• Title/Summary/Keyword: Mattress

Search Result 201, Processing Time 0.029 seconds

Analysis of Body Pressure Distribution Characteristics According to the Design Factors of the Air-Cell Mattress for Preventing Decubitus Ulcer (욕창방지방석용 공기셀의 설계요소에 따른 체압 분포 특성 분석)

  • Cho, Hyeon-Seok;Ryu, Jei-Cheong;Kim, Gyoo-Suk;Mun, Mu-Sung;Lee, In-Hyuk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.5
    • /
    • pp.118-126
    • /
    • 2007
  • A finite element simulation model was developed for the performance optimization of a closed type air-cell mattress used for the ulcer prevention. An H-model with material properties of human flesh and kinematic joints were used for the calculation of the body contact pressure. The material property of rubber air-cell was evaluated by tensile test of standard specimen. We evaluated the body contact pressure distribution after laying human model on the inflated air-cell mattress. It was found that the body contact pressure was dependent on cell height. but hardly affected by the thickness of the rubber in a cell.

Microvascular Anastomosis Using Horizontal Mattress Suture Technique (Horizontal Mattress Suture Technique을 이용한 미세혈관 문합)

  • Woo, Sang-Hyun;Kim, Jeong-Cheol;Jung, Yung-Sik;Choi, See-Ho;Choi, Won-Hee
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.2
    • /
    • pp.71-78
    • /
    • 1989
  • Horizontal mattress suture technique on microvascular anastomosis of rat(body weight : 200-250gm) femoral artery was evaluated. The present study was conducted to compare the horizontal mattress suture with simple interrupted suture on the suture time, patency rate of the sutured vessels, and the histological changes of surgical site of the vessel wall during wound healing period. The mean suture time of the vessel wall with horizontal mattress suture technique was 15min. 49sec. ${\pm}$ 2.14, which is significantly shorter than that of simple interrupted suture technique. The patency rate of the sutured vessel in both groups was statistically not different each other till post-operative 3rd day but patency rate of horizontal mattress suture was higher than that of simple interrupted suture at post-operative 3rd week. The histological findings such as intimal noss, medial degenention and intimal regeneration were similar in both groups.

  • PDF

Study on Critical_Allowable Shear Stress of Filling Rocks With Mattress Revetment (호안용 매트리스내 채움재의 한계_허용 전단응력에 관한 연구)

  • Bae, Sang-Soo;Lee, Seung-Yoon;Jee, Hong-Kee
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • Critical and allowable shear stress acting on the mattress revetment, is presented in this study. First of all, shear stress at each spot is computed when the hydraulic power act on the waterway. Secondly, median diameter of the filling rocks is computed using shear stress and Shields coefficient which are used to decide the critical motion of the particle. Finally, the range of critical and allowable shear stress is estimated which meet the particle stability and indicated that the mattress is a stable hydraulic structure in comparison with the riprap. Therefore the required median diameter of riprap is three times higher than that of mattress. Contrarily, this study also analyzed that resisting power of mattress to shear stress is three times higher than that of riprap on the same size.

Design and Construction of Cellular Foundation Mattress as Foundations of Building Structures (건축구조물 기초로서 셀룰러 기초 매트리스의 설계 및 시공)

  • Jeong Young Lee;Jong Gon Ko;Nguyen Ngoc Son;Jae Hak Park;Doo Kie Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.1
    • /
    • pp.25-37
    • /
    • 2023
  • Cellular Foundation Mattress made of new materials such as high density polyethylene, are not currently use for the foundation of small and medium-sized buildings in Korea. Therefore, they need to be developed and verified based on domestic ground and field conditions. This study presents the basic design and construction method of Cellular Foundation Mattress. Since the foundation reinforcement effect of Cellular Foundation Mattress should be evaluated and verified for soft ground, a performance comparison evaluation was conducted using the Soilbag method, which is commonly used for the foundation of small and medium-sized buildings in Korea. After the mattress reinforcement, the settlement amount decreased by 38.4% compared to the original ground and the bearing capacity increased by 159%, confirming the same ground reinforcement effect and ground stability as the Soilbag method.

