• Title/Summary/Keyword: Maximum residual level

Search Result 117, Processing Time 0.027 seconds

Effect of Heat Treatment Conditions and Densities on Residual Stresses at Hybrid (FLN2-4405) P/M Steels

  • Kafkas, Firat;Karatas, Cetin;Saritas, Suleyman
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.566-567
    • /
    • 2006
  • The characteristics of residual stresses occurring in PM steel based nickel (FLN2-4405) was investigated. The measurements of residual stresses were carried out by electrochemical layer removal technique. The values and distributions of residual stresses occurring in PM steel processed under various densities and heat treatment conditions were determined. In most of the experiments, tensile residual stresses were recorded in surface of samples. The residual stress distribution on the surface of the PM steels is affected by the heat treatment conditions and density. Maximum values of residual stresses on the surface were observed sinter hardened condition and $7.4\;g/cm^3$ density. Minimum level of recorded tensile residual stresses are150 MPa and its maximum level is 370 MPa.

  • PDF

A Study on Residual DC Characteristics in the in-plane Switching Liquid Crystal Display by Light Minimum/Maximum Method (광 최소/최대법을 이용한 IPS-LCD의 잔류 DC특성 연구)

  • 김향율;한은주;서대식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.7
    • /
    • pp.590-594
    • /
    • 2001
  • The residual DC properties in the in-plane switching (IPS) liquid crystal displays(LCDs) which have different concentrations of cynao NLCs and different resistivities of fluorine NLCs were studied. We also propose a new residual DC measurement method, named 'light minimum/maximum method'. We confirmed the precision of residual DC measurement by light minimum/maximum method compared with the flicker minimizing method and found that new measurement method of residual DC is more accurate than that of the conventional flicker minimizing method since the resolution level of measurements is in 0.1V.

  • PDF

Measurement of Residual DC Voltage in the IPS-LCD by Light Minimum/Maximum Method (광 최소/최대법을 이용한 IPS-LCD의 잔류 DC 전압 측정)

  • Jeon, Yong-Je;Kim, Hyang-Yul;Kim, Jae-Hyung;Hahn, Eun-Joo;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.354-357
    • /
    • 2001
  • The residual DC properties in the in-plane switching (IFS) liquid crystal displays(LCDs) which have different concentrations of cynao NLCs and different resistivities of fluorine NLCs were studied. We also propose a new residual DC measurement method, named 'light minimum/maximum method'. We confirmed the precision of residual DC measurement by light minimum/maximum method compared with the flicker minimizing method and found that new measurement method of residual DC is better than that of the conventional flicker minimizing method since the resolution level of measurements is in 0.1V

  • PDF

Measurement of Residual DC Voltage in the IPS-LCD by Light Minimum/Maximum Method (광 최소/최대법을 이용한 IPS-LCD의 잔류 DC 전압 측정)

  • 전용제;김향율;김재형;한은주;서대식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.354-357
    • /
    • 2001
  • The residual DC properties in the in-plane switching (IPS) liquid crystal displays(LCDs) which have different concentrations of cynao NLCs and different resistivities of fluorine NLCs were studied. We also propose a new residual DC measurement method, named 'light minimum/maximum method'. We confirmed the precision of residual DC measurement by light minimum/maximum method compared with the flicker minimizing method and found that new measurement method of residual DC is better than that of the conventional flicker minimizing method since the resolution level of measurements is in 0.1 V

  • PDF

Criteria of Impact Resistance of Lightweight Wall by the Large Soft Body (건식 경량벽체의 연질 충격체에 의한 내충격성 판정기준에 관한 연구)

  • Kim, Ki Jun;Song, Jung Hyeon;Choi, Soo Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.102-103
    • /
    • 2014
  • Due to the nature of the existing load, the criteria of assessing the intensity of the lightweight wall's impact resistance has been though of as obscure. The current study, therefore, focuses on the standardized assessment of the impact resistance to the force of the large soft body applying to the lightweight wall. The gypsum board wall showed a low level of the maximum residual displacement. It is, however, required to be careful about the selection of the finishing process since the high level of the maximum displacement is likely to cause harm to finishing materials. Unlike the gypsum board, the ALC block wall displayed a considerable rigidity while showing almost no maximum residual displacement. Even with the low level of the maximum displacement due to the stiffness, the ALC block wall is still likely to be affected by the vibration derived from any impact on the surface, which demands a need for additional study. The future experimental study, accordingly, will focus on the impact of the vibration on finishing materials, consequently leading to the accurate prediction of the possibility of potential damage to the lightweight wall caused by the large soft body.

  • PDF

The Effect of Compressive Residual Stress on The Fatigue life in Spring Steel for vehicles (차량용 스프링강의 피로균열진전에 미치는 압축잔류응력의 영향)

  • 박경동;하경준;박형동
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.82-90
    • /
    • 2003
  • Nowadays, many components used in machinery industry is required lightness and high strength. The shot-peening method is used in order to improve the fatigue life of spring steel(JIS G SUP-9) which is used in suspension of automobile. The compressive residual is induced in this shot-peening process. This paper investigated the effect of the residual compressive stress on the fatigue crack growth characteristics. Main results are summarized as follows. 1. The fatigue crack growth rate on stage II is conspicuous with the level of compressive residual stress and is dependent on Paris equation. 2. Although the maximum compressive residual stress is deeply and widely formed from surface, it does not improve the fatigue life comparing when maximum compressive residual stress is formed in surface. 3. The threshold stress intensity factor range is increased with increasing compressive residual stress. 4. In fracture surface of fatigue crack growth it is investigated that compressive residual stress remarkably retards fatigue crack growth.

