• Title/Summary/Keyword: Maximum finger force

Search Result 21, Processing Time 0.031 seconds

Research of Grip Forces and Subjective Preferences for Various Individual Finger Grip Spans by using an (MFFM System을 이용한 손가락 별 파지 폭들의 변화에 따른 악력 및 개인 선호도에 대한 연구)

  • Kim, Dae-Min;Kong, Yong-Ku
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.3
    • /
    • pp.1-6
    • /
    • 2008
  • Individual finger/total grip forces, and subjective preferences for various individual finger grip spans (i.e., four fingers had identical grip spans or different grip spans) were evaluated by using an "Adjustable Multi-Finger Force Measurement (MFFM) System". In this study, three grip spans were defined as follows: a 'favorite grip span' which is the span with the highest subjective preference; a 'maximum grip span' which is the span with the highest total grip force; a 'maximum finger grip span' which is a set of four grip spans that had maximum finger grip forces associated with the index, middle, ring, and little fingers, respectively. Ten males were recruited from university population for this study. In experiment I, each participant tested the maximum grip force with five grip spans (45 to 65mm) to investigate grip forces and subjective preferences for three types of grip spans. Results showed that subjective preferences for grip spans were not coincidence with the performance of total grip forces. It was noted that the 'favorite grip span' represented the lowest total grip force, whereas the 'maximum finger grip span' showed the lowest subjective preferences. The individual finger forces and the average percentage contribution to the total finger force were also investigated in this study. The findings of this study might be valuable information for designing ergonomics hand-tools to reduce finger/hand stress as well as to improve tool users' preferences and performance.

Optimal Grip Span of A-type Pliers in a Maximum Gripping Task

  • Kong, Yong-Ku;Jung, Jin Woo;Kim, Sangmin;Jung, Heewoong;Yoo, Hakje;Kim, Dae-Min;Kang, Hyun-Sung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.6
    • /
    • pp.511-516
    • /
    • 2013
  • Objective: The objective of this study is designing an optimal hand tool through maximum grip force study accordance to the hand grip span. Background: In order to prevent musculoskeletal diseases, studies on hand tool design are proceeding based on grip strength, finger force, and contribution of individual finger force on total grip strength. However, experimental apparatus using a tool that is actually used in work place was almost non-existent. Method: 19 males were participated in an experiment. Using the load cell inserted real plier, finger force, grip strength, and subjective discomfort rate of both hands (dominant and non-dominant) were measured in 5 different hand grip span(45mm, 50mm, 60mm, 70mm, and 80mm). Results: There was significant difference(p<0.001) of total grip strength, individual finger force and subjective discomfort rating according to various hand grip span(45, 50, 60, 70, and 80mm). Also, statistically significant different(p<0.001) was shown between the dominant hand and non-dominant hand. In addition, individual finger force in maximum grip was in order of middle finger, ring finger, index finger, and little finger. Conclusion: Optimal grip span of pliers that exerting maximum grip strength is 50~60mm. Application: This finding is expected to be used for designing proper pliers.

Evaluation of Individual Finger Force to Grip Strength in Various Grip Spans and Hand Sizes (파지 폭과 손 크기에 따른 각 손가락이 총 악력에 미치는 영향 분석)

  • Jung, Myung-Chul;Kim, Dae-Min;Kong, Yong-Ku
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.59-65
    • /
    • 2007
  • In this study, six grip spans (45mm-65mm) were tested to evaluate the effects of handle grip span and user's hand size on maximum grip strength, individual finger force, and subjective ratings of comfort using a digital dynamometer with individual force sensors. Forty-six males were assigned into three hand size groups according to their hand lengths. Results showed that overall 55mm and 50mm grip spans were the most comfortable sizes and associated with the highest grip strength in the maximum grip force exertions, whereas 65mm grip span was rated as the least comfortable size as well as the lowest grip strength. In the interaction effect of grip span and hand size, small and middle hand sized participants rated the best preference and the least preference grip spans differently with large hand sized participants. With respect to the analysis of individual finger force, the middle finger force was the strongest and the highest contribution to the total finger force, followed by ring, index and little fingers. In addition, it was noted that each finger had a different optimal grip span for exerting maximum force resulting in a bowed contoured shaped handle for two-handle hand tools. Thus, the grip spans for two-handle hand tools might be designed according to the users' hand and finger anthropometrics to maximize performance and subjective perception of comfort.

