• 제목/요약/키워드: Mean Diameter

검색결과 1,905건 처리시간 0.023초

불안정 이론을 이용한 2유체 노즐에서의 분무입경 예측 (Prediction of Mean Diameters Based on the Instability Theory for Twin Fluid Nozzle)

  • 김관태;안국영;김한석
    • 연구논문집
    • /
    • 통권25호
    • /
    • pp.47-54
    • /
    • 1995
  • The atomizing characteristics in a spray injected from a twin fluid atomization nozzle have been investigated. The Sauter mean diameters as mean diameter are compared with wavelength calculated from the instability theory. The Sauter mean diameter are measured by the Fraunhofer diffraction theory using the Malvern particle sizer. The wavelength is calculated using the mean relative velocity instead of the exit relative velocity of nozzle. Also shadowgraphy technique is used to visualize atomization. This paper gives a possibility that the mean diameter can be predicted with the wavelength obtained by the simple instability theory.

  • PDF

불안정 이론을 이용한 2유체 노즐에서의 분무입경예측 (Prediction of Mean Diameters Based on the Instability Theory for Twin Fluid Nozzle)

  • 김관태;안국영;김한석;류정인
    • 한국연소학회지
    • /
    • 제1권1호
    • /
    • pp.57-64
    • /
    • 1996
  • The atomizing characteristics in a spray injected from a twin fluid atomization nozzle have been investigated. The Sauter mean diameters as mean diameter are compared with wavelength calculated from the instability theory. The Sauter mean diameter are measured by the Fraunhofer diffraction theory using the Malvern particle sizer. The wavelength is calculated using the mean relative velocity instead of the exit relative velocity of nozzle. Also shadowgraphy technique is used to visualize atomization phenomena. This paper gives a possibility that the mean diameter can be predicted with the wavelength obtained by the simple instability theory.

  • PDF

인젝터 통전기간이 바이오디젤 연료 미립화에 미치는 영향 (Effect of Injector Energizing Duration on the Atomization Characteristics of Biodiesel Fuel)

  • 서현규;박수한;이창식
    • 한국분무공학회지
    • /
    • 제12권2호
    • /
    • pp.108-114
    • /
    • 2007
  • This study investigates the influence of energizing duration on the fuel atomization characteristics of biodiesel injected through a high pressure common-rail injector. In order to analyze the effect of energizing duration on the fuel injection rate performance, the injection rate of biodiesel fuel is obtained from the pressure variation in the tube filled with fuel in injection measuring system. On the other hand, the atomization characteristics of biodiesel was measured and compared in terms of Sauter mean diameter(SMD), arithmetic mean diameter(AMD), droplet mean velocity, and detected droplets number by applying a phase Doppler particle analyzer(PDPA). It was revealed that the injection mass and maximum injection rate increase with increase of the energizing duration. Moreover, the increase of energizing duration improves the atomization performance of biodiesel fuel because it induces higher droplets momentum and velocity.

  • PDF

전자유압식 분사계에 의한 초고압 디젤분무의 입경분포에 관한 연구 (A Study on the Droplet Size Distribution of Ultra High Pressure Diesel Spray on Electronic Hydraulic Fuel Injection System)

  • 장세호;안수길
    • 동력기계공학회지
    • /
    • 제2권1호
    • /
    • pp.25-30
    • /
    • 1998
  • In order to investigate the droplet size distribution and Sauter Mean Diameter in a ultra high pressure diesel spray, fuel was injected with ultra high pressure into the environments of high pressure and room temperature by an Electronic Hydraulic Fuel Injection System. Droplet size was measured with the immersion liquid sampling technique. The immersion liquid was used a mixture of water-methycellulose solution and ethanol. The Sauter Mean Diameter decreased with increasing injection pressure, with a decrease environmental pressure (back pressure) and nozzle diameter. Increasing the injection pressure makes the fuel density distribution of the spray more homogeneous. An empirical correlation was developed among injection pressure, air density, nozzle diameter and the Sauter Mean Diameter of spray droplets.

