• 제목/요약/키워드: Maxwell- Wien bridge

검색결과 3건 처리시간 0.016초

인덕턴스의 국가 표준 확입을 위한 막스웰-윈 브릿지 연구 개발 (Development of Maxwell-Wien Bridge System for Extablishment of Inductance Primary Standards)

  • 이래덕;도재홍;김창석
    • 대한전자공학회논문지
    • /
    • 제20권4호
    • /
    • pp.36-40
    • /
    • 1983
  • 일반적인 교류 브릿지를 이용하여 인덕턴스를 0.1% 이상의 정확도로 측정한다는 것은 대단히 어려운 일이다. 따라서 인덕턱스의 표준을 설정하고 이에 대한 표준 공급을 가능케하기 위해서 막스웰 ―윈 브릿지 시스템을 개발하였다. 브릿지 시스템의 성능을 분석한 결과, 현재 ±200ppm의 정확도로 인덕턴스의 측정이 가능케 되었다.

  • PDF

Establishment of a National Primary Inductance Standard Unit

  • Kim Han Jun;Lee Rae Duk;Semenov Yu. P.;Han Sang Ok
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권3호
    • /
    • pp.283-288
    • /
    • 2005
  • A portable primary inductance standard set that includes a Maxwell-Wien bridge and a 10 mH standard inductor installed in a thermostat has been developed at KRISS. Two auxiliary resistance capacitance networks (analogous to a 'Wagner ground') provide excellent stability of the bridge balance and impose less strict requirements on the components of these networks. Removable capacitance and ac-dc resistance standards used in the bridge arms made it possible to reproduce 10 mH and 100 mH inductance values in the frequency range of 500 Hz to 3 kHz. From investigations of this standard and preliminary comparison with VNIIM (D. I. Mendeleyev Institute for Metrology), the results have demonstrated that the bridge can be used as a part of the transportable inductance standard with a measurement uncertainty within (1-3) $\mu$H/H at frequencies of 1 kHz and 1.6 kHz. The application of the bridge as a constituent part of the transportable standard gives us an opportunity to eliminate the influence of the standard inductors.

Development of Optical Signal Transmission for the KSTAR Project Pertaining to Instrumentation and Control of the Neutral Beam Test Stand at KAERI

  • Jung, Ki-Sok;Oh, Byung-Hoon
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권3호
    • /
    • pp.289-295
    • /
    • 2005
  • Instrumentation and Control (I&C) of the Neutral Beam Test Stand (NB- TS) Facility at the Korea Atomic Energy Research Institute (KAERI) for the Korea Superconducting Tokamak Advanced Research (KSTAR) project has been underway since the start of the project to answer the diverse requests arising from the various facets of the development and construction phases of the project. Optical signal transmission constitutes a significant portion of I&C works and has been performed for the entirety of the project. During the NB- TS construction and related experiments, significant achievements to a more accurate as well as more refined optical signal transmissions have been made. Examples of those I&C works that utilized the optical signal transmission are the Langmuir probe signal transmission, gradient grid current signal transmission, gas flow control and signal transmission, ion source temperature measurement, beam line component temperature monitoring, and coolant flow signal transmission, etc. These optical signal transition provisions are now performing part of the indispensable functions for the proper operation of the NB- TS facility. Attained experience and expertise are expected to be well applied to the upcoming main neutral beam injection (NBI) system construction for the KSTAR project.