• 제목/요약/키워드: Mean Flow Coefficient

검색결과 344건 처리시간 0.027초

THEORETICAL AND EXPERIMENTAL INVESTIGATIONS OF VELOCITY DISTRIBUTIONS FOR ROUND JETS

  • Seo, Il-Won;Mohamed S. Gadalrab;Lyu, Si-wan;Park, Yong-sung
    • Water Engineering Research
    • /
    • 제2권2호
    • /
    • pp.89-101
    • /
    • 2001
  • The theoretical treatments on jets, in which the flow is issuing into a stagnant medium, have been based on Prandtl's mixing theory. In this study, using Prandtl's mixing length hypothesis, a theoretical relationship for the velocity profile of a single round jet is derived. Furthermore, Gaussian expression is used to approximate the theoretical relationship, in which the Gaussian coefficient is assumed to be decreasing exponentially as the flow goes far from the orifice. Two data sets for a single round jet performed by tow different techniques of measurement are used to verify the suggested relationships. The theoretical and Gaussian distribution give close results in spite of the difference in approach. The observed mean velocity distributions are in good agreements with the suggested theoretical and Gaussian distributions.

  • PDF

Pilot 규모의 모의 관망에서의 염소 농도 예측 (Prediction of Chlorine Concentration in a Pilot-Scaled Plant Distribution System)

  • 김현준;김상현
    • 상하수도학회지
    • /
    • 제26권6호
    • /
    • pp.861-869
    • /
    • 2012
  • The chlorine's residual concentration prevents the regrowth of microorganism in water transport along the pipeline system. Precise prediction of chlorine concentration is important in determining disinfectant injection for the water distribution system. In this study, a pilot scale water distribution system was designed and fabricated to measure the temporal variation of chlorine concentration for three flow conditions (V = 0.88, 1.33, 1.95 m/s). Various kinetic models were applied to identify the relationship between hydraulic condition and chlorine decay. Genetic Algorithm (GA) was integrated into five kinetic models and time series of chlorine were used to calibrate parameters. Model fitness was compared by Root Mean Square Error (RMSE) between measurement and prediction. Limited first order model and Parallel first order showed good fitness for prediction of chlorine concentration.

입구유동 가진이 있는 충돌제트 유동의 유동 및 열전달 변화에 대한 난류모델 적용 (Application of turbulent model to characteristics of heat transfer in impinging jet flow with pulsed inlet)

  • 권동호;김희영;박태선
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.593-596
    • /
    • 2008
  • Because of good performance of heat transfer characteristics, impinging jets are widely used in many industries for cooling or heating. And the present num erical studies attempt to show the effects of impinging jet. This paper considers the application of the turbulent models to impinging jet flow with pulsed inlet. It is assumed two-dimensional turbulent flows. The jet Reynolds num ber is set at 23,000 and the distance from the exit of the nozzle to the plate is 3 times larger than the diam eter of the nozzle. The influence of the Strouhal num ber(pulsation frequency) on Nusselt number at the impinging region is investigated. Strouhal numbers are ranged 0.0 to 0.5 and the forcing amplitudes are 1%,5%,9% of mean inlet velocity. In this study, the Nusselt number at the impinging region is sensitive to the pulsation frequency. Heat transfer coefficient strongly increase at Strouhal num ber of 0.4.

  • PDF

배수갑문 운영을 고려한 간척 하구호의 해수순환모의 (Simulation of circulation in Estuarine Lake caused by Operation of Drainage gates)

  • 박영진;엄명철;권순국
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.313-317
    • /
    • 2005
  • This study aimed to estimate applicability of a model to simulate circulation in estuarine lake caused by operation of drainage gates. The model consists of 2D (depth-averaged) hydrodynamic models, Delft3D-FLOW model and operation model for drainage gates. The flow through drainage gates was calculated using weir formulae with discharge coefficient, 0.8. The simulations are performed under two conditions: uncontrolled condition and controlled by periods of two days. The results on simulation of the model showed that the water level in estuarine lake was tend to increase above mean sea level. Therefore it was proved that the calibration and verification were needed in order to applicate this model for Saemankeum area.

