• 제목/요약/키워드: Measure of evaluation

검색결과 3,438건 처리시간 0.041초

Foot Function Index와 Foot and Ankle Outcome Score의 기입방법 연구: 종이와 연필을 이용한 기입 방법과 전자기기를 이용한 두 가지 측정방법에 대한 일치도 비교 (The Methods for Foot Function Index and Foot and Ankle Outcome Score Measurement: A Comparison between Paper-and-Pencil Method and Electronic Method)

  • 김지범;권민수;김정곤;이영;이우천;하정구;장석환
    • 대한족부족관절학회지
    • /
    • 제21권1호
    • /
    • pp.33-38
    • /
    • 2017
  • Purpose: The patient-reported outcome measure (PROM) is used to quantify the subjective state of patients before and after the treatment. The electronic method was recently developed and used for the completion of PROM, in addition to the conventional paper and pencil method. This study identified whether the results of Foot Function Index (FFI) and Foot and Ankle Outcome Score (FAOS) using the paper and pencil method was different from those using the electronic method. Materials and Methods: Between May 2016 and August 2016, 42 patients who were admitted to the Seoul Foot and Ankle Center two days before surgery were included for evaluation. The mean age was 46 years (range, 21~72 years). There were 29 males and 13 females. To use the electronic method, the PADAS software (PADAS, Seoul, Korea) was implemented using a touch pad. The primary trial of FFI and FAOS was performed using either the paper-and-pencil method or the electronic method. At 24 hours after the primary test, a secondary trial of FFI and FAOS was performed using the other method. Then, we identified the reliability of FFI and FAOS between the two methods by calculating the intraclass coefficient. Results: Twenty-two patients underwent the first trial using the paper-and-pencil method, and 20 patients underwent the first trial using the electronic method. Of the 42 patients, 8 patients were excluded from this study and only 34 patients were included in this study. The reliability of FFI was excellent with an intraclass coefficient of 0.957, and the reliability of FAOS was also excellent with an intraclass coefficient of 0.840. Conclusion: The paper-and-pencil method and the electronic method have the same result for the completion of FFI and FAOS in this study. Therefore, it is commonly considered that the completion of FFI and FAOS using the electronic method can be applied in practice.

Evaluation and Optimization of a Serum-based Minimum Inhibitory Concentration Assay to Caspofungin in Candida albicans Clinical Isolates

  • Yoo, Young Bin;Kim, Sung-Soon;Kim, Young Kwon;Kim, Sunghyun
    • 대한의생명과학회지
    • /
    • 제22권4호
    • /
    • pp.174-183
    • /
    • 2016
  • In the present study, a serum-based minimum inhibitory concentration (MIC) testing to caspofungin was optimized and evaluated to solve the limitations of the conventional Clinical and Laboratory Standards Institute (CLSI) guideline-based antifungal agent MIC test and the usefulness of this testing for clinical application was determined. A total of 105 Candida albicans clinical isolates were used for measuring MIC to caspofungin. Results showed that growth characteristics were different according to types of serum and the mouse serum was the most suitable for this assay. In order to measure the optimal concentration of mouse serum, 0 to 100% mouse serum were added to the media during fungal culture. The optimal concentration of serum was 50% when consideration of antifungal agent administration and inoculum size, serum components and ease of hyphae separated, and the consideration of the degree of growth. In comparison of the usefulness between the conventional Alamar-modified broth microdilution MIC assay and 50% mouse serum-based MIC testing, the range of $MIC_{80}$ of the Alamar-modified broth microdilution MIC assay was $0.13{\sim}2.0{\mu}g/mL$ (SD ${\pm}0.42{\mu}g/mL$) and that of the 50% mouse serum-based MIC assay was $2.0{\sim}32.0{\mu}g/mL$ (SD ${\pm}9.01{\mu}g/mL$). The range of $MIC_{50}$ of the Alamar-modified broth microdilution MIC assay was $0.13{\sim}2.0{\mu}g/mL$ (SD ${\pm}0.40{\mu}g/mL$) and that of the 50% mouse serum-based MIC assay was $1.0{\sim}16.0{\mu}g/mL$ (SD ${\pm}2.36{\mu}g/mL$). The MICs of 50% mouse serum-based MIC testing was increased by up to 4 to 64 times than Alamar-modified broth microdilution MIC assay. In conclusion, a 50% mouse serum-based MIC assay was more useful for measuring MIC in Candida albicans clinical isolates than conventional colorimetric broth microdilution MIC testing.

