• 제목/요약/키워드: Maximum individual dose

검색결과 34건 처리시간 0.021초

Isothermal and Kinetic Studies of the Adsorption Removal of Pb(II), Cu(II), and Ni(II) Ions from Aqueous Solutions using Modified Chara Sp. Algae

  • Kalash, Khairi R.;Alalwan, Hayder A.;Al-Furaiji, Mustafa H.;Alminshid, Alaa. H.;Waisi, Basma I.
    • Korean Chemical Engineering Research
    • /
    • 제58권2호
    • /
    • pp.301-306
    • /
    • 2020
  • We investigated the individual biosorption removal of lead, copper, and nickel ions from aqueous solutions using Chara sp. algae powder in a batch mode. The impact of several parameters, such as initial concentration of the metal ions, contacting time, sorbent dose, and pH on the removal efficiency, was investigated. The maximum removal efficiency at optimum conditions was found to be 98% for Pb(II) at pH = 4, 90% for Cu(II) at pH = 5, and 80% for Ni(II) at pH = 5. The isotherm study was done under the optimum conditions for each metal by applying the experimental results onto the well-known Freundlich and Langmuir models. The results show that the Langmuir is better in describing the isotherm adsorption of Pb(II) and Ni(II), while the Freundlich is a better fit in the case of Cu(II). Similarly, a kinetic study was performed by using the pseudo-first and second-order equations. Our results show that the pseudo-second-order is better in representing the kinetic adsorption of the three metal ions.

Evaluating Methods of Vibration Exposure and Ride Comfort in Car

  • Park, Se Jin;Subramaniyam, Murali
    • 대한인간공학회지
    • /
    • 제32권4호
    • /
    • pp.381-387
    • /
    • 2013
  • Objective: This paper studies the method of measuring whole-body vibration in the car and terms associated. Background: Human exposure to vibration can be broadly classified as localized and whole-body vibration. The whole-body vibration affects the entire body of the exposed person. It is mainly transmitted through the seat surfaces, backrests, and through the floor to an individual sitting in the vehicle. It can affect the comfort, performance, and health of individuals. Method: Human responses to whole-body vibration can be evaluated by two main standards such as ISO 2631 and BS 6841. The vibration is measured at 8 axes - three translations at feet, 3 translations of hip and two translations of back proposed by Griffin. B&K's sensors used in this study are the 3-axes translational acceleration sensor to measure the translational accelerations at the hip, back and foot. Results: The parameters associated with the whole-body vibration in the car are frequency weightings, frequency weighted root-mean-square, vibration dose values, maximum transient vibration value, seat effective amplitude transmissibility, ride values and ride comfort. Conclusion: Studied the evaluating methods of vibration exposure and ride comfort. Application: Evaluation of whole-body vibration in the car.

Effect of Flutriafol Exposure on Residue Characteristics in Pig Muscle and Fat Tissue

  • Jeong, Jin Young;Kim, Byeonghyeon;Ji, Sang Yun;Baek, Youl Chang;Kim, Minji;Park, Seol Hwa;Jung, Hyunjung
    • 한국축산식품학회지
    • /
    • 제42권1호
    • /
    • pp.186-196
    • /
    • 2022
  • This study investigated the effect of exposure to flutriafol based on residues in pigs. Pigs were exposed to different concentrations (0.313, 0.625, 3.125, 6.25, and 12.5 mg/kg bw/d, n=20) for 4 wk in different treatment groups. Serum biochemical analysis, residue levels, and histological analysis were conducted using the VetTest chemistry analyzer, liquid chromatography mass spectrometry, and Masson's trichrome staining, respectively. The body weight (initial and final) was not significantly different between groups. Parameters such as creatinine, blood urea nitrogen, alanine aminotransferase, and lipase levels were significantly different as compared to the control group. Flutriafol increased the residue limits in individual tissue of the pigs in a dose dependent manner. Flutriafol exposures indicated the presence of fibrosis, as confirmed from Masson's trichrome staining. These results suggest that flutriafol affects the morphology and serum levels in pigs. The dietary flutriafol levels can provide a basis for maximum residue limits and food safety for pork and related products.

