• 제목/요약/키워드: Mean-line Analysis

검색결과 442건 처리시간 0.022초

Updating calibration of CIV-based single-epoch black hole mass estimators

  • Park, Daeseong;Barth, Aaron J.;Woo, Jong-Hak;Malkan, Matthew A.;Treu, Tommaso;Bennert, Vardha N.;Pancoast, Anna
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.61.1-61.1
    • /
    • 2016
  • Black hole (BH) mass is a fundamental quantity to understand BH growth, galaxy evolution, and connection between them. Thus, obtaining accurate and precise BH mass estimates over cosmic time is of paramount importance. The rest-frame UV CIV ${\lambda}1549$ broad emission line is commonly used for BH mass estimates in high-redshift AGNs (i.e., $2{\leq}z{\leq}5$) when single-epoch (SE) optical spectra are available. Achieving correct and accurate calibration for CIV-based SE BH mass estimators against the most reliable reverberation-mapping based BH mass estimates is thus practically important and still useful. By performing multi-component spectral decomposition analysis to obtained high-quality HST UV spectra for the updated sample of local reverberation-mapped AGNs including new HST STIS observations, CIV emission line widths and continuum luminosities are consistently measured. Using a Bayesian hierarchical model with MCMC sampling based on Hamiltonian Monte Carlo algorithm (Stan NUTS), we provide the most consistent and accurate calibration of CIV-based BH mass estimators for the three line width characterizations, i.e., full width at half maximum (FWHM), line dispersion (${\sigma}_{line}$), and mean absolute deviation (MAD), in the extended BH mass dynamic range of log $M_{BH}/M_{\odot}=6.5-9.1$.

  • PDF

평균곡률 구간법을 이용한 CMM 데이터의 경계 형성 연구 (A Study on the Edge Construction of CMM Data Using a Method of Mean Curvature Block)

  • 장병춘;김대일;오석형
    • 한국기계가공학회지
    • /
    • 제9권1호
    • /
    • pp.74-80
    • /
    • 2010
  • The purpose of reverse engineering design using 3D measurement data is an accurate reconstruction of real body. In oder to accomplish this object, it is important that creating exact extracting edges should be studying out first of all. This study used edge-based method to find out edge point from the measuring point data. The characteristics are analysed using the mean curvature block method on the fitting NURBS curve and defined edges through block removal condition. The results showed that only using the NURBS curve of maximum curvature analysis to define correct edge of real geometry is limited, but this segmentation approach provides simplified necessary condition for edge classification, and an effectiveness to classify a straight line, curves and fillets etc.

컴퓨터 작업 시 전방머리자세 교정장치의 효과 (The Effect of Forward Head Posture Correctional Device During Computer Work)

  • 이충휘;유원규;김민희
    • 한국전문물리치료학회지
    • /
    • 제13권1호
    • /
    • pp.9-15
    • /
    • 2006
  • Work-related musculoskeletal disorder has been associated with long hours of computer work and prolonged periods of static posture. In clinical settings, postural correction is a common treatment approach for individuals with neck, shoulder, and back pain. This study was designed to identify the effect of Forward Head Posture Correctional Device during computer work. Twelve healthy adults (mean age, 27.4 yrs; mean height, 165.0cm mean weight, 65.8 kg) participated in the study. They had no medical history of neurological or surgical problems with their upper extremity. The subjects were asked to perform Head Forward Posture under the guidance of physical therapists and the measured angles were analyzed using a 3-D motion analysis system. Markers were placed on the C7 spinous process, tragus of the ear and forward head angle was between the line from the tragus to the C7 line and the Y-axis at the C7. The statistical significance of difference between, "without" and "with" correctional device was tested by paired t-test. A level of significance was set at ${\alpha}$=.05. In comparison of the computer work between "without" and "with" correctional device, Forward Head Angle was showed significant difference (p<.05). In conclusion, the range of Forward Head Angle was significantly decreased during computer work with the correctional device. Further research is needed to understand the nature of motor control problems in deep muscles in patients with neck, shoulder, and back pain.

  • PDF

선형열원법에 의한 지중유효열전도도와 보어홀 전열저항 해석 (Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Line Source Method)

  • 이세균;우정선;노정근
    • 한국태양에너지학회 논문집
    • /
    • 제30권4호
    • /
    • pp.71-78
    • /
    • 2010
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. The line source method is required by New and Renewable Energy Center of Korea Energy Management Corporation in analyzing data obtained from thermal response tests. Another important factor in designing the ground loop heat exchanger is the borehole thermal resistance($R_b$). There are two methods to evaluate $R_b$ : one is to use a line source method, and the other is to use a shape factor of the borehole. In this study, we demonstrated that the line source method produces better results than the shape factor method in evaluating $R_b$. This is because the borehole thermal resistance evaluated with the line source method characteristically reduces the temperature differences between an actual and a theoretical thermal behaviors of the borehole. Evaluation of $R_b$ requires soil volumetric heat capacity. However, the effect of the soil volumetric heat capacity on the borehole thermal resistance is very small. Therefore, it is possible to use a generally accepted average value of soil volumetric heat capacity($=2MJ/m^3{\cdot}K$) in the analysis. In this work, it is also shown that an acceptable range of the initial ignoring time should be in the range of 8~16hrs. Thus, a mean value of 12 hrs is recommended.