  • PDF

천음속 원심압축기의 공력설계 및 수치해석 (Aerodynamic Design and Numerical Analysis on a Transonic Centrifugal Compressor)

  • 최재호
    • 한국추진공학회지
    • /
    • 제12권4호
    • /
    • pp.56-62
    • /
    • 2008
  • 가스터빈에 적용되는 천음속 원심압축기에 대한 공력설계 및 수치해석을 수행하였다. 평균유선법과 준삼차원 해석을 기반으로 공력설계를 수행하고, 레이놀즈 평균 나비어-스톡스 해석을 통해 압축기 내부 유동장을 해석하였다. 천음속 압축기에서 정압계수, 스월 파라미터 및 블레이드 공력하중 등 주요 공력파라미터들에 대한 분석과 임펠러와 디퓨저 내부 유동장에 대한 고찰이 이루어졌다.

암모니아의 수평관내 단상 및 응축 열전달계수의 측정 (Measurement of Single Phase and Condensation Heat Transfer Coefficients of Ammonia in a Horizontal Tube)

  • 백영진;장영수;김영일
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.561-569
    • /
    • 2000
  • Single phase and condensation heat transfer characteristics of ammonia in a horizontal tube have been investigated experimentally The horizontal test section is composed of smooth SUS316 tube for refrigerant flow, surrounding annulus for water flow, and temperature and Pressure measuring sensors. For single phase test, subcooled ammonia mass flux was varied from 320 to 501 kg/mrs and temperature was varied from 18 to $47^{\circ}C$. For condensation test, mass flux and saturation temperature were varied from 86 to 128 kg/$m^2$s and 34 to $47^{\circ}C$, respectively. The equations of Gnielinski Soliman et al., Traviss et at., Cavallini and Zecchin, Shah, Chen et al., Tandon et al., and Chilli and Anand were compared with the experimental data. New correlations are proposed based on the experimental results and the absolute mean deviation of the experimental data becomes 1.0% for single phase test and 4.9% for condensation test.

  • PDF

회전하는 터빈 블레이드에서의 열전달 특성 (Detailed Heat Transfer Characteristics on Rotating Turbine Blade)

  • 이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제30권11호
    • /
    • pp.1074-1083
    • /
    • 2006
  • In the present study, the effect of blade rotation on blade heat transfer is investigated by comparing with the heat transfer results for the stationary blade. The experiments are conducted in a low speed annular cascade with a single stage turbine and the turbine stage is composed of sixteen guide vanes and blades. The chord length and the height of the tested blade are 150 mm and about 125 mm, respectively. The blade has a flat tip and the mean tip clearance is 2.5% of the blade chord. A naphthalene sublimation method is used to measure detailed mass transfer coefficient on the blade. For the experiments, the inlet Reynolds number is $Re_c=1.5{\times}10^5$, which results in the blade rotation speed of 255.8 rpm. Blade rotation induces a relative motion between the blade and the shroud as well as a periodic variation of incoming flow. Therefore, different heat/mass transfer patterns are observed on the rotating blade, especially near the tip and on the tip. The relative motion reduces the tip leakage flow through the tip gap, which results in the reduction of the tip heat transfer. However, the effect of the tip leakage flow on the blade surface is increased because the tip leakage vortex is formed closer to the surface than the stationary case. The overall heat/mass transfer on the shroud is not affected much by the blade rotation.

