• Title/Summary/Keyword: Maximum Strength

Search Result 3,754, Processing Time 0.039 seconds

Functional analysis of isolated posterior cruciate ligament deficient subjects (후방 십자 인대 단독 손상 환자의 기능적 분석)

  • Kim Jin Goo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.3 no.1
    • /
    • pp.66-72
    • /
    • 2004
  • Purpose: To evaluate the compensatory mechanism in vivo and develop the treatment guide by performing the comprehensive functional tests of the posterior cruciate ligament (PCL) deficient subjects. Material and Methods: 10 PCL deficient subjects and 10 healthy control group were evaluated. Performed functional tests were range of motion, posterior drawer test, Telos, 30$^{\circ}$ flexion wt-bearing view, KT-1000 arthrometer, gait analysis, EMG test and isokinetic tests. Results: Physical, KT-1000, Telos posterior tests showed significant differences, but 300 full weight bearing lateral view, muscle strength test revealed no difference between two groups. Less knee flexion at initial contact and reduced maximum valgus moment were observed in PCL deficient group. In vertical drop landing, PCL group had increased plantar flexion angle at initial contact. Conclusion: Compensatory mechanisms such as reduced unstable components and absorbing the maximal load of the joint were occurred after PCL insufficiency, which result in good clinical and functional outcomes. Further investigations would be needed to understand the functional adaptations of PCL deficient subjects.

  • PDF

Isolation and Characterization of a Diesel-Degrading Bacterium, Gordonia sp. SD8 (디젤 분해 세균 Gordonia sp. SD8 분리 및 특성)

  • Hong, Sun-Hwa;Kim, Ji-Young;Cho, Kyung-Suk
    • Microbiology and Biotechnology Letters
    • /
    • v.38 no.3
    • /
    • pp.335-339
    • /
    • 2010
  • A diesel-degrading bacterium, Gordonia sp. SD8, was isolated from soil contaminated with petroleum, and its diesel degradation was characterized in a soil as well as a liquid culture system. SD8 could grow in the mineral salt medium supplemented with diesel as a sole carbon and energy source. The maximum specific growth rate ($0.67{\pm}0.05\;d^{-1}$) and diesel degradation rate ($1,727{\pm}145$ mg-TPH $L^{-1}\;d^{-1}$) of SD8 showed at 20,000 mg-TPH $L^{-1}$ and $30^{\circ}C$, and then this bacterium could degrade high strength of diesel of 40,000 mg-TPH $L^{-1}$. The residual diesel concentration in the inoculated soil with SD8 was 3,724 mg-TPH kg-dry $soil^{-1}$ after 17 days, whereas the diesel concentration in the non-inoculated soil was $8,150{\pm}755$ mg-TPH kg-dry $soil^{-1}$. These results indicate that Gordonia sp. SD8 can serve as a promising microbial resource for the bioremediaion of contaminated soil with petroleum hydrocarbons including diesel.

Mechanical Property of Foamed Light Weight Concrete with Wasted Expanded Poly-Styrene (폐스티로폼을 혼입한 경량기포콘크리트의 역학적 특성)

  • 오세출;서치호;신상태;김봉주
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.3
    • /
    • pp.285-293
    • /
    • 2001
  • To improve the vulnerable point and the mechanical property of the existing lightweight foamed concrete, this study was intend to manufacture the lightweight foamed concrete with wasted expanded poly-styrene, examinate and analyze the mechanical property of its. The experiment was being processed with mixing the wasted expanded poly-styrene maximum 40 % by stages and which was mainly basis on the practical mixture. The results of the experiment are following. The flow value is most affected by the mixtured rate of the wasted expanded poly-styrene. The more the mixtured ratio, the less the flow value and the more the more the unit quantity of cement and the W/C, the more the flow value. The apparent specific gravity indicated 0.31∼0.54 and which is seemed to be mainly included in the 0.4 degree and 0.5 degree that are regulated in the KS F 4039. The more the mixtured wasted poly-styrene ratio, the less the apparent specific gravity. The absorbing ratio which was depend on the mixture condition indicated 11 ∼46% and the more the mixtured ratio of the wasted expanded poly-styrene, the less the absorbing ratio remarkably. The compressive strength of the lightweight foamed concrete had a tendency to increase as the mixtured ratio of the wasted poly-styrene, the ratio quantity of cement and the apparent specific gravity increasing but as the ratio of bubble decreasing. The W/C affected little.

