• Title/Summary/Keyword: Max-Min

Search Result 1,657, Processing Time 0.034 seconds

A Fundamental Approach for Developing Deformation Strength Based on Rutting Characteristics of Asphalt Concrete (소성변형과의 상관성에 근거한 아스팔트 콘크리트의 변형강도 개발을 위한 기초연구)

  • Kim, Kwang-Woo;Lee, Moon-Sup;Kim, Jun-Eun;Choi, Sun-Ju
    • International Journal of Highway Engineering
    • /
    • v.4 no.4 s.14
    • /
    • pp.23-39
    • /
    • 2002
  • This study dealt with developing a new approach for finding properties which might represent rut resistance characteristics of asphalt mixture under static loading. Two aggregates, a normal asphalt (pen 60-80) and 5 polymer-modified asphalts were used in preparation of 12 dense-graded mixtures. Marshall mix design was used in determination of OAC and each mixture at the OAC was prepared for a newly-developed Kim test on Marshall specimen (S=10cm) and gyratory specimen (S=15cm), and for wheel tracking test. Kim test used Marshall loading frame and specimens were conditioned for 30min at $60^{\circ}C$ before loading through Kim tester an apparatus consisting of a loading column and a specimen and column holder Diameter (D) of column was 3cm and 4cm with each column having different radius (r) of round cut at the bottom. The static load was applied at 50mm/min in axial direction of the specimen, not in diametral direction. The maximum load ($P_{max}$) and vertical deformation (y) at $P_{max}$ point were obtained from the test. A strength value was calculated based on the $P_{max}$ r, D and y by using the equation $K_D = 4P_{max}/{\pi}(D-2(r-\sqrt{2ry-y^2}))^2$ and is defined as the deformation strength ($kgf/cm^2$). The values of $P_{max}$/y and $K_I=K_D/y$ were also calculated. In general the leading column diameter and radius of round cut were significant factors affecting $K_D$ and $P_{max}$ values while specimen diameter was not. The statistical analyses showed the $K_D$ had the best correlation with rut depth and dynamic stability. The next best correlation was found from $P_{max}$ which was followed by $P_{max}$/y and $K_I$ in order.

  • PDF

A Study on Developing Customized Bolus using 3D Printers (3D 프린터를 이용한 Customized Bolus 제작에 관한 연구)

  • Jung, Sang Min;Yang, Jin Ho;Lee, Seung Hyun;Kim, Jin Uk;Yeom, Du Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.61-71
    • /
    • 2015
  • Purpose : 3D Printers are used to create three-dimensional models based on blueprints. Based on this characteristic, it is feasible to develop a bolus that can minimize the air gap between skin and bolus in radiotherapy. This study aims to compare and analyze air gap and target dose at the branded 1 cm bolus with the developed customized bolus using 3D printers. Materials and Methods : RANDO phantom with a protruded tumor was used to procure images using CT simulator. CT DICOM file was transferred into the STL file, equivalent to 3D printers. Using this, customized bolus molding box (maintaining the 1 cm width) was created by processing 3D printers, and paraffin was melted to develop the customized bolus. The air gap of customized bolus and the branded 1 cm bolus was checked, and the differences in air gap was used to compare $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$ and $V_{95%}$ in treatment plan through Eclipse. Results : Customized bolus production period took about 3 days. The total volume of air gap was average $3.9cm^3$ at the customized bolus. And it was average $29.6cm^3$ at the branded 1 cm bolus. The customized bolus developed by the 3D printer was more useful in minimizing the air gap than the branded 1 cm bolus. In the 6 MV photon, at the customized bolus, $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of GTV were 102.8%, 88.1%, 99.1%, 95.0%, 94.4% and the $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of branded 1cm bolus were 101.4%, 92.0%, 98.2%, 95.2%, 95.7%, respectively. In the proton, at the customized bolus, $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of GTV were 104.1%, 84.0%, 101.2%, 95.1%, 99.8% and the $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of branded 1cm bolus were 104.8%, 87.9%, 101.5%, 94.9%, 99.9%, respectively. Thus, in treatment plan, there was no significant difference between the customized bolus and 1 cm bolus. However, the normal tissue nearby the GTV showed relatively lower radiation dose. Conclusion : The customized bolus developed by 3D printers was effective in minimizing the air gap, especially when it is used against the treatment area with irregular surface. However, the air gap between branded bolus and skin was not enough to cause a change in target dose. On the other hand, in the chest wall could confirm that dose decrease for small the air gap. Customized bolus production period took about 3 days and the development cost was quite expensive. Therefore, the commercialization of customized bolus developed by 3D printers requires low-cost 3D printer materials, adequate for the use of bolus.