In Sacco Evaluation of Rumen Protein Degradation Characteristics and In vitro Enzyme Digestibility of Dry Roasted Whole Lupin Seeds (Lupinus albus)

  • Yu, P.;Egan, A.R.;Leury, B.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제12권3호
    • /
    • pp.358-365
    • /
    • 1999
  • The effects of dry roasting whole lupin seeds (lupinus albus, WLS) at 110, 130 or $150{^{\circ}C}$ for 15, 30 or 45 minutes on the in sacco rumen degradation characteristics, optimal heating conditions of time and temperature and in vitro enzyme digestibility were determined. Ruminant degradation characteristics (RDC) of crude protein (CP) of WLS were determined by in sacco technique in dairy cows. Measure ROC were soluble (S), undegradable (U), potentially degradable (D) fractions, lag time (TO) and rate of degradation (Kd) of insoluble but degradable fraction. Based on measured ROC, percentage bypass CP (%BCP) and bypass CP (BCP in g/kg, DM) were calculated. Degradability of CP was significantly reduced by dry roasting (p<0.001). The interaction of dry roasting temperature and time had significant effects on D (p<0.05), Kd (p<0.01), U (p<0.01), %BCP (p<0.001) and BCP (p<0.001) but not on S (p=0.923>0.05). With increasing time and temperature, S, D, Kd and U varied from 31.8%, 67.4%, 10.3%/h and 0.8% in the raw WLS (RWLS) to 27.1 %, 35.8%, 3.6%/h, 38.4% in $150{^{\circ}C}/45\;min$, respectively. All these effects resulted in increasing %BCP from 25.9 in RWLS to 61.0% in the $150{^{\circ}C}/45\;min$. Therefore BCP increased form 111.2 to 261.2 g/kg DM, respectively. Both %BCP and BCP at $150{^{\circ}C}/45\;min$ increased nearly 2.5 times over the RWLS. The effects of dry roasting on %BCP and BCP seemed to be linear up to the highest value tested. Although ROC had been altered by dry roasting, the In vitro perpsin-cellulase digestibility was generally unchanged. It was concluded that dry roasting was effective in shifting CP degradation from rumen to the lower gastrointestinal tract to potential reduce unnecessary N loss in the rumen. It might be of great value in successfully synchronizing the rhythms of release of nitrogen and energy in the rumen, thus achieving a more efficient fermentation of diets with high proportions of lignocellulosic resources. To determine the optimal dry roasting conditions, the digestibility of each treatment in the cows will be measured in the next trial using mobile bags technique.

에머지(Emergy) 개념을 이용한 산지가치의 계량화에 관한 연구 (A Study on the Quantification of Forest Land Values Using the Emergy Synthesis)

  • 김남국;김진이;박동기;이석모
    • 한국환경과학회지
    • /
    • 제17권3호
    • /
    • pp.305-314
    • /
    • 2008
  • As forest land takes up 65% of the Korean peninsula, there have been continuing conflicts between the development and conservation of forest land. As the income level has changed over time, the usage of forest land in society has changed. There has been increasing demands for forest land for urban development and recreational use. On the other hand, a large proportion of the land is required to be preserved for the forest and the natural ecosystem in it. The existing management system for the forest land has been designed focusing on the management of the trees on the land, and not the land itself. Due to this limitation, the current management system of forest land has failed to protect the forest land from being developed indiscreetly, making it difficult to conserve and develop the forest land in an efficient way. A major question in forest land management is how to integrate economic use activities with the supporting ecosystems to maximize performance of the ecological-economic system. In order to promote sustainable use of forest resources, and to achieve efficient forest land management, it is prerequisite to evaluation on forest resources of natural ecosystems. Quantitative measures are needed that signify how necessary the services and products of forested ecosystems are to human endeavors. In this study, the natural wealth provided by forest land was quantified based on emergy synthesis. Emergy is a universal measure of real wealth of the work of nature and society made on a common basis. Thus, Calculations of emergy provide a basis for making choices about environment and economy following the general public policy to maximize real wealth. The goals of forest land management to achieve balance between the ecology and economy of its integrated system and to foster equity among the diverse outcomes of the forest land were assessed with emergy. Emergy was demonstrated to holistically integrated and quantify the interconnections of a coupled nature-human system allowing the goals of ecological balance and outcome equity to be measured quantitatively. Doing so will provide a better understanding of the basis of forest land wealth and the consequences of management decisions.