  • PDF

MR Midsagittal 영상을 이용한 정상 뇌량의 크기 측정 (Normal Corpus Callosum Dimensions Measured by MRI)

  • 김함겸
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권3호
    • /
    • pp.277-285
    • /
    • 2008
  • MRI를 이용하여 정상의 뇌량 크기를 측정한 결과 다음과 같은 결론을 얻었다. 1. 전체 대상자의 부위별 평균, 최소, 최대 1) Anteroposterior length는 평균 69.30mm, 최소 50.70mm, 최대 80.40mm이었다. 2) Diameter of genu는 평균 11.93mm, 최소 6.00mm, 최대 18.50mm이었다. 3) Diameter of mid body는 평균 7.00mm, 최소 3.40mm, 최대 10.40mm이었다. 4) Diameter of narrowing portion은 평균 4.51mm, 최소 0.80mm, 최대 9.50mm이었다. 5) Diameter of splenium은 평균 12.17mm, 최소 6.90mm, 최대 17.20mm이었다. 2. 전체 대상자의 성별에 따른 부위별 비교 1) Anteroposterior length는 남자가 여자보다 컸으며, 성별에 따라 유의미한 차이를 보였다. 2) Diameter of genu와 diameter of mid body, diameter of narrowing portion은 남자가 여자보다 컸으나 유의미한 차이는 아니었다. 3) Diameter of splenium은 남자가 여자보다 컸으며, 통계적으로도 유의미한 차이를 보였다. 3. 전체 대상자의 부위별 상관관계 1) Diameter of genu는 anteroposterior length와 통계적으로 유의미한 정적 상관관계를 보였다. 2) Diameter of mid body는 anteroposterior length, diameter of genu와 통계적으로 유의미한 정적 상관 관계를 보였다. 3) Diameter of narrowing portion은 anteroposterior length와 통계적으로 유의미한 상관관계를 보이지 않았으나 diameter of genu, diameter of mid body와 통계적으로 유의미한 정적 상관관계를 보였다. 4) Diameter of splenium은 anteroposterior length와 diameter of genu, diameter of mid body, 그리고 diameter of narrowing portion과 통계적으로 유의미한 정적 상관관계를 보였다.

  • PDF

혈류의 유동이 혈관-인조혈관 접속부 혈관 내막 세포증식에 미치는 영향 (Hemodynamic Effects on Artery-Graft Anastomotic Intimal Hyperplasia)

  • 이계한
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권2호
    • /
    • pp.143-150
    • /
    • 1994
  • Wall shear rate or stress is believed to be a major hemodynamic variable influencing atherosclerosis and artery-graft anastomic intimal hyperplasia. The purpose of this study is to verify the effects of radial wall motion, artery-graft compliance and diameter mismatch, and impedance phase angle on the wall shear rate distribution near an end-to-end artery-graft anastomosis model. The results show that radial wall motion of the elastic artery model lowers the mean wall shear rates under pulsatile flow condition by 15 to 20 % comparing to those under steady flow condition at the same mean flow rate. Impedance phase angle seems to have small effects on the mean and amplitude of the wall shear rate distribution. In order to study the effects of compliance and diameter mismatch on the wall shear rates, two models are studied-Model I has 6% and Model I has 6% and Model II has 11% smaller graft diameter. Divergent geometry caused by diameter mismatch near the distal sites reduces the mean wall shear rates significantly, and this low shear region is believed to be prone to intimal hyperplasia.

  • PDF

선회각도변화에 따른 2유체 선회분무의 거동특성 (Behavior Characteristics of Swirl-Twin Spray with Changing Swirl Angle)

  • 강완봉;차건종;김덕줄
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.943-948
    • /
    • 2000
  • The Twin-fluid Swirl Nozzles are used in many parts of the industry to produce homogeneous spray. This study is to investigate the effects of outer air swiller and inner water swiller on atomization of liquid.. The experiment was carried out with increasing air-flow rate at constant liquid-flow rate and with changing outer air swiller angle and inner water swiller angle. A Particle Dynamics Analyzer(PDA) was used to measure drop size, mean and ms values of axial velocity, number density and Sauter mean diameter(SMD). The axial mean velocity and SMD of droplets were measured along the center line and radial directions. It was found that the higher air flow-rate resulted in the smaller Sauter mean diameter of liquid spray and the higher axial mean velocity of droplets. This experimental results will be conveniently used for the preliminary design stage of twin-fluid nozzle development.