  • PDF

Physiological Responses to Maximal Exercise Loading in Spinal Cord Injured Paraplegia (척수손상으로 인한 하반신마비 환자의 최대운동부하시 생리학적 반응)

  • Yu, Byong-Kyu;Chung, Nak-Su
    • Physical Therapy Korea
    • /
    • v.6 no.2
    • /
    • pp.56-66
    • /
    • 1999
  • The purpose of this study focused how to show physiological responses comparing exercise group and non exercise group for progressive maximal wheelchair ergometer exercise loading in complete paraplegia. It also examined the various factors which would be influenced physiological responses. Sixteen subjects have been investigated in this study, and the subjects are divided into two groups as follows: 1) exercise group (7 subjects) 2) non exercise group (9 subjects). Each test was terminated by physical exhaustion and/or an inability to maintain a flywheel velocity. The results were as follows: 1) No difference was noted in pulmonary function test between two groups. 2) $\dot{v}$ Emax value during maximal exercise was significantly different between the groups (p<0.05). The mean $\dot{v}$ Emax of exercise group was $69.67{\ell}/min$, non exercise group was $41.47{\ell}/min$. 3) $\dot{v}$ $O_2max$(${\ell}/min$) value during maximal exercise was significantly different between the groups (p<0.05). The mean $\dot{v}$ $O_2max$(${\ell}/min$) of exercise group was $1.72{\ell}/min$, non exercise group was $1.15{\ell}/min$. 4) $\dot{v}$ $O_2$ max(ml/kg/min) value during maximal exercise was significantly different between the groups (p<0.05). The mean $\dot{v}$ $O_2max$($ml/kg{\cdot}min$) of exercise group was $25.99ml/kg{\cdot}min$, non exercise group was $18.61{\ell}/min$. 5) Maximal heart rate(HRmax) value during maximal exercise was significantly different between the groups (p<0.05). The mean HRmax of exercise group was 180.43 beats/min, non exercise group was 175.00 beats/min. 6) $\dot{v}\;E/\dot{v}\;O_2$ value during maximal exercise was not significantly different between the groups (p>0.05). The mean $\dot{v}\;E/\dot{v}\;O_2$ of exercise group was $36.36{\ell}/{\ell}\;O_2$, non exercise group was $45.46{\ell}/{\ell}\;O_2$. Considering the results which explore the exercise group with paraplegia has shown the maximal aerobic power compared with non exercise group, regular and consistent physical training is highly assumed as a main factor to improve cardiopulmonary fitness.

  • PDF

Sea fog detection near Korea peninsula by using GMS-5 Satellite Data(A case study)

  • Chung, Hyo-Sang;Hwang, Byong-Jun;Kim, Young-Haw;Son, Eun-Ha
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.214-218
    • /
    • 1999
  • The aim of our study is to develop new algorism for sea fog detection by using Geostational Meteorological Satellite-5(GMS-5) and suggest the techniques of its continuous detection. So as to detect daytime sea fog/stratus(00UTC, May 10, 1999), visible accumulated histogram method and surface albedo method are used. The characteristic value during daytime showed A(min) > 20% and DA < 10% when visble accumulated histogram method was applied. And the sea fog region which detected is of similarity in composite image and surface albedo method. In case of nighttime sea fog(18UTC, May 10, 1999), infrared accumulated histogram method and maximum brightness temperature method are used, respectively. Maximum brightness temperature method(T_max method) detected sea fog better than IR accumulated histogram method. In case of T_max method, when infrared value is larger than T_max, fog is detected, where T_max is an unique value, maximum infrared value in each pixel during one month. Then T_max is beneath 700hpa temperature of GDAPS(Global Data Assimilation and Prediction System). Sea fog region which detected by T_max method was similar to the result of National Oceanic and Atmosheric Administration/Advanced Very High Resolution Radiometer (NOAA/AVHRR) DCD(Dual Channel Difference). But inland visibility and relative humidity didn't always agreed well.

