• 제목/요약/키워드: Maximum level

검색결과 4,908건 처리시간 0.03초

송전선로의 설비특성을 고려한 운영그룹 분류 및 최고허용온도 (An Operation Grouping and Its Maximum Allowable Conductor Temperature Considering Facility-conditions of Transmission Lines)

  • 손홍관;김병걸;박인표;안상현;장태인;최종기
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1922-1928
    • /
    • 2008
  • The thermal rating of a conductor are maximum continuous current capacity and short time emergency current capacity. The overload operation for a faults have an effect on a conductor lifetime. Its time duration and overload level are limited to facility conditions of transmission lines. The short time emergency current capacity in KOREA observe the KEPCO's DESIGN RULE 1210, but its rules are not included to concept of an allowable short time duration. This papers are described to the calculation concept of short time emergency current capacity considering a time duration and an overload level. And we suggested a operation grouping and its maximum conductor temperature considering facility conditions - conductor lifetime, stability of connection points, conductor height above ground and clearance, in the operating and new T/L.

Damage states of yielding and collapse for elevated water tanks supported on RC frame staging

  • Lakhade, Suraj O.;Kumar, Ratnesh;Jaiswal, mprakash R.
    • Structural Engineering and Mechanics
    • /
    • 제67권6호
    • /
    • pp.587-601
    • /
    • 2018
  • Elevated water tanks are inverted pendulum type structures where drift limit is an important criterion for seismic design and performance evaluation. Explicit drift criteria for elevated water tanks are not available in the literature. In this study, probabilistic approach is used to determine maximum drift limit for damage state of yielding and damage state of collapse for the elevated water tanks supported on RC frame staging. The two damage states are defined using results of incremental dynamic analysis wherein a total of 2160 nonlinear time history analyses are performed using twelve artificial spectrum compatible ground motions. Analytical fragility curves are developed using two-parameter lognormal distribution. The maximum allowable drifts corresponding to yield and collapse level requirements are estimated for different tank capacities. Finally, a single fragility curve is developed which provides maximum drift values for the different probability of damage. Further, for rational consideration of the uncertainties in design, three confidence levels are selected and corresponding drift limits for damage states of yielding and collapse are proposed. These values of maximum drift can be used in performance-based seismic design for a particular damage state depending on the level of confidence.

P-e 곡선의 타원특성을 고려한 전력계통의 최대 허용부하의 예측 (Estimation of Maximum Loadability in Power Systems By Using Elliptic Properties of P-e curve)

  • 김범식;문영현;권용준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.347-349
    • /
    • 2005
  • This paper presents an efficient algorithm to estimate the maximum load level for heavily loaded power systems with the load-generation variation vector obtained by ELD (Economic Load Dispatch) and/or short term load forecasting while utilizing the elliptic pattern of the P-e curve. It is well known the power flow equation in the rectangular coordinate is fully quadratic. However, the coupling between e and f makes it difficult to take advantage of this quadratic characteristic. In this paper, a simple technique is proposed to reflect the e-f coupling effects on the estimation of maximum loadability with theoretical analysis. An efficient estimation algorithm has been developed with the use of the elliptic properties of the P-e curve. The proposed algorithm is tested on IEEE 14 bus system, New England 39 bus system and IEEE 118 bus system, which shows that the maximum load level can be efficiently estimated with remarkable improvement in accuracy.

  • PDF

METHODS TO IMPROVE UTILIZATION OF RICE STRAW II. EFFECTS OF DIFFERENT LEVELS OF FEEDING ON INTAKE AND DIGESTIBILITY OF UNTREATED AND UREA AMMONIA TREATED RICE STRAW

  • Badurdeen, A.L.;Ibrahim, M.N.M.;Schiere, J.B.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제7권2호
    • /
    • pp.165-169
    • /
    • 1994
  • Forty cross bred ($168\;{\pm}\;28\;kg$) bull calves were offered either untreated (US) or urea ammonia treated (TS) rice straw at five levels of feeding, namely; 60, 80, 100, 120 140% of ad libitum. Ad libitum level for each animal was estimated over a period of one month, which was followed by a preliminary period of 21 days and a collection period of 15 days. The maximum organic matter intake (OMI-kg/100 kg BW) were 2.08 and 3.35 for US and TS, respectively and urea treatment increased the maximum OMI by 61% than for US. In order to reach maximum intake the amount feed refusal should be 25% for US, but with TS maximum intake was not reached even when the amount of feed refused was 39% of that consumed. The OMD of US significantly decreased with increase in OMI, whereas with TS the decrease was not significant. The inability of animals to select between stems and leaves particularly in TS might be one of the reasons for its constant digestibility. Considering the substantial increases in intake and the negative effect on digestibility of US, further trials are warranted, as well as studies to determine the practical implications.