뇌정위적 방사선수술 시 콜리메이터 크기 변화에 따른 검출기 의존성 평가 (Evaluation of Detector Dependency on Collimator in SRS: Compared Detectors; CC01, CC13, SFD)

  • 배용기;방동완;박병문;강민영;김연래
    • 대한방사선치료학회지
    • /
    • 제20권2호
    • /
    • pp.109-113
    • /
    • 2008
  • 목 적: 뇌정위적 방사선수술시 이용되는 콜리메이터의 크기 변화에 따른 검출기 의존성을 평가하고자 한다. 대상 및 방법: 본 실험을 위해 6 MV 광자선(CL21EX, Varian, Palo Alto), 이온전리함(CC01, CC13, Wellhofer, Germany), 정위적 다이오드검출기(SFD, Wellhofer, Germany)를 사용하였다. 심부선량백분율(PDD)의 검출기 의존성을 평가하기 위해 Brain Lab사의 콜리메이터(${\varphi}$5, 10, 20, 30 mm)와 $10{\times}10\;cm^2$에서 측정, 비교하였다. 선량측면도(dose profile)는 SAD 100 cm에서 콜리메이터(${\varphi}$10, 30 mm)와 $10{\times}10\;cm^2$를 측정하여 반치폭(FWHM; full width half maximum)과 반음영(20∼80%)을 비교하였다. 선량출력인자의 측정을 위해 선량최대깊이에서 콜리메이터(${\varphi}$5, 10, 20, 30 mm)의 출력을 측정하였으며, 정방형 조사면($10{\times}10\;cm^2$)의 출력 값을 기준으로 정규화 하였다. 결 과: 검출기에 따른 PDD의 영향을 평가하기 위해 PDD20,10 (PDD20/PDD10)을 비교하였다. 콜리메이터 ${\varphi}$5 mm에서는 SFD 51.3%, CC01 50%, CC13 58%로 측정되었고, 다른 콜리메이터에서는 최대 1%의 측정값 차이를 보였다. 선량측면도 평가에서 FWHM은 0.1∼0.4 mm의 차이를 보였다. 반음영은 ${\varphi}$10 mm에서 SFD 3.2 mm, CC01 7.1 mm, CC13 9.4 mm로 측정되었고, ${\varphi}$30 mm에서 SFD 4 mm, CC01 6.7 mm, CC13 12.4 mm로 측정되었다. $10{\times}10\;cm^2$에서는 SFD 6.6 mm, CC01 8.6 mm, CC13 12.2 mm로 측정되었다. 선량출력인자는 ${\varphi}$20 mm 이상에서 검출기별 최대 2%의 차이를 보였다. ${\varphi}$5 mm에서는 SFD 85%, CC01 61%, CC13 24%로 측정되었고, ${\varphi}$10 mm에서는 SFD 94%, CC01 85%, CC13 71%로 측정되었다. 실험결과 PDD는 CC13이 조사면에 충분히 포함되지 않은 ${\varphi}$5 mm에서 최대 16%의 차이를 보였고, 선량측면도의 FWHM은 검출기별 최대 0.4 mm의 차이를 보였다. 선량측면도의 반음영은 ${\varphi}$30 mm에서 최대 8.4 mm 차이를 보였고, 출력선량인자는 ${\varphi}$5 mm에서 최대 72%의 차이를 나타냈다. 결 론: 뇌정위적 방사선수술을 시행하는데 있어 정확한 선량을 측정할 수 있는 검출기를 선택하는 것은 무엇보다 중요하다. 따라서 본 실험에서는 측정을 통한 작은 원형조사면 선량계측에서 정위적 다이오드 검출기가 이온전리함에 비해 선량의 특성을 평가하는데 있어 유용함을 알 수 있었다.