A Study on the Bed Climate and the Physiological Responses in Sleep. - On Ondol Environment - (수면시 침상기후와 인체생리반응에 관한 연구 -온돌환경을 중심으로-)

  • Kim Myung Ju;Choi Jeong Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.2 s.38
    • /
    • pp.77-87
    • /
    • 1991
  • The purpose of this study were to investigate the bed climate and the physiological responses in sleep on the traditional Korean floor heating system called Ondol. Ondol has been the most widely used heating system in Korea, yet there has been a no systematic studies examined its environmental effects on human body. Experimental room was constructed to match the typical thermal environment of Ondol. (floor surface temperature; $32\~33^{\circ}C$, air temperature; $22.5{\pm}1.0^{\circ}C$, relative humidity; $64.0{\pm}4.0\%$RH, air velocity; 0.25 m/sec.) Three different combinations of bedclothes were chosen for the experiment based on the study results showing that they were the most widely used types in Korea. Type 1 was the combination of a cotton-padded mattress with a cotton-padded Korean style blanket. Type 2 was a cotton-padded mattress with a cotton-guilted Korean style blanket. Type 3 was a cotton-padded matless with a polyacryl blanket. Thermal resistance of each of these combina-tions in the bedclothes was measured using thermal manikin. Two adult female was chosen for the seven hour sleeping experiment which was known to be the average sleeping hours of Korean adult female. The bed climate was measured with the temperature under the mattress, the surface temper-ature of the mattress, and the air temperature and the relative humidity of the space between the mattress and blanket. The skin temperature, rectal temperature of the subjects and the bed climate were measured eight times, one hour before the experiment and every hour during the experiment. The weight loss and the subjective sensation were measured for the each subjects before and after the experiment. The procedure was repeated twice with two subjects and three types of bedclothes, yielding twelve combinations of results. The results were as follows; 1. With the surface temperature of $32\~33^{\circ}C$ of Ondol, air temperature was $22.5{\pm}1.0^{\circ}C$ with $64.0{\pm}4.0\%$ RH. The bed climates were $39.2{\pm}40.8^{\circ}C$ under the mattress, $35.3\~36.2^{\circ}C$ on the mattress, and $26.9\~32.0^{\circ}C$ with $56.0\~71.3\%$ RH between the mattress and the blanket. 2. Mean skim temperature during sleep was 34.2"C with local skin temperature of $34.0\~35.5^{\circ}C$. The skin temperatures of abdomen, thigh, foot were higher than the other parts of the body. 3. The skin temperature of chest, thigh, leg and back varied significantly according to the combinations of bedclothes. With the cotton-padded blanket, the skin temperature was the highest, while with the cotton-guilted blanket showed lowest. 4. Examining the relationship between the mean skin temperature and the local skin temper-ature, the chest temperature showed the highest correlation with the former. Therefore, the chest temperature can be recommended to represent the skin temperature in measuring the bed climate. 5. The subjective bed climates were $39.0\~40.4^{\circ}C$ under the mattress, $35.2\~35.9^{\circ}C$ on the mattress, $29.8\~31.6^{\circ}C$ with $56.8\~68.4\%$ RH between the mattress and blanket. In sum, from this experiment we not only obtained the reliable value of bed climates on Ondol, but also showed that the bed climates and the physiological responses were affected differently according to the materials of bed clothes.