Yield Response of Soybean to Drought Stress under Different Fertilizer Level

  • Eom, Ki-Cheol;Jung, Pil-Kyun;Koh, Mun-Hwan;Kim, Young-Sook;Lee, Kyung-Eun
    • 한국토양비료학회지
    • /
    • 제46권4호
    • /
    • pp.231-236
    • /
    • 2013
  • This study was conducted to investigate the yield response of soybean to drought stress in 1984 and 1986 at the experiment field of the National Academy of Agricultural Science using experiment plots with different soil water tension and fertilizer levels. The average yield response factor (YRF) of soybean to evapotranspiration (ET) calculated as [(Ya/Ym)/(ETa/ETm)], where Ya, average yield; Ym, maximum yield; ETa, average ET; and ETm, maximum ET, was 0.91 with the range from 0.74 to 1.16. Relationship between yield index (YI=[Ya/Ym]) and evapotranspiration index (ETI=[ETa/PET]) was $YI=0.87{\cdot}(ETI)+0.09$. Relationship between YI and the maximum soil water tension (Hmax) was $YI=1.23-0.23{\cdot}{\log}$ (Hmax). Relationship between YI and the days of drought stressed (Dr) was $YI=0.877{\cdot}{\exp}$ ($-0.01{\cdot}Dr$). The relation between YI and fertilizer level (F) was $YI=-0.21{\cdot}F2+0.36{\cdot}F+0.33$, under very serious drought condition as the maximum soil water tension was 0.3 MPa.

갑상선 수술 후 성대마비 환자의 기식 음성에 대한 공기역학적 및 음향적 분석 (An Aerodynamic and Acoustic Analysis of the Breathy Voice of Thyroidectomy Patients)

  • 강영애;윤규철;김재옥
    • 말소리와 음성과학
    • /
    • 제4권2호
    • /
    • pp.95-104
    • /
    • 2012
  • Thyroidectomy patients may have vocal paralysis or paresis, resulting in a breathy voice. The aim of this study was to investigate the aerodynamic and acoustic characteristics of a breathy voice in thyroidectomy patients. Thirty-five subjects who have vocal paralysis after thyroidectomy participated in this study. According to perceptual judgements by three speech pathologists and one phonetic scholar, subjects were divided into two groups: breathy voice group (n = 21) and non-breathy voice group (n = 14). Aerodynamic analysis was conducted by three tasks (Voicing Efficiency, Maximum Sustained Phonation, Vital Capacity) and acoustic analysis was measured during Maximum Sustained Phonation task. The breathy voice group had significantly higher subglottal pressure and more pathological voice characteristics than the non breathy voice group. Showing 94.1% classification accuracy in result logistic regression of aerodynamic analysis, the predictor parameters for breathiness were maximum sound pressure level, sound pressure level range, phonation time of Maximum Sustained Phonation task and Pitch range, peak air pressure, and mean peak air pressure of Voicing Efficiency task. Classification accuracy of acoustic logistic regression was 88.6%, and five frequency perturbation parameters were shown as predictors. Vocal paralysis creates air turbulence at the glottis. It fluctuates frequency-related parameters and increases aspiration in high frequency areas. These changes determine perceptual breathiness.

최대 도플러 주파수 추정 시 대역 조절을 통한 부가 잡음의 영향 완화 기법 (SNR-independent Methods for Estimating Maximum Doppler Frequency)

  • 유현규;박구현;오성목;강창언;홍대식
    • 한국통신학회논문지
    • /
    • 제30권6C호
    • /
    • pp.475-480
    • /
    • 2005
  • 이동 통신 시스템에서 최대 도플러 주파수 정보는 여러 가지 채널 적응 기술들과 무선 자원 관리 방법들의 무선 채널에 대한 최적화를 가능하게 한다. 본 논문에서는 레벨 교차율(LCR: level crossing rate) 및 공분산 함수(COV: covariance)에 기반을 둔 두 가지 최대 도플러 주파수 추정 기법을 제안한다. 부가 잡음의 영향을 제거하기 위해 신호 대 잡음비(SNR)에 독립적인 성능을 위한 조건을 분석하고, 제시한 조건을 만족시키기 위하여 하향 표본화 (downsampling) 방법을 이용한 도플러 주파수 추정 알고리즘을 새로이 제안하다. 모의실험을 통해, 제안된 기법이 SNR 변화에 상관없이 좋은 성능을 나타냄을 확인할 수 있다.