Breast PET CT 영상 재구성 변화에 따른 대조도 대 잡음비와 신호 대 잡음비의 비교평가 (Evaluation and Comparison of Contrast to Noise Ratio and Signal to Noise Ratio According to Change of Reconstruction on Breast PET/CT)

  • 이재영;이을규;김기원;정회원;유광열;박훈희;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.79-85
    • /
    • 2017
  • 본 연구는 양전자 컴퓨터단층촬영(Positron Emission Computed Tomography; PET-CT) 유방암 영상에서 질환관심영역(Region of Interest; ROI)의 대조도 대 잡음비(Contrast to Noise Ratio; CNR)와 신호 대 잡음비(Signal to Noise Ratio; SNR)를 재구성 기법별로 측정 평가하여 통계적 분석을 하고자 하였다. 연구대상은 서울소재 대학병원에서 유방 양전자 컴퓨터단층촬영(Breast PET-CT)을 검사한 환자 100명이다. 측정방법은 ImageJ 프로그램을 사용하여 표본의 인구사회학적 특성, 영상 재구성 기법별 유방암의 SNR과 CNR의 평균값, 95% 신뢰구간 값, SNR과 CNR의 평균차이 값 등을 분석하였다. SPSS Statistics21 통계프로그램으로 ANOVA 분석을 하였으며 p<0.05에서 유의한 것으로 판단하였다. 영상 재구성 기법별 분석결과는 CNR과 SNR 모두 TrueX_TOF, Iterative, Iterative-TOF, FBP-TOF 순으로 높은 값을 나타냈다(p<0.05). CNR과 SNR수치로 영상 재구성 기법의 특징을 조합하여 PET/CT 검사의 정확성과 편의성을 제공할 것이라 사료된다.

Hitach-7600 P-module을 이용한 Methotrexate 정량분석 평가 (Quantitative Analysis of Methotrexate using Hitach-7600 P-module)

  • 김민의;차경호;김승희;김남주;채효진
    • 대한임상검사과학회지
    • /
    • 제41권4호
    • /
    • pp.167-172
    • /
    • 2009
  • Methotrexate (MTX) in one of the antineoplastic drug and it is known to effective to management of acute lymphoblastic leukemia in children, management of choriocarcinoma and related trophoblastic tumors in women, management of carcinomas of the breast, tongue, pharynx, and tests, maintenance of remission in leukemia and treatment of serve, debilitating psoriasis. Intermediate to high-dose methotrexate administration followed by leucovorin rescue is effective in treatment of carcinoma of the lung and osteogenic sarcoma. Intrathecal administration is effective in treating meningeal leukemia or lymphoma. There are FPIA (Fluorescence polarization immunoassay) and EMIT (Enzyme multiplied immunotechique) methods that measure for MTX. We evaluated the FPIA and EMIT methods. MTX were measured by Hitachi-7600 P-module using EMIT and FPIA using TDX in the sera 60 patients. The performance characteristics evaluated were, light influence, linearity, comparison with FPIA. Also, precision evaluated were three level controls through put following CLSI evaluation protocols (EP10-A). When the MTX value of $4.16{\pm}5.78{\mu}{\mu}mol/L$ (mean, SD) by the Hitachi-7600 P-module was compared with that of $4.05{\pm}5.47{\mu}{\mu}mol/L$ by FPIA, coefficients of correlation of 0.988 was obtained. The regression equation was Y (Hitachi-7600 P-module) = 0.9408 x (FPIA) + 0.1316 (r=0.9885, n=60). CVs of MTX measured by Hitachi 7600 P-module was 6.78% at $0.33{\mu}{\mu}mol/L$, 0.96% at $1.16{\mu}{\mu}mol/L$, and 0.96% at $8.04{\mu}{\mu}mol/L$. The precision was excellent in each group. The linearity was acceptable. We evaluated that MTX is light-sensitive on prolonged exposure to direct sunlight. Comparing with the FPIA using TDX, the Hitachi-7600 P-module using EMIT showed good coefficient of correlation and precision. Therefore the Hitachi-7600 P-module can replace the FPIA for quantitative analysis of MTX.

