper presents the measured results of frequency-dependent grounding impedance and impedance phase as a function of the length of counterpoises. In order to analyze the frequency-dependent grounding impedance of the counterpoises, the frequency-dependent current dissipation rates were measured and simulated by the distributed parameter circuit model reflecting the frequency-dependent relative resistivity and permittivity of soil. As a result, the ground current dissipation rate is proportional to the soil resistivity near the counterpoises in a low frequency. On the other hand, the ground current dissipation near the injection point is increased as the frequency of injected current increases. Since the high frequency ground current cannot reach the far end of long counterpoise, the grounding impedance of long counterpoise approaches that of the short one in the high frequency. The results obtained from this work could be applied in design of grounding systems.

6.0~18.0 GHz 주파수용 광대역 DFD 위상 상관기 설계 및 제작 (Design and Fabrication of Wideband DFD Phase Correlator for 6.0~18.0 GHz Frequency)

  • 최원;구경헌
    • 한국항행학회논문지
    • /
    • 제18권4호
    • /
    • pp.341-346
    • /
    • 2014
  • 본 논문은 6.0~18.0 GHz 대역에서 동작하는 광대역 디지털 주파수 변별기(DFD, digital frequency discriminator)의 위상 상관기(phase correlator)를 설계하고 제작하였으며, 제작된 DFD 위상 상관기의 I와 Q 신호를 측정하고, 주파수 변별 오차를 분석하였다. 믹서형 위상 상관기의 동작 특성에 대한 해석적 관계식을 유도하였으며, 위상 상관기에 포함되는 IQ 믹서(mixer)와 8-way 전력분배기(power divider)는 RF 시뮬레이션 툴(tool)을 이용하여 모델링하였다. 설계된 위상 상관기는 제작되어 측정하였다. 제작된 위상 상관기의 I와 Q 출력신호를 측정하여 제시하였으며, 측정된 I와 Q 출력신호를 이용하여 위상오차(phase error)와 주파수 변별오차(frequency discrimination error)를 나타내었다. 위상 상관기의 평균 위상오차(phase error)는 $4.81^{\circ}$, RMS(root mean square)이고, 주파수 변별 오차는 1.49 MHz, RMS 이다.

자동차 도어 진동의 파워흐름해석에 대한 실험적 연구 (Experimental Study on Power Flow Analysis of Vibration of an Automobile Door)

  • 길현권;이용현;이규형;황성국;홍석윤;박영호;서진관;채기상;서성훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.782-785
    • /
    • 2006
  • The Power Flow Analysis(PFA) can be effectively used to predict structural vibration in medium-to-high frequency range. In this paper, Power Flow Finite Element Method (PFFEM) based on PFA has been used to predict the vibration of an automobile door. The predicted results for the frequency response function of the door have been compared with corresponding experimental results. In the experiment, the automobile door has been divided into several subsystems and the loss factor of each subsystem has been measured. The input mobility at a source point has been also measured. The data for the loss factors and the input mobility have been used as the input data to predict the vibration of the automobile door with PFFEM. The frequency response functions have been measured over the surface of the door. The comparison between the experimental results and the predicted results for the frequency response functions showed that PFFEM could be an effective tool to predict the structural vibration.

  • PDF

하이힐을 자주 착용하는 20대 여성의 허리, 무릎, 발목 및 발가락 통증, 다리 길이 그리고 족저압과의 상관분석 (An Analysis of the Correlation between High Heels and Pain in the Low Back, Knee, Ankle and Toe, Length of Legs, and Plantar Pressure among Women in Their Twenties.)

  • 이민우;정연우
    • 대한정형도수물리치료학회지
    • /
    • 제26권2호
    • /
    • pp.11-18
    • /
    • 2020
  • Background: The purpose of this study is to examine the correlation between high heels and body imbalance among female college students in their twenties who mainly wear high heels and prevent associated problems. Methods: The subjects included 89 female college students in their twenties. They were measured in plantar pressure with a gait analyzer. Their legs were measured in length with a tape measure. Their pain intensity and pain frequency were measured in visual analog scale and in pain rating score. Results: There were statistically positive correlations between right leg length and low back pain frequency (p<.05) and negative correlations between the left hindfoot and low back pain frequency (p<.05). There were statistically positive correlations between right leg length and knee pain frequency (p<.05) and positive correlations between the ankle pain intensity and right leg length (p<.05). Conclusion: The stronger the pain was in the ankle, the stronger and more frequent their lumber pain was. When the pressure of the left heel was lower, the frequency of lumbar pain increased.

눈의 공간주파수와 대비 민감도 함수(CSF) 특성에 대한 연구 (Contrast Sensitivity as a Function of Spatial Frequency for 12 Year Old Child-Eye)

  • 김용근;박상안
    • 한국안광학회지
    • /
    • 제4권1호
    • /
    • pp.63-68
    • /
    • 1999
  • 공간주파수에 따른 contrast sensitivity를 측정할 수 있는 새로운 방법으로 차트를 제작하기 위해 차트 화면 최대 luminance값을 100%로 하여, 격자주파수의 mean luminance를 25, 50, 75%의 3개형태로 만들어 CS값 0 에서 $10^3$ 값이 되도록 하였다. 초등학생 5학년을 대상으로 공간주파수에 따른 CS값의 측정결과 평균 luminance 값이 떨어질수록 CS값은 감소되고, peak 위치도 low spatial frequency 쪽으로 이동하였다. 약시인 사람은 고주파수쪽에서 CS가 감소하거나, 전체주파수 공간에서 CS값이 감소하였다. 격자순응에 의해 CS 측정값은 순응된 공간주파수의 주변 영역에서 CS가 감소된다.

  • PDF

서보밸브의 주파수 응답 신호에 관한 연구 (A Study on the Frequency Response Signals of a Servo Valve)

  • 윤홍식;김성동
    • 드라이브 ㆍ 컨트롤
    • /
    • 제18권1호
    • /
    • pp.17-23
    • /
    • 2021
  • The flow signal or spool position signal is used to determine the dynamic characteristics of directional control valves. Alternatively, the signal of spool position or flow can be replaced with the velocity of a low friction, low inertia actuator. In this study, the frequency response of the servo valve equipped with a spool position transducer is measured with a metering cylinder. The input signal, spool displacement, load pressure, and velocity of the metering cylinder are measured, and the theoretical results from the transfer function analysis are verified. The superposition rule for magnitude ratio and phase angle was found to be always applicable among any signal type, and it was found that the load pressure signal is not appropriate for use as the signal for measuring the frequency response of a servo valve. It was confirmed that the frequency response of a servo valve using metering cylinder was similar to the results from a spool displacement signal. The metering cylinder used for measuring the frequency response of a servo valve should be designed to have sufficiently greater bandwidth frequency than the bandwidth frequency of the servo valve.

주상 변압기의 고주파 모델에 관한 연구 (A Study on the High Frequency Model of Pole-transformers)

  • 한병덕;오정환;임태훈;김현종;임춘백;김한수;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.464-466
    • /
    • 2000
  • In this paper, the high frequency models of pole-transformers are provided to confirm the feasibility of PLC systems between high and low voltage distribution systems. The impedance of transformers is measured to verify the characteristics of transformers at high frequency from 100[kHz] to 1[MHz] and the equivalent circuits of the transformers were designed based on the measured impedance. The signals transmitted from the primary and the secondary sides of the transformers were measured, respectively. The transmission loss of the transformers was obtained by the measured signals. Numerical analysis using the equivalent circuit is compared to the measured signals. The possibility of communication through pole-transformers is presented by experiments and simulations.

  • PDF