• Title/Summary/Keyword: Mean Flow Velocity

Search Result 1,030, Processing Time 0.029 seconds

Turbulent Flow Field Structure of Initially Asymmetric Jets

  • Kim, Kyung-Hoon;Kim, Bong-Whan;Kim, Suk-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.12
    • /
    • pp.1386-1395
    • /
    • 2000
  • The mear field structure of round turbulent jets with initially asymmetric velocity distributions is investigated experimentally. Experiments are carried out using a constant temperature hot-wire anemometry system to measure streamwise velocity in the jets. The measurements are undertaken across the jet at various streamwise stations in a range starting from the jet exit plane and up to a downstream location of twelve diameters. The experimental results include the distributions of mean and instantaneous velocities, vorticity field, turbulence intensity, and the Reynolds shear stresses. The asymmetry of the jet exit plane was obtained by using circular cross-section pipes with a bend upstream of the exit. There pipes used here include a straight pipe, and 90 and 160 degree-bend pipes. Therefore, at the upstream of the upstream of the pipe exit, secondary flow through the bend mean streamwise velocity distribution could be controlled by changing the curvature of pipes. The jets into the atmosphere have two levels of initial velocity skewness in addition to an axisymmetric jet from a straight pipe. In case of the curved pipe, a six diameter-long straight pipe section follows the bend upstream of the exit. The Reynolds number based on the exit bulk velocity is 13,400. The results indicate that the near field structure is considerably modified by the skewness of an initial mean velocity distribution. As the skewness increases, the decay rate of mean velocity at the centerline also increases.

  • PDF

Effect of Paekoe(GV20) Acupuncture on Cerebral Blood Flow (백회혈 자침이 뇌혈류에 미치는 영향)

  • Lee Hong-Min;Cheong Byung-Shik;Yun Hyoung-Seok;Cho Seong-Gyu;Lee Sang-Hoon;Jun Hyung-Joon;Nam Sang-Soo;Kim Yong-Suk;Lee Joo-Hyung
    • Journal of Acupuncture Research
    • /
    • v.18 no.6
    • /
    • pp.105-113
    • /
    • 2001
  • Objective : This study was performed to evaluate the effect of acupuncture on cerebral blood flow by Transcranial Doppler Ultrasonography(TCD) Method : Monitoring of TCD was examined in 11 healthy women volunteer(mean $age:\;24.5{\pm}2.9\;\;years$) before, during and after acupuncture on Paekoe(GV20). Mean velocity, pulsatility index, systolic velocity and diastolic velocity values are analyzed from DWL. MDX4 at different depths of both middle cerebral artery. Results : The results showed a significant(p<0.05; Friedman test & Wilcoxon signed ranks test) increase in mean velocity, systolic velocity and diastolic velocity decrease in pulsatility index, which was measured at different depths of both middle cerebral artery. Conclusion : These results suggest that acupuncture could have a specific effect on cerebral blood flow.

  • PDF

Study on Cerebral Blood Flow in In-Young(ST9) after Treatment on Chronic Daily Headache Patients (만성두통 환자에서 한방 치료 후 인영혈 부위의 뇌혈류에 대한 연구)

  • Lee, Chung-Sik;Park, Bo-Ra;Park, In-Suk;Kim, Ji-Hwon;Lee, Sang-Eon;Lim, Jin-Young;Lyu, Yeoung-Su;Kang, Hyung-Won;Kim, Tae-Heon
    • Journal of Oriental Neuropsychiatry
    • /
    • v.20 no.1
    • /
    • pp.199-214
    • /
    • 2009
  • Objectives : This study was performed to change of blood flow in In-Young(ST9) after treatment on chronic daily headache patients. Methods : Monitoring of TCD was examined in 10' s chronic daily headache patients before and after treatment. Mean velocity flow, systolic velocity and pulsatility index were analyzed from TCD at In-Young(ST9). The patients was laid for 20 minutes before treatment and also for treatment. Results : The results showed a significant(p<0.05: Paired T-test) decrease in mean velocity flow and systolic velocity. but there were no significant differences in pulsatility index. Conclusions : These results suggest that there were significant change on blood flow in In-young of chronic daily headache patients.

