• Title/Summary/Keyword: Mean Reduction Method

Search Result 553, Processing Time 0.042 seconds

Stereo-video Synchronization for 3D Video Transmission (3차원 비디오 전송을 위한 스테레오비디오 동기화 방법)

  • Lee, Dong-Jin;Lee, Seon-Oh;Sim, Dong-Gyu;Lee, Hyuk-Joon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.4B
    • /
    • pp.349-359
    • /
    • 2009
  • In this paper, we propose a stereo-video transmission method for reduction of delay and maximization of 3D effect. Conventional multimedia synchronization algorithms were designed to achieve minimum delay and synchronize multiple video and audio streams, however, they could not be effective for 3D video transmission. In this paper, we proposed a synchronization algorithm by considering the minimum error of time difference between streams for 3D effect. The minimum error of time difference for 3D effect was derived based on a 3D subjective quality test. We compute display time of the delivered videos within the allowed time-difference and the video are displayed according to the display time. To evaluate the performance of the proposed algorithm, we implemented a real-time video communication system and subjective quality test has been conducted with the proposed system. We found that video quality displayed by the proposed system. We found that video quality displayed by the proposed algorithm ranks 'good' and 'excellent' in the DMOS (Differential Mean Opinion Score) scale, based on the MOS (Mean Opinion Score) test.

Preparation of Silica Microgels Using Membrane Emulsification Method (막유화법을 이용한 실리카 마이크로겔의 제조)

  • Youm, Kyung-Ho;Kwak, No-Shin
    • Membrane Journal
    • /
    • v.19 no.2
    • /
    • pp.122-128
    • /
    • 2009
  • We prepared monodispersed spherical silica microgels by controlling various conditions of emulsification procedure using a lab-scale membrane emulsification system equipped with SPG (Shirasu porous glass) porous membrane having pore size of $1.5{\mu}m$. We determined the effects of process parameters of membrane emulsification (ratio of dispersed phase to continuous phase, sodium silicate concentration, emulsifier concentration, dispersed phase pressure, stirring speed) on the mean size and size distribution of silica microgels. The increase of the ratio of dispersed phase to continuous phase, dispersed phase pressure and sodium silicate concentration led to the increase in the mean size of microgels. On the contrary, the increase in emulsifier concentration and stirring speed of the continuous phase caused the reduction of the mean size of microgels. Through controlling these parameters, monodisperse spherical silica microgels with about $6{\mu}m$ of the mean size were finally prepared.

THE MANAGEMENT OF PATIENTS WITH SEVERE APLASTIC ANEMIA IN ORAL & MAXILLOFACIAL SURGERY (중증 재생불량성 빈혈환자의 구강악안면외과적 관리)

  • Yoon, Hyun-Joong;Park, Je-Uk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.5
    • /
    • pp.464-467
    • /
    • 2001
  • Aplastic anemia is a hematopoietic disorder characterized by marked reduction or absence of erythoid, granulocytic, and megakariocytic cells in the bone marrow with resultant pancytopenia. To control of infection & bleeding secondary to leukopenia and thrombocytopenia, the inflammatory lesions in oral & maxillofacial area should be removed. Material & Method: The extractions were performed on 21 patients with severe aplastic anemia. The initial, pre-operative and postoperative CBCs were checked up. Amount and kind of transfused platelet in each patient and increment of platelet level were recorded. The complications were documented. Result : A mean of 2.9 teeth were extracted from each patient(ranging between 1 and 13). Furthermore, surgical extractions including ostectomy and odontectomy of the third molar were performed on 11 patients. The preoperative WBC levels presented between $600/{\mu}L$ and $5000/{\mu}L$(mean $2376/{\mu}L$). The WBC values decreased by an average of $145/{\mu}L$ per patient after extractions had been performed. The teeth of 16 patients were extracted under 10.0g/dL, and the mean change in postoperative hemoglobin levels in comparison with preoperative hemoglobin levels was -0.06 per patient. The initial platelet levels were between 1000/(L and $81,000/{\mu}L$(mean $20,174/{\mu}L$). In five patients, extractions were performed with platelet levels less than $50,000/{\mu}L$. Conclusion : The results suggest that more active and preventive treatments in the oral and maxillofacial area are possible and are necessary to remove the infectious foci on the patients with severe aplastic anemia. We report the results of our experiences and literature reviews in treatment of the patients with severe aplastic anemia in our department.