  • PDF

The Plasma Concentrations and Systemic Toxicity of Lidocaine after Maximal or Supramaximal Recommended Doses of Epidural Administration (경막외 Lidocaine의 최대사용량과 혈중농도에 대한 고찰)

  • Park, Han-Suk;Chung, Chan-Jong;Chin, Young-Jhoon
    • The Korean Journal of Pain
    • /
    • v.12 no.1
    • /
    • pp.36-42
    • /
    • 1999
  • Background: The current maximal recommended doses of lidocaine are 7 mg/kg with $5\;{\mu}g/ml$ of epinephrine. But in clinical practice, sometimes more doses of lidocaine are required to produce adequate regional anesthesia. Method: Twenty-two healthy women patients were divided into two groups and pretreated with valium 5 mg p.o., morphine 5 mg i.m., and midazolam 2 mg i.v. before operation. Of these, 7 mg/kg of 2% lidocaine with $5\;{\mu}g/ml$ of epinephrine were given to 11 patients epidurally. Initial 3 ml of epinephrine mixed lidocaine was given as a test dose and remaining doses were given 5 ml/30 sec with 3 min intervals. Radial arterial blood were drawn at 5, 10, 15, 20, 30, 45, 60, 90, 120 min to measure plasma lidocaine concentrations. After confirming all of the peak plasma concentrations of 7 mg/kg lidocaine were absolutely under $5\;{\mu}g/ml$, the other 11 patients were given 10 mg/kg of 2% lidocaine with $5\;{\mu}g/ml$ of epinephrine epidurally and blood samplings were taken according to the same method of 7 mg/kg group. The peak plasma concentration ($C_{max}$), time to reach to $C_{max}$ ($T_{max}$), time to reach to $T_4$, maximal sensory block level, systemic toxicity, and vital sign changes were investigated. Result: $C_{max}$ was significantly higher in 10 mg/kg group ($5.1{\pm}1.3\;{\mu}g/ml$) than 7 mg/kg group($3.3{\pm}0.5\;{\mu}g/ml$), but $T_{max}$ ($10.5{\pm}2.7$ min vs $10.9{\pm}3.1$ min) was not different. Time to reach $T_4$ was significantly shorter in 10 mg/kg group ($9.5{\pm}2.7$ min) than 7 mg/kg group ($12.7{\pm}3.2$ min) but maximal sensory block level ($T_{3.7{\pm}0.7}$ vs $T_{2.7{\pm}1.0}$) was not different. In four patients of 10 mg/kg group, peak plasma concentrations exceeded $5\;{\mu}g/ml$, but no systemic toxicities appeared. No significant vital sign changes were observed. Conclusion: The current maximal recommended doses of lidocaine, merely based on body weight are not always appropriate. Further studies are needed to determine more precise guideline of maximal doses that include various pharmacokinetic components.

  • PDF

Correlation Analysis of Diffusion Metrics (FA and ADC) Values Derived from Diffusion Tensor Magnetic Resonance Imaging in Breast Cancer (유방암의 확산텐서 자기공명 영상에서 유도된 확산 지표(FA, ADC) 값의 연관성 분석)

  • Lee, Jae-Heun;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.755-762
    • /
    • 2018
  • The purpose of this study was to compare the FA(faractional anisotropy) and ADC(apparent diffusion coefficient) values, which were derived from diffusion tensor imaging in breast cancer patients. The diffusion gradient used in this study was derived from quantitative diffusion indices using 20 directions(b-value, 0 and $1,000s/mm^2$). Quantitative analysis was analyzed using Pearson's correction and qualitative analysis using for correction coefficients. As a result, $FA_{min}$, $FA_{mean}$ and $FA_{max}$ were $0.098{\pm}0.065$, $0.302{\pm}0.142$ and $0.634{\pm}0.236$, respectively(p > 0.05). The $ADC_{min}$, $ADC_{mean}$ and $ADC_{max}$ were $0.741{\pm}0.403$, $1.095{\pm}0.394$ and $1.530{\pm}0.447$, respectively(p > 0.05). The $FA_{min}$, $FA_{mean}$, and $FA_{max}$ mean values were $0.132{\pm}0.050$, $0.418{\pm}0.094$, and $0.770{\pm}0.164$ for Category 6 and Kinetic Curve Pattern III, respectively. $ADC_{min}$, $ADC_{mean}$, and $ADC_{max}$ were $0.753{\pm}0.189$, $1.120{\pm}0.236$, and $1.615{\pm}0.372$, respectively. Quantitative analysis showed negative correlation between $ADC_{mean}-FA_{mean}$ and $ADC_{max}-FA_{max}$(p = 0.001, 0.003). The qalitative analysis showed ADC 0.628(p = 0.001), FA 0.620(p = 0.001) in the internal evaluations, ADC 0.677(p = 0.001), FA 0.695(p = 0.001) in external evaluations. In conclusion, based on the morphological examination, time to signal intensity graph is the form of wash-out(pattern III) in the dynamic contrast enhance examination, As a result, the $ADC_{mean}$ $1.120{\pm}0.236$ and $FA_{mean}$ values were $0.032{\pm}0.142$ with a negative correlation (Y=1.44-1.12X). Therefore, If we understand the shape of time to signal intensity graph and the relationship between ADC and FA, It will be a criterion for distinguishing malignant diseases in breast cancer.