남성복 바지원형의 자동제도에 관한 연구 (A Study on the Automatic Drafting of Basic Slacks Pattern for Young Men)

  • 석은영;김혜경
    • 한국의류학회지
    • /
    • 제20권1호
    • /
    • pp.54-65
    • /
    • 1996
  • The purposes of this study were 1) to present the optimum slacks pattern for young men, 2) to develope a methodology to draft basic slacks pattern using AutoCAD The total crotch legth and the shape of the crutch line were determined by anthropometric data analysis. The total crotch length was calculated with the waist girth, the hip girth and the crotch length measurements. The anthropometric data utilized for this procedure was National Anthropometric Survey of Korea, 1992. And multidimensional anthropometric measurements were carried out for 6 male college students between the age of 18 to 24. The subjects were measured with the Martin's anthropometer and the sliding gauge. Mean, standard deviation and t-test were performed for statistical analysis of the data. The automatic drafting method was programmed by AutoLISP in AutoCAD. The automatic drafting was based on the Muller's slacks pattern drafting method, the measurements of slacks construction components and the curve of crotch line. The crotch line was drafted using of the arc function in AutoCAD. The total crotch length was calcuated using the multiple regression equation. The experimental pattern developed to accomodate individual body wleasurements expected to produce customized apparel production in QRS(Quick Response System) production system.

  • PDF

안산시 주거지역을 중심으로 한 환경대기 중 휘발성 유기화합물과 황계열 성분의 온라인 연속측정 연구 (On-line GC Analysis of Odorous VOC and S Gas Pollutant Levels in Ambient Air of a Residential Area at Ansan City, Korea)

  • 김기현;주도원;최여진;홍윤정;사재환;박종호;전의찬;최청렬;구윤서
    • 한국대기환경학회지
    • /
    • 제21권1호
    • /
    • pp.107-118
    • /
    • 2005
  • In this study, the concentrations of major odorous compounds including reduced sulfur compounds (OMS, CS$_2$, and DMDS) and aromatic VOC (benzene, toluene, xylene, etc.) were measured continuously using an on-line GC analytical system. Our measurements were made from a residential area of Ansan sity during about two week period of October, 2004. The highest mean concentrations of Sand VOC were found as 56.9 pbb of DMS and 21.7 ppb of toluene, respectively. The results of this study generally show that the pollution levels for both types of chemicals are significant relative to previous measurement results reported from comparable sites, if the results are compared simply in terms of the magnitude of the measured concentration data. Moreover, when the relative importance of different compounds is compared in terms of the odor strength, it indicated that the contribution of reduced S compounds may be much more important than that of VOC in the study area.

안전한 임플란트 식립을 위한 하악골 내측면의 CBCT를 이용한 해부학적 연구 (An anatomical study on the mandibular medial surface by CBCT analysis for safer implant placement)

  • 이정교;김여갑
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권1호
    • /
    • pp.43-48
    • /
    • 2011
  • Introduction: This study examined the anatomical morphology of the medial surface of the posterior mandible using 3-dimensional cone-beam computed tomography (CT) images to reduce the number of complications related to dental implant placement. Materials and Methods: Fifty patients were enrolled in this study with an average age (${\pm}$standard deviation) of 44.28 (${\pm}13.05$). On the coronal views cone-beam CT of the first molars, the distance between the top of the canal and alveolar crest vertical distance (VD), the distance between the upper-most point of the canal and the point perpendicular to the lingual cortical margin of the mandible lingual distance (LD), the location of the starting point of VD for reducing from the vertical reference line (VD point), and the inclination of the mandibular medial surface (lingual inclination) were measured, and a statistical evaluation was performed using SPSS for Windows version 15.0. Results: The mean VD0 was $16.91{\pm}2.47\;mm$ and VDx decreased with increasing x value. The mean LD was $5.27{\pm}1.36\;mm$. The VD began to decrease at the mean location of $6.12{\pm}0.96\;mm$ from the vertical reference line. The mean lingual inclination was $1.52{\pm}0.72^{\circ}$. Conclusion: These results will assist in the accurate placement of dental implants and the reduction of complications, particularly in the case of preoperative implant planning using only 2-dimensional imaging methods. (ex. panoramic radiography)

