• Title/Summary/Keyword: Mean current

Search Result 2,176, Processing Time 0.039 seconds

Electrical Characteristics of Helicon Wave plasmas (헬리콘 플라즈마의 전기적 특성)

  • 윤석민;김정형;서상훈;장흥영
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.1
    • /
    • pp.85-92
    • /
    • 1996
  • The external electricla characteristics of helicon wave plasmas were measured over a wide range of RF power and magnetic filed. External parameters. such as antenna voltage , current, phase shift, and interanl parameter, electron density were measured at 7MHz, 1mTorr Ar discharge . The equivalent discharge resistance and reactance, and the power transfer efficiency were calculated through these measurements. There are a helicon mode which produces high density plasma by helicon wave and a lowmode which produces low density plasma by capaictive electric field. In case of the helicon mode, the anternna voltage and current were lower than those of the low-mode. The phase difference between voltage and current decreased suddenly at the transition point from the low-mode to the helicon mode. Equivalent resistance and power efficiency increased and reactance decreased suddenly at the transition point. These results mean that the power transperred to plasma and the nutual coupling between the antenna and plasma increase as the mode changes from the low-mode to the helicon mode.

  • PDF

Scouring and accumulation by tidal currents around cubic artificial reefs installed at Geogeom waterway (거금수로에 시설된 사각형 인공어초 주변의 조류에 의한 세굴 퇴적 변화)

  • Kim, Dae-Kweon;Lee, Jin-Young;Suh, Sung-Ho;Kim, Chang-Gil;Cho, Jea-Kwon;Cha, Byung-Yul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1275-1280
    • /
    • 2009
  • Tidal currents were observed at 1 station of artificial reefs group during 15days. Maximum current was 82.4cm/s, and mean current showed 12.8~28.0cm/s, respectively. Flood currents magnitude were bigger than ebb ones due to wake region. To grasp sediment distributions, sediments were sampled at 4-direction(E, W, S, N) around each station. According to the results of sample analysis, sediments showed different distribution by main current direction. It showed that sediments distribution at front and back of artificial reefs were differently occurred by change of main current direction. It suggest that artificial reefs need to install after confirming tidal currents direction and sediments type.

Real-time estimation of arc stability in GMAW process (GMAW 공정에서 아크 안정성의 실시간 측정)

  • 원윤재;부광석;조형석
    • Journal of Welding and Joining
    • /
    • v.8 no.1
    • /
    • pp.31-42
    • /
    • 1990
  • Arc must be stable during welding first of all other factors for obtaining sound weldment, especially in the automation of welding process. Arc stability is somewhat sophisticated phenomenon which is not clearly defined yet. In consumable electrode welding, the voltage and current variation due to metal transfer enables to assess arc stability. Recently, statistical analyses of the voltage and current waveform factors are performed to assess the degress of arc stability which is assessed and controlled by operator's own experience by now. But, considering the increasing need and the trend of automation of welding process, it is necessary to monitor arc stability in real-time. In this sutdy, the modified stability index composed of two voltage and current wvaeform factors (arc time and short circuit time) reduced from four factors (arc time, short circuit time, average arc current and average short circuit current) in Mita's index by the welding electrical circuit modeling is proposed and verified by experiments to be well estimating arc stability in the static sense. Also, the recursive calculation form estimating present arc stability in the dynamic sense is developed for real-time estimation. The results of applying the recursive index during welding show good estimation of arc stability in real-time. Therefore, the results of this study offers the mean for real-time control arc stability.

  • PDF

Analysis of Cylinder Compression Pressure & Valve Timing by Motoring Current & Crank Signal during Cranking (모터링시 전류 파형과 크랭크각 센서를 이용한 기관의 압축압력 및 밸브 타이밍 분석)

  • Kim, In-Tae;Park, Kyoung-Suk;Shim, Beom-Joo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.5
    • /
    • pp.45-50
    • /
    • 2011
  • Compression pressure of individual cylinder and valve timing have big influence on combustion pressure, indicated mean effective pressure (IMEP), emission, vibration, combustion noise and many other combustion parameters. Conventional method, however, to check compression pressure uniformity is done by mechanical pressure gage and valve timing is checked manually. This conventional method causes inaccuracy of cylinder pressure measurement because of different cranking speed results from battery status and temperature. Also to check valve timing, related FEAD parts should be disassembled and timing mark should be checked. This study describes and suggests new methodology to measure compression pressure by analysis of start motor current and to check valve timing by cylinder pressure with high accuracy. Results, it is found that detection of bulky as well as small leaky cylinder is possible by cranking motor current analysis and wrong valve timing can be detected by cylinder pressure analysis and cam and crank sensor signal.