  • PDF

6MV X선에 있어서 쇄기형 조사야와 개방 조사야 사이의 깊이 선량률의 차이 (Variation in Depth Dose Data between Open and Wedge Fields for 6 MV X-Rays)

  • 우홍;류삼열;박인규
    • Radiation Oncology Journal
    • /
    • 제7권2호
    • /
    • pp.279-285
    • /
    • 1989
  • Tatcher식에 의하여 조직최대선량비와 깊이선량을 6MV X-선의 중심축상에서 측정하였다. 쐐기형 조사야에 있어서 깊이, 조사야 및 쐐기의 두께 등이 증가할수록 깊이선량은 개방 조사야에 비하여 크기가 증가하였다. 그러나 쐐기형 조사야에 있어서 조직산란보정 계수는 개방 조사야에 비하여 그 차이가 $1\%$ 미만이었다. 두 조사야에 있어서 중심축상의 깊이선량백분률의 차이가 발생하는 것은 쐐기에 의해서 X-선이 강화됨을 의미한다. 같은 각도의 쇄기에서 깊이선량백분률과 산란보정계수의 명목쐐기형 조사야와 유효쐐기형 조사야사이의 차이는 없었다. 개방조사야에서 조사야 $6cm{\times}6cm$, 깊이 7cm의 깊이선량백분률은 명목 또는 유효쐐기형 조사야 보다 $3.26\%$가 더 컸다. 그러나 조사야 $(10cm{\times}10cm)$가 커질수록 깊이선량백분률의 차이는 명목 또는 유효쐐기형 조사야보다 더 증가하였다-선량계측차이는 깊이 7cm에서 $3.56\%$, 12cm에서는 $5.30\%$였다 그러므로 심부종양치료시 선량의 계산이나 모니터세팅은 각 쐐기의 깊이 백분선량률과 투과율을 사용하여야 오차를 줄일 수 있을 것으로 사료된다.

  • PDF

Influence of EDZ on the Safety of a Potential HLW Repository

  • 황용수;강철형
    • 방사성폐기물학회지
    • /
    • 제2권4호
    • /
    • pp.253-262
    • /
    • 2004
  • Construction of tunnels in a deep crystalline host rock for a potential High-Level Radioactive Waste(HLW) repository inevitably generates an excavation disturbed zone (EDZ). There have been a series of debates on whether a permeability in an EDZ increases or not and what would be the maximum depth of an EDZ. Recent studies show mixed opinions on permeability. However, there has been an international consensus on the thickness of an EDZ; 30 cm for TBM and 1 meter for controlled blast. One of the impacts of an EDZ is on determining the distance between adjacent deposition holes. The void gap by the excavation hinders relaxation of temperature profiles so that the current Korean reference designing distance between holes should be stretched out more to keep the maximum temperature in a buffer region below 100 degrees Celsius. The other impact of an EDZ is on the long-term post closure radiological safety. To estimate the impact, the reference scenario, the well scenario, is chosen. Released nuclides diffuse through a bentonite buffer region experiencing strong sorption and reach a fracture surrounded by a porous medium. Inside a fractured porous region, radionuclides migrate by advection and dispersion with matrix diffusion into a porous medium. Finally, they reach a well assumed to be a source of potable water for local residents. The annual individual dose is assessed on this well scenario to find out the significance of an EDZ. A profound sensitivity study was performed, but all results show that the impact is negligible. Even though the role of an EDZ turns out to be limited on overall safety assessment, still it is worthwhile to study the chemical role of an EDZ, such as a potential source for natural colloids, potential sealing of an open fracture by fine clay particles generated by the process of an EDZ, and alteration of a sorption mechanism by an EDZ in the future.

  • PDF

감마선 조사에 의한 뇌조직의 Jun 및 p53유전자 발현 (Expression of Jun and p53 Genes from the Brain of Rats Irradiated with $^{60}Co{\gamma}$-ray)

