• Title/Summary/Keyword: Mean Diameter

Search Result 1,905, Processing Time 0.03 seconds

Prediction of Mean Diameters Based on the Instability Theory for Twin Fluid Nozzle (불안정 이론을 이용한 2유체 노즐에서의 분무입경 예측)

  • Kim, Gwan-Tae;An, Guk-Yeong;Kim, Han-Seok
    • 연구논문집
    • /
    • s.25
    • /
    • pp.47-54
    • /
    • 1995
  • The atomizing characteristics in a spray injected from a twin fluid atomization nozzle have been investigated. The Sauter mean diameters as mean diameter are compared with wavelength calculated from the instability theory. The Sauter mean diameter are measured by the Fraunhofer diffraction theory using the Malvern particle sizer. The wavelength is calculated using the mean relative velocity instead of the exit relative velocity of nozzle. Also shadowgraphy technique is used to visualize atomization. This paper gives a possibility that the mean diameter can be predicted with the wavelength obtained by the simple instability theory.

  • PDF

Prediction of Mean Diameters Based on the Instability Theory for Twin Fluid Nozzle (불안정 이론을 이용한 2유체 노즐에서의 분무입경예측)

  • Kim, Kwan-Tae;Ahn, Kook-Young;Kim, Han-Seok;Ryu, Jeong-In
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.1
    • /
    • pp.57-64
    • /
    • 1996
  • The atomizing characteristics in a spray injected from a twin fluid atomization nozzle have been investigated. The Sauter mean diameters as mean diameter are compared with wavelength calculated from the instability theory. The Sauter mean diameter are measured by the Fraunhofer diffraction theory using the Malvern particle sizer. The wavelength is calculated using the mean relative velocity instead of the exit relative velocity of nozzle. Also shadowgraphy technique is used to visualize atomization phenomena. This paper gives a possibility that the mean diameter can be predicted with the wavelength obtained by the simple instability theory.

  • PDF

Effect of Injector Energizing Duration on the Atomization Characteristics of Biodiesel Fuel (인젝터 통전기간이 바이오디젤 연료 미립화에 미치는 영향)

  • Suh, Hyun-Kyu;Park, Su-Han;Lee, Chang-Sik
    • Journal of ILASS-Korea
    • /
    • v.12 no.2
    • /
    • pp.108-114
    • /
    • 2007
  • This study investigates the influence of energizing duration on the fuel atomization characteristics of biodiesel injected through a high pressure common-rail injector. In order to analyze the effect of energizing duration on the fuel injection rate performance, the injection rate of biodiesel fuel is obtained from the pressure variation in the tube filled with fuel in injection measuring system. On the other hand, the atomization characteristics of biodiesel was measured and compared in terms of Sauter mean diameter(SMD), arithmetic mean diameter(AMD), droplet mean velocity, and detected droplets number by applying a phase Doppler particle analyzer(PDPA). It was revealed that the injection mass and maximum injection rate increase with increase of the energizing duration. Moreover, the increase of energizing duration improves the atomization performance of biodiesel fuel because it induces higher droplets momentum and velocity.

  • PDF

A Study on the Droplet Size Distribution of Ultra High Pressure Diesel Spray on Electronic Hydraulic Fuel Injection System (전자유압식 분사계에 의한 초고압 디젤분무의 입경분포에 관한 연구)

  • Jang, S.H.;Ahn, S.K.
    • Journal of Power System Engineering
    • /
    • v.2 no.1
    • /
    • pp.25-30
    • /
    • 1998
  • In order to investigate the droplet size distribution and Sauter Mean Diameter in a ultra high pressure diesel spray, fuel was injected with ultra high pressure into the environments of high pressure and room temperature by an Electronic Hydraulic Fuel Injection System. Droplet size was measured with the immersion liquid sampling technique. The immersion liquid was used a mixture of water-methycellulose solution and ethanol. The Sauter Mean Diameter decreased with increasing injection pressure, with a decrease environmental pressure (back pressure) and nozzle diameter. Increasing the injection pressure makes the fuel density distribution of the spray more homogeneous. An empirical correlation was developed among injection pressure, air density, nozzle diameter and the Sauter Mean Diameter of spray droplets.