Allowable Compressive Stress of Pre-Tensioned Members with Tee or Inverted Tee Sections at Transfer (T형 및 역T형 단면을 가지는 프리텐션부재의 프리스트레스 도입시 허용 압축응력)

  • Lee, Deuck-Hang;Lee, Jeong-Yeon;Lim, Joo-Hyuk;Kim, Kang-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.353-364
    • /
    • 2011
  • In a previous research performed by the authors, the allowable compressive stress coefficient (K) in pretensioned members with rectangular section at transfer was proposed based on strength design theory. In this study, a subsequent research of an enormous analysis was performed to determine the K factor for Tee and inverted Tee section members, considering the effect of section height (h), section type, amount of tendons ($A_{ps}$), and eccentricity ratio (e/h). Based on the analysis results, the allowable compressive stress coefficients (K) for Tee and inverted Tee section members at transfer were derived, which limit the maximum allowable stresses as 80% and 70% of the compressive strengths at the time of release for Tee section and inverted Tee section, respectively. And these were larger than the allowable stresses specified in domestic and other international codes. In order to verify the proposed equations, they were compared to the test results available in literature and other codes, which showed that the allowable stresses in domestic and international codes are unconservative for the cases with low eccentricity ratios while conservative for those with high eccentricity ratios. The proposed equations, however, estimate the allowable stresses of the Tee and inverted Tee section members reasonably close to test results.

Influence of twisting angle between fixed contact and movable contact on arc driving force in 3petal spiral type vacuum interrupter (3petal spiral type vacuum interrupter에서 가동접점전극과 고정접점전극간의 마주보는 각도의 변화가 아크구동력에 미치는 영향)

  • Kim, Byoung-Chul;Yun, Jae-Hun;Lee, Seung-Soo;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.480-480
    • /
    • 2008
  • Vacuum circuit breaker(VCB) is now emerging as an alternative of gas circuit breaker(GCB) which uses SF6 gas as insulating material whose dielectric strength is outstanding. But we have to reduce SF6 gas because SF6 gas is one of greenhouse gas and efforts to reduce greenhouse gas are now trend of the world. Therefore, we can say VCB is the optimal alternative of GCB because vacuum is environmentally friendly. The vacuum interrupter is the core part of VCB to interrupt arcing current. There are mainly two methods to extinguish arc. One is radial magnetic field (RMF) method and the other is axial magnetic field (AMF) method. We deals with RMF method in this paper. Compared with AMP, RMF arc quenching method has different principle to extinguish arc. In case of RMF method, pinch effect is much larger than AMF method. Because of pinch effect RMF type contact electrodes have the single large spot which is severly damaged and melted while AMF type contact electrodes have small and multiple spots which are slightly damaged and melted. To prevent contact electrode being damaged and melted from high temperature-arc, RMF method uses Lorentz force to move arc. In this paper we calculated and compared the arc driving force of two cases and we analyzed the force acting on each part of arc by means of commercial finite element method software Maxwell 3D. They have 3petals and we considered two cases. One is the case when fixed(upper) and movable(lower) contacts are in mirror arrangement (Case 1). The other is the case when one of two contacts (movable contact) is revolved at maximum angle as possible as it can be (Case 2). And at each case above, we analyzed arc driving force at two positions, position 1 is the closest to the center of contact and position 2 is near the edge of petal on fixed contact. As a result we could find that Case 2 generated stronger arc driving force than Case 1 at position 1. But at position 2 Case 1 generated stronger arc driving force than Case 2. This simulation method can contribute to optimizing spiral-type electrode designs in a view of arc driving force.

  • PDF

Strength Safety Study on the Stress Characteristics of a Composite Pressure Cylinder for 35MPa Hydrogen Gas Vehicle (35MPa 수소가스 자동차용 복합소재 압력용기의 응력특성에 관한 강도안전성 연구)

  • Kim, Chung-Kyun;Kim, Do-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.2
    • /
    • pp.25-30
    • /
    • 2012
  • This paper presents a stress safety of a composite pressure cylinder in which is composed of an aluminum liner and composite layers with carbon fiber/epoxy and glass fiber/epoxy resigns. The composite pressure cylinder for a hydrogen gas vehicle contains 9.2 liter hydrogen gas, and hydrogen gases are compressed by a filling pressure of 35MPa. The FEM computed results are analyzed based on the US DOT-CFFC basic requirement for a hydrogen gas cylinder and KS B ISO specification. The FEM results indicate that the stress, 247MPa of an aluminum liner is sufficiently low compared with that of 272MPa, which is 95% level of a yield stress for aluminum. And, the carbon fiber composite layers in which are wound on the surface of an aluminum cylinder are safe because the maximum carbon fiber stresses from 29.43% to 28.87% in hoop and helical directions are below 30% for a given minimum required burst pressure level, respectively. The carbon fiber composite layers are also safe because the stress ratios from 3.40 to 3.46 in hoop and helical directions are above 2.4 for a minimum safety level, respectively.