  • PDF

A Study on the Hydraulic Characteristics for River Bed Revetments using Mattress (하상보호용 매트리스의 수리학적 특성 연구)

  • Bae, Sang-Su;Heo, Chang-Hwan;Ji, Hong-Gi;Lee, Sun-Tak
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.1
    • /
    • pp.77-90
    • /
    • 2002
  • The condition of initial movement for the river bed revetment using rip rap is a limit condition beyond which the lining is progressively destroyed as the separate elements are removed by the flow. In the case of the river bed revetment using mattress, however, after the initial movement the containment offered by the mesh remains. A new situation of equilibrium with a deformed river bed revetment using mattress is obtained, allowing it to withstand more severe conditions without compromising the resistance and without further bed deformation. Shield's coefficient for the river bed revetment using mattress is twice the value of that for the river bed revetment using rip rap. This means that with the same hydraulic behavior conditions, the average dimension of the rocks to be used in the river bed revetment using mattress is half that of the river bed revetment using rip rap rock. When the same size rocks are used the allowable velocity for the river bed revetment using mattress is more than twice, even as much as 3 or 4 times that for the river bed revetment using rip rap.

Locking horizontal mattress suture as the alternative closure method for scalp lacerations difficult to suture with staple (두피 봉합기로 봉합하기 어려운 두피 열상에 시행한 잠금 수평 매트리스 봉합법의 유용성 관찰 연구)

  • Sah, Seung Woo;Seol, Seunghwan;Lee, Woon Jeong;Woo, Seon Hee;Kim, Dae Hee;Lee, June Young;In, Sangkook;Kim, Bonggyeom
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.649-655
    • /
    • 2018
  • Objective: This paper reports the possibility of using of a locking horizontal mattress suture technique in repairing lacerations that are difficult to suture with staples. Methods: Data were collected retrospectively over a 6-month period regarding the routine repair of scalp lacerations: those in areas injured by a high energy blunt mechanism, continued to bleed after pressure, nonlinear or damaged skin repaired with a locking horizontal mattress technique, and simple interrupted technique. The effects of the two techniques used to repair scalp lacerations on wound healing, complication rate, and patient satisfaction were examined. The categorical variables are expressed as the number and percent. A Mann-Whitney-Wilcoxon test was used for statistical analysis. A P-value less than 0.05 was considered significant. Results: Thirty-seven consecutive patients with scalp lacerations presented for care. Wound closure was accomplished with the locking horizontal mattress sutures in 40.5% (n=15) (median length, 5.0 cm; interquartile range [IQR], 4.0-7.0 cm). Simple interrupted sutures (median length, 4 cm; IQR, 3.0-5.0 cm) were used in 59.5% (n=22) (P=0.015). The frequency of additional bandage compression (P=0.008), frequency of exudative hemorrhage (P=0.018), and suture mark frequency at suture removal (P=0.047) were significantly lower in the locking horizontal mattress group. Conclusion: The locking horizontal mattress suture, which has the advantage of a horizontal mattress suture, may be one of the ways that can be used alternatively to treat scalp lacerations that difficult to suture with staples.

ECG Measurement Method during Sleep with Array of Capacitive Electrodes Attached to Bed (침대에 부착된 용량성 전극 배열을 이용한 수면 중의 심전도 측정)

  • Lim, Y.G.;Kim, K.K.;Park, K.S.;Jeong, D.U.
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.521-524
    • /
    • 2005
  • In order to measure ECG in daily life, a new ECG measurement method on bed was developed. The provided method does not require any direct conductive contact between the instrument and bare skin, so that it does not cause the uncomfortable feel of touch and the possible skin trouble which are typical shortcomings of the conventional conductive contact ECG measurement. The provided method utilized an array of high-input-impedance active electrodes fixed on the mattress and an indirect-skin-contact ground made of a large conductive textile sheet and laid on lower area of the mattress. A thin cotton bedcover covered the mattress, the electrodes, and the conductive textile and subjects lay on the mattress over the bedcover. ECG was obtained successfully. However its signal quality is lower and the motion artifact is larger than direct-contact measurement. Careful measurement setup was needed to reduce the motion artifact originated from variation in static electricity. From the ECG obtained by the provided method, R-peak could be discriminated easily and the information about the position and the posture of the subject could be obtained.

  • PDF