• Title/Summary/Keyword: Mean air flow rate

Search Result 167, Processing Time 0.029 seconds

An Aerodynamic study used aerophone II for snoring patients (코콜이 환자의 sleep splint 착용 전후의 음향학적 및 공기역학적 연구)

  • Jung, Se-Jin;Kim, Hyun-Gi;Shin, Hyo-Keun
    • The Journal of the Korean dental association
    • /
    • v.49 no.4
    • /
    • pp.219-226
    • /
    • 2011
  • Snoring and obstructive sleep apnea (OSA) are common sleep disordered breathing conditions. Habitual snoring is caused by a vibration of soft tissue of upper airway while breath in sleeping, and obstructive sleep apnea is caused by the repeated obstructions of airflow for a sleeping, specially airflow of pharynx. Researchers have shown that snoring is the most important symptom connected with the obstructive sleep apnea syndrome The treatment is directed toward improving the air flow by various surgical and nonsurgical methods. The current surgical procedures used are uvulopalatopharyngoplasty(UPPP), orthognathic surgery, nasal cavity surgery. Among the nonsurgical methods there are nasal continuous positive air pressure(CPAP), pharmacologic therapy. weight loss in obese patient, oral appliance(sleep splint). Sleep splint brings the mandible forward in order to increase upper airway volume and prevents total upper airway collapse during sleep. However, the precise mechanism of action is not yet completely understood, especially aerodynamic factor. The aim of this study evaluated the effect of conservative treatment of snoring and OSAS by sleep splint through measured aerodynamic change by an aerophone II. We measured a airflow, sound pressure level, duration, mean power from overall airflow by aerophone II mask. The results indicated that on a positive correlation between a decrease in maximum airflow rate and a decrease in maximum sound pressure level, on a negative correlation between a decrease in maximum airflow rate and a increase in duration.

Performance analysis for the Characteristics of Double/ Single Effect Hybrid type Absorption Chiller (일중/이중효용 하이브리드 타입 흡수식 냉동기 성능 특성에 관한 수치적 연구)

  • You, Da-Young;Song, Tae-Min;Lee, Jung-Byoung;Kim, Hyung-Jin;Im, Ick-Tae;Moon, Sang-Done;Park, Chan-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.272-278
    • /
    • 2009
  • The characteristics of hybrid type absorption chiller are studied numerically to use a waste hot water effectively. In the case of the full load, the concentration and temperature of LiBr solution are increase about $11^{\circ}C$, 1.3% respectively at the single effect generator by hot water. As a result, the heat of the high temperature generator are decrease, so the energy can be saved. As the partial load decreased the consumption ratio of fuels are decreased and the reduction ratio of fuels are increased. The variation of COP with the inlet temperature of hot water is higher than that of the flow rate of hot water. The effect of mean temperature difference with solution and hot water of the generator are higher that of flow rate of hot water, it can effect on COP which is sensitive to heat of generator.

  • PDF

A Experimental Study on the Electronic Control Hysteresis Phenomenon of Lean Burn in Spark Ignition Engine (스파크 점화 엔진에서 희박연소의 전자제어 히스테리시스 현상에 관한 실험적 연구)

  • 김응채;김판호;서병준;김치원;이치우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.475-481
    • /
    • 2004
  • Recently it is strongly required on lower fuel consumption. lower exhaust emission, higher engine performance. and social demands in a spark ignition gasoline engine. In this study. the experimental engine used at test. it has been modified the lean burn gasoline engine. and used the programmable engine management system, and connected the controller circuit which is designed for the engine control. At the parametric study of the engine experiment, it has been controlled with fuel injection, ignition timing. swirl mode, equivalence ratio engine dynamometer load and speed as the important factors governing the engine performance adaptively. It has been found the combustion characteristics to overcome the hysteresis phenomena between normal and lean air-fuel mixing ranges. by mean of the look-up table set up the mapping values. at the optimum conditions during the engine operation. As the result, it is found that the strength of the swirl flow with the variation of engine speed and load is effective on combustion characteristics to reduce the bandwidth of the hysteresis regions. The results show that mass fraction burned and heat release rate pattern with crank angle are reduced much rather, and brake specific fuel consumption is also reduced simultaneously.