  • PDF

Simulation of Active Noise Control on Harmonic Sound (복수조화음에 대한 능동소음제어 시뮬레이션)

  • Kwon, O-Cheol;Lee, Gyeong-Tae;Lee, Hae-Jin;Yang, In-Hyung;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.737-742
    • /
    • 2007
  • The method of the reducing duct noise can be classified by passive and active control techniques. However, passive control has a limited effect of noise reduction at low frequencies (below 500Hz) and is limited by the space. On the other hand, active control can overcome these passive control limitations. The active control technique mostly uses the Least-Mean-Square (LMS) algorithm, because the LMS algorithm can easily obtain the complex transfer function in real-time particularly when the Filtered-X LMS (FXLMS) algorithm is applied to an active noise control (ANC) system. However, the convergence performance of the LMS algorithm decreases slightly so it may delay the convergence time when the FXLMS algorithm is applied to the active control of duct noise. Thus the Co-FXLMS algorithm was developed to improve the control performance in order to solve this problem. The Co-FXLMS algorithm is realized by using an estimate of the cross correlation between the adaptation error and the filtered input signal to control the step size. In this paper, the performance of the Co-FXLMS algorithm is presented in comparison with the FXLMS algorithm. Simulation results show that active noise control using Co-FXLMS is effective in reducing duct noise.

  • PDF

Finite element analysis of the fluid-structure interaction in a compliant vessel (유연 혈관에서 유체-고체 상호작용에 대한 유한요소 해석)

  • Shim, Eun-Bo;Ko, Hyung-Jong;Kamm, Roger D.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.591-596
    • /
    • 2000
  • Flow through compliant tubes with linear taper in wall thickness is numerically simulated by finite element analysis. Two models are examined: a planar two-dimensional channel, and an axisymmetric tube. For verification of the numerical method, flow through a compliant stenotic vessel is simulated and compared to existing experimental data. Computational results for an axisymmetric tube show that as cross-sectional area falls with a reduction in downstream pressure, flow rate increases and reaches a maximum when the speed index (mean velocity divided by wave speed) is near unity at the point of minimum cross-section area, indicative of wave speed flow limitation or "choking" (flow speed equals wave speed) in previous one-dimensional studies. For further reductions in downstream pressure, flow rate decreases. Cross-sectional narrowing is significant but localized. When the ratio of downstream-to-upstream wall thickness is ${\le}$ 2 the area throat is located near the downstream end; as wall taper is increased to ${\ge}$ 3 the constriction moves to the upstream end of the tube. In the planar two-dimensional channel, area reduction and flow limitation are also observed when outlet pressure is decreased. In contrast to the axisymmetric case, however, the elastic wall in the two-dimensional channel forms a smooth concave surface with the area throat located near the mid-point of the elastic wall. Though flow rate reaches a maximum and then falls, the flow does not appear to be choked.

  • PDF

Minimizing MR Gradient Artefacts on ECG Signals for Cardiac Gating based on an Adaptive Digital Filter (적응 디지털 필터 기반의 MRI Cardiac Gating을 위한 심전도 신호의 MR Gradient 잡음 최소화 방법)

  • Park, Ho-Dong;Jang, Bong-Ryeol;Lee, Kyoung-Joung
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.817-818
    • /
    • 2006
  • In Magnetic Resonance Imaging(MRI), the QRS complex of ECG is used as a trigger signal for MRI scan. But, gradient and RF(radio frequency) artifacts which are caused to static and dynamic field in MRI scanner cause interference in the ECG. Also, the signal shape of theses artifacts can be similar to the QRS-complex, causing possible misinterpretation during patient monitoring and false gating of the MRI. In case of using general FIR or IIR band-pass filters for minimizing the artifacts, artifact-reduction-ratio is not excellent. So, an adaptive real-time digital filter is proposed for reduction of noise by gradient and RF(radio frequency) artifacts. The proposed filter for MRI-Gating is based on the noise-canceller with NLMS(Normalized Least Mean Square) algorithm. The reference signals of the adaptive noise canceller are a combination of the noisy three channel ECG signals. In conclusions, the proposed method showed the acceptable quality of ECG signal with sufficient SNR for gating the MRI and possibility of real time implementation.

  • PDF

Codesign of IS-95 based CDMA Searcher (IS-95 기반 CDMA Searcher의 통합설계)

  • 황인기
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.9A
    • /
    • pp.1368-1376
    • /
    • 2000
  • This paper describes the codesign method for IS-95 based CDMA(Code Division Multiple Access). By codesign we mean to design hardware and software simultaneously. Codesign lead to reduction in design time, cost and power consumption. When we partition a system into hardware and software, some modules with longer processing time and larger power consumption are implemented using hardware and the remaining part is implemented using software. In proposed design, we design the synchronous accumulator of CDMA searcher in hardware and the other part in software, The hardware part is designed using VHDL, while software part is designed using GC(Generic C). We simulated and verified the system using COSSAP in SYNOPSYSTM. Experimentation showed the maximum 48.5% speed reduction compared with the design using software only.