Hybrid Method of Max-Min Ant System and Rank-based Ant System for Optimal Design of Location Management in Wireless Network (무선통신네트워크에서 위치관리 최적설계를 위한 최대-최소개미시스템과 랭크개미시스템의 혼합 방법)

  • Kim, Sung-Soo;Kim, Hyung-Jun;An, Jun-Sik;Kim, Il-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1309-1314
    • /
    • 2007
  • The assignment of cells to reporting or non-reporting cells is an NP-hard problem having an exponential complexity in the Reporting Cell Location Management (RCLM) system. Frequent location update may result in degradation of quality of service due to interference. Miss on the location of a mobile terminal will necessitate a search operation on the network when a call comes in. The number of reporting cells and which cell must be reporting cell should be determined to balance the registration (location update) and search (paging) operations to minimize the cost of RCLM system. T1is paper compares Max-Min ant system (MMAS), rank-based ant system (RAS) and hybrid method of MMAS and RAS that generally used to solve combinatorial optimization problems. Experimental results demonstrate that hybrid method of MMAS and RAS is an effective and competitive approach in fairly satisfactory results with respect to solution quality and execution time for the optimal design of location management system.

Interactive Virtual Anthroscopy Using Isosurface Raycasting Based on Min-Max Map (최대-최소맵 기반 등위면 광선투사법을 이용한 대화식 가상 관절경)

  • 임석현;신병석
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.103-109
    • /
    • 2004
  • A virtual arthroscopy is a simulation of optical arthroscopy that reconstructs anatomical structures from tomographic images in joint region such as a knee, a shoulder and a wrist. In this paper, we propose a virtual arthroscopy based on isosurface raycasting, which is a kind of volume rendering methods for generating 3D images within a short time. Our method exploits a spatial data structure called min-max map to produce high-quality images in near real-time. Also we devise a physically-based camera control model using potential field. So a virtual camera can fly through in articular cavity without restriction. Using the high-speed rendering method and realistic camera control model, we developed a virtual arthroscopy system.

Study on Fatigue Analysis for the Cutout Panel Structure using the Relation of Max-Min Principal Stress (최대 최소 주응력 관계를 활용한 Cutout Panel 구조물의 피로해석연구)

  • Shin, Insoo;Park, Gyucheul;Moon, Jungwon;Hong, Seunghyun
    • Journal of Aerospace System Engineering
    • /
    • v.9 no.4
    • /
    • pp.31-36
    • /
    • 2015
  • The fatigue analysis for cutout panel used for the weight reduction of aircraft has been conventionally performed through the open hole concept using the reference stress and stress concentration factor (Kt). However, in the actual structure cases, the goal of weight reduction might be less meaningful due to the conservative approach induced by the difficulties of extracting the confident reference stress from FE-Analysis in the complicated loading behavior. Therefore a new approach is proposed in order to secure the effectiveness of weight reduction and validate the confidence of the analysis results using the interaction of max-min principal stress at the critical location of open hole edge line.

Effects of partial sleep deprivation after prolonged exercise on metabolic responses and exercise performance on the following day

  • Mamiya, Aoi;Morii, Ikuhiro;Goto, Kazushige
    • Korean Journal of Exercise Nutrition
    • /
    • v.25 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • [Purpose] We determined the effect of partial sleep deprivation (PSD) after an exercise session on exercise performance on the following morning. [Methods] Eleven male athletes performed either a normal sleep trial (CON) or a PSD trial. On the first day (day 1), all subjects performed an exercise session consisting of 90 min of running (at 75% ${\dot{V}}O_{2max}$) followed by 100 drop jumps. Maximal strength (MVC) was evaluated before and after exercise. In the CON trial, the sleep duration was 23:00-7:00, while in the PSD trial, the sleep duration was shortened to 40% of the regular sleep duration. On the following morning (day 2), MVC, the metabolic responses during 20 min of running (at 75% ${\dot{V}}O_{2max}$), and time to exhaustion (TTE) at 85% ${\dot{V}}O_{2max}$ were evaluated. [Results] On day 2, neither the MVC nor ${\dot{V}}O_2$ during 20 min of running differed significantly between the two trials. However, the respiratory exchange ratio was significantly lower in the PSD trial than in the CON trial (p = 0.01). Moreover, the TTE was significantly shorter in the PSD trial than in the CON trial (p = 0.01). [Conclusion] A single night of PSD after an exercise session significantly decreased endurance performance without significantly changing muscle strength or cardiopulmonary response.