• Title/Summary/Keyword: Measure of evaluation

Search Result 3,413, Processing Time 0.031 seconds

Changes in CT Number and Noise Level according to Pitch in Spiral Image Acquisition (나선형영상획득에서 Pitch에 따른 CT 감약계수와 잡음의 변화)

  • Kang, SungJin
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.981-989
    • /
    • 2020
  • In this study, a self-made customized phantom was used to quantitatively measure the change in CT number and noise according to the change of pitch. In order to acquire an image using the phantom, the inside of the phantom was filled with sterile distilled water. Inside the glass tube, a solution obtained by diluting the ratio of normal saline and contrast medium to 100%(NS), 400:1, 200:1, 100:1, 50:1, respectively, was placed and imaged. At this time, the pitch was divided into steps of 0, 0.35, 0.7, 1.05, and 1.4 for each dilution ratio of the solution and imaged, respectively. One-way ANOVA analysis were performed to verify whether the mean of the CT number and noise values measured in all ROIs by dilution ratio showed a significant difference according to the change in pitch. As a result of the experiment, there was no statistically significant difference in the change of the CT number according to the change in the pitch for each dilution ratio, but the noise value tended to increase with the increase of the pitch, and showed a statistically significant difference. In the spiral image acquisition of CT, noise can be changed to a significant level depending on the pitch. Therefore, it will be necessary to set the quality evaluation items and criteria for CT images using the spiral image acquisition method.

Comparative analysis of distance measurement on the rendering screen between dental CAD programs (치과용 CAD 프로그램의 렌더링 화면상 거리측정 비교분석)

  • Cha, Cheol-Ho;Lim, Seon-Young;Bang, Ju-Hyuk;Kim, Seong-Ah;Kim, Seong-Yong;Lee, Yong-Sang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.11-17
    • /
    • 2021
  • Purpose: This study was to find out whether the rendering screen difference affect to measuring distance in a CAD program according to three types of CAD programs. Materials and methods: The model presented in ISO 12836 for dental scanner evaluation was reduced by 70%. This model was repeatedly scanned 15 times using Trios II (3Shape, Denmark). Using the output STL file, 3Shape CAD, inLab 15, and ExoCAD programs were used to measure the horizontal distance (H) and vertical distance (V) between adjacent point angle, and for each experiment, three groups were set according to the CAD program type. Statistical analysis was performed using One-way ANOVA test and post hoc was performed using Dunnett T3 test. Results: In the horizontal and vertical distance measurement, there was no difference in the average of the measured values between the three groups according to the CAD program (P>.05). Conclusion: There were no effect of the difference in the rendering screen in the horizontal and vertical linear distance measurements of the inlay model on the dental CAD program.

Evaluation of Dust Removal Efficiency on Roadway Structures Using Ultrafine Bubble Water Jet (초미세기포 water jet을 이용한 도로 시설물 분진 제거 효율 평가)

  • Kim, Hyun-Jin;Park, Il-gun
    • Clean Technology
    • /
    • v.27 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • A road structure washing vehicle equipped with a 4 HP, 80 LPM ultrafine bubble generator was used to clean a tunnel wall and the surface of the surrounding structure, consisting of concrete and tiles, in a heavy traffic area around an apartment complex in the city. Ultrafine bubbles were generated by supplying air at 2 to 3 LPM and using a specially designed nozzle, whereas fine bubbles made by an impeller in a gas-liquid mixing self-priming pump were produced with an average diameter of 165.4 nm and 6.81 × 107 particles mL-1. Using a high pressure washer gun that can perform high-pressure cleaning at 150 bar and 30 LPM, ultrafine bubbles were used to wash dust adsorbed on the surface of the road structures. The experimental analysis was divided into before and after washing. The samples were analyzed by applying ISO 8502-3 to measure surface contamination of dust adsorbed on the surface. Using the transparent tape attached to the surface, the removal rate was calculated by measuring the weight of the dust, and the number of particles was calculated using the gravimetric method and the software, ImageJ. The results of the experiment showed that the number of dust particles adsorbed on the tile wall surface before and after washing were 3,063 ± 218 particles mL-1 and 20 ± 5 particles mL-1, respectively, with weights of 580 ± 82 mg and 13 ± 4 mg. Particles on the surface of the concrete structure before and after washing were 8,105 ± 1,738 particles mL-1 and 39 ± 6 particles mL-1, respectively, with weights of 1,448 ± 190 mg and 118 ± 32 mg.

Development of regression functions for human and economic flood damage assessments in the metropolises (대도시에서의 인적·물적 홍수피해 추정을 위한 회귀함수 개발)

  • Lim, Yeon Taek;Lee, Jong Seok;Choi, Hyun Il
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.12
    • /
    • pp.1119-1130
    • /
    • 2020
  • Flood disasters have been recently increasing worldwide due to climate change and extreme weather events. Since flood damage recovery has been conducted as a common coping strategy to flood disasters in the Republic of Korea, it is necessary to predict the regional flood damage costs by rainfall characteristics for a preventative measure to flood damage. Therefore, the purpose of this study is to present the regression functions for human and economic flood damage assessments for the 7 metropolises in the Republic of Korea. A comprehensive regression analysis was performed through the total 48 simple regression models on the two types of flood damage records for human and economic costs over the past two decades from 1998 to 2017 using the four kinds of nonlinear equations with each of the six rainfall variables. The damage assessment functions for each metropolis were finally selected by the evaluation of the regression results with the coefficient of determination and the statistical significance test, and then used for the human and economic flood damage assessments for 100-year rainfall in the 7 metropolises. The results of this study are expected to provide the basic information on flood damage cost assessments for flood damage mitigation measures.

