• Title/Summary/Keyword: Maximum average luminance

Search Result 17, Processing Time 0.032 seconds

Luminance Assessment of Outdoor Lighting for Advertisements at Night (옥외광고용 발광조명의 야간휘도분포 분석)

  • Shin, Hwa Young;Lee, Jong Soo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.65-72
    • /
    • 2009
  • Lighting for outdoor advertising is very common feature of building facades as they provide the information and commercial identification. As the interest of improving street beautification more widely, application of various lighting technologies has been develop for advertisement such as electric sign board and signage. Furthermore, the installation of higher sign luminance than needed has many negative consequences, including higher energy consumption and light pollution. There are now no standard for outdoor advertisements in terms of luminance, and installation of indiscreet outdoor advertisement without luminance consideration is becoming more commonplace. This study was to evaluate the luminous characteristics of outdoor advertising as a function of sign and building facade luminance, luminance ratio. Data were collected on 8 electric sign boards, 20 internally illuminated, externally illuminated, neon, and channel letter signs and 4 commercial areas. Photometric measurements were taken by CS-100(Minolta) and ProMetric-1400(Radiant Imaging) for various sign modes and sign design. Also luminance of building facades were analyzed according with CIE standard of maximum obtrusive light permitted for exterior lighting installations. The findings are as follows; (1) There were excessive luminance of electric sign boards that could affect adjacent building facade and night sky luminance. (2) Sings that are externally illuminated providing an inappropriate amount of light on to the outer surface of the sign caused higher building facade luminance and potential of unnecessary glare.

Contrast Sensitivity as a function of spatial frequency by using polarization (편광을 이용한 눈의 공간주파수-대비민감도 함수 측정기구 설계)

  • Kim, Young-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.43-48
    • /
    • 2000
  • It was to adjust the luminance of light by the rotation angle of the polarizes and analyzer. The luminance value Lmax, Lmin of Contrast Sensitivity could be obtained from the rotation angle ${\theta}_m$ of the average luminance($L_m$), the rotation angle(${\theta}_{max}$, ${\theta}_{min}$) of the maximum and the minimum's amplitude. $$L_{max}=I(0)e^{-2at}{\cdot}cos^2{\theta}_m(1+C_s^{-1})$$ $$L_{min}=I(0)e^{-2at}{\cdot}cos^2{\theta}_m(1-C_s^{-1})$$ We obtained the rotation angle(${\theta}_{max}$, ${\theta}_{min}$) of the polarizes and analyzer from the rotation angle ${\theta}_m$ of the average luminance($L_m$) and the Contrast Sensitivity($C_s$). $${\theta}_{max}=cos^{-1}[cos{\theta}_m{\cdot}(1+C_s^{-1})^{1/2}]$$ $${\theta}_{min}=cos^{-1}[cos{\theta}_m{\cdot}(1-C_s^{-1})^{1/2}]$$.

  • PDF

Study on Analysis of Characteristics of Illuminance and Luminance Distribution of LED Luminaires (LED 조명기구의 조도.휘도분포 특성 분석에 관한 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Byoung-Soo;Han, Won-Tak
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.1-7
    • /
    • 2008
  • This study is intended to compare physical properties of fluorescent luminaires with ones of LED luminaires so as to analyze fundamental characteristics of LED luminaires. For this, a comparative analysis of uniformity ratio of illuminance and luminance distribution of these two luminaires was made, and materials for applying LED luminaires to interior construction space were prepared. This study was carried out in four stages. First, a theoretical review on LED illumination light source was made compared with the existing luminaires. Second, a mock-up to control experimental variables to meet the objective of this study was manufactured. Third uniformity ratio of illuminance and luminance distribution of each luminaire were measured by using the mock-up. Fourth, a comparative analysis of uniformity ratio of illuminance and characteristics of luminance distribution of the existing fluorescent luminaires and LED ones was made. As a result of the study, the uniformity ratio of illuminance of LED luminaires, 0.559, was higher than one of the existing fluorescent luminaires, 0.522. Namely, it was shown that illuminance distribution of LED luminaires was uniform and global diffuse was good. As a result of measuring luminance distribution, it was found that luminance distribution of LED luminaires was more uniform than one of the existing fluorescent luminaires. The maximum luminance of fluorescent luminaires and LED luminaires over the wall was $180.6[cd/m^2]$ and $155.26[cd/m^2]$ respectively. Namely, the maximum luminance of fluorescent luminaires was higher than one of LED luminaires. The average luminance of fluorescent luminaires and LED luminaires was $44.32[cd/m^2]$ and $58.65[cd/m^2]$. Like this, the average luminance of LED luminaires was higher than one of fluorescent luminaires. Considering these results, it's thought that LED luminaires can give a person in the room a more comfortable working environment than fluorescent luminaires.