Removal of Impurities by Magnetic Separation from Waste Fluidized Cracking Catalyst for Its Reuse (폐FCC 촉매의 재활용 과정에서 자력 선별법에 의한 불순물 제거 연구)

  • Ban Bong-Chan;Lee Jin-Suk;Kim Dong-Su
    • Resources Recycling
    • /
    • v.12 no.1
    • /
    • pp.55-64
    • /
    • 2003
  • Presently, the reuse of waste FCC catalysts, which generated from the refining process of crack oil, after the removal of con-taminated metallic impurities have not been attempted domestically yet because the separation technology f3r the impurities from waste catalysts has not been established. As a basic study far the reusable portion from the waste FCC catalysts and treatment of metallic impurities are assured, there will be invoked an significant contribution not only in the recycling of abandoned wastes up to date but also in the treatment efficiency of wastes and extraction of economical benefits from them. The magnetic separation of impurities such as Fe, Ni, and V, from waste FCC catalyst has been attempted with or without its pre-oxidation at high temperature for the purpose of its reuse. The results showed that the separability of impurities by magnetic force was high far non-preoxidized catalysts compared with preoxidized ones, and employment of screen-type matrix showed a higher separation efficiency than ball-type matrix. The separability increased with the strength of magnetic field, and the method of ball matrix has separation efficiency of maximum 51.10%. The amount of metallic impurities was in the decreasing order of V, Ni, and Fe depending upon ICP analysis.

Safety Evaluation of Concert Hall Floor Vibration Using Numerical Analysis Model (수치해석모델을 이용한 콘서트 홀 바닥진동 안전성 평가)

  • Roh, Ji-Eun;Heo, Seok-Jae;Moon, Dae-Ho;Lee, Sang-Hyun;Rha, Chang-Soon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.6
    • /
    • pp.469-477
    • /
    • 2017
  • In this paper, the floor vibration of an example concert hall building was measured and floor safety criteria were analytically checked through comparison between experimental and analytical results. The floor bottom plate model was constructed considering the composite effect and the analytical model was modified to have the natural frequency identical to the measured one. Also, time history analysis was conducted using the dynamic loads induced by human rhythmic movement during a musical performance, and the analytically calculated floor accelerations were similar to the measured one. Based on this model, the floor vibration level due to the group activities of about 400 persons, maximum available persons for the concert hall, was estimated. It was confirmed that the human induced dynamic loads applied to the column and beam would be much lower than the design strength. In addition, the horizontal acceleration level is just 2% of the design seismic load, so the concert hall is safe in both vertical and horizontal excitations by human rhythmic movements.

The effects of MMH task conditions on muscle activity and fatigue of the trunk musculature (MMH 작업조건에 따른 몸통부위 근육군의 활동변화에 관한 연구)

