• Title/Summary/Keyword: Mean Flow Analysis

Search Result 869, Processing Time 0.028 seconds

An experimental study of a flow field generated by a rotating cylinder on a plane moving at free stream velocity (자유흐름 속도의 이동면과 맞닿은 회전실린더 주위 유동장의 실험적 해석)

  • Park, Un-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.700-712
    • /
    • 1997
  • The flowfield generated by a 2-D rotating cylinder on a plane moving at freestream velocity was experimentally investigated in a wind tunnel to simulate aerodynamic characteristics of rotating wheels of an automobile. In the flowfield around a rotating cylinder at 3*10$^{3}$ < Re$_{d}$<8*10$^{3}$, unique mean flow and turbulence characteristics were confirmed by hot-wire measurements as well as frequency analysis, which was supported by flow visualization. In the vicinity of a rotating cylinder, a unique turbulence structure on .root.over bar u'$^{2}$ profiles was formed in hump-like shape at 1 < y/d < 3. A peak frequency which characterized the effect of a rotating cylinder had the same value of the rotation rate of a cylinder. In case of cylinder rotation, the depths of mean velocity -defect and turbulent-shear regions were thickened by 20-40% at 0 < x/d < 10 compared with the case of cylinder stationary. Far downstream beyond x/d > 10, the flowfield generated by a rotating cylinder showed self-similarity in the profiles of mean velocity and turbulence quantities. The effect of a rotating cylinder was independent of its rotation rate and Reynolds number in the measurement range.

Image Analysis for the Simultaneous Measurement of Underwater Flow Velocity and Direction (수중 유속 및 유향의 동시 측정을 위한 이미지 분석 기술에 관한 연구)

  • Dongmin Seo;Sangwoo Oh;Sung-Hoon Byun
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.307-312
    • /
    • 2023
  • To measure the flow velocity and direction in the near field of an unmanned underwater vehicle, an optical measurement unit containing an image sensor and a phosphor-integrated pillar that mimics the neuromasts of a fish was constructed. To analyze pillar movement, which changes with fluid flow, fluorescence image analysis was conducted. To analyze the flow velocity, mean force analysis, which could determine the relationship between the light intensity of a fluorescence image and an external force, and length-force analysis, which could determine the distance between the center points of two fluorescence images, were employed. Additionally, angle analysis that can determine the angles at which pixels of a digital image change was selected to analyze the direction of fluid flow. The flow velocity analysis results showed a high correlation of 0.977 between the external force and the light intensity of the fluorescence image, and in the case of direction analysis, omnidirectional movement could be analyzed. Through this study, we confirmed the effectiveness of optical flow sensors equipped with phosphor-integrated pillars.

Numerical Analysis of Natural Convection from an Inclined Ice Flat Plate Immersed in cold Water Near Its Density Maximum (최대밀도점 부근의 물속에 잠겨있는 경사진 얼음평판에 의한 자연대류의 수치해석)

  • 유갑종;추홍록
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2136-2149
    • /
    • 1992
  • The natural convection from an inclined ice flat plate immersed in cold water near its density maximum is studied numerically. Finite difference analysis has been performed for the heat and momentum transfer with respect to various inclined angles and ambient water temperatures. The results of the analysis are presented for ambient water temperatures, 1.0deg. C. leq. T/sub .inf./.leq. 15.0deg. C and the inclined anales from 0deg to 60deg. They include velocity profiles, temperature profiles, melting velocities, and mean Nusselt numbers for entire flow fields, Generally, in the range of 0deg. C .leq.theta. .leq. 60.deg. C, the results show three distinct flow regimes, In the range of 1.0 deg. C .leq. T/sub .inf./ .leq. 4.6 .deg. C, the greatest mean Nuselt number exists about 3.0deg. C. In the range of 5.7deg. C .leq. T/sub .inf./ .leq. 15.0deg. C, mean Nuselt number increases as ambient water temperature increases. Also, the mean Nuselt number decreases as the inclined angle increases. This theoretical results are compared with previous experimental ones and multiple steady state ones.