Classification of Diabetic Retinopathy using Mask R-CNN and Random Forest Method

  • Jung, Younghoon;Kim, Daewon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.12
    • /
    • pp.29-40
    • /
    • 2022
  • In this paper, we studied a system that detects and analyzes the pathological features of diabetic retinopathy using Mask R-CNN and a Random Forest classifier. Those are one of the deep learning techniques and automatically diagnoses diabetic retinopathy. Diabetic retinopathy can be diagnosed through fundus images taken with special equipment. Brightness, color tone, and contrast may vary depending on the device. Research and development of an automatic diagnosis system using artificial intelligence to help ophthalmologists make medical judgments possible. This system detects pathological features such as microvascular perfusion and retinal hemorrhage using the Mask R-CNN technique. It also diagnoses normal and abnormal conditions of the eye by using a Random Forest classifier after pre-processing. In order to improve the detection performance of the Mask R-CNN algorithm, image augmentation was performed and learning procedure was conducted. Dice similarity coefficients and mean accuracy were used as evaluation indicators to measure detection accuracy. The Faster R-CNN method was used as a control group, and the detection performance of the Mask R-CNN method through this study showed an average of 90% accuracy through Dice coefficients. In the case of mean accuracy it showed 91% accuracy. When diabetic retinopathy was diagnosed by learning a Random Forest classifier based on the detected pathological symptoms, the accuracy was 99%.

A Convergence Study of Surface Electromyography in Swallowing Stages for Swallowing Function Evaluation in Older Adults: Systematic Review (노인의 삼킴 단계별 삼킴 기능 평가를 위한 표면 근전도 검사의 융합적 연구 : 체계적 문헌고찰)

  • Park, Sun-Ha;Bae, Suyeong;Kim, Jung-eun;Park, Hae-Yean
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.5
    • /
    • pp.9-19
    • /
    • 2022
  • In this study, a systematic review was conducted to analyze the method of applying sEMG to evaluate the swallowing function of the elderly at each stage of swallowing, and to help objectively measure the swallowing stage of the older adults in clinical practice. From 2011 to 2021, 7 studies that met the selection criteria were selected using Pubmed, Scopus, and Web of Science (WoS). As a result of this study, the older adults and adults were divided into an experimental group and a control group and the swallowing phase was analyzed using sEMG only for the older adults. sEMG was used to evaluate swallowing in the oral and pharyngeal stages, and the sEMG attachment site was attached to the swallowing muscle involved in each stage. The collected sEMG data were filtered using a bandpass-filter and a notch-filter, and were analyzed using RMS, amplitude, and maximum spontaneous contraction. In this study, it was found that sEMG can be used as a tool to objectively and quantitatively evaluate the swallowing function in stages. Therefore, it is expected that this study will activate various studies that incorporate sEMG to evaluate the swallowing function in stages.

A study on the location of microphones in measurement considering the frequency characteristics of elevator noise in households (세대 내 승강기 소음 주파수특성을 고려한 측정 시 마이크로폰 위치에 관한 연구)

  • Min-Woo Kang;Yang-Ki Oh
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.124-132
    • /
    • 2023
  • When the building becomes high, the number of households increases and they are adjacent to the elevator. So, frequency of use of elevators will increase. Elevator noise is bound to increase in the future. However, there are currently no legal standards for elevator noise or measurement and evaluation methods that can clearly measure elevator noise in Korea. Although some methods for measuring elevator noise are presented in KS F ISO 16032, this standard is not a standard established for elevator noise. It is a standard that integrates the overall measurement method of building equipment and equipment, and the position of the microphone is selected by the experimenter during measurement. Elevator noise is characterized by a low sound pressure level as the noise in the mid-low frequency band is important. However, even today, complaints from residents about elevator noise are increasing. In this study, the position of the microphone that can most sensitively pick up the elevator noise when measuring the elevator noise was studied. According to the distance from the wall and the height from the floor, a total of 9 microphone positions were measured and analyzed. As a result of the experiment, it was confirmed that the elevator noise has a very high influence in the 63 Hz band. The measured value at the center point was identified as a factor that lowered the overall elevator noise level value.