The Effect of Phosphor Thickness and Discharge Space on the Luminance and Addressing Time in ac PDP

  • Lee, Gi-Bum;Heo, Jeong-Eun;Kim, Gyu-Seup;Kim, Young-Kee;Lee, Sung-Hyun;Cho, Jung-Soo;Park, Chung-Hoo
    • Journal of KIEE
    • /
    • v.11 no.1
    • /
    • pp.27-32
    • /
    • 2001
  • In this study, the luminance, luminous efficiency and address time of an PDP as a parameter of the phosphor thickness and the size of discharge space are investigated. The maximum luminance and luminous efficiency are obtained at the phosphor thickness of 30 ${\mu}{\textrm}{m}$ for the rib height of 110 ${\mu}{\textrm}{m}$. For the rib height of 120~160 ${\mu}{\textrm}{m}$, the maximum values are obtained at the thickness of 50 ${\mu}{\textrm}{m}$ regardless of the kind of R, G and B phosphor. These results do not affected by the variation of discharge space. The average decrease rate of the total charge to the phosphor thickness is about 3.35pc/cell/10 ${\mu}{\textrm}{m}$ and the average increase rate of the addressing time is about 0.027 $mutextrm{s}$/10 ${\mu}{\textrm}{m}$.

  • PDF

Emission Characteristics of Fluorescent OLED with Alternating Current Power Source Driving Method (교류전원 구동방식에 의한 형광 OLED의 발광 특성)

  • Seo, Jung-Hyun;Kim, Ji-Hyun;Ju, Sung-Hoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.2
    • /
    • pp.104-109
    • /
    • 2014
  • To operate organic light emitting device (OLED) with alternating current (AC) power source without AC/DC(direct current) converter, we fabricated the fluorescent OLED and measured the emission characteristics with AC and DC. The OLED operated by AC showed higher maximum current efficiency of 8.2 cd/A and maximum power efficiency of 8.3 lm/W. But current efficiency and power efficiency of AC driven OLED showed worse than DC driven OLED at high voltage above 10 V. This result can be explained by the peak voltage of AC was $\sqrt{2}$ times than DC, In case of low driving voltage the emission characteristics were improved by the peak voltage of AC, but in case of high driving voltage the emission efficiencies were decreased by the roll off phenomena. Finally, serial OLED arrays using twelve OLEDs driven by AC 110 V showed average voltage of 9.17 V, voltage uniformity of 99.0%, average luminance of $1,175cd/m^2$, luminance uniformity of 94.4%.

A Study on the Simulation and DSF Molding of V-groove Type Light Guide for a Backlight Unit (백라이트 유닛용 V-그루브 도광판의 전산모사 및 DSF성형에 관한 비교연구)

  • Cho K. H.;Yoon K. H.
    • Transactions of Materials Processing
    • /
    • v.14 no.3 s.75
    • /
    • pp.282-290
    • /
    • 2005
  • Nowadays, TFT-LCD is widely used as display unit of many digital devices. And, the backlight unit(BLU) is used as a light source of TFT-LCD module. In the backlight unit, the most important component is a light guide, which guides the input light to the TFT-LCD module uniformly. Recently, many researchers have focused on improving the efficiency of BLU by changing the design and structure of a light guide. In the present paper, a series of simulation was performed to find the optimal luminance distribution of emanated light from the given geometry as the first step. From the results of simulations for the light guide with given V-groove pattern, the emanated light from it is mostly affected by the groove angle. In the case of acute angle, about 74 degrees was found as optimal angle to satisfy the restrictions of angular luminance distribution, FWHM, the maximum luminance, etc. However, as far as the average luminance value was concerned, the case of 120 degrees(abtuse angle) was found to be the best while prism films were added to the BLU. As a next step the light guide samples of 74 and 120 degrees were manufactured by DSF method, which was recently proposed by the authors. Of course, most of design parameters were chosen by the aid of simulation results. Finally, the results of average luminance values were compared between the simulation and DSF molded samples.

Measurement of MRI Monitor Luminance and MRI Room Illuminance with a Light Probe (Light Probe를 이용한 MRI 검사실 및 모니터의 조도와 휘도 측정)

  • Kim, Ji Min;Han, Ah Yung;Lee, Ha Young;Lee, So Ra;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.168-172
    • /
    • 2016
  • The purpose of the optimal environment of the MRI room to measured luminance and illuminance of the MRI room and the monitor. University Hospital (n = 6) of the MRI (n = 10) in the luminance and illuminance Light Probe Xi Unfors (Unfors Instruments AB, Billdal, Sweden) was measured by using the. Black luminance level and white level of illuminance is repeated three times in the middle of the side of the monitor to obtain the mean and standard deviation using a t-test statistical processing was of significance test. Monitor luminance and black level in the average $1.78cd/m^2$, the standard deviation was $0.85cd/m^2$, white level average of $43.58cd/m^2$, the standard deviation of $13.19cd/m^2$. Illuminance of MRI room was the lowest value measured in accordance with the 30.5 lux, the maximum value is 601.3 lux, mean was measured by a variety of 177.86 lux. Luminance and illuminance of the MRI room and monitor is found to have statistically significant difference (p < .05). In conclusion, refer to the recommended standard of MRI and room monitor luminance and illuminance and to create an optimal environment.