The Acoustic and Aerodynamic Aspects of Patients with Spasmodic Dysphonia (연축성 발성장애 환자의 음향학적 및 공기역학적 양상)

  • 이주환;김인섭;고윤우;오종석;배정호;윤현철;최성희;최홍식
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.11 no.1
    • /
    • pp.98-103
    • /
    • 2000
  • Background and Objectives : The etiology and pathophysiology of spasmodic dysphonia is yet unknown. This study was performed to determine if any laryngeal aerodynamic parameter distinguish the voice of patient diagnosed as having adductor spasmodic dysphonia from individuals with normal voice production and to investigate the pathophysiology of spasmodic dysphonia. Materials and Methods : fifteen women diagnosed as having adductor spasmodic dysphonia and fifteen normal control women participitated in this study Maximum phonation time, mean air flow rate, subglottic pressure, vocal efficiency, Vfo, NHR, VTI, FTRI, ATRI, Jitter percent, Shimmer percent were obtained from the participants using 'MDVP(multi-dimensional voice program)' of CSL(Computerized Speech lab, Kay Elemetrics, Co., Model No. 4300), and 'maximum sustained phonation' and 'IPIPI test' of AP II(Aerophone II, Kay Elemetrics, Co., Model 6800). Results : T-test statistical analysis revealed statistically different values for vocal efficiency, Vfo, NHR, MPT, litter percent, Shimmer percent between the spasmodic dysphonia group and the control group. Conclusions : Spasmodic dysphonia affects the ability of the laryngeal mechanism to function effectively. Results from our study demonstrate that certain aerodynamic and acoustic parameters distinguish adductor spasmodic dysphonia from normal voice.

  • PDF

The Phoniatric Evaluation of the Effect of the Laryngomicrosurgery for the Laryngeal Polyps and the Nodules (성대폴립및 결절의 치료 효과에 대한 음성의학적 고찰)

  • 김기령;홍원표;김광문;이경재;정태영;이명호
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1983.05a
    • /
    • pp.8.2-9
    • /
    • 1983
  • Recently, the laryngomicrosurgery has been done for the removal of benign laryngeal mass and for the improvement of voice. For the evaluation of the effect of the treatment, there must be any objective method such as aerodynamic study, vocal fold vibration study, acoustic analysis, psycho-acoustic evaluation and the neuro-muscular study. The authors evaluated the phoniatric effect of the laryngomicrosurgery for the patients of 15 laryngeal polyps and 9 laryngeal nodules, who received pre-op. and post-op. vocal function study from Jun. 1981 to Mar. 1983. The results obtained were as follows ; 1) The post-op. mean value of the maximum phonation time was increased 40 % in the unilateral polyps, 62 % in the bilateral nodules and 18 % in the unilateral nodules. 2) The post-op. mean value of the phonation quotient was decreased 25 % in comparison with pre-op. value in the case of the bilateral polyps, 26 % in the unilateral polyps, 55 % in the bilateral nodules and 12 % in the unilateral nodules. 3) The post-op. mean value of the mean air flow rate was decreased 27 % in comparison with the pre-op. value in the case of the bilateral polyps, 25 % in the unilateral polyps, 65 % in the bilateral nodules, 25 % in the unilateral nodules. 4) The glottic chink of the 10 cases of polyps among the 11 cases were disappeared, and the glottic chink of the 5 cases of nodules among 7 cases were also disappeared after surgery. 5) The pre-op. hoarseness of the 10 cases of polyps among the pre-op. hoarseness of the 11 cases of polyps were changed to clear and the 3 cases of nodules were also changed to clear.

  • PDF

A Study on the Effect of Recirculated Exhaust Gas with Scrubber EGR System upon Exhaust Emissions in Diesel Engines (디젤기관의 배기 배출물에 미치는 스크러버형 EGR 시스템 재순환 배기의 영향에 관한 연구)

  • Bae, Myung-Whan;Ha, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.9
    • /
    • pp.1247-1254
    • /
    • 2000
  • The effects of recirculated exhaust gas on the characteristics of $NO_x$ and soot emissions under a wide range of engine load have been experimentally investigated by a water-cooled, four-cylinder, indirect injection, four cycle and marine diesel engine operating at two kinds of engine speeds. The simultaneous control of $NO_x$ and soot emissions in diesel engines is targeted in this study. The EGR system is used to reduce $NO_x$ emissions, and a novel diesel soot removal device with a cylinder-type scrubber for the experiment system which has 6 water injectors(A water injector has 144 nozzles in 1.0 mm diameter) is specially designed and manufactured to reduce the soot contents in the recirculated exhaust gas to intake system of the engines. The intake oxygen concentration and the mean equivalence ratio calculated by the intake air flow and fuel consumption rate, and the exhaust oxygen concentration measured are used to analyse and discuss the influences of EGR rate on $NO_x$ and soot emissions. The experiments are performed at the fixed fuel injection timing of $15.3^{\circ}$ BTDC regardless of experimental conditions. It is found that $NO_x$ emissions are decreased and soot emissions are increased owing to the drop of intake oxygen concentration and exhaust oxygen concentration, and the rise of equivalence ratio as the EGR rate rises.