Comparison of Leukotriene Receptor Antagonist and Theophylline in Addition to Inhaled Corticosteroid in Adult Asthma: A Meta-Analysis

  • Fang, Huijuan;Wang, Jianmiao;Jin, Di;Cao, Yong;Xu, Yongjian;Xiong, Weining
    • Biomolecules & Therapeutics
    • /
    • v.19 no.3
    • /
    • pp.296-301
    • /
    • 2011
  • This meta-analysis was performed to evaluate the difference of the therapeutic effi cacy and adverse effects of leukotriene receptor antagonist and theophylline added to inhaled corticosteroids in adult asthma. Databases were searched for studies published through Nov, 2010. Randomized-controlled trials containing inhaled corticosteroids plus leukotriene receptor antagonist and inhaled corticosteroids plus sustained-release theophylline for asthma therapy were selected. For each report, data were extracted to the outcomes analyzed: mean change in morning peak expiratory flow, mean change in evening peak expiratory flow, mean change in morning forced expiratory volume in 1 sec, mean change in daily short bete2-agonist use, asthma exacerbation and adverse effects. Four assessable trials including 182 asthmatic patients were identified. Inhaled corticosteroids plus leukotriene receptor antagonist was superior to inhaled corticosteroids plus theophylline therapy in improving morning peak expiratory flow in asthmatics (mean difference 19.08 [95% confidence interval 13.37-23.79] l/min, p<0.001) and morning forced expiratory volume in 1 sec in asthmatics (mean difference 0.09 [95% confidence interval 0.03-0.14] liter, p=0.001). In evening peak expiratory flow, daily short bete2-agonist use, asthma exacerbation and adverse effects, there was no significant difference between these two therapies (All p>0.05). Our meta-analysis showed that the combination of inhaled corticosteroids plus leukotriene receptor antagonist resulted in more improvement in both peak expiratory flow and forced expiratory volume in 1 sec in the morning than inhaled corticosteroids plus sustained-release theophylline in adult asthmatics. Further trials are necessary to evaluate the dominant effects of the former combination.

Measurement of three-dimensional interfacial wave structures in nearly- horizontal countercurrent statified two-phase flow (근사수평 반류성층 2상유동에서의 3차원 계면파의 구조측정)

  • 이상천
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.3
    • /
    • pp.599-606
    • /
    • 1988
  • Structures of interfacial waves in nearly-horizontal countercurrent stratified air-water flow have been measured by means of a needle contact method. Based upon a statistical analysis for the liquid film distribution, statistical properties of the waves such as mean film thickness, mean wave amplitude and rms value of the wave fluctuation have been calculated. The results show that the film distribution can be described by a Gaussian probability density function for the three-dimensional wave regime. It is also indicated that the mean film thick ness and the rms value of the wave fluctuation increase as gas and liquid flow rates are increased in countercurrent two-phase flow. The dimensionless intensity of the wave fluctuation may be regarded as a function of the Froude number and the dimensionless mean film thickness.

Numerical Analysis on Recirculation Generated by Obstacles around a Cooling Tower (냉각탑 주위의 장애물에 의한 재순환 현상에 관한 수치해석)

  • Lee Jung-Hee;Choi Young-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.578-586
    • /
    • 2006
  • The present study has been conducted to examine the effect of obstacles around a cooling tower and an air-guide to prevent recirculation. In order to analyze the interaction between external flow and cooling tower exit flow, the external region as well as the cooling, tower are included in computational domain. Two dimensional analysis is performed using the finite volume method with non-orthogonal and unstructured grid system. The standard ${\kappa}-{\varepsilon}$ turbulence model is used. To investigate the recirculation phenomena, flow and temperature fields are calculated with three approaches such as, the distance between cooling tower and obstacle, the allocated geometrical type, and the effect of height of obstacle. In addition, the air-guide is considered in the current computation. The mean recirculation rate increases with the height of obstacle. The effect of air-guide to reduce the mean recirculation rate is obviously observed.