  • PDF

노출 모델의 화평법 적용성: ECETOC TRA와 Stoffenmanager Tier 1 노출 모델을 활용한 벤젠의 작업자 노출 평가 (Occupational Exposure Assessment for Benzene Using Exposure Models (ECETOC TRA and Stoffenmanager) and Applicability Evaluation of Exposure Models in K-REACH)

  • 문준식;옥정원;정욱현;나진성;김기태
    • 한국환경보건학회지
    • /
    • 제44권5호
    • /
    • pp.460-467
    • /
    • 2018
  • Objectives: The objectives of this study are to estimate the inhalation exposure level of benzene for workers using Tier 1 exposure models ECETOC TRA (European Center for Ecotoxicology and Toxicology of Chemicals Target Risk Assessment) and Stoffenmanager, and to investigate their reliability for exposure assessment in K-REACH. Methods: Two exposure scenarios, 'manufacture of benzene' and 'use as solvents,' were developed for assessment of workers' exposure to benzene. The Process Category (PROC) for ECETOC TRA was collected from the European Chemical Agency (ECHA) registration dossier, and the Activity for Stoffenmanager was converted from PROC using translation of exposure models (TREXMO). The information related to exposure, such as working duration, Respiratory Protective Equipment (RPE), Local Exhaust Ventilation (LEV), and Risk Management Measure (RMM) were classified into high, medium, and low exposure conditions. The risk was determined by the ratio of the estimated exposure and occupational exposure limits of benzene. Results: Under high exposure conditions, the worker exposure level calculated from all PROCs and Activities exceeded the risk level, with the exception of PROC 1 and Activity 1. In the medium exposure condition, PROC 8a, 8b, and 9 and Activity 3, 7, and 8 all exceeded the risk, whereas in the low condition, all PROCs and Activities were determined to be safe. As a result, action corresponding with the low exposure condition is required to reduce the risk of exposure among workers in workplaces where benzene is manufactured or used as a solvent. In addition, the predicted exposure levels derived from the exposure models were lower than measured levels. The exposure levels estimated from Stoffenmanager were more conservative than those from ECETOC TRA. Conclusions: This study demonstrates the feasibility of exposure models for exposure assessment through the example of occupational inhalation exposure assessment for benzene. For more active utilization of exposure models in K-REACH, the exact application of collected information and accurate interpretation of obtained results are necessary.

Implementation of AAPM's TG-51 Protocol on Co-60 MRI-Guided Radiation Therapy System

  • Cho, Jin Dong;Park, Jong Min;Choi, Chang Heon;Kim, Jung-in;Wu, Hong-Gyun;Park, So-Yeon
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.190-196
    • /
    • 2017
  • For the $ViewRay^{(R)}$ system (ViewRay Inc., Cleveland, OH, USA) which is representative of magnetic resonance (MR) guided radiotherapy machine, it is important to evaluate effectiveness of AAPM's TG-51 protocol and the effect of the magnetic field on absolute dosimetry. In order to measure the absolute dose, MR-compatible chamber and water phantom system manufactured in this study were used. The materials of the water phantom system were plastic of polymethyl methacrylate (PMMA) and non-ferrous materials. Due to the inherent feature of the $ViewRay^{(R)}$, all Co-60 sources are not located at gantry angle of $0^{\circ}$ while being located at gantry angle of $90^{\circ}$. For this reason, absolute dosimetry was performed based on the measurements in solid water phantom (SWP) and water which determine the SWP to water correction factor. For evaluation of output constancy with gantry angle, measurements were made with ionization chamber inserted in cylindrical water-equivalent phantom. For measured doses in water, the values of dose deviation according to a reference dose of 200 cGy for Head 1, Head 2 and Head 3 were -0.27%, -0.45% and -0.22%, respectively. For measured doses in SWP, the values of dose deviation according to a reference dose of 200 cGy for Head 1, Head 2 and Head 3 were -1.91%, -2.07% and -1.84%, respectively. All values of dose measured in SWP tended to be less than those measured in water by -1.63%. With the reference gantry angles of $0^{\circ}$ and $90^{\circ}$, the maximum values of deviation for Head 1, Head 2 and Head 3 were 0.48%, 1.06% and 0.40%, respectively. The measurement agreement is within the range of results obtainable for conventional treatment machines. The low strength of the magnetic field does not affect dose measurements. Using the SWP to water correction factor, absolute doses for $ViewRay^{(R)}$ system can be measured.