Experimental Studies of the Blood Gas Transport during Normothermic Hemodilution Perfusion (상온하 혈액희석 체외순환에 있어서 혈액 GAS 동태에 관한 실험적 연구)

  • 박희철
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.85-91
    • /
    • 1980
  • Extracorporeal circulation by hemodilution technique has been currently used with its clinical safety and good peripheral tissue perfusion in open heart surgery. There is no doubt that $O_{2}$ carrying capacity of the blood is disturbed by decreased hemoglobin level resulting from hemodilution of the circulating blood. From the view point of the blood gas exchange, these experimental studies were undertaken to determined the sate limit of hemodilution in the condition of cardiopulmonary bypass with a constant perfusion flow rate. Twelve adult mongrel dogs weighing 10 to 13 Kg. were anesthetized with pentobarbital and then respiration was controlled with Harvard volume respirator using room air. The cardiopulmonary by pass was performed by use of Sarns heart lung machine (console 5000, 5 head and 2 roller pumps) and Travenol pediatric bubble oxygenator. The perfusion rate during bypass was maintained at a constant rate of 80 ml/min/Kg of body weight. The ratio of oxygen gas flow to blood flow was kept in 3 to 1 constantly. International hemodilution was attained by serial blood withdrawals and immediate infusion of equal volumes of diluants composed of Ringer's lactate, 5% dextrose in water and 25% mannitol solution, proportionally 60%, 30%, and 10%. Arterial and venous blood samples were obtained between 15 and 20 minutes following each hemodilution. Hematocrits and hemoglobin values, $PO_{2}$, $PCO_{2}$ and pH were measured. Oxygen and carbon dioxide contents oxygen consumption and carbon dioxide elimination were calculated groups according to different hematocrit values and the correlations were evaluated. Result were as follows. 1. the arterial $O_{2}$ tension and $O_{2}$ saturation were maintained at the physiological level irrespective of the hematocrit value. 2. The venous $O_{2}$ tension and $O_{2}$ saturation showed a tendency to decline with the decrease in hematocrit value and positive correlation between them (r = +0.49, r = +0.76), The mean values of venous $O_{2}$ tension and $O_{2}$ saturation, however, were not decreased when the hematocrit levels were lower than 20%. 3. The arterial $O_{2}$ content declined lineally in proportion to the fall of hematocrit level with a positive correlation between them (r = +0.95). 4. The venous $O_{2}$ contents were decreased gradually as the hematocrit value decreased with positive correlation between them ( r =+0.89). The trend of diminution of venous $O_{2}$ content, however, was became low according to progressive decrease of hematocrit level. 5. Systemic oxygen consumption was in higher range than $O_{2}$ requirement of basal metabolism when the hematocrit value was above 20%, but abruptly decreased when the hematocrit value became to below 20%. 6. The arterial $CO_{2}$ tension and $CO_{2}$ content showed trend of increasing with progressive decrease of hematocrit value but exhibited a rather broad range and there was no relationship between those value and the hematocrit value. 7. The venous $CO_{2}$ tension and $CO_{2}$ content have also no correlation with change of Ht. value but related directly to those value of arterial blood with positive correlation between them (r = +0.78, r = +0.95_. 8. A-V difference of $CO_{2}$ content and $CO_{2}$ elimination wasnot significantly influenced by Ht. value. From the results, we obtained that feasible limit in inteneional hemodilution is above the hematocrit value of 20% under the given experimental condition.

  • PDF

Analysis of Phonatory Aerodynamic & Electroglottography of a Countertenor (Countertenor 1인의 Modal Register와 Falsetto Register에서의 공기역학적 변화 및 전기성문파형의 변화 연구)

  • Nam, Do-Hyun;Choi, Seong-Hee;Choi, Jae-Nam;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.17 no.1
    • /
    • pp.43-48
    • /
    • 2006
  • Background and Objectives: Countertenors who can produce higher vocal pitch like female classical singer's voice and use both modal and falsetto register. This study was conducted to study phonatory characteristics between modal and falsetto register of the countertenor. Materials and Methods: A male countertenor who had 8 years of experience was examined using a videostroboscopy and his voice was analyzed using aerodynamic measures; fundamental frequency(F0), Mean air flow rate(MFR), intensity(SLP), subglottal air pressure(Psub) with phonatory function analyzer(Nagashima) and acoustic measures; jitter, shimmer, HNR, closed quotient(CQ) using a Electro-glottography(EGG) of Lx. Speech Studio(Laryngoscope, Ltd, UK) and voice range profile of CSL(Kay elemetrics). Results: In the stroboscopy finding, the longitudinal length of vocal folds was increased at the falsetto register and the upper margin of vocal folds vibrated with incomplete closure of true vocal folds. In aerodynamic analysis, intensity was same at the modal and falsetto register. However, MFR, Psub, MPT were higher at the falsetto register. In the electroglottographic analysis, closed quotient(CQ) at the modal register was high and also much higher at the high-pitch falsetto than at the loud falsetto. In the VRP, intensity was similar though F0 was different between modal and falsetto register. Conclusion: It implied that countertenor could produce powerful voice quality by increasing of respiratory pressure and respiratory volume though glottal closure was incomplete. In addition, no change of EGG waveform, similar voice range with alto was observed.