입사각 변화에 따른 터빈 블레이드에서의 열전달 특성 변화 (I) - 블레이드 끝단면 - (Effect of Incidence Angle on Turbine Blade Heat Transfer Characteristics (I) - Blade Tip -)

  • 이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제31권4호
    • /
    • pp.349-356
    • /
    • 2007
  • The present study investigated local heat/mass transfer characteristics on the tip of the rotating turbine blade with various incoming flow incidence angles. The experiments are conducted in a low speed annular cascade with a single stage turbine. The blade has a flat tip with a mean tip clearance of 2.5% of the blade chord. The incoming flow Reynolds number is $1.5{\times}10^5$ at design condition. To examine the effect of off-design condition, the experiments with various incidence angles ranging between $-15^{\circ}$ and $+7{\circ}$ were conducted. A naphthalene sublimation method is used to measure detailed mass transfer coefficient on the blade. The results indicated that the incidence angle strongly affects the behavior of tip leakage flow around the blade tip and consequently plays an important role in determining heat transfer characteristics on the tip. For negative incidence angles, the heat/mass transfer in the upstream region on the tip decreases by up to 20%. On the contrary, for positive incidence angles, much higher heat transfer coefficients are observed even with small increase of incidence angle.

지표유속법 기반 제주 산지형 하천 Kalesto 유량 정확도 향상 기법 (Enhancement Technique of Discharge Measurement Accuracy Using Kalesto Based on Index Velocity Method in Mountain Stream, Jeju Island)

  • 김동수;양성기;김수정;이준호
    • 한국환경과학회지
    • /
    • 제24권4호
    • /
    • pp.371-381
    • /
    • 2015
  • In the mountain streams in Jeju Island, strong turbulence and roughness usually made it nearly impossible to utilize most of intrusive instrumentation for streamflow discharge measurements. Instead, a non-intrusive fixed electro-magnetic wave surface velocimetry (fixed EWSV: Kalesto) became alternatively popular in many representative streams to measure stream discharge seamlessly. Currently, Kalesto has shown noteworthy performance with little loss in flood discharge measurements and also has successfully provided discharge for every minute. However, Kalesto has been operated to regard its measured one-point velocity as the representative mean velocity for the given cross-section. Therefore, it could be highly possible to potentially encompass discharge measurements errors. In this study, we analyzed the difference between such Kalesto discharge measurements and other alternative concurrent discharge measurements such as Acoustic Doppler Current Profiler (ADCP) and mobile EWSV which were able to measure velocity in multi-points in the cross-section. Consequently, Kalesto discharge deviated from ADCP discharge in amount of 48% for relatively low flow, and more than 20% difference for high flow compared with mobile EWSV discharge measurements. These results indicated that the one-point velocity measured by Kalesto should be used as a cross-sectional mean velocity, rather it should be accounted for as an index-velocity in conjunction with directly measured cross-sectional mean velocity by using more reliable instrumentations. After inducing Kalesto Discharge Correction Coefficient (KDCC) that actually means relationship between index velocity and cross-sectional mean velocity, the corrected discharge from Kalesto was significantly improved. Therefore, we found that index velocity method should be applied to obtain better accuracy of discharge measurement in case of Kalesto operation.

금강 유역의 댐과 물이용에 의한 유황의 변동특성 분석 (Effects of Dams and Water Use on Flow Regime Alteration of the Geum River Basin)

  • 강성규;이동률;문장원;최시중
    • 한국수자원학회논문집
    • /
    • 제43권4호
    • /
    • pp.325-336
    • /
    • 2010
  • 본 연구에서는 금강유역의 물이용과 댐의 영향에 의한 하천유황의 변화를 평가하였다. 유황변화의 압력지표로서 하천수 이용률과 담수지수를 분석하였다. 유황의 정량적인 변화 분석을 위하여 유황곡선, 유황계수, 홍수 및 갈수 빈도분석과 유량변동분석법을 적용하였다. 8개 분석 대상지점의 결과는 댐 건설전의 유황과 비교할 때 댐과 물이용의 영향으로 고유량 범위에서는 감소하고, 저유량 범위에서는 증가하고 있음을 구체적인 수치로 확인하였다. 금강유역은 연평균유출량의 24%를 저류할 수 있는 139개의 댐과 저수지에 의해 유황이 조절되고 지표수의 이용률이 36%로서 이들의 지표가 유황변화의 압력요인이 되고 있다.