  • 김용석;우종규;이용성;고재경;전하정;이명자
    • Radiation Oncology Journal
    • /
    • 제14권4호
    • /
    • pp.265-279
    • /
    • 1996
  • 방사선은 DNA손상을 초래하고 세포 성장에 관련된 유전자의 발현 조절 및 apoptosis등을 유발한다고 알려져 있으며 본 연구는 신경계에 있어 방사선 조사 후 종양 발생율과 시간 경과의 관계 및 조사 양과 암 발생의 관계를 구명하기 위해 코발트 60의 전신조사에 따른 흰쥐 뇌 조직의 생체 반응을 연구하고자 하였다. 이를 위하여 상기조직의 jun 및 p53 유전자의 발현도를 1 Gy로 부터 100 Gy 범위의 감마선 용량별 및 1시간에서 6시간까지의 조사 훈 경과 시간 별로 Northern 분석하였다. Jun유전자 발현도는 ley이하에서 1시간 이내에 한계수준에 도달하였으며 30 Gy의 조사 1시간 째에 최대였다. 또한 조사 1시간 이후 1 Gy로부터 10 Gy 범위에서는 조사 5시간 및 6시간까지 점진적으로 증가되었으나 20 Gy로부터 100 Gy 범위에서는 조사 2시간까지 증가 후 감소되는 양상을 나타냈다. p53유전자의 발현도는 1 Gy이하에서 1시간 이내에 한계 수준에 근접했고 1 Gy의 조사 후 6시간 째에 최대였다. 1 Gy로부터 40 Gy까지의 범위에서는 조사 5시간 및 6시간까지 점진적으로 증가되는 반면 50 Gy에서 100 Gy범위에서는 조사 2시간 째까지 증가 후 감소되는 양상을 보였다. 따라서 감마선 조사양이 높을수록 jun 및 p53유전자는 신속하게 최대로 발현되었고 감마선 조사양이 낮을수록 서서히 증가되었다 그러나 jun유전자와 p53유전자의 감마선 조사에 따른 발현 양상에는 상호간의 연관성을 찾을 수 없었다.

  • PDF

선형가속기 ML-15MDX의 각 Applicator에 대한 전자선 출력선량 계수 결정 (Determination of Electron Beam Output Factors of Individual Applicator for ML-15MDX Linear Accelerator)

  • Park, Tae-Jin;Kim, Ok-Bae
    • 한국의학물리학회지:의학물리
    • /
    • 제5권1호
    • /
    • pp.87-99
    • /
    • 1994
  • 목적 : 선형가속기 ML-15MDX의 전자선에너지 대한 출력선량계수가 Applicator크기에 따라 결정되도록 하며 각 Applicator에서 정방형조사면과 직사각형조사변에 대한 출력선량계수는 측정값으로 부터 다항식을 이용하여 결정되었다. 방법 : 실험에서, 출력선량의 측정은 전자선에너지 4, 6, 9, l2MEV대해 2$\times$2$cm^2$에서 20$\times$20$cm^2$까지 이루어졌다. 출력선량계수는 각 아프리케이터의 조사면중심선속의 최대선량에 대한 임의 조사면의 최대선량의 비로 얻어졌고 각 아프리케이터의 출력선량계수는 기준 아프리케이터(10$\times$10$cm^2$)와 비교되었다. 전자선조사면의 차폐는 모든 실험에너지 영역에서 균등하게 10mm 두께의 Lipowitz(밀도 9.4g/$cm^2$)를 사용하였으며, 조사면크기 및 모양 결정이 용이하도록 고안하여 사용되었다. 임의의 전자선조사면에 대한 출력선량계수는 조사면의 한변을 고정한 직사각형의 출력선량 계수를 이용한 1-Dimension방법에 의한 다항식으로 부터 구하였다. 결과 : 직사각형의 전자선조사면에 대한 출력선량계수는 4$\times$4$cm^2$에서 20$\times$20$cm^2$의 범위에서는 2%이내의 불확실성을 보였으며, 이들 보다 작은 직사각형조사면에서는 약 3%의 오차를 보였다. 결론 : 전자선에너지의 정사각형 및 직사각형조사변에 대한 출력선량계수가 실험자료를 이용한 다항식으로 부터 실제값에 매우 근사한 예상값을 얻을 수 있었다.