상악중절치에서 전부도재관의 finish line형태에 따른 파절강도와 응력 분포에 관한 연구 (THE FRACTURE RESISTANCE AND STRESS DISTRIBUTION OF ALL CERAMIC CROWNS WITH TWO TYPES OF FINISH LINE ON MAXILLARY CENTRAL INCISOR)

  • 기태석;김계순;이진한;김유리;동진근
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.405-420
    • /
    • 2003
  • Purpose : The purpose of this study was to compare the fracture resistance of the IPS Empress ceramic crown with 1.0mm width rounded shoulder, which is usually recommended in all ceramic crown. and 0.5mm width chamfer finish lines on the maxillary central incisor. Material and method : After 15 metal dies were made for each group, the IPS Empress all ceramic crowns were fabricated and cemented with resin cement(Bistite resin cement, Tokuyama Soda Co. LTD., Japan) on the metal die. The cemented crowns were mounted on the positioning jig and the universal testing machine(Zwick Z020, Zwick Co. Germany)was used to measure the fracture strength with loading on the incisal edge. And also, three-dimensional finite element stress analysis was used to measure the stress distribution with the various types of the finish lines(1.0mm width rounded shoulder, 0.5mm width chamfer), the loading site(incisal edge, incisal $\frac{1}{3}$) and the type of loading(concentration loading, distribution loading). Results and conclusion : 1. In the fracture resistance experiment according to the finish line, the mean fracture strength of rounded shoulder(876N) and the mean fracture strength of chamfer(882N) did not skew any significant difference between each other(p>0.05). 2. The stress distribution of all ceramic crown in three dimensional finite element analysis showed concentration aspect at loading point and cervical area or labial surface. 3. In metal die, there were no differences in stress distribution between finish lines, but in natural teeth model, chamfer finish line showed higher stress than rounded shoulder finish line. 4. When force was loaded on the incisal edge the stress was concentrated on the incisal edge and the cervical area of labial surface. When force was loaded on the incisal $\frac{1}{3}$, the stress concentrated on the cervical area of labial surface and the cingulum area. 5. Generally, natural teeth model showed higher and various stress than the metal die.

메트로놈을 이용한 트레드밀 보행훈련이 보행패턴에 미치는 영향 (Effect of Treadmill Walking Training using the Metronome on Gait Pattern)

  • 윤원찬;박선욱
    • 대한물리의학회지
    • /
    • 제15권2호
    • /
    • pp.101-108
    • /
    • 2020
  • PURPOSE: The purpose of this study was to investigate the effect of treadmill walking training using the metronome on the gait pattern. METHODS: A total of 33 healthy persons were studied consisting of 17 female and 16 male in the 20-30 age group. A gait analysis program was installed on a treadmill with a built - in gait analysis sensor and laptop. After 9 minutes of treadmill walking, gait analysis was performed for 1 minute. The mean values of the differences in the step length, angle of COP, separation line standard deviation and step force of the lower legs affecting walking symmetry were calculated for treadmill walking and treadmill walking using the metronome. The Shapiro-Wilk test was used to test the normality of the collected data and a paired t-test was performed to analyze the difference in walking before and after using the metronome. RESULTS: As a result of the analysis, the mean of difference between the measured values of the bilateral lower extremity for step length, angle of COP, separation line standard deviation and step force were statistically significant before and after treadmill walking using the metronome. CONCLUSION: Therefore, the treadmill walking training using the metronome is effective in decreasing the difference in the foot width, gait angle, gait distribution, and foot pressure. Because of this, the treadmill walking training using the metronome has a significant effect on walking symmetry among the elements for correct walking, which is a means for enabling efficient and continuous walking.

A Novel Equivalent Wiener-Hopf Equation with TDL coefficient in Lattice Structure

  • Cho, Ju-Phil;Ahn, Bong-Man;Hwang, Jee-Won
    • Journal of information and communication convergence engineering
    • /
    • 제9권5호
    • /
    • pp.500-504
    • /
    • 2011
  • In this paper, we propose an equivalent Wiener-Hopf equation. The proposed algorithm can obtain the weight vector of a TDL(tapped-delay-line) filter and the error simultaneously if the inputs are orthogonal to each other. The equivalent Wiener-Hopf equation was analyzed theoretically based on the MMSE(minimum mean square error) method. The results present that the proposed algorithm is equivalent to original Wiener-Hopf equation. The new algorithm was applied into the identification of an unknown system for evaluating the performance of the proposed method. We compared the Wiener-Hopf solution with the equivalent Wiener-Hopf solution. The simulation results were similar to those obtained in the theoretical analysis. In conclusion, our method can find the coefficient of the TDL (tapped-delay-line) filter where a lattice filter is used, and also when the process of Gram-Schmidt orthogonalization is used. Furthermore, a new cost function is suggested which may facilitate research in the adaptive signal processing area.