두 개의 최대 주기를 갖는 셀룰라 오토마타 수열을 이용한 영상 암호화 (Image Encryption using Cellular Automata Sequence with Two Maximum Cycle)

  • 남태희;조성진;김석태
    • 한국정보통신학회논문지
    • /
    • 제14권5호
    • /
    • pp.1201-1208
    • /
    • 2010
  • 본 논문에서는 두 개의 선형 MLCA(Maximum Length Cellular Automata)을 이용한 영상 암호화 방법을 제안한다. 암호화 방법은 먼저 8 비트 초기 값을 임의로 설정한다. 그 다음, 설정된 초기 값을 이용하여 행과 열을 단계적으로 변화시켜 고품질의 PN(pseudo noise) 수열을 생성한다. 생성된 수열을 이용하여 기저영상을 생성한다. 마지막으로 기저영상을 원 영상과 XOR 연산함으로서 암호화 수준이 높은 결과 영상을 얻는다. 히스토그램 및 안정성 분석을 통하여 제안한 방법이 높은 암호화 수준의 성질을 가졌음을 검증한다.

콤바인 예취장치의 절단특성에 관한 연구(II) -2배형, 2중형 칼날의 절단특성- (Cutting-Pattern and Cutting Characteristics of the Reciprocating Cutter-bar of Combine Harvester(II)- Cutting Characteristics of the Low-Cutting Type and Double Cutting Type Reciprocating Knives-)

  • 이홍주;김홍윤;홍종호;이성범
    • Journal of Biosystems Engineering
    • /
    • 제20권1호
    • /
    • pp.13-21
    • /
    • 1995
  • This study was conducted to investigate the cutting mechanism of reciprocating knife of combine harvester. The cutting operation of reciprocating knife with the arrangement of the low-cutting and the double-cutting was demonstrated through cutting pattern diagram which was drawn by computer graphics. Various kinds and dimensions of reciprocating knives were analyzed using the developed program. The results are summarized as follows (1) The low-cutting type reciprocating knife was represented similar cutting characteristics to the standard type, but the maximum stalk-deflection was decreased as 1/2 level of the standard type. And the first ledger plate should be designed shorter than the second ledger plate. (2) The bunching area and the maximum stalk-deflection for the double cutting knife almost were not changed since cutting velocity ratio of 0.6, but the secondary cut were occurred at ratio of 0.8 and increased rapidly over these ratio. (3) The double cutting knife was recommended for the high speed combine, because its bunching area and the maximum stalk-deflection were decreased as 1/2 level of the standard type. (4) In order to maintain the proper cutting mechanism characterized by the bunching area, the maximum stalk-deflection and the secondary cutting length etc., the adequate cutting velocity at forward speed of 0.5㎧ to 1.2㎧ was from 0.3㎧ to 0.96㎧ for the double cutting knives.

  • PDF

Survey of the heterogeneous gene expression in olive flounder muscle using the luciferase reporter gene system

  • Hong, Suhee;Lee, Sang-Jun
    • 한국어병학회지
    • /
    • 제16권3호
    • /
    • pp.147-152
    • /
    • 2003
  • The CMV promoter driven luciferase reporter gene coding plasmid (pcDNA-luc) was constructed and used as a model for DNA immunization study. Expression of the recombinant luciferase protein was confirmed in vitro in RTG-2 cell line before using in vivo study in olive flounder. In dose response study, the maximum expression of the luciferase gene was found in the group injected with 10-15μg of plasmid DNA. The kinetic study showed that the luciferase gene expression was reached at the maximum level at one day after injection and slightly decreased after then but significantly high level of expression was sustained until the conducted experiment of 7 days. In the study of tissue distribution of gene expression, it was found that luciferase gene was expressed at the significant level in immune organs such as gill and spleen, located far from the injected site, suggesting the systemic distribution of the intramuscularly injected DNA in olive flounder.