  • PDF

A Study on Heat Transfer Characteristics of a Closed Two-Phase Thermosyphon with a Low Tilt Angle (낮은 경사각을 갖는 밀폐형 2상 열사이폰의 열전달 특성에 관한 연구)

  • 김철주;강환국;김윤철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.1-12
    • /
    • 1996
  • In lots of application to heat exchanger systems, closed two-phase thermosyphons are tilted from a horizontal. If the tilt angle, especially, is less than 30$^{\circ}$, the operational performances of thermosyphon are highly dependent on tilt angle. The present study was conducted to better understand such operational behaviors as mech-anni는 of phase change, and flow patterns inside a tilted thermosyphon. For experiment, an ethanol thermosyphon with a 35% of fill charge rate was designed and manufactured, using a copper tube with a diameter 19mm and a length 1500mm. Through a series of test, the tilt angle was kept constant at each of 4 different values in the range 10~25deg. and the heat supply to the evaporator was stepwisely increased up to 30㎾/$m^2$. When a steady state was established to the thermosyphon for each step of thermal loads, the wall temperature distribution and vapor temperature at the condenser were measured. The wall temperature distributions demonstrated a formation of dry patch in the top end zone of the evaporator, with a values of temperature 20~4$0^{\circ}C$ higher than the wetted surface for a moderate heat flux q≒20㎾/$m^2$. Inspite of the presence of hot dry patch, however, the mean values of boiling heat transfer coefficient at the evaporator wall were still in a good agreement with those predicted by Rohsenow's formula, which was based on nucleate boiling. For the condenser, the wall temperatures were practically uniform, and the measured values of condensation heat transfer coefficient were 1.7 times higher than the predicted values obtained from Nusselt's film condensation theory on tilted plate. Using those two expressions, a correlation was formulated as a function of heat flux and tilt angle, to determine the total thermal resistance of a tilted thermosyphon. The correlation formula showed a good agreement with the experimental data within 20%.

  • PDF

Effect of Humidified High Flow CO2 Gas Insufflation on the Coronary Endothelium (가습화한 고유량의 이산화탄소가스 통기가 관상동맥 내피세포층에 미치는 영향)

  • 최재성;김준성;서정욱;김기봉
    • Journal of Chest Surgery
    • /
    • v.37 no.2
    • /
    • pp.131-138
    • /
    • 2004
  • High-flow gas insufflation to get a bloodless field during off-pump coronary artery bypass may have adverse effects on the coronary endothelium. This study was designed (1) to elucidate the effect of carbon dioxide gas insufflations on the coronary endothelium at different flow rates and (2) to assess the protective effect of humidifcation against the coronary endothelial damage. Material and Method: In nine pigs, the left anterior descending coronary artery (LAD) was exposed after a median sternotomy. The LAD was divided into 4 segments and a coronary arteriotomy was made in each LAD segment in the beating heart. The far distal arteriotomy was exposed to room air for 10 minutes and was harvested as a control. Non-humidified carbon dioxide gas at a continuous flow rate of 5 L/min (Group I), humidified carbon dioxide gas at a continuous flow rate of 5 L/min (Group II), and humidified carbon dioxide gas at a continuous flow rate of 10 L/min (Group III) were insufflated for 10 minutes on each coronary arteriotomy site, respectively. After harvesting the coronary segments, hematoxylin-eosin staining, elastic fiber staining, and immunostaining with a CD34 monoclonal antibody were performed to evaluate the depth of endothelial damage and to count the residual endothelial cells, Result: In all three groups (Group I, II, and III), internal elastic laminae were preserved, however, the endothelial layers were significantly damaged by carbon dioxide gas insufflation. The mean percentages of remaining endothelial cells were 20,9$\pm$16.7%, 39.3$\pm$19.6%, and 6.8$\pm$5.3%, in groups I, II, and III, respectively. The percentages of remaining cells were significantly higher in group II than in groups I and III (p=0.008). The percentages of remaining cells were significantly higher in group I than in group III (p=0.008). Conclusions: The harmful effect of carbon dioxide gas insufflation on the coronary endothelium was dependent on the flow rate. The addition of humidification did not protect the coronary endothelium from denudation injury caused by high flow carbon dioxide gas insufflations.