경기도 대기질 개선 정책의 온실가스 동시 저감 및 그에 따른 공편익 효과 분석 (Greenhouse Gas Reduction by Air Quality Management Policy in Gyeonggi-do and Its Co-benefit Analysis)

  • 김동영;최민애
    • 한국대기환경학회지
    • /
    • 제33권6호
    • /
    • pp.570-582
    • /
    • 2017
  • In recent years, national and local government's air quality management and climate change adaptation policy has been significantly strengthened. The measures in the two policies may be in a relationship of trade-off or synergy to each other. Greenhouse gases and air pollutants are mostly emitted from the same sources of using considerable amounts of fossil fuels. Co-benefits, in which either measure has a positive effect on the other, may be maximized by reducing the social costs and by consolidating the objectives of the various policies. In this study, the co-benefits were examined by empirically analyzing the effects of air pollutants and greenhouse gas emission reduction, social cost, and cost effectiveness between the two policies. Of the total 80 projects, the next 12 projects generated co-benefits. They are 1) extend restriction area of solid fuel use, 2) expand subsidy of low-$NO_x$ burner, 3) supply hybrid-vehicles, 4) supply electric-vehicles, 5) supply hydrogen fuel cell vehicles, 6) engine retrofit, 7) scrappage of old car, 8) low emission zone, 9) transportation demand management, 10) supply land-based electric of ship, 11) switching anthracite to clean fuel in private sector, 12) expand regional combined-energy supply. The benefits of air pollutants and greenhouse gas-related measures were an annual average of KRW 2,705.4 billion. The social benefits of the transportation demand management were the highest at an annual average of KRW 890.7 billion, and followed by scrappage of old cars and expand regional combined-energy supply. When the social benefits and the annual investment budgets are compared, the cost effectiveness ratio is estimated to be about 3.8. Overall, the reduction of air pollutants caused by the air quality management policy of Gyeonggi-do resulted in an annual average of KRW 4,790.2 billion. In the point sources management sector, the added value of $CO_2$ reduction increased by 4.8% to KRW 1,062.8 billion, while the mobile sources management sector increased by 3.6% to KRW 3,414.1 billion. If social benefits from $CO_2$ reduction are added, the annual average will increase by 7.2% to KRW 5,135.4 billion. The urban and energy management sectors have shown that social benefits increase more than twice as much as the benefits of $CO_2$ reduction. This result implies that more intensive promotion of these measures are needed. This study has significance in that it presents the results of the empirical analysis of the co-benefits generated between the similar policies in the air quality management and the climate change policy which are currently being promoted in Gyeonggi-do. This study suggested that the method of analyzing the policy effect among the main policies in the climate atmospheric policy is established and the effectiveness and priority of the major policies can be evaluated through the policy correlation analysis based on the co-benefits. It is expected that it could be a basis for evaluation the efficiency of the climate change adaptation and air quality management policies implemented by the national and local governments in the future.

무통제 교차로의 서비스수준 결정 방법론에 관한 연구 (Development of Methodology for the Analysis of Level-of-Service of Non-Controlled Intersections)

  • 김정현;김영찬
    • 대한교통학회지
    • /
    • 제21권5호
    • /
    • pp.31-40
    • /
    • 2003
  • 우리나라의 비신호교차로의 유형은 양방향정지식과 무통제식으로 분류될 수 있다. 무통제식은 국내외에서도 용량이나 서비스수준 분석에 관한 연구가 거의 전무하다. 본 연구에서는 이러한 유형의 무통제 교차로의 서비스 수준을 분석할 수 있는 방법론을 개발하는 것을 목표로 하였다. 우선 무통제 교차로의 서비스수준을 평가할 수 있는 효과척도 선정을 위한 분석을 수행하였다. 교통량, 상충횟수, 교차로 통행시간(지체) 등을 분석한 결과, 상충횟수과 교통량이 선형의 관계를 가지고 있는 것으로 나타나 이 2가지를 효과척도로 선정하였다. 서비스수준 E와 F의 경계가 되는 교통량(용량)은 1985 USHCM의 전방향정지식 교차로의 용량을 참고로 2000대/시로 하였으며 이때 상충횟수는 300회가 된다. 그리고 서비스수준별 상충횟수와 교통량을 용량상태를 기준으로 비례적으로 배분하였다. 교차로 총교통량으로 서비스수준을 결정할 때. 방향별 교통량비가 상충횟수에 영향을 주는 것으로 분석되어 방향별 교통량비에 대한 서비스 교통량을 보정하는 방법을 제안하였다.