Determination of Simultaneous Analytical Method of Residual Pesticides by Gas Chromatography (기체크로마토그래피를 이용한 잔류농약 동시다성분 분석법)

  • Choi, Won-Jo;Choi, Gye-Sun;Lee, Hee-Jung;Won, Young-Jun;Park, Heung-Jai;Kim, Woo-Seong
    • Journal of Environmental Science International
    • /
    • v.18 no.12
    • /
    • pp.1369-1381
    • /
    • 2009
  • The simultaneous determination of residual pesticides was developed using a gas chromatography. In this study, a simple and reliable methodology was improved to detect 175 kinds of residual pesticides by a liquid-liquid extraction procedure, followed by chromatographic analysis by gas chromatography. The 175 kinds of residual pesticides was classified into 4 groups according to the chemical structure, column type, resolution and sensitivity. The soybean sample selected for recovery experiment was not detected any pesticides. The recovery rates were ranged from 70.6% to 119.7% in most pesticides. The relative standard deviation (RSD 0.3~5.6%) was lower than 5.6% in all cases. The limits of detection (LOD) was lower than the maximum residue levels established by Korean legislations. The method has been successfully applied to the analysis of approximately 130 real samples.

Direct displacement-based seismic design methodology for the hybrid system of BRBFE and self-centering frame

  • Akbar Nikzad;Alireza Kiani;Seyed Alireza Kazerounian
    • Structural Engineering and Mechanics
    • /
    • v.88 no.5
    • /
    • pp.463-480
    • /
    • 2023
  • The buckling-restrained braced frames with eccentric configurations (BRBF-Es) exhibit stable cyclic behavior and possess a high energy absorption capacity. Additionally, they offer architectural advantages for incorporating openings, much like Eccentrically Braced Frames (EBFs). However, studies have indicated that significant residual drifts occur in this system when subjected to earthquakes at the Maximum Considered Earthquake (MCE) hazard level. Consequently, in order to mitigate these residual drifts, it is recommended to employ self-centering systems alongside the BRBF-E system. In our current research, we propose the utilization of the Direct Displacement-Based Seismic Design method to determine the design base shear for a hybrid system that combines BRBF with an eccentric configuration and a self-centering frame. Furthermore, we present a methodology for designing the individual components of this composite system. To assess the effectiveness of this design approach, we designed 3-, 6-, and 9-story buildings equipped with the BRBF-E-SCF system and developed finite element models. These models were subjected to two sets of ground motions representing the Maximum Considered Earthquake (MCE) and Design Basis Earthquake (DBE) seismic hazard levels. The results of our study reveal that although the combined system requires a higher amount of steel material compared to the BRBF-E system, it substantially reduces residual drift. Furthermore, the combined system demonstrates satisfactory performance in terms of story drift and ductility demand.

Pest Control and Analysis of Residual Pesticides of Mulberry Fruit and Leaf against Popcorn Disease by Cultivated Type and Region (오디 재배양식 및 지역에 따른 균핵병 방제 효과와 농약 잔류 특성)

  • Kim, Hyun Bok;Lee, Young Bo;Lim, Jung Dae;Lee, So Ra;Koo, Bon Woo;Kweon, Hae Yong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.28 no.6
    • /
    • pp.435-444
    • /
    • 2020
  • Background: As the Positive List System (PLS) is implemented in broad application to agricultural products, attention to the correct use of pesticides is also needed in the production of mulberry leaves and fruit. In this regard, three types of pesticides against mulberry popcorn disease were applied 2 - 3 times both in the field and greenhouses to prepare safety standards. Residual pesticide analysis was conducted on mulberry fruits and leaves. Methods and results: Three pesticieds, thiophanate-methyl, thiophanate-methyl·triflumizole and fluopyram registered as PLS pesticides for mulberry popcorn disease, were sprayed in the Wanju and in Buan regions, after which residual pesticide analysis was conducted using high-performance liquid chromatography (HPLC). As three pesticieds were either undetected or below the permissible level in mulberry fruit, demonstrating that they were suitable for safe spraying. However, 5.6 mg/kg of thiophanate-methyl was detected in the greenhouse after three application, which was slightly above maximum residue limit (MRL). Furthermore the level of thiophanate-methyl·triflumizole was higher than 0.2 mg/kg ("Gwasang No. 2" variety, spraying twice) or similar to 0.09 mg/kg ("Daesim" variety, spraying thrice) the permissible level (0.1T mg/kg) as the thiophanate-methyl was detected in mulberry leaves in the greenhouse. Conclusions: The spraying frequency for controlling mulberry popcorn disease in greenhouses should be limited to two times or less, especially when mulberry leaves are treated with thiophanate-methyl·triflumizole careful consideration is required if the leaves are to be used as food materials.

Seismic response of dual structures comprised by Buckling-Restrained Braces (BRB) and RC walls

  • Beiraghi, Hamid
    • Structural Engineering and Mechanics
    • /
    • v.72 no.4
    • /
    • pp.443-454
    • /
    • 2019
  • In order to reduce the residual drift of a structure in structural engineering field, a combined structural system (dual) consisting of steel buckling-restrained braced frame (BRBF) along with shear wall is proposed. In this paper, BRBFs are used with special reinforced concrete shear walls as combined systems. Some prototype models of the proposed combined systems as well as steel BRBF-only systems (without walls) are designed according to the code recommendations. Then, the nonlinear model of the systems is prepared using fiber elements for the reinforced concrete wall and appropriate elements for the BRBs. Seismic responses of the combined systems subjected to ground motions at maximum considered earthquake level are investigated and compared to those obtained from BRBFs. Results showed that the maximum residual inter-story drift from the combined systems is, on average, less than half of the corresponding value of the BRBFs. In this research, mean of absolute values of the maximum inter-story drift ratio demand obtained from combined systems is less than the 3% limitation, while this criterion has not been fulfilled by BRBF systems.