Effect of Joule Heating on Electromigration Characteristics of Sn-3.5Ag Flip Chip Solder Bump (Joule열이 Sn-3.5Ag 플립칩 솔더범프의 Electromigration 거동에 미치는 영향)

  • Lee, Jang-Hee;Yang, Seung-Taek;Suh, Min-Suk;Chung, Qwan-Ho;Byun, Kwang-Yoo;Park, Young-Bae
    • Korean Journal of Materials Research
    • /
    • v.17 no.2
    • /
    • pp.91-95
    • /
    • 2007
  • Electromigration characteristics of Sn-3.5Ag flip chip solder bump were analyzed using flip chip packages which consisted of Si chip substrate and electroplated Cu under bump metallurgy. Electromigration test temperatures and current densities peformed were $140{\sim}175^{\circ}C\;and\;6{\sim}9{\times}10^4A/cm^2$ respectively. Mean time to failure of solder bump decreased as the temperature and current density increased. The activation energy and current density exponent were found to be 1.63 eV and 4.6, respectively. The activation energy and current density exponent have very high value because of high Joule heating. Evolution of Cu-Sn intermetallic compound was also investigated with respect to current density conditions.

Changes of membrane resistance and membrane potentials by hyperpolarizing current stimulation in mouse unfertilized eggs (과분극 자극에 대한 mouse 미수정란의 세포막저항과 세포막전압의 변화)

  • Hong, Seong-geun;Kim, Ik-hyen;Cho, Young-deok
    • Korean Journal of Veterinary Research
    • /
    • v.31 no.1
    • /
    • pp.33-40
    • /
    • 1991
  • For the observations of both the membrane properties and the excitability on the unfertilized eggs of female mice, changes of the membrane resistance and the membrane potential by hyerpolarizing current stimulation were recorded. As current-voltage relation was linear over the entire range (-180mV~+60mV), membrane resistance($R_m$) was calculated from the amplitude of electrotonic potential to a given stimulus current. Also the presence of anode-break excitation was confirmed. The results were as follows; 1. There was a linear relation between the membrane resistance and resting membrane potential, the expected input resistance was 61. 4M$\Omega$(resting membrane potential was $-18.9{\pm}8.7mV$, mean${\pm}$SD, n=30). 2. Transient depolarization with overshoot was generated just after hyperpolarizing current stimulus and showed the dependency of stimulus duration. 3. Transient depolarization lasted over 30ms, amplitude of these depolarization was increased by high $Ca^{{+}{+}}$(20mM) and inhibited by $Ca^{{+}{+}}$-antagonist, $Mn^{{+}{+}}$. 4. From the above results, it was suggested that the unfertilized mouse egg showed the characteristics of the excitable cell.

  • PDF

The P300 Source Localization in the Patients with Obsessive-Compulsive Disorder using the LORETA Imaging and SPM (강박장애에서 LORETA 영상을 이용한 P300 국소원의 통계적 분석)

  • Park, Sung-Kun;Choi, Jung-Seok;Yu, Soh-Young;Lee, Bo Reom;Kang, Seung-Suk;Roh, Kyu Sik;Ha, Tae-Hyun;Kwon, Jun Soo
    • Korean Journal of Biological Psychiatry
    • /
    • v.10 no.2
    • /
    • pp.168-176
    • /
    • 2003
  • Objectives:We investigated the characteristics of P300 generators in obsessive-compulsive disorder(OCD) patients by using voxel-based statistical parametric mapping of current density images. Methods:P300 generators, produced by a rare target tone of 1500Hz under a frequent non-target tone of 1,000Hz, were measured in 15 right-handed OCD patients and 15 controls. Low Resolution Electromagnetic Tomography(LORETA), using a realistic head model of the boundary element method based on individual MRI, was applied to the 128-channel EEG. Statistical parametric mapping(SPM) was applied for the statistical analysis. Results:We found that both groups had the mean current density of P300 in the parietal, temporal and prefrontal lobe. There was a trend for decreased current density in the prefrontal area in OCD patients. The statistical comparison showed current density increase in the supraparietal area, a statistically significant longer P300 latency and a trend for reduced P300 amplitude in OCD patients. Conclusion:It suggests that P300 source of both groups exists in multiple brain regions at the same time. And both groups had no statistically significant differences in the current density of P300 except for increased current density in the supraparietal area in OCD patients. But, considering the statistically significant longer P300 latency, a trend for reduced P300 amplitude and relative mean current density reduction in the prefrontal area in OCD patients, this study suggests that the frontal lobe may have a reduced normal inhibitory process in OCD patients.