A Novel Nonmechanical Finger Rehabilitation System Based on Magnetic Force Control

  • Baek, In-Chul;Kim, Min Su;Kim, Sung Hoon
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.155-161
    • /
    • 2017
  • This paper presents a new nonmechanical rehabilitation system driven by magnetic force. Typically, finger rehabilitation mechanisms are complex mechanical systems. The proposed method allows wireless operation, a simple configuration, and easy installation on the hand for active actuation by magnetic force. The system consists of a driving coil, driving magnets (M1), and auxiliary magnets (M2 and M3), respectively, at the finger, palm, and the center of coil. The magnets and the driving coil produce three magnetic forces for an active motions of the finger. During active actuations, magnetic attractive forces between M1 and M2 or between M1 and M3 enhance the flexion/extension motions. The proposed system simply improves the extension motion of the finger using a magnetic system. In this system, the maximum force and angular variation of the extension motion were 0.438 N and $49^{\circ}$, respectively. We analyzed the magnetic interaction in the system and verified finger's active actuation.

The Effect of Frequency of Transcutaneous Electrical Nerve Stimulation (TENS) on Maximum Multi-finger Force Production

  • Karol, Sohit;Koh, Kyung;Kwon, Hyun Joon;Park, Yang Sun;Kwon, Young Ha;Shim, Jae Kun
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.1
    • /
    • pp.93-99
    • /
    • 2016
  • Objective: The purpose of this study was to investigate the effect of transcutaneous electrical nerve stimulation (TENS) treatment on maximum voluntary force (MVF) production. Methods: Ten healthy, young subjects (5 males and 5 females) participated in the study. MVF was recorded after a fifteen minute session of TENS stimulation under two conditions: low frequency (4 Hz) at maximum tolerable level and high frequency (110 Hz) at maximum tolerable level. TENS was provided simultaneously via self-adhesive electrodes placed on the finger pads of the index, middle, ring and little fingers. MVF was also recorded in a baseline condition with no TENS treatment. Data were collected in three different sessions on three consecutive days at the sametime of the day. Results: Results from the study show that on an average, MVF increasesby 25% for the index, middle and little fingers for TENS treatment with 4 Hz frequency as compared to the baseline condition. However, the 110 Hz condition did not result in a significantly different MVF than the baseline condition during individual finger pressing tasks. In addition, while producing MVF with all the four finger stogether, MVF was 30% higher for the 4 Hz conditionin comparison to the baseline condition, and 15% higher for the 110 Hz condition in comparison to the baseline condition respectively. Conclusion: The results suggest that stimulation ofafferent fibers onthe glabrous skinwith TENS could have a net facilitatory effect on the maximum motoroutput.

Analysis of Maximum Acceptable Frequencies for Upper Extremity Motions with Forces in a Seated Position (앉은 자세에서 힘 수준에 따른 상지관절 동작별 최대 수용 반복 빈도수 분석)

  • Kwon, O-Chae;You, Hee-Cheon;Jung, Ki-Hyo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.65-70
    • /
    • 2005
  • Evaluation of repetitiveness for upper extremity intensive tasks is essential to determine the level of risk for upper extremity musculoskeletal disorders at the workplace. However, experimental data available to establish the acceptable levels of repetitiveness for various postures and forces is lacking. The present study examined the maximum acceptable frequencies(MAFs; motions/min.) of shoulder, elbow, wrist, and index finger motions at different forces(1kgf and 4kgf for shoulder, elbow, and wrist; 0.25kgf and 1 kgf for index finger) in sitting. Seventeen right-handed males in 20s without having any history musculoskeletal disorders participated in the MAF experiment. The participants determined their MAFs for the upper extremity motions by using the self-adjustment method and their work pulse(increase in heart rate; beats/min.) and rating of perceived exertion(RPE) were measured when working at MAF. The MAFs of elbow, wrist, and index finger motions for each force level were about 2, 3, and 6 times the corresponding MAF(9 at the high force and 24 at the low force) of shoulder motion and the MAFs at the low force increased about 2 times those at the high force. The work pulses of elbow, wrist, and index finger motions for each force level were 70%, 50%, and 30% of the corresponding work pulse(17 at the high force and 12 at the low force) of shoulder motion and the work pulses at the low force were about 70 % of those at the high force. Lastly, the RPEs of the upper extremity regions were about level 3(moderate) or below.