A Study on Selection Method of LED Using Lightings by Road Size (차로 크기에 따른 LED 광원 사용 가로등기구의 선정 방법 연구)

  • Jeon, Sunho;Gil, Jung-Su;Lee, Min-Wook;Yoo, Seong-Sik;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.1-7
    • /
    • 2015
  • Road lighting is designed with a goal of achieving the related standards on luminance, uniformity ratio and glare. Unless the luminaire with LID which is perfect for road conditions is used, a situation which fails to meet lighting standards may occur. The study examined the relationship of maximum spacing with average road luminance and longitudinal uniformity. Based on the result of the analysis, this study evaluated luminaire with what characteristics are suitable to achieve lighting requirements of the roads and suggested methods of selection for luminaires depending on the size of the road.

Influence of Detailed Structure and Curvature of Woven Fabric on the Luminescence Effect of Wearable Optical Fiber Fabric (직물의 세부 구조 및 굴곡이 웨어러블 광섬유의 발광 효과에 미치는 영향)

  • Yang, Jin-Hee;Cho, Hyun-Seung;Kwak, Hwy-Kuen;Oh, Yun-Jung;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.55-62
    • /
    • 2018
  • The two main requirements of wearable optical fiber fabrics are that they must presuppose a high degree of flexibility and they must maintain the luminance effect in both flat and bent conformations. Therefore, woven optical fiber fabrics that satisfy the above conditions were developed by both weaving and by using computer embroidery. First, we measured the brightness of the wearable optical fiber fabric in the flat state at a total of 10 measurement points at intervals of 1 cm. Second, the wearable optical fiber fabric was placed horizontally on the forearm, where three-dimensional bending occurs, and the luminance values were recorded at the same 10 measurement points. For the woven fabric in the flat state, the maximum, minimum, average, and standard deviation luminance values were $5.23cd/m^2$, $2.74cd/m^2$, $3.56cd/m^2$, and $1.11cd/m^2$, respectively. The corresponding luminance values from the bent forearm were $7.92cd/m^2$ (maximum), $2.37cd/m^2$ (minimum), $4.42cd/m^2$ (average), and $2.16cd/m^2$ (standard deviation). In the case of the computer-embroidered fabric, the maximum, minimum, average, and standard deviation luminance values in the flat state were $7.56cd/m^2$, $3.84cd/m^2$, $5.13cd/m^2$, and $1.04cd/m^2$, respectively, and in the bent forearm state were $9.6cd/m^2$, $3.63cd/m^2$, $6.13cd/m^2$, and $2.26cd/m^2$, respectively. Therefore, the computer-embroidered fabric exhibited a higher luminous effect than the woven fabric because the detailed structure reduced light-loss due to the backside fabric. In both types of wearable optical fiber fabric the luminance at the forearm was 124% and 119%, respectively, and the light emitting effect of the optical fiber fabric was maintained even when bent by the human body. This is consistent with the principle of Huygens, which defines the wave theory of light, and also the Huygens-Fresnel-Kirchhoff principle, which states that the intensity of light increases according to the magnitude of the angle of propagation of the light wavefront (${\theta}$).

Lightness and Chroma Mapping Consider the Device Characteristic (장치 특성을 고려한 밝기 사상 및 색역 사상)

  • 박양우;이채수;엄태억;장주석
    • Proceedings of the IEEK Conference
    • /
    • 2000.11d
    • /
    • pp.143-146
    • /
    • 2000
  • In this paper, luminance mapping for uniform color distribution and gamut mapping for maximum chroma reproduction are proposed. In the conventional lightness mapping, the average lightness difference between the two gamut is increased and different color changes in bright and dark regions are also increased. To solve these problems, a lightness mapping is proposed that minimizes the lightness difference of the cusps at each hue angle and produces same color changes in bright and dark regions. Also, chroma mapping that utilize variable anchor point and an anchor point are proposed for maximum chroma reproduction and uniform color change. The proposed algorithm reduce a sudden color change on the gamut boundary of the printer and to maintain a uniform color change during the mapping process. Accordingly, the proposed algorithm can reproduce high quality images with low-cost color devices.

  • PDF