Structure Analyses of Rubber/Filler System under Shear Flow by Using Time Resolved USAXS Method

  • Nishitsuji, Shotaro;Takenaka, Mikihito;Amino, Naoya;Ishikawa, Yasuhiro
    • Elastomers and Composites
    • /
    • v.54 no.2
    • /
    • pp.156-160
    • /
    • 2019
  • The changes in the dispersion of carbon black in liquid polyisoprene under shear flow with time have been investigated by time-resolved ultra small-angle X-ray scattering (USAXS) method. The analyses of USAXS profile immediately after the start of shear flow clarified that the aggregates of carbon black with a mean radius of gyration of 14 nm and surface fractal dimension of 2.5 form the fractal network structure with mass-fractal dimension of 2.9. After the application of the shear flow, the scattering intensity increases with time at the observed whole entire q region, and then the a shoulder appears at $q=0.005nm^{-1}$, indicating that the agglomerate is broken and becomes smaller by shear flow. The analysis by the Unified Guinier/Power-law approach yielded several characteristic parameters, such as the sizes of aggregate and agglomerate, mass-fractal dimension of agglomerate, and surface fractal dimension of the primary particle. While the mean radius of gyration of the agglomerate decreases with time, the mean radius of gyration of the aggregate, mass fractal dimension, and surface fractal dimension don't change with time, indicating that the aggregates peel off the surface of the agglomerate.

Fluid Flow Analysis of the Threshold based Leaky Bucket Scheme

  • Park, Chul-Geun
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.2
    • /
    • pp.274-279
    • /
    • 1998
  • We investigate a Leaky Bucket(LB) scheme with a threshold in the data buffer, where leaky rate changes depending on the contents of data buffer. We use the fluid flow model for the analysis of the LB scheme with a threshold. We model the bursty input source as markov modulated fluid flow(MMFF) As performance measures we obtain loss probability and mean delay. We present some numerical results to show the effects of the level of a threshold, the rate of token generation, the size of token pool, and the size the data buffer on the performances of the LB scheme with a threshold.

  • PDF

PIV Analysis of the Flow Inside a Home Refrigerator and the Design of a Higher Efficiency Cooling Duct (PIV 계측을 이용한 가정용 냉장고의 냉기 유동특성 파악과 고효율 냉기 유로 설계)

  • Choi, Jay-Ho;Cho, Sung-Ho;Nam, Young-Sok;Lee, In-Seop
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.405-409
    • /
    • 2001
  • An experimental analysis of the flow inside the refrigeration compartment of a home refrigerator was conducted in order to achieve better performances in terms of uniform temperature distribution and cooling speed. 2D PIV and stereoscopic PIV were used for the experiments on an actual-size refrigerator at operating conditions. Two CCD cameras were employed for a wider field of view in the measurement of the shelf, and stereoscopic PIV was used to measure the three velocity components at the various cooling duct outlets and the mean velocity fields were area-integrated to calculate the flow-rates. 50 to 100 instantaneous velocity fields were time averaged for the mean velocity fields. With the result of this analysis, a new cooling duct system was developed, with the refrigerator's cooling performance increasing 11% in terms of cooling speed, and 25% in temperature uniformity.

  • PDF

Numerical analysis of flow characteristics with intake port and valve design (흡기포트 및 밸브 형상에 따른 정상 유동 특성)

  • Lee, Sang-Jin;Kim, Seong-Cheol;Kim, Duk-Sang;Ohm, In-Yong;Cho, Yong-Seok
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.921-927
    • /
    • 2001
  • Steady flow bench test is a practical, powerful and widely used test in most engine manufacturers to give a design concept of a new engine. In order to use steady data as a performance index, it is necessary to build some database, which can correlate the port characteristics with engine data. However, it is very hard to investigate all port and valve shapes with experimental tools. The steady flow scheme is relatively simple and its results are bulk ones such as flow rate and momentum of flow. Therefore a CFD code can be easily applied to the port evaluation. In this study, the steady flow test was simulated through two and three-dimensional analysis on intake port design for comparing with experimental data and confirming the feasibility of applying analytic method. For this purpose, the effect of valve curvature on flow rate was estimated by a CFD code. There results were compared with those of real steady flow tests. As a result, the 2-D analysis described the phenomena qualitatively well, and also the results of 3-D analysis were almost consistent with experimental data.

  • PDF