  • PDF

Normal Corpus Callosum Dimensions Measured by MRI (MR Midsagittal 영상을 이용한 정상 뇌량의 크기 측정)

  • Kim, Ham-Gyum
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.277-285
    • /
    • 2008
  • As a result of measuring the size of corpus callosum in normal Korean people by using MRI, the following conclusions were obtained. 1. Maximum, minimum, and mean values by the region in whole subjects 1) Anteroposterior length amounted to the mean with 69.30mm, the minimum with 50.70mm, and the maximum with 80.40mm. 2) Diameter of genu amounted to the mean with 11.93mm, the minimum with 6.00mm, and the maximum with 18.50mm. 3) Diameter of mid body amounted to the mean with 7.00mm, the minimum with 3.40mm, and the maximum with 10.40mm. 4) Diameter of narrowing portion amounted to the mean with 4.51mm, the minimum with 0.80mm, and the maximum with 9.50mm. 5) Diameter of splenium amounted to the mean with 12.17mm, the minimum with 6.90mm, and the maximum with 17.20mm. 2. Comparison by region according to the gender in the whole subjects 1) Anteroposterior length was bigger in men than in women, and showed the significant difference depending on gender. 2) Diameter of genu, diameter of mid body, and diameter of narrowing portion were bigger in men than in women, but there was no significant difference. 3) Diameter of splenium was bigger in men than in women, and showed the statistically significant difference. 3. Comparison by region according to the age in the whole subjects 1) Anteroposterior length was the biggest in the 50s at the age, and was smaller in heir 10s than other age levels. In addition, the significant difference was indicated depending on age. 2) Diameter of genu and diameter of mid body were the biggest in their 30s, and were smaller in the 60s than other age levels. And, the statistically significant difference was indicated. 3) Diameter of narrowing portion was the thickest in their 20s, and was thinner in their 60s than other age levels. And, the significant difference was indicated depending on age. 4) Diameter of splenium was the thickest in their 30s, and was thinner in their 10s than other age levels. And, the statistically significant difference was indicated. 4. Correlation by region in whole subjects 1) Diameter of genu showed the statistically significant positive correlation with anteroposterior length. 2) Diameter of mid body showed the statistically significant positive correlation with anteroposterior length and diameter of genu. 3) Diameter of narrowing portion didn't show the statistically significant correlation with anteroposterior length, but showed the statistically significant positive correlation with diameter of genu and diameter of mid body. 4) Diameter of splenium showed the statistically significant positive correlation with anteroposterior length, diameter of genu, diameter of mid body, and diameter of narrowing portion.

  • PDF

Hemodynamic Effects on Artery-Graft Anastomotic Intimal Hyperplasia (혈류의 유동이 혈관-인조혈관 접속부 혈관 내막 세포증식에 미치는 영향)

  • 이계한
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.2
    • /
    • pp.143-150
    • /
    • 1994
  • Wall shear rate or stress is believed to be a major hemodynamic variable influencing atherosclerosis and artery-graft anastomic intimal hyperplasia. The purpose of this study is to verify the effects of radial wall motion, artery-graft compliance and diameter mismatch, and impedance phase angle on the wall shear rate distribution near an end-to-end artery-graft anastomosis model. The results show that radial wall motion of the elastic artery model lowers the mean wall shear rates under pulsatile flow condition by 15 to 20 % comparing to those under steady flow condition at the same mean flow rate. Impedance phase angle seems to have small effects on the mean and amplitude of the wall shear rate distribution. In order to study the effects of compliance and diameter mismatch on the wall shear rates, two models are studied-Model I has 6% and Model I has 6% and Model II has 11% smaller graft diameter. Divergent geometry caused by diameter mismatch near the distal sites reduces the mean wall shear rates significantly, and this low shear region is believed to be prone to intimal hyperplasia.

