• Title/Summary/Keyword: Maxillofacial field

Search Result 204, Processing Time 0.022 seconds

Central Giant Cell Granuloma of the Mandible: A Case Report (하악에 발생한 중심성 거대세포육아종의 치험례)

  • Chung, Jin-Wook;Oh, Deuk-Young;Seo, Je-Won;Moon, Suk-Ho;Lee, Jung-Ho;Rhie, Jong-Won;Ahn, Sang-Tae;Kim, Chang-Hyun
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.691-694
    • /
    • 2010
  • Purpose: Central giant cell granuloma is a rare, benign giant cell tumor which commonly develops in areas near the teeth. It accounts for approximately less than 7% of benign tumors of the mandible. Clinically, central giant cell granuloma is classifed into aggressive and non-aggressive type, and usually requires surgical treatment. There has been no report of central giant cell granuloma in plastic surgery field of the country, and we report a case with a brief review of the diagnosis and treatment of the disease. Methods: A 23-year-old male presented with a hard, non-tender, growing mass with the size of $4.0{\times}3.0\;cm$ on mandible for several months. Computed tomography scan showed a solid mass within thinned outer cortex on mandible. The thinned outer cortex was excised with the mass and the inner cortex was partially removed burring. After the tumor removal, mandible was fixed by reconstruction plate. Results: Pathologic report showed numerous large multinucleated giant cells, diffusely distributed in a background of ovoid-to-spindle-shaped mononuclear cells. There was no evidence of recurrence after 1 year follow up. Bony defect was regenerated and we removed the reconstruction plate. Conclusion: Removal of central giant cell granuloma results in defect of outer cortex, which can be reconstructed by using reconstruction plate, autologous bone graft or bone cement. We used reconstruction plate as a conservative method to induce secondary healing of the outer cortical defect area, which resulted in normal mastication and occlusion with no recurrence.

Assessment of bone density changes following two-jaw surgery using multidetector computed tomography: A pilot study

  • Lee, Youngjoo;Park, Jae Hyun;Chang, Na-Young;Lee, Mi-Young;Kim, Bong Chul;Seo, Hye Young;Mangal, Utkarsh;Chae, Jong-Moon
    • The korean journal of orthodontics
    • /
    • v.50 no.3
    • /
    • pp.157-169
    • /
    • 2020
  • Objective: The aim of this retrospective study was to evaluate the pre- and postsurgical bone densities at alveolar and extra-alveolar sites following two-jaw orthognathic surgery. Methods: The sample consisted of 10 patients (mean age, 23.2 years; range, 18.0-27.8 years; 8 males, 2 females) who underwent two-jaw orthognathic surgery. A three-dimensional imaging program (Invivo 5) was used with multidetector computed tomography images taken pre- and postoperatively (obtained 32.3 ± 6.0 days before surgery and 5.8 ± 2.6 days after surgery, respectively) for the measurement of bone densities at the following sites: (1) alveolar bone in the maxilla and mandible, (2) extra-alveolar sites, such as the top of the head, menton (Me), condyle, and the fourth cervical vertebrae (C4). Results: When pre- and postsurgical bone densities were compared, an overall tendency of decrease in bone density was noted. Statistically significant reductions were observed in the densities of cancellous bone at several areas of the maxillary alveolar bone; cortical and cancellous bone in most areas of the mandibular alveolar bone; cortical bone in Me; and cancellous bone in C4. There was no statistically significant difference in bone density in relation to the depth of the alveolar bone. In a comparison of the bone densities between groups with and without genioplasty, there was almost no statistically significant difference. Conclusions: Accelerated tooth movement following orthognathic surgery may be confirmed with reduced bone density. In addition, this study could offer insights into bone metabolism changes following orthognathic surgery, providing direction for further investigations in this field.

A study of sagittal condylar inclination and occlusal plane inclination of two semiadjustablearticulators with different reference plane (기준면이 다른 반조절성 교합기의 전방시상과로각과 교합평면경사각에 대한 연구)

  • Kim, Hyo-Jung;Lee, Sung-Bok;Choi, Dae-Gyun;Bak, Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.420-430
    • /
    • 2008
  • Statement of problem & Purpose: Articulators are very important for education and overall clinical situation in the field of prosthodontics, however preexisting articulators are designed and built based on maxillofacial structures and mean values of mandibular movement of Western people. Purpose of this research is to find out a adequate basis for applicating these articulators, presently used for clinical education, for Korean. Material and methods: 59 Korean adults (41 males, 18 females), aged between 24 to 41, where selected for this study. Two pairs of both maxillary and mandibular models were made for each examinee. These models where attached to both KaVo PROTARevo 7 and Hanau Modular semiadjustable articulators by using facebow transfer, than sagittal condylar inclination, occlusal plane inclination and position of mandibular on the articulator where measured. Result and conclusion: 1. Mean sagittal condylar inclination for KaVo PROTAR semiadjustable articulator was $33.75^{\circ}$(standard deviation $12.46^{\circ}$) meanwhile Hanau Modular semiadjustable articulator showed $40.72^{\circ}$(standard deviation $12.09^{\circ}$) for mean sagittal condylar inclination. 2. Mean occlusal plane inclination for KaVo PROTAR semiadjustable articulator was $-2.76{\circ}$(standard deviation $3.63^{\circ}$) meanwhile Hanau Modular semiadjustable articulator showed $11.87^{\circ}$ (standard deviation $3.63^{\circ}$) for mean occlusal plane inclination. 3. On the average center of the mandibular dentition were in the range of 5 to 7 mm of the central position of the articulator. Both anterior and posterior dentition were positioned at the center of the articulator vernacularly for KaVo PROTAR semiadjustable articulators, meantime for Hanau Modular semiadjustable articulator, anterior dentition was positioned 5 mm downwards and 3mm upwards for posterior dentition from vertically central position of the articulator.

Analysis of temperature changes and sterilization effect of diode laser for the treatment of peri-implantitis by wavelength and irradiation time (임플란트 주위염 치료용 diode laser의 파장 및 조사시간에 따른 온도 변화와 살균효과 분석)

  • Seol, Jeong-Hwan;Lee, Jun Jae;Kum, Kee-Yeon;Lee, Jong-Ho;Lim, Young-Joon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.178-188
    • /
    • 2017
  • Purpose: We compared the effects of newly developed diode laser (Bison 808 nm Diode laser) on the treatment of peri-implantitis with conventional products (Picasso 810 nm Diode laser) by comparing the surface temperature of titanium disc and bacterial sterilization according to laser power. Materials and Methods: The titanium disc was irradiated for 60 seconds and 1 - 2.5 W using diode laser 808 nm and 810 nm. The surface temperature of the titanium disc was measured using a temperature measurement module and a temperature measurement program. In addition, in order to investigate the sterilizing effect according to the laser power, 808 nm laser was irradiated after application of bacteria to sandblasted large-grit acid-etched (SLA) and resorbable blast media (RBM) coated titanium discs. The irradiated disks were examined with scanning electron microscopy. Results: Both 808 nm and 810 nm lasers increased disk surface temperature as the power increased. When the 810 nm was irradiated under all conditions, the initial temperature rise rate, the descending rate, and the temperature change before and after was higher than that of 808 nm. Disk surface changes were not observed on both lasers at all conditions. Bacteria were irradiated with 808 nm, and the bactericidal effect was increased as the power increased. Conclusion: When applying these diode lasers to the treatment of peri-implantitis, 808 nm which have a bactericidal effect with less temperature fluctuation in the same power conditions would be considered safer. However, in order to apply a laser treatment in the dental clinical field, various safety and reliability should be secured.