  • PDF

Location Error Reduction method using Iterative Calculation in UWB system (Iterative Calculation을 이용한 UWB 위치측정에서의 오차감소 기법)

  • Jang, Sung-Jeen;Hwang, Jae-Ho;Choi, Nack-Hyun;Kim, Jae-Moung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.12
    • /
    • pp.105-113
    • /
    • 2008
  • In Ubiquitous Society, accurate Location Calculation of user's device is required to achieve the need of users. As the location calculation is processed by ranging between transceivers, if some obstacles exist between transceivers, NLoS(Non-line-of-Sight) components of received signal increase along with the reduction of LoS(Line-of-Sight) components. Therefore the location calculation error will increase due to the NLoS effect. The conventional location calculation algorithm has the original ranging error because there is no transformation of ranging information which degrades the ranging accuracy. The Iterative Calculation method which minimizes the location calculation error relys on accurately identifying NLoS or LoS condition of the tested channel. We employ Kurtosis, Mean Excess Delay and RMS Delay spread of the received signal to identify whether the tested channel is LoS or NLoS firstly. Thereafter, to minimize location calculation error, the proposed Iterative Calculation method iteratively select random range and finds the averaged target location which has high probability. The simulation results confirm the enhancement of the proposed method.

Effect of Heat Treatment on the Gas Permeability, Sound Absorption Coefficient, and Sound Transmission Loss of Paulownia tomentosa Wood (참오동나무의 열처리가 기체투과성, 흡음율과 음향투과손실에 미치는 영향)

  • KANG, Chun-Won;JANG, Eun-Suk;JANG, Sang-Sik;Cho, Jae-Ik;KIM, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.5
    • /
    • pp.644-654
    • /
    • 2019
  • In this study, the gas permeability, sound absorption coefficient, and sound transmission loss of the Paulownia tomentosa wood were estimated using capillary flow porometry, transfer function method, and transfer matrix method, respectively. The longitudinal specific permeability constant of the Paulownia tomentosa wood with a thickness of 20 mm was 0.254 for the control sample and 0.279, 0.314, and 0.452 after being subjected to heat treatments at $100^{\circ}C$, $160^{\circ}C$, and $200^{\circ}C$, respectively. The gas permeability was observed to be slightly increased by the heat treatment. The mean sound absorption coefficients of 20-mm thick Paulownia tomentosa log cross-section for the control sample and after being subjected to heat treatments at $100^{\circ}C$, $160^{\circ}C$, and $200^{\circ}C$ were 0.101, 0.109, 0.096 and 0.106, respectively. Further, the noise reduction coefficients of 20-mm thick Paulownia tomentosa log cross-section of the control sample and after being subjected to heat treatment at temperatures of $100^{\circ}C$, $160^{\circ}C$, and $200^{\circ}C$ were 0.060, 0.067, 0.062 and 0.071, respectively. The mean of sound transmission loss of the 20-mm thick Paulownia tomentosa log cross-section was approximately 36.93 dB. Furthermore, the gas permeability and sound absorption coefficient of the heat-treated Paulownia tomentosa discs slightly increased depending on the heat treatment temperature; however, the rate of increase was insignificant.

The Effects of Wall Elasticity on Wall Shear Rate of a Divergent Tube (Vascular Graft) (벽 탄성도가 확장관(인조혈관) 벽 전단변형률에 미치는 영향)

  • Rhee, Kye-Han;Lee, Sang-Man
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.6 s.165
    • /
    • pp.912-921
    • /
    • 1999
  • Shear stress acting on the arterial wall by blood flow is an important hemodynamic factor influencing blocking of blood vessel by thickening of an arterial wall. In order to study the effects of wall elasticity on the wall shear rate distribution in an artery-divergent graft anastomosis, a rigid and a elastic model are manufactured. These models are placed in a pulsatile flow loop, which can generate the desired flow waveform. Flow visualization method using a photochromic dye is used to measure the wall shear rate distribution. The accuracy of measuring technique is verified by comparing the measured wall shear rate in the straight portion of a model with the theoretical solution. Measured wall shear rates depend on the wall elasticity and flow waveform. The mean and maximum shear rate in the elastic model are lower than those in rigid model, and the decreases are more significant near the end of a divergent tube. The reduction of mean and maximum of wall shear rate in an elastic model are up to 17 percent.