  • PDF

폐밀봉선원 처분방식별 폐쇄후 예비안전성평가 (Preliminary Post-closure Safety Assessment of Disposal Options for Disused Sealed Radioactive Source)

  • 이승희;김주열;김석훈
    • 자원환경지질
    • /
    • 제49권4호
    • /
    • pp.301-314
    • /
    • 2016
  • 국내에서 발생한 폐밀봉선원은 현재 한국원자력환경공단 폐기시설에 임시 보관 중에 있으며 향후 중 저준위 방사성 폐기물 처분시설에 처분될 예정이다. 본 연구에서는 폐밀봉선원의 최적 처분방안 수립에 앞서 폐밀봉선원 처분시 폐쇄후 예비안전성평가를 수행하였다. 폐밀봉선원이 표층처분시설 또는 동굴처분시설에 처분되는 것으로 가정하였으며, GoldSim 전산코드를 사용하여 결정집단의 개인 피폭선량을 계산하였다. 평가결과 정상 시나리오시 최대 피폭선량은 두 가지 처분방식에 대해 약 $1{\times}10^{-7}mSv/yr$으로 나타났으며 이는 규제치인 0.1 mSv/yr에 대비하여 장기적으로 충분한 안전성을 확보할 수 있는 것으로 판단된다. 우물시나리오 시 최대 피폭선량은 표층처분시설에서 규제치인 1 mSv/yr를 초과하였으며 이는 $^{226}Ra$, $^{210}Pb$($^{226}Ra$의 딸핵종) 및 $^{237}Np$($^{241}Am$의 딸핵종)에 기인한 것으로 확인되었다. 동굴처분시설의 경우, 모든 핵종의 최대 피폭선량이 법적 규제치를 만족하나 $^{14}C$$^{237}Np$($^{241}Am$의 딸핵종)에 의한 피폭선량이 규제치 대비 10%를 초과하는 상대적으로 높은 값을 나타내는 것으로 확인되었다. 처분시설 폐쇄후 주민의 피폭선량은 반드시 법적 규제치 이하로 유지되어야 하므로 규제치를 초과 또는 이에 근접한 피폭선량을 유발하는 핵종인 $^{14}C$, $^{226}Ra$$^{241}Am$를 각 처분방식에서 제한할 필요가 있으며 안전한 영구 처분을 위한 처분전 관리가 요구된다.

Breast Radiotherapy with Mixed Energy Photons; a Model for Optimal Beam Weighting

  • Birgani, Mohammadjavad Tahmasebi;Fatahiasl, Jafar;Hosseini, Seyed Mohammad;Bagheri, Ali;Behrooz, Mohammad Ali;Zabiehzadeh, Mansour;meskani, Reza;Gomari, Maryam Talaei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권17호
    • /
    • pp.7785-7788
    • /
    • 2015
  • Utilization of high energy photons (>10MV) with an optimal weight using a mixed energy technique is a practical way to generate a homogenous dose distribution while maintaining adequate target coverage in intact breast radiotherapy. This study represents a model for estimation of this optimal weight for day to day clinical usage. For this purpose, treatment planning computed tomography scans of thirty-three consecutive early stage breast cancer patients following breast conservation surgery were analyzed. After delineation of the breast clinical target volume (CTV) and placing opposed wedge paired isocenteric tangential portals, dosimeteric calculations were conducted and dose volume histograms (DVHs) were generated, first with pure 6MV photons and then these calculations were repeated ten times with incorporating 18MV photons (ten percent increase in weight per step) in each individual patient. For each calculation two indexes including maximum dose in the breast CTV ($D_{max}$) and the volume of CTV which covered with 95% Isodose line ($V_{CTV,95%IDL}$) were measured according to the DVH data and then normalized values were plotted in a graph. The optimal weight of 18MV photons was defined as the intersection point of $D_{max}$ and $V_{CTV,95%IDL}$ graphs. For creating a model to predict this optimal weight multiple linear regression analysis was used based on some of the breast and tangential field parameters. The best fitting model for prediction of 18MV photons optimal weight in breast radiotherapy using mixed energy technique, incorporated chest wall separation plus central lung distance (Adjusted R2=0.776). In conclusion, this study represents a model for the estimation of optimal beam weighting in breast radiotherapy using mixed photon energy technique for routine day to day clinical usage.