  • PDF

Periodic characteristics of long period tidal current by variation of the tide deformation around the Yeomha Waterway (염하수로 인근에서 조석 변형과 장주기 조류성분의 변동 특성)

  • Song, Yong-Sik;Woo, Seung-Buhm
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.5
    • /
    • pp.393-400
    • /
    • 2011
  • The mass transport is very complicated at the area which has the macro tide and complex geometry such as Gyeonggi bay. Especially, the long period current has a strong influence on the estuarine ecosystem and the long-term distribution of substances. The long period current is caused by several external forcing, whose unique characteristic varies spatially and temporally. The variation characteristics of long period current is analysed and its generation mechanism is studied. The tidal nonlinear constituents such as overtide and compound tide are generated due to nonlinear interaction and it causes mean sea level setup. The tidal wave propagating up into estuary is transformed rapidly by decrease of cross-sectional area and depth. Therefore the mean sea level is getting rise toward upriver. The high and low tide level is similar between down-river(Incheon) and up-river(Ganghwa) during neap tide when the tidal deformation is decreased. The tidal phase difference between two tidal stations causes a periodic fluctuation of sea level difference. The low water level of Ganghwa station during spring tide does not descend under EL(-)2.5 m, but the low water level of Incheon fall down under EL(-)4.0 m. The variation of tidal range and its sea level are increased during spring tide. It is found that the long period current $M_{sf}$ is quite similar to that of sea level difference between the two tidal stations. It means that the sea surface inclination caused by the spatial difference of tidal deformation is important forcing for the generation of long period current.

Current Status of Interval of Heparin Flushing for Maintenance of an Implanted Port in Solid Tumor Patients (고형암 환자의 삽입형 포트 개방성 유지를 위한 헤파린 관류 주기 현황)

  • Kim, Hye Kyung;Choi, So Eun;Lee, Jung Hoon;We, Eun Sook;Joh, Hye Jin;Kim, Kwang Sung
    • Journal of Korean Biological Nursing Science
    • /
    • v.16 no.3
    • /
    • pp.251-257
    • /
    • 2014
  • Purpose: Little is known about appropriate interval periods between the heparin flushing of implanted ports after completion of chemotherapy. The purpose of this study was to describe the current status of interval of heparin flushing for maintenance of an implanted port in solid tumor patients. Methods: We performed a retrospective review of all patients who had undergone implanted port removal in 2012 at the Seoul St. Mary's Hospital. The subjects were 90 patients who, after completion of chemotherapy, retained their ports for extended periods of time. Results: The mean number of flushes of heparin was 4. Compliance with visits for implanted port maintenance varied with the individual, and the mean accession times were in the range between 13 days and 243 days. The overall mean time between flushes was 66 days. One patient showed resistance during flushing. Conclusion: Our results demonstrate that extending the flushing interval to a maximum of 8 weeks remains medically safe. Less frequent heparin flushing of an implanted port decreases medical expenditure and the workload of medical professionals; it also improves the patient's satisfaction.

Fish Passage Assessments in the Fishway of Juksan Weir Constructed in the Downstream Area of Youngsan-River Watershed (영산강수계의 죽산보에 설치된 어도에서 어류의 이동성 평가)

  • Park, Chan-Seo;An, Kwang-Guk
    • Journal of Environmental Science International
    • /
    • v.23 no.8
    • /
    • pp.1513-1522
    • /
    • 2014
  • Fish passage asssessments were conducted in the fishway at Juksan Weir, which was constructed as a four-major rivers project in the downstream area of Youngsan-River Watershed. For the research, fish-movements/migrations were analyzed for seven times from April ~ October, 2013 using an approach of fish trap-setting. Fish fauna and compositions were analyzed in the fishway, and seasonal- and diel-movement patterns were analyzed in relation to current velocity in the fishway. Also, abundances of exotic fishes such as bluegill sunfish (Lepomis macrochirus), large-mouth bass (Micropterus salmoides), and white curcian carp (Carassius cuvieri) were monitored in the fishway. Current velocity(n = 18) in the fishway showed large variations ($0.82{\pm}0.63m/s$) depending on the location of the fish trap-setting and this physical factor influenced the fish movements. Fish movements, based on the CPUE of individuals, in the fishway was greater in slower velocity (mean: 0.36 m/s, range: 0.10~1.54 m/s) than faster velocity (mean: 1.51 m/s, range: 0.90~1.90 m/s). Seasonal analysis of fish movements showed that most frequent uses (8 speices and 591 individuals, 66.2% of the total) of the fishway occurred in spring period(i.e., June). Diel movement analysis, in the mean time, showed highest in the time period of 00:00 ~ 3:00 am (7 species and 281 individuals, 20.9% of the total). The efficient managements in the fishway at Juksan Weir are required in relation to the hydrological regime.