  • PDF

Calibration of Water Velocity Profile in Circular Water Channel Using Particle Image Velocimetry (PIV를 이용한 회류수조의 유속 분포 교정에 관한 연구)

  • Suh, Sung-Bu;Jung, Kwang-Hyo
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.23-27
    • /
    • 2011
  • This experimental study was performed to find rpms of the impeller and the surface flow accelerator to make a uniform velocity vertical distribution in the circular water channel. PIV technique was employed to measure the water velocity profiles into the water depth from the free surface. The number of instantaneous velocity profiles was decomposed into mean and turbulence velocity components, and the distribution of velocity fluctuation and turbulence intensity were computed for each experimental condition. From these results, the velocity uniformity was quantitatively determined to present the flow quality in the measuring section of the circular water channel. It has been shown that the proper operation of the surface flow accelerator would make the uniform velocity profiles and reduce the velocity fluctuation near the free surface.

An Experimental Study on Turbulent Flow in 90 Degree Bend by using PIV Techiqure (PIV기법을 이용한 $90^{\circ}$ 곡관에서 난류유동에 관한 실험적 연구)

  • 장태현;이해수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.648-656
    • /
    • 2003
  • An experimental research was performed to study turbulent flow characteristic in a $90^{\circ}$ circular bend by using the PIV(Particle Image Velocimetry) method, this study found the time-mean velocity distribution, time-mean turbulent intensity with turbulent flow for Re = 10,000, 15,000, 20,000, and 25,000 along the test bend. It was found that the highest streamwise velocity of turbulent flow occurs near y/D = 0.5 and the flow moved to y/D =0.15. The peak turbulence intensity shifted toward the concave wall from $\theta= 45 and as \theta$ increased. the intensity decayed along the test tube.

A Real-Time Measurement of Slug Flow Using Electromagnetic Flowmeter with High frequency Triangular Excitation (고주파 삼각파 여자법을 사용한 실시간 슬러그 유동 측정용 전자기유량계)

  • Ahn, Yeh-Chan;Cha, Jae-Eun;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1570-1577
    • /
    • 2002
  • In order to investigate the characteristics of two-phase slug flow, an electromagnetic flowmeter with 240Hz triangular AC excitation was designed and manufactured. The signals and noise from the flowmeter were obtained, and analyzed in comparison with the observations with a high speed CCD camera. The uncertainty of the flowmeter under single-phase flow was $\pm$ 2.24% in real-time. For two-phase slug flow, electromagnetic flowmeter provided real-time simultaneous measurements of the mean film velocity around Taylor bubble and the relative location and the length of the bubble. Besides, it is an easier and cheaper method for measuring mean film velocity than others such as photochromic dye activation method or particle image velocimetry.

The Droplet Size Distribution of Fan Spray at Different Surrounding Conditions (팬형분무의 주변조건에 따른 입자분포 변화)

  • Moon, Seok-Su;Choi, Jae-Joon;Bae, Choong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.7 s.262
    • /
    • pp.611-619
    • /
    • 2007
  • In this study, the droplet size distribution of a slit injector at different surrounding conditions, such as air flow and fuel temperature, were investigated. Phase Doppler anemometry (PDA) was utilized to investigate the initial droplet size distribution and the effect of fuel temperature and air flow on droplet size distribution. The entrained air motion was also evaluated by the temporal velocity profile of droplets. When the air flow velocity increased, the small droplets were more entrained to the upper and central parts of the spray and this tendency was confirmed by plotting the temporal velocity profile of droplets. This entrainment of small droplets at high airflow velocities caused relatively small mean droplet size at upper and central parts of the spray and the large mean droplet size at downstream and edge of the spray, compared to that of low airflow velocities. The total mean droplet size, obtained by averaging the size of all droplets measured at all test locations, decreased when the high airflow velocities were applied. The increased fuel temperature, with an airflow velocity of 10m/s, caused reduced droplet size at all test locations. However, the decreased value of mean droplet size at high fuel temperatures was relatively higher at upper parts of the spray, compared to downstream, as a result of enhanced entrainment of small droplets to upper parts of the spray.