  • PDF

Behavior Characteristics of Swirl-Twin Spray with Changing Swirl Angle (선회각도변화에 따른 2유체 선회분무의 거동특성)

  • Kang, Wan-Bong;Cha, Keun-Jong;Kim, Duck-Jool
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.943-948
    • /
    • 2000
  • The Twin-fluid Swirl Nozzles are used in many parts of the industry to produce homogeneous spray. This study is to investigate the effects of outer air swiller and inner water swiller on atomization of liquid.. The experiment was carried out with increasing air-flow rate at constant liquid-flow rate and with changing outer air swiller angle and inner water swiller angle. A Particle Dynamics Analyzer(PDA) was used to measure drop size, mean and ms values of axial velocity, number density and Sauter mean diameter(SMD). The axial mean velocity and SMD of droplets were measured along the center line and radial directions. It was found that the higher air flow-rate resulted in the smaller Sauter mean diameter of liquid spray and the higher axial mean velocity of droplets. This experimental results will be conveniently used for the preliminary design stage of twin-fluid nozzle development.

  • PDF

Uncertainty improvement in measurement of mean diameter of 0.3-$\mu\textrm{m}$-diameter polystyrene sphere by using quasi-elastic light scattering (준탄성광산란을 이용한 0.3 $\mu\textrm{m}$ 폴리스티렌구의 평균지름 측정 불확도 향상)

  • 박병천;정명세
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.4
    • /
    • pp.258-263
    • /
    • 1998
  • Quasi-elastic light scattering is utilized to measure the mean diameter of the 0.3 $\mu\textrm{m}$-dimeter polystyrene sphere. The mean diameter of the polystyrene sphere is required to be known within the uncertainty of a few per centages. The systematic error has been considerably reduced by improving the system for the angle alignment and temperature measurement of cell. NIST SRM 1691 (0.269$\pm$0.007 $\mu\textrm{m}$: TEM; 0.275$\pm$0.007 $\mu\textrm{m}$: QELS) is measured to be 0.273 $\mu\textrm{m}$$\pm$0.006 $\mu\textrm{m}$ in mean diameter. Detailed description is given of the improved method and the resultant uncertainty, and the comparison of results with NIST is followed.

  • PDF

Lightweight Algorithm for Digital Twin based on Diameter Measurement using Singular-Value-Decomposition (특이값 분해를 이용한 치수측정 기반 디지털 트윈 알고리즘 경량화)

  • Seungmin Lee;Daejin Park
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.18 no.3
    • /
    • pp.117-124
    • /
    • 2023
  • In the machine vision inspection equipment, diameter measurement is important process in inspection of cylindrical object. However, machine vision inspection equipment requires complex algorithm processing such as camera distortion correction and perspective distortion correction, and the increase in processing time and cost required for precise diameter measurement. In this paper, we proposed the algorithm for diameter measurement of cylindrical object using the laser displacement sensor. In order to fit circle for given four input outer points, grid search algorithms using root-mean-square error and mean-absolute error are applied and compared. To solve the limitations of the grid search algorithm, we finally apply the singular-value-decomposition based circle fitting algorithm. In order to compare the performance of the algorithms, we generated the pseudo data of the outer points of the cylindrical object and applied each algorithm. As a result of the experiment, the grid search using root-mean-square error confirmed stable measurement results, but it was confirmed that real-time processing was difficult as the execution time was 10.8059 second. The execution time of mean-absolute error algorithm was greatly improved as 0.3639 second, but there was no weight according to the distance, so the result of algorithm is abnormal. On the other hand, the singular-value-decomposition method was not affected by the grid and could not only obtain precise detection results, but also confirmed a very good execution time of 0.6 millisecond.

Spray Characteristics of Fuel Injector in DI Diesel Engine (직접 분사식 디젤 기관 인젝터의 연료 분무 특성)

  • 이창식;김민규;전원식;진다시앙
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.5
    • /
    • pp.75-81
    • /
    • 2001
  • This paper presents the atomization characteristics of single hole injector in the direct injection type diesel engine. The spray characteristics of fuel injector such as the droplet size and velocity were measured by phase Doppler particle analyzer. In this paper, the atomization characteristics of fuel spray are investigated for the experimental analysis of the measuring data by the results of mean diameter and mean velocity of droplet. The effect of fuel injection pressure on the droplet size shows that the higher injection pressure results in the decrease of mean droplet diameter in the fuel spray. The minimum size of fuel spray droplet appears on the location of 40mm axial distance from nozzle exit of diesel injector. Based on the experimental results, the correlation between the droplet diameter and mean velocity of the diesel spray due to the change of axial and radial distance from the nozzle tip were investigated.

  • PDF