  • 이욱기;김상호;정민근
    • Proceedings of the ESK Conference
    • /
    • 1993.10a
    • /
    • pp.223-235
    • /
    • 1993
  • 요통(Lowback Pain)을 유발하는 주요원인으로 알려져있는 MMH(Manual Materials Handling) 작업에 있어서 작업조건의 변화가 근육의 활동과 피로도에 미치는 영향을 평가하기 위해 4가지 서로 다른 작업조건하에서 몸통부위(Trunk)의 주요근육에 대한 EMG 파형분석을 실시 하였다. 본 연구에서의 분석대항작업은 실제 작업조건과 유사하레 설계된 120분간의 단속적인 인양(Lifting)/하역(Lowering) 작업으로서 작업중량은 작업자의 MVIS(Maximum Voluntary Isometric Strength)를 기준으로 설정되었으며, 매 10분 간격으로 EMG 측정이 이루어졌다. 작업물이 작업자의 정면에 위치한 대칭형(Symmetric) 작업의 경우 배면부(Dorsal) 근육인 천극근(Erector Spinae)과 활배근(Latissimus Dorsi)이 활동근(Active Muscle)인 것으로 나타났으며, 정중면(Medial Plane)을 중심으로 좌우측 근육이 동일한 근력을 발휘하였다. 작업물이 작업자의 한쪽 측면에 위치한 90도 비대칭형(Asymmetric) 작업의 경우 천극근과 활배근외에 작업물과 반대쪽 외사근(External Oblique)이 활동근으로 추가되었으며, 작업물과 반대쪽의 근육들이 더욱 큰 근력을 발휘하였다. 작업의 반복에 따른 근육의 피로도를 평가하기 위해 실시한 EMG 파형의 Spectral Analysis 결과, 비대칭형 작업시 작업물과 반대쪽의 천극근에서 작업시간의 경과에 따라 중위주파수(Median Power Frequency)가 저주 파수대로 천이(Lower Shift)하는 현상이 나타났으며, 일정한 작업량이라도 작업중량을 줄이고 작업 빈도를 높여서 작업할 경우에 이러한 현상이 더욱 두드러졌다. 작업시간의 경과에 따른 MVIS의 감소 현상은 작업빈도가 높고 비대칭형 작업일 때 가장 크게 나타났다. 총손실을 줄이고, 상대적 비용절감효과를 갖게할 수 있다고 하였다. 따라서 본 연구에서는 성인 여성기성복의 치수적합성을 높이기위하여 출산 후 중년에 접어 들면서 체형이 변화되는 것을 고려하여 연령을 분류하고(18세-34세, 30세-51세), 각 연령 집단에 따른 체형을 각각 3가지로 분류하였다. 이에 따라 의복 생산시의 총손실을 줄이기위한 상의, 하의생산시 필요한 부위별 최적규격치 간격을 제시하였다.적인 기능으로 보여지는 것에 좁혀서 작업능력의 연령증가 변화에 대하여다원적 평가를 하는 것이 실제적이라고 할 수 있다. 따라서 본 연구에서는 인간이 가지고 있는 다수의 기능중에서 수지교 치성과 연령증가와의 관계를 조사한다. 만약 연령증가 만으로 수지교치성을 평가 할 수 없는 경우에는 어떠한 요인이 수지기민성의 변화에 영향을 미치는가를 검토한다.t list)에서 자동적으로 사건들의 순서가 결정되도록 확장하였으며, 설비 제어방식에 있어서도 FIFO, LIFO, 우선 순위 방식등을 선택할 수 있도록 확장하였다. SIMPLE는 자료구조 및 프로그램이 공개되어 있으므로 프로그래머가 원하는 기능을 쉽게 추가할 수 있는 장점도 있다. 아울러 SMPLE에서 새로이 추가된 자료구조와 함수 및 설비제어 방식등을 활용하여 실제 중형급 시스템에 대한 시뮬레이션 구현과 시스템 분석의 예를 보인다._3$", chain segment, with the activation energy of carriers from the shallow trap with 0.4[eV], in he amorphous regions.의 증발산율은 우기의 기상자료를 이용하여 구한 결과 0.05 - 0.10 mm/hr 의 범위로서 이로 인한 강우손실량은 큰 의미가 없음을 알았다.재발이 나타난 3례의 환자를 제외한 9례 (75%)에서는 현재까지 재발소견을 보이지 않고 있다. 이러한 결과는 다른 보고자들과 유사한 결과를

  • PDF

An Electromagnetic Shock Wave Generator Employing a Solenoid Coil for Extracorporeal Shock Wave Therapy: Construction and Acoustical Properties (체외 충격파 치료술을 위한 솔레노이드 코일을 이용한 전자기식 충격파 발생기: 구성 및 음향학적 특성)

  • Choi Min Joo;Lee Jong Soo;Kang Gwan Suk;Paeng Dong Guk;Lee Yoon Joon;Cho Chu Hyun;Rim Geun Hie
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.5
    • /
    • pp.271-281
    • /
    • 2005
  • An electromagnetic type shock wave generator suitable for extracorporeal shock wave therapy has been constructed by employing a solenoid coil. The Property of the shock waves produced by the shock wave generator was evaluated using a needle hydrophone. It was shown that, as the capacitor discharging voltage increased from 8 to 18 kV, the Positive Peak Pressure (P+) of the shock wave increased non-linearly from 10 to 77 Wa. In contrast. the negative peak Pressure (f) varied between -3.2 and -6.8 MPa. had its absolute maximum of -6.9 ma at 14 kV The peak amplitudes P+ measured repeatedly under the same voltage setting varied within $5\;\%$ from mean values and this is very small compared to about $50\;\%$ for electrohydraulic type shock wave generators. It could be observed, from the hydrophone signal recorded over 1 ms. several sequential acoustic impulses representing bubble collapses. namely. acoustic cavitation. induced by the shock wave. A technique based on wavelet transformation was used to accurately measure the time delay between the 1st and 2nd collapse known to be closely related to the shock strength. It was observed that the measured time delay increased almost linearly from 120 to $700\;{\mu}s$ with the shock wave Pressure P+ increasing from 10 to 77 MPa.