  • PDF

준탄성광산란을 이용한 0.3 $\mu\textrm{m}$ 폴리스티렌구의 평균지름 측정 불확도 향상 (Uncertainty improvement in measurement of mean diameter of 0.3-$\mu\textrm{m}$-diameter polystyrene sphere by using quasi-elastic light scattering)

  • 박병천;정명세
    • 한국광학회지
    • /
    • 제9권4호
    • /
    • pp.258-263
    • /
    • 1998
  • 준탄성광산란(QELS)을 이용하여 지름이 0.3$\mu\textrm{m}$인 폴리스티렌구의 평균지름을 측정하였다. 폴리스티렌구가 표준입자로 사용되기 위하여는 평균지름의 불확도가 수 % 이내가 되어야 한다. 본 연구에서는 QELS장차중 시료용기의 정렬방법 및 온도측정방법을 특별히 보완하여 계통오차를 대폭 줄였다. 표준입자 인증물질인 NIST SRM 1691 (0.269$\pm$0.007$\mu\textrm{m}$: TEM; 0.275$\pm$0.007$\mu\textrm{m}$:QELS)을 측정하여 평균지름이 0.2730.006$\mu\textrm{m}$ 인 결과를 얻었다. 개선된 측정방법 및 측정불확도를 상세히 기술하였으며 NIST의 측정결과와 비교하였다.

  • PDF

특이값 분해를 이용한 치수측정 기반 디지털 트윈 알고리즘 경량화 (Lightweight Algorithm for Digital Twin based on Diameter Measurement using Singular-Value-Decomposition)

  • 이승민;박대진
    • 대한임베디드공학회논문지
    • /
    • 제18권3호
    • /
    • pp.117-124
    • /
    • 2023
  • In the machine vision inspection equipment, diameter measurement is important process in inspection of cylindrical object. However, machine vision inspection equipment requires complex algorithm processing such as camera distortion correction and perspective distortion correction, and the increase in processing time and cost required for precise diameter measurement. In this paper, we proposed the algorithm for diameter measurement of cylindrical object using the laser displacement sensor. In order to fit circle for given four input outer points, grid search algorithms using root-mean-square error and mean-absolute error are applied and compared. To solve the limitations of the grid search algorithm, we finally apply the singular-value-decomposition based circle fitting algorithm. In order to compare the performance of the algorithms, we generated the pseudo data of the outer points of the cylindrical object and applied each algorithm. As a result of the experiment, the grid search using root-mean-square error confirmed stable measurement results, but it was confirmed that real-time processing was difficult as the execution time was 10.8059 second. The execution time of mean-absolute error algorithm was greatly improved as 0.3639 second, but there was no weight according to the distance, so the result of algorithm is abnormal. On the other hand, the singular-value-decomposition method was not affected by the grid and could not only obtain precise detection results, but also confirmed a very good execution time of 0.6 millisecond.

직접 분사식 디젤 기관 인젝터의 연료 분무 특성 (Spray Characteristics of Fuel Injector in DI Diesel Engine)

  • 이창식;김민규;전원식;진다시앙
    • 한국자동차공학회논문집
    • /
    • 제9권5호
    • /
    • pp.75-81
    • /
    • 2001
  • This paper presents the atomization characteristics of single hole injector in the direct injection type diesel engine. The spray characteristics of fuel injector such as the droplet size and velocity were measured by phase Doppler particle analyzer. In this paper, the atomization characteristics of fuel spray are investigated for the experimental analysis of the measuring data by the results of mean diameter and mean velocity of droplet. The effect of fuel injection pressure on the droplet size shows that the higher injection pressure results in the decrease of mean droplet diameter in the fuel spray. The minimum size of fuel spray droplet appears on the location of 40mm axial distance from nozzle exit of diesel injector. Based on the experimental results, the correlation between the droplet diameter and mean velocity of the diesel spray due to the change of axial and radial distance from the nozzle tip were investigated.

  • PDF