The estimation of river discharge by using the mean velocity equation in a unsteady condition (평균유속공식을 이용한 부정류 하천유량 산정)

  • Choo, Tai Ho;Chae, Soo Kwon;Yoon, Hyeon Cheol;Yun, Gwan Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6558-6564
    • /
    • 2013
  • As the average indicator for amount of water flowing in any cross section of a river, the mean discharge has been reported to be a very important factor for examining water circle constructions in a river basin, the design and construction of a hydraulic structure, and water front area use and management. The stage-discharge curve based on discharge and stage data measured in a normal season were basically derived. Using this derivation, the necessary discharge data was obtained. The values produced in this manner corresponded to the measured data in a uniform flow state well, but showed limited accuracy in a flood season (unsteady flow). In the present paper, the mean velocity in unsteady flow conditions, which exhibited loop form properties, was estimated using the new mean velocity formula derived from Chiu's 2-D velocity. The results of RMSE and Polar graph analyses showed that the proposed equation exhibited approximately nineteen times the accuracy compared to the Manning and Chezy equations.

A Study on the Near Wake of a Square Cylinder Using Particle Image Velocimetry ( I )- Mean Flow Field - (PIV기법을 이용한 정사각 실린더의 근접후류에 관한 연구 (I) - 평균유동장 -)

  • Lee, Man-Bok;Kim, Gyeong-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1408-1416
    • /
    • 2001
  • Mean flow fields in the near wake of a square cylinder have been studied experimentally using a Particle Image Velocimetry (PIV). Ensemble-averaged velocity fields are successfully measured fur the square cylinder wake including the reverse flow region which arises many difficulties in accurate measurement by using conventional techniques, Experiments are performed at two free stream velocities of U$\_$$\infty$/ = 1.27m/s and 3.03m/s. The corresponding Reynolds numbers based on the free-stream velocity and cylinder diameter are 1600 and 3900, respectively. The intensity of free-stream turbulence is less than 1%, the blockage ratio (D/H) is 6.6% and the aspect ratio (W/D) is 40. The effect of Reynolds number on the near wake of a square cylinder has been investigated by the global mean velocity and instantaneous velocity fields. The most striking feature is that the length of the recirculating region increases with increasing Reynolds number, which turns out totally reverse trend compared with those observed in the circular cylinder wake at the same range of Reynolds number. Fer the case of higher Reynolds number, the mean velocity data agree well with those of relevant existing data obtained at much higher Reynolds numbers, which reflects the general aspect of sharp-edged bluff body wake.

The Transcranial Doppler(TCD) Assesment of Vertebrobasal Vascular Blood Flow in Cerebral Infarction (Transcranial Doppler를 이용(利用)한 급성기뇌경색(急性期腦硬塞)이 추골기저동맥계(椎骨基底動脈係) 혈관(血管)의 혈류속도(血流速度)에 미치는 영향(影響))

  • Ahn, Teck-Won;Kim, Yoon-Sik
    • The Journal of Internal Korean Medicine
    • /
    • v.21 no.5
    • /
    • pp.805-811
    • /
    • 2000
  • Objectives : To determine the effects on blood flow of vertebrobasal vascular system in cerebral infarction, Methods : We altered 33 normal patients and 12 patients who were diagnosed cerebral infarction on Rt. middle cerebral artery(MCA) region and 8 patients who were diagnosed cerebral infarction on Lt, MCA region, and measured the mean velocity, systolic to diastolic rate(SD rate), asymmetrical index(A/I) by TCD. Results : The mean velocity of posterior cerebral artery(PCA), vertebral artery was increased in same direction as infarcted site and the mean velocity of basal artery was more increased than control, and the SD rate of PCA, vertebral artery, basal artery was larger than control. The A/l of PCA, vertebral artery was revealed that mean velocity of vertebrobasal vascular system is increase the same direction as infarcted area. Conclusion : TCD examination within 7 days(acute stage) after stroke can help to predict the infarcted direction.

  • PDF