Evaluation of Gender Effect in Various Pliers' Grip Spans for Maximum Isometric Grasping Tasks

  • Kong, Yong-Ku;Kim, Dae-Min;Park, Ji-Soo;Lee, Sung-Yong;Choi, Kyeong-Hee;Kim, Kyung Ran
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.6
    • /
    • pp.553-563
    • /
    • 2014
  • Objective: The purpose of this study was to evaluate the effect of gender (male, female) and grip spans (45, 50, 60, 70, 80mm) on total grip strength, resultant force, finger force and subjective discomfort rating. Background: In order to prevent musculoskeletal disorders, studies of hand tools need to be preceded based on grip strength, finger force, and subjective discomfort rating. However, experimental apparatus using tools such as pliers that reflect the actual work place was almost non-existent. Method: Fifty-Two (26 males and 26 females) participants were recruited from the student population. In this study, a pair of revised pliers, which can change grip span from 45 to 80mm was applied to estimate total grip strength, resultant force and individual finger forces. All participants were asked to exert a maximum grip force with three repetitions, and to report the subjective discomfort rating for five grip spans of pliers (45, 50, 60, 70, 80mm). Results: There were significant differences of total grip strength, resultant force, individual finger forces and subjective discomfort rating according to grip span. The lowest total grip strength was obtained from the grip span of 80mm for both genders. For resultant force, the highest resultant force was exerted at grip spans of 50, 60 and 70mm for females and 50 and 60mm for males. The lowest subjective discomfort rating was observed in the 50mm for both genders. Conclusion: Based on the result, 50mm and 60mm grip spans which provide the highest force and lowest discomfort rating might be recommendable for the male and female pliers users. Application: The findings of this study can provide guidelines on designing a hand tool to help to reduce hand-related musculoskeletal disorders and obtain better performance.

Evaluation of the Contributions of Individual Finger Forces in Various Submaximal Grip Force Exertion Levels

  • Kong, Yong-Ku;Lee, Inseok;Lee, Juhee;Lee, Kyungsuk;Choi, Kyeong-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.5
    • /
    • pp.361-370
    • /
    • 2016
  • Objective:The aim of this study is to evaluate contributions of individual finger forces associated with various levels of submaximal voluntary contraction tasks. Background: Although many researches for individual finger force have been conducted, most of the studies mainly focus on the maximal voluntary contraction. However, Information concerning individual finger forces during submaximal voluntary contraction is also very important for developing biomechanical models and for designing hand tools, work equipment, hand prostheses and robotic hands. Due to these reasons, studies on the contribution of individual finger force in submaximal grip force exertions should be fully considered. Method: A total of 60 healthy adults without any musculoskeletal disorders in the upper arms participated in this study. The young group (mean: 23.7 yrs) consisted of 30 healthy adults (15 males and 15 females), and the elderly group (mean: 75.2 yrs) was also composed of 30 participants (15 males and 15 females). A multi-Finger Force Measurement (MFFM) System developed by Kim and Kong (2008) was applied in order to measure total grip strength and individual finger forces. The participants were asked to exert a grip force attempting to minimize the difference between the target force and their exerted force for eight different target forces (5, 15, 25, 35, 45, 55, 65, and 75% MVCs). These target forces based on the maximum voluntary contraction, which were obtained from each participant, were randomly assigned in this study. Results: The contributions of middle and ring fingers to the total grip force represented an increasing trend as the target force level increased. On the other hand, the contributions of index and little fingers showed a decreasing trend as the target force level increased. In particular, Index finger exerted the largest contribution to the total grip force, followed by middle, ring and little fingers in the case of the smallest target force level (5% MVC), whereas middle finger showed the largest contribution, followed by ring, index and little fingers at the largest target force levels (65 and 75% MVCs). Conclusion: Each individual finger showed a different contribution pattern to the grip force exertion. As the target force level increase from 5 to 75% MVC, the contributions of middle and ring fingers showed an increasing trend, whereas the contributions of index and little fingers represented a decreasing trend in this study. Application: The results of this study can be useful information when designing robotic hands, hand tools and work equipment. Such information would be also useful when abnormal hand functions are evaluated.

Comparison of Maximum Fingertip Force Distribution in Cylindrical Grasping Between Healthy Adults and Patients With Spinal Cord Injury (원통형 물체 쥐기 시 건강한 성인과 척수마비 환자의 최대 손가락 끝 힘 분포 비교)

  • Hwang, Jisun;Ree, Jae Sun;Hwang, Seonhong
    • Physical Therapy Korea
    • /
    • v.29 no.1
    • /
    • pp.28-36
    • /
    • 2022
  • Background: It is known that hand strength and fingertip force are used as an indicator of muscle strength and are also highly related to the various chronic symptoms and even lifespan. To use the individual fingertip force (IFF) as a quantitative index for clinical evaluation, the IFF should be measured and analyzed with various variables from various subjects, such as the normal range of fingertip force and the difference in its distribution by disease. Objects: We tried to measure and analyze the mean maximum IFF distribution during grasping a cylindrical object in healthy adults and patients with spinal cord injury (SCI). Methods: Five Force-sensitive resistor (FSR) sensors were attached to the fingertips of 24 healthy people and 13 patients with SCI. They were asked to grip the object three times for five seconds with their maximum effort. Results: The mean maximum IFF of the healthy adult group's thumb, index, and middle finger was similar statistically and showed relatively larger than IFF of the ring and small finger. It is a 3-point pinch grip pattern. All fingertip forces of patients with SCI decreased by more than 50% to the healthy group, and their IFF of the middle finger was relatively the largest among the five fingertip forces. The cervical level injured SCI patients showed significantly decreased IFFs compared to thoracic level injured SCI patients. Conclusion: We expect that this study results would be helpful for rehabilitation diagnosis and therapy goal decision with robust further study.

Impact of Lumen Size and Helical Coil Place Change in Spring on Orthodontic Force (Spring의 lumen size와 helical coil 형성 위치 변화가 교정력에 미치는 영향)

  • Lee, Gyu-Sun;Lee, Sun-Kyoung;Kim, Bok-Dong
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.331-337
    • /
    • 2011
  • Purpose: The purpose of this study was to impact of force system change in finger spring that add helical coil one round on orthodontic force. Methods: The following conclusions were drawn from the experiment conducted after bending 90 samples with a CNC wire forming machine while changing the height and lumen size to 1mm - 3mm - 5mm and 2mm - 3mm - 4mm respectively in the coil of the force system in finger spring added with one wheel of helical coil of 18-8 stainless steel round wire (${\Phi}0.5mm$, spring hard) from Jinsung Co. in domestic market under the following conditions: Laboratory name = Instron 5942; Temperature($deg^{\circ}C$) = 18.00; Humidity(%) = 50.00; Rate 1 = 10.00000 mm/min; Compressive extension = 5.0mm. Results: When Coil height is 1, 3, 5mm and lumen size is 2, 3, 4mm reduce finger spring as mean value of compressive extension occasion maximum load(mN) increases as coil height rises, and lumen size grows to 5.0mm. And was expose that compressive load(mN) increases as coil position of finger spring rises and increase as lumen size is decrescent. Conclusion: As the adherence height of coil was raised from 1mm through 3mm to 5mm, compressive load increased. As the lumen size increased from 2mm through 3mm to 4mm, compressive load decreased. Therefore, these results suggest that it is desirable to lower the coil height and enlarge the lumen size to enhance the biomechanical efficiency of finger spring when manufacturing the finger spring for removable orthodontic devices.