Development of an Algorithm for Dynamic Traffic Operations of Freeway Climbing Lane Toward Traffic Safety (교통안전성을 고려한 고속도로 오르막차로 동적운영 알고리즘 개발)

  • PARK, Hyunjin;YOUN, Seokmin;OH, Cheol
    • Journal of Korean Society of Transportation
    • /
    • v.34 no.1
    • /
    • pp.68-80
    • /
    • 2016
  • Interest in freeway truck traffic has increased largely due to greater safety concerns regarding truck-related crashes. The negative interactions between slow-moving trucks and other vehicles are a primary cause of hazardous conditions, which lead to crashes with larger speed variations. To improve operational efficiency and safety, providing a climbing lane that separates slow-moving trucks from higher performance vehicles is frequently considered when upgrading geometrics. This study developed an operations strategy for freeway climbing lanes based on traffic conditions in real time. To consider traffic safety when designing a dynamic strategy to determine whether a climbing lane is closed or open, various factors, including the level of service (LOS) and the percentage of trucks, are investigated through microscopic simulations. A microscopic traffic simulator, VISSIM, was used to simulate freeway traffic streams and collect vehicle-maneuvering data. Additionally, an external application program interface, VISSIM's COM-interface, was used to implement the proposed climbing lane operations strategies. Surrogate safety measures (SSM), including the frequency of rear-end conflicts and, were used to quantitatively evaluate the traffic safety using an analysis of individual vehicle trajectories obtained from VISSIM simulations with various operations scenarios. It is expected that the proposed algorithm can be the backbone for operating the climbing lane in real time for safer traffic management.

Nondestructive Interfacial Evaluation and fiber fracture Source Location of Single-Fiber/Epoxy Composite using Micromechanical Technique and Acoustic Emission (음향방출과 미세역학적시험법을 이용한 단일섬유강화 에폭시 복합재료의 비파지적 섬유파단 위치표정 및 계면물성 평가)

  • Park, Joung-Man;Kong, Jin-Woo;Kim, Dae-Sik;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.5
    • /
    • pp.418-428
    • /
    • 2003
  • Fiber fracture is one of the dominant failure phenomena affecting the total mechanical Performance of the composites. Fiber fracture locations were measured through the conventional optical microscope and the nondestructive acoustic emission (AE) technique and then were compared together as a function of the epoxy matrix modulus and the fiber surface treatment by the electrodeposition method (ED). Interfacial shear strength (IFSS) was measured using tensile fragmentation test in combination of AE method. ED treatment of the fiber surface enlarged the number of fiber fracture locations in comparison to the untreated case. The number of fiber fracture events measured by the AE method was less than optically obtained one. However, fiber fracture locations determined by AE detection corresponded with those by optical observation with small errors. The source location of fiber breaks by AE analysis could be a nondestructive, valuable method to measure interfacial shear strength (IFSS) of matrix in non-, semi- and/or transparent polymer composites.

Assessing the Factors Influencing Patient Satisfaction after Receiving Laser in situ Keratomileusis (LASIK) (라식수술 후 환자만족도에 영향을 미치는 요인)

  • Cho, Woo-Hyun;Kim, Ji-Yoon;Choi, Yoon-Chung;Lee, Jong-Ho;Lee, Je-Myung;Kang, Hye-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.37 no.2
    • /
    • pp.111-119
    • /
    • 2004
  • Purpose : To identify those factors influencing the post-operative satisfaction in myopia patients receiving laser in situ keratomileusis (LASIK) Methods : This study included 288 consecutive patients who received LASIK between July and December 2001 from two eye clinics located in Seoul and Pusan. Factors that were considered to influence post-operative satisfaction included pre-operative baseline characteristics, pre-operative expectation for treatment outcomes, and treatment outcomes. Before undergoing LASIK, study subjects were asked to rate the degree of their expectation for the improvement of visual functions and symptoms after LASIK on a 5-point Likert-type scale: where 1 referred to 'somewhat worse,' 2 to 'no change,' 3 to 'somewhat improved,' 4 to 'improved,' and 5 to 'very improved.' Self-administered questionnaire was used to evaluate baseline visual functions and symptoms on a 5-point scale before LASIK. At 6 months after LASIK, the evaluation was repeated to measure treatment outcomes in terms of the difference in the score before and after LASIK. Post-operative satisfaction was also measured at 6 months on a 5-point scale. Multiple regression analysis was performed to examine the independent relationship between influencing factors and postoperative satisfaction. Results : A total of 171 patients (59.4%) participated in the 6-month follow-up investigation. The average expectation scores for the improvement in visual functions and symptoms were 3.8 and 3.4, respectively. The average score for the 7 questions assessing satisfaction was 4.0. The results of the regression analysis showed that the post-operative satisfaction increased with improvement in the visual function ($\beta$=0.16, p<0.05) and symptoms ($\beta$=0.25, p<0.05), the degree of preoperative refractive error ($\beta$ =0.26-0.67, p<0.05) and in male patients ($\beta$=0.31, p<0.1). The pre-operative expectation was not a statistically significant factor in explaining postoperative satisfaction in the regression model. Conclusion : The finding from this study was that patients with very severe myopia tended to be more satisfied with the treatment than those with mild myopia, which implies that LASIK can be more beneficial to those suffering from a severe visual condition. Patient satisfaction was also significantly affected by the treatment outcomes experienced after LASIK. This suggests that improving the clinical outcome is the most fundamental